Implications of Safety and Operational Features of Small, Advanced Reactors for the Evaluation of Important Human Actions

The design and operational characteristics of non-light water reactors are likely to change the role of human actions in safety function management and the types of human actions that are deemed important. The objectives of this report are to: • Identify the implications of small, advanced reactor design characteristics on human performance and the changing role of human actions in the management of safety functions. • Identify the methods that may be used to identify important human actions. • Identify how HFE safety reviewers can help ensure that the methods adequately model human actions to identify those that are important to safety. We identified the implications of small, advanced reactor characteristics on the role of personnel in safety function management. Then we addressed how designers can identify which human actions are important to safety using both probabilistic risk assessment (PRA) and deterministic analyses. PRA identifies important human actions using risk-importance criteria. Deterministically identified important human actions include those identified by analyses of situations such as transients and accidents and defense in depth. In all cases, the acceptability of the analyses is dependent on the modeling, quantification, and criterion selection to determine which human actions are important. How well the designers address these processes determines the acceptability of their methodology.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

10 CFR 830 Major Modification Determination for Advanced Test Reactor RDAS and LPCIS Replacement

The replacement of the ATR Control Complex's obsolete computer based Reactor Data Acquisition System (RDAS) and its safety-related Lobe Power Calculation and Indication System (LPCIS) software application is vitally important to ensure the ATR remains available to support this national mission. The RDAS supports safe operation of the reactor by providing 'real-time' plant status information (indications and alarms) for use by the reactor operators via the Console Display System (CDS). The RDAS is a computer support system that acquires analog and digital information from various reactor and reactor support systems. The RDAS information is used to display quadrant and lobe powers via a display interface more user friendly than that provided by the recorders and the Control Room upright panels. RDAS provides input to the Nuclear Engineering ATR Surveillance Data System (ASUDAS) for fuel burn-up analysis and the production of cycle data for experiment sponsors and the generation of the Core Safety Assurance Package (CSAP). RDAS also archives and provides for retrieval of historical plant data which may be used for event reconstruction, data analysis, training and safety analysis. The RDAS, LPCIS and ASUDAS need to be replaced with state-of-the-art technology in order to eliminate problems of aged computer systems, and difficulty in obtaining software upgrades, spare parts, and technical support. The major modification criteria evaluation of the project design did not lead to the conclusion that the project is a major modification. The negative major modification determination is driven by the fact that the project requires a one-for-one equivalent replacement of existing systems that protects and maintains functional and operational requirements as credited in the safety basis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electrical Cross-Tie Option and Issues to Cope With Extended Station Blackout

The electrical cross-tie option was proposed to cope with extended station blackout event (Ext-SBO) for Barakah NPP in UAE, the EDG Cross-Tie consider a donor Unit EDG as a power source for an Ext-SBO Unit under specific conditions. The cross-tie option is discussed and the issues related to this option are generated in systematic approach as a part of dependencies between multiple units. The applied approach benefited from the previous classification of the historical occurred events as site risk that has dependencies with an enhancement of the approach by adding the operation dimension to the dependencies risk.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A study on the effect of various design parameters on the natural circulation flow rate of the ex-vessel core catcher cooling system of EU-APR1400

In this paper, a study on the effect of various design parameters such as the channel gap width, heat flux distribution, down-comer pipe size and two-phase flow slip ratio on the natural circulation flow rate is performed based on a physical model for a natural circulation flow along the flow path of the ex-vessel core catcher cooling system of an EU-APR1400, and these effects on the natural circulation flow rate are analyzed and compared with the minimum flow rate required for the safe operation of the system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Management of historical waste from research reactors: the Dutch experience

Most radioactive waste emerges as well-defined waste streams from operating power reactors. The management of this is an on-going practice, based on comprehensive (IAEA) guidelines. A special waste category however consists of the historical waste from research reactors, mostly originating from various experiments in the early years of the nuclear era. Removal of the waste from the research site, often required by law, raises challenges: the waste packages must fulfill the acceptance criteria from the receiving storage site as well as the criteria for nuclear transports. Often the aged waste containers do not fulfill today's requirements anymore, and their contents are not well documented. Therefore removal of historical waste requires advanced characterization, sorting, sustainable repackaging and sometimes conditioning of the waste. This paper describes the Dutch experience of a historical waste removal campaign from the Petten High Flux research reactor. The reactor is still in operation, but Dutch legislation asks for central storage of all radioactive waste at the COVRA site in Vlissingen since the availability of the high- and intermediate-level waste storage facility HABOG in 2004. In order to comply with COVRA's acceptance criteria, the complex and mixed inventory of intermediate and low level waste must be characterized and conditioned, identifying the relevant nuclides and their activities. Sorting and segregation of the waste in a Hot Cell offers the possibility to reduce the environmental footprint of the historical waste, by repackaging it into different classes of intermediate and low level waste. In this way, most of the waste volume can be separated into lower level categories not needing to be stored in the HABOG, but in the less demanding LOG facility for low-level waste instead. The characterization and sorting is done on the basis of a combination of gamma scanning with high energy resolution of the closed waste canister and low-resolution localized gamma scanning inside a hot cell. A complicating factor is that the conditioning of the waste, consisting of compacting and cementing, would require such an extensive infrastructure at the Petten site, that it appeared to be more practical to have it executed by a foreign service provider. Therefore the waste packages have to comply with cross-border transport and waste acceptance criteria, and the national legislation of this service provider too. This paper describes this historical waste project, focusing on the fast and precise characterization approach, the expert system behind it, and the sorting and repackaging effort at the Petten site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Work Domain Analysis of a Predecessor Sodium-Cooled Reactor as Baseline for AdvSMR Operational Concepts

This report presents the results of the Work Domain Analysis for the Experimental Breeder Reactor (EBR-II). This is part of the phase of the research designed to incorporate Cognitive Work Analysis in the development of a framework for the formalization of an Operational Concept (OpsCon) for Advanced Small Modular Reactors (AdvSMRs). For a new AdvSMR design, information obtained through Cognitive Work Analysis, combined with human performance criteria, can and should be used in during the operational phase of a plant to assess the crew performance aspects associated with identified AdvSMR operational concepts. The main objective of this phase was to develop an analytical and descriptive framework that will help systems and human factors engineers to understand the design and operational requirements of the emerging generation of small, advanced, multi-modular reactors. Using EBR-II as a predecessor to emerging sodium-cooled reactor designs required the application of a method suitable to the structured and systematic analysis of the plant to assist in identifying key features of the work associated with it and to clarify the operational and other constraints. The analysis included the identification and description of operating scenarios that were considered characteristic of this type of nuclear power plant. This is an invaluable aspect of Operational Concept development since it typically reveals aspects of future plant configurations that will have an impact on operations. These include, for example, the effect of core design, different coolants, reactor-to-power conversion unit ratios, modular plant layout, modular versus central control rooms, plant siting, and many more. Multi-modular plants in particular are expected to have a significant impact on overall OpsCon in general, and human performance in particular. To support unconventional modes of operation, the modern control room of a multi-module plant would typically require advanced HSIs that would provide sophisticated operational information visualization, coupled with adaptive automation schemes and operator support systems to reduce complexity. These all have to be mapped at some point to human performance requirements. The EBR-II results will be used as a baseline that will be extrapolated in the extended Cognitive Work Analysis phase to the analysis of a selected advanced sodium-cooled SMR design as a way to establish non-conventional operational concepts. The Work Domain Analysis results achieved during this phase have not only established an organizing and analytical framework for describing existing sociotechnical systems, but have also indicated that the method is particularly suited to the analysis of prospective and immature designs. The results of the EBR-II Work Domain Analysis have indicated that the methodology is scientifically sound and generalizable to any operating environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Simple Program to Estimate the Fast Modular Reactor Steady-State Closed Brayton Cycle Operating Parameters

The Fast Modular Reactor (FMR) is a gas-cooled fast reactor (GFR) that produces a net electricity output of 50 MW with helium-driven closed Brayton cycle. The power plant includes reactor system and power conversion unit (PCU). The reactor system produces fission energy that is transferred by helium flow. The PCU consists of a turbine, two compressors, and three heat exchanges. More specifically, the recuperator is a counter-flow energy recovery heat exchanger. The precooler and intercooler are the heat sinks. To analyze and understand the sensitivity of plant performance to the design parameters, a numerical program was written to calculate the plant operating parameters represented by the helium temperature, pressure, mass flow, and the heat sink temperatures. The program was developed for the steady-state operating condition. etc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Supporting resilience in nuclear power plant operations - conceptual frames for human factors development and validation - 166

This is a summary paper of conceptual developments on nuclear power plant operation by the human factors team at VTT Technical Research Centre of Finland. While drawing together years of studies, the paper also discusses recent progresses in training development. Firstly, there is a long background in work analysis and system validation. The analysis model applied provides a model for assessing and identifying 'core-task functions,' that is, basic functions that should be fulfilled within work activity. Secondly, we have evaluated the existing training practices at a Finnish plant and identified challenges that could be generally prevalent in the nuclear domain - they seem to reflect the hierarchical and safety-critical nature of NPP operation. In terms of potential solutions, we are currently testing and developing some new self-evaluation and self-confrontation methods. First and foremost, however, we discuss the common theory basis for our research approaches. On the broadest level, our development and research work reflects the view of safety as expressed by resilience engineering literature: safety is not seen merely as 'negative' lack of mistakes, but also as 'positive' capability to solve and anticipate problems. For example, it is assumed that operators' capability for situational interpretation should be supported at all times: even if the emergency procedures dictate operator activity specifically, the operators should understand the influence of the operating procedures for the plant process and system state. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Water-Energy Issues for Nuclear Power with Industry Perspective

The water-energy nexus is a dynamic, ever evolving challenge involving technological changes, regulatory updates, economic constraints, environmental issues, and political attributes. This report expands on a previous report that gave an initial assessment of the water-energy nexus challenges facing the U.S. commercial industry. This follow-up report provides analysis and insights from stakeholder interviews focusing on the issues faced by the U.S. commercial nuclear energy industry within the water-energy nexus space. This report updates and expand the “Cooling Water Issues and Opportunities at U.S. Nuclear Power Plants” This report includes analysis on water withdrawal and consumption by operating nuclear reactors, evolving policy risks that could impact the operation of the existing commercial nuclear fleet, implications of water markets, trading and water rights, the changing energy grid, progressing environmental risks (including analysis on the possible impact of climate change on water availability and nuclear power plant performance), and opportunities to reduce water related risk. The feedback from the stakeholders’ interviews helps incorporate viewpoints from within the nuclear and related industry that can lack representation in other research areas, without constituting a comprehensive opinion survey. Stakeholders interviewed include nuclear power plants operators, water treatment providers, developers, and vendors of reactor technologies.

99 GENERAL AND MISCELLANEOUS↗

ASSESSMENT OF THE POTENTIAL FOR HYDROGEN GENERATION DURING GROUTING OPERATIONS IN C-REACTOR DISASSEMBLY BASIN

C-reactor disassembly basin is being prepared for deactivation and decommissioning (D and D). D and D activities will consist primarily of immobilizing contaminated scrap components and structures in a grout-like formulation. The disassembly basin will be the first area of the C-reactor building that will be immobilized. The scrap components contain aluminum alloy materials. Any aluminum will corrode very rapidly when it comes in contact with the very alkaline grout (pH > 13), and as a result would produce hydrogen gas. To address this potential deflagration/explosion hazard, Savannah River National Laboratory (SRNL) reviewed and evaluated existing experimental and analytical studies of this issue to determine if any process constraints are necessary. The risk of accumulation of a flammable mixture of hydrogen above the surface of the water during the injection of grout into the C-reactor disassembly area is low if the assessment of the aluminum surface area is reliable. Conservative calculations estimate that there is insufficient aluminum present in the basin areas to result in significant hydrogen accumulation in this local region. The minimum safety margin (or factor) on a 60% LFL criterion for a local region of the basin (i.e., Horizontal Tube Storage) was greater than 3. Calculations also demonstrated that a flammable situation in the vapor space above the basin is unlikely. Although these calculations are conservative, there are some measures that may be taken to further minimize the risk of developing a flammable condition during grouting operations.

08 HYDROGEN↗

GRAFEC: A New Spanish Program to Investigate Waste Management Options for Radioactive Graphite - 12399

Spain has to manage about 3700 tons of irradiated graphite from the reactor Vandellos I as radioactive waste. 2700 tons are the stack of the reactor and are still in the reactor core waiting for retrieval. The rest of the quantities, 1000 tons, are the graphite sleeves which have been already retrieved from the reactor. During operation the graphite sleeves were stored in a silo and during the dismantling stage a retrieval process was carried out separating the wires from the graphite, which were crushed and introduced into 220 cubic containers of 6 m{sup 3} each and placed in interim storage. The graphite is an intermediate level radioactive waste but it contains long lived radionuclides like {sup 14}C which disqualifies disposal at the low level waste repository of El Cabril. Therefore, a new project has been started in order to investigate two new options for the management of this waste type. The first one is based on a selective decontamination of {sup 14}C by thermal methods. This method is based on results obtained at the Research Centre Juelich (FZJ) in the Frame of the EC programs 'Raphael' and 'Carbowaste'. The process developed at FZJ is based on a preferential oxidation of {sup 14}C in comparison to the bulk {sup 12}C. Explanations for this effect are the inhomogeneous distribution and a weaker bounding of {sup 14}C which is not incorporated in the graphite lattice. However these investigations have only been performed with graphite from the high temperature reactor Arbeitsgemeinschaft Versuchsreaktor Juelich AVR which has been operated in a non-oxidising condition or research reactor graphite operated at room temperature. The reactor Vandellos I has been operated with CO{sub 2} as coolant and significant amounts of graphite have been already oxidised. The aim of the project is to validate whether a {sup 14}C decontamination can also been achieved with graphite from Vandellos I. A second possibility under investigation is the encapsulation of the graphite in a long term stable glass matrix. The principal applicability has been already proved by FNAG. Crushed graphite mixed with a suitable glass powder has been pressed at elevated temperature under vacuum. The vacuum is required to avoid gas enclosures in the obtained product. The obtained products, named IGM for 'Impermeable Graphite Matrix', have densities above 99% of theoretical density. The amount of glass has been chosen with respect to the pore volume of the former graphite parts. The method allows the production of encapsulated graphite without increasing the disposal volume. This paper will give a short overview of characterisation results of different irradiated graphite materials obtained at CIEMAT and in the Carbowaste project as well as the proposed methods and the actual status of the program including first results about leaching of non-radioactive IGM samples and hopefully first tendencies concerning the C-14 separation from graphite of Vandellos I by thermal treatment. Both processes, the thermal treatment as well as the IGM, have the potential to solve problems related to the management of irradiated graphite in Spain. However the methods have only been tested with different types of i-graphite and virgin graphite, respectively. Only investigations with real i-graphite from Spain will reveal whether the described methods are applicable to graphite from Vandellos I. However all partners are convinced that one of these new methods or a combination of them will lead to a feasible option to manage i-graphite in Spain on an industrial scale. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Process and system for removing sulfur from sulfur-containing gaseous streams

A multi-stage UCSRP process and system for removal of sulfur from a gaseous stream in which the gaseous stream, which contains a first amount of H.sub.2S, is provided to a first stage UCSRP reactor vessel operating in an excess SO.sub.2 mode at a first amount of SO.sub.2, producing an effluent gas having a reduced amount of SO.sub.2, and in which the effluent gas is provided to a second stage UCSRP reactor vessel operating in an excess H.sub.2S mode, producing a product gas having an amount of H.sub.2S less than said first amount of H.sub.2S.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Process and system for removing sulfur from sulfur-containing gaseous streams

A multi-stage UCSRP process and system for removal of sulfur from a gaseous stream in which the gaseous stream, which contains a first amount of H.sub.2S, is provided to a first stage UCSRP reactor vessel operating in an excess SO.sub.2 mode at a first amount of SO.sub.2, producing an effluent gas having a reduced amount of SO.sub.2, and in which the effluent gas is provided to a second stage UCSRP reactor vessel operating in an excess H.sub.2S mode, producing a product gas having an amount of H.sub.2S less than said first amount of H.sub.2S.

Basu, Arunabha↗

Property Measurements of NaCl-UCl 3 and NaCl-KCl-UCl 3 Molten Salts (Rev.1)

Thermochemical and thermophysical property values of several salt compositions of interest are needed by molten salt reactor (MSR) developers to design, license, and operate their reactors. Thermochemical and thermophysical properties being measured at Argonne include thermal transitions, phase behavior, heat capacity, density, volumetric thermal expansion of the liquid phase, thermal diffusivity, thermal conductivity, and viscosity. Several properties of eutectic compositions in the ternary NaCl-KCl-UCl 3 and binary NaCl-UCl 3 systems that may be used by MSR developers as fuel bearing salts are being measured. A 65.8 mol % NaCl–34.2 mol % UCl 3 mixture and a near-eutectic mixture of 50.9 mol % NaCl–24.4 mol % KCl–24.7 mol % UCl 3 were synthesized and the thermochemical properties of the mixtures were measured by using differential scanning calorimetry (DSC). The measured transition temperatures were compared to transition temperatures predicted using two models. A thermodynamic model of the binary NaCl-UCl 3 system was constructed using data in the Molten Salt Thermal Properties Database–Thermochemical Version 2.0 (MSTDB-TC V2.0). A ternary NaClKCl-UCl 3 system model constructed at Argonne and was described in a previous report. These comparisons can be used to validate the models. Thermophysical property values of molten salts are needed to model how salt retains and transfers heat in an MSR system. These property values are essential to the entire MSR design because molten salt is used as both the fuel and the coolant material in a salt fueled reactor. Heat capacity of the synthesized NaCl-UCl 3 and NaCl-KCl-UCl 3 salt mixtures was measured by using DSC and thermal diffusivity was measured by using laser flash analysis (LFA) at temperatures spanning the typical operating range of an MSR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Study on main control room and human-system interface of generation III in China - 313

This paper focuses on the study on Main Control Room (MCR) and Human-System Interface (HSI) of Generation III in China. An intelligent HSI has been developed to enhance the safety and availability of Nuclear Power Plant (NPP) by improving operational reliability. The key elements of the proposed HSI such as Advanced Alarm System, State Oriented Procedures (SOP), Large Display Panel (LDP), Computerized-base procedures..., that affects what information the operator sees or the system's response to a control input must be empirically evaluated to ensure that the new design does not compromise HSI effectiveness. Based on CPR1000's experience in China, this paper presents the approach used as well as the most relevant aspects of this kind of project for the next generation. This approach will be used in new Generation III nuclear power plant, and also used in modernizing I and C system in currently operative nuclear power plants, in addition to meeting safety requirements and the plant's operational requirements, to improve cost-effective plant and human performance and to reduce likelihood of human errors, to gain maximum benefit of the implemented technology and to increase the performance, resulting in improved plant safety, availability, reliability, and cost-effective operation. The proposed HSI has been validated and demonstrated using the CPR1000 simulator of National Key Laboratory. After sufficient validation, the characteristic design features of the proposed HSI will be reflected in the design of the main control room of the next generation reactors in China. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Coupled Decay Heat and Thermal Hydraulic Capability for Loss-of-Coolant Accident Simulations

As the nuclear energy industry considers ways to achieve improved economics in the current fleet of light-water reactors (LWRs), one possible approach is to operate each cycle for longer durations. This causes a greater portion of the fuel to be burned and reduces the frequency of outages, which ultimately reduces the cost to operate the reactor. However, this also leads to higher burnup fuels than has traditionally been allowed in these reactors. Thus, there are concerns about integrity of high-burnup (HBu) fuel, especially during accident conditions such as loss-of-coolant accidents (LOCAs), as shown by Capps et al.. To investigate these concerns, advanced modeling and simulation capabilities are being leveraged to determine the susceptibility of HBu fuel to fuel fragmentation, relocation, and dispersion (FFRD). Improvements have previously been made to fuel performance capabilities to more accurately model these phenomena; multiphysics simulations have also been conducted to determine the power and burnup histories of the HBu fuel, which are needed as inputs for the fuel performance calculations. Most recently, new statistical approaches have been developed to identify a subset of fuel rods that have greater FFRD susceptibility, reducing the total number of fuel performance simulations required. Prior LOCA simulations have relied on the TRACE systems code, which can model the core and primary loop during accident conditions. TRACE includes many models for various aspects of the primary loop, but two sets of models are important for this report. First, TRACE uses a lumped-fuel approach for modeling the core. This approximates the ~50,000 fuel rods in the core with a much smaller number of rods. The rods can be lumped in various ways as determined by the user. For example, one lumped rod may be used to represent all rods in an assembly, sometimes with an additional rod representing the hottest fuel rod. However, due to runtime constraints and complexity of modeling, a more common approach is to group several assemblies or larger regions of the core into single lumped rods. These lumping schemes apply not only to fuel rods but to flow channels as well. Second, TRACE has several different models for treating decay heat, ranging from pregenerated decay heat curves based on an ANSI/ANS-5.1 standard (hereinafter abbreviated simply as ANSI) to explicit time-dependent heat inputs from the user. None of these models account for differences in isotopics between different rods, which is an approximation the work in this report seeks to eliminate. This report focuses on the implementation of coupled decay heat capabilities in the Virtual Environment for Reactor Applications (VERA) code suite to address a gap identified in previous LOCA simulations. This constitutes an improvement for both the lumped-fuel and decay heat models in TRACE. VERA has been developed to perform high-fidelity, whole-core multiphysics simulations for LWRs. Previously, during the Consortium for Advanced Simulation of LWRs (CASL) program, the emphasis was on providing accurate steady-state analysis—with a secondary focus on reactivity insertion accident (RIA) analysis—to address operational challenges in the nuclear energy industry. Under the Department of Energy (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, these capabilities are being extended to a broader range of transient analyses with the goal of quantifying the risk of fuel failures such as FFRD. To properly model such conditions with VERA, decay heat calculations have been integrated with the multiphysics to enable rod-by-rod thermal hydraulic (TH) conditions to be driven by the decay heat in long-running accidents such as LOCAs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Correlation of rates of tritium migration through porous concrete

In a nuclear facility when tritium leaks from a glovebox to room accidentally, an atmosphere detritiation system (ADS) starts operating, and HTO released is recovered by ADS. ADS starts when tritium activity in air becomes higher than its controlled level. Before ADS operates, the laboratory walls are the final enclosure facing tritium and are usually made of porous concrete coated with a hydrophobic paint. In the present study, previous data on the diffusivity and adsorption coefficient of concrete and paints are reviewed. Tritium penetrates and migrates into concrete by following 3 ways. First, gaseous HT or T{sub 2} easily penetrates into porous concrete. Its diffusivity is almost equal to that of H{sub 2}. When a gaseous molecule diffuses through pores with a smaller diameter than a mean free path, its migration rate is described by the Knudsen diffusion formula. The second mechanism is H{sub 2}O vapor diffusion in pores. Concrete holds a lot of structural water. Therefore, H{sub 2}O or HTO vapor can diffuse inside concrete pores along with adsorption-desorption and isotopic exchange with structural water, which is the third mechanism. Literature shows that the diffusivity of HTO through the epoxy-resin paint is determined as D(HTO)=1.0*10{sup -16} m{sup 2}/s. We have used this data to set a model and we have applied it to estimate residual tritium in laboratory walls. We have considered 2 accidental cases and a normal case: first, ADS starts operating 1 hour after 100 Ci HTO is released in the room, secondly, ADS starts 24 hours after 100 Ci HTO release and thirdly, when the walls are exposed to HTO for 10 years of normal operation. It appears that the immediate start up of ADS is indispensable for safety.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Independent Confirmatory Survey Report for the University of Arizona Nuclear Reactor Laboratory, Tucson, Arizona

The University of Arizona (University) research reactor is a TRIGA swimming pool type reactor designed by General Atomics and constructed at the University in 1958. The reactor first went into operation in December of 1958 under U.S. Nuclear Regulatory Commission (NRC) license R-52 until final shut down on May 18, 2010. Initial site characterization activities were conducted in February 2009 during ongoing reactor operations to assess the radiological status of the Nuclear Reactor Laboratory (NRL) excluding the reactor tank, associated components, and operating systems. Additional post-shutdown characterization activities were performed to complete characterization activities as well as verify assumptions made in the Decommissioning Plan (DP) that were based on a separate activation analysis (ESI 2009 and WMG 2009). Final status survey (FSS) activities began shortly after the issuance of the FSS plan in May 2011. The contractor completed measurement and sampling activities during the week of August 29, 2011.