Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Consumer Guide to Residential Solar Rooftop Potential

Learn about tools to estimate solar rooftop potential, or the amount of solar that could be installed on a residential or commercial rooftop. This fact sheet from Energy Saver also includes information about how installers estimate solar potential and why it's important.

solar, solar rooftop potential, Energy Saver↗

PCM Selection for Heat Pump Integrated with Thermal Energy Storage for Demand Response in Residential Buildings

Phase Change Materials (PCM) based Thermal energy storage (TES) is a widespread solution to shift buildings’ peak energy demand and add stability to the grid. PCMs can be used for space heating and cooling applications in residential buildings by integrating into the heat pump equipment or building envelope via several possible configurations. The heat pump integrated active PCM storage can provide significant energy savings and reduce peak demand, but the benefits vary substantially depending on the system configuration, storage capacity, and the temperature range of the PCM used. It is critical to provide a review of the materials and their suitability in heat pump integrated PCM systems. This paper will present an analysis of the PCM material selection for heat pump integrated TES in various configurations. The comprehensive review will compare the phase change materials with different melting temperatures, and configurations, corresponding to the energy savings and demand impact reported in the literature. This work is significant to guide the design of high-performance heat pump integrated PCM systems.

Sultan, Sara↗

User Friendly Web-Based Tool to Assess the Energy Efficiency and Durability of Residential Wall Retrofits

According to the U.S. Department of Energy Windows and Building Envelope Research and Development Roadmap for Emerging Technologies, building envelope wall energy loss in the United States accounts for about 5.9 x 1010 kWh or 2 quads of energy annually, costing homeowners and occupants billions of dollars. Enclosure retrofits targeting these losses can save significant energy, reduce greenhouse gas emissions, and save occupants millions of dollars over time. Older homes, built before 1992 when DOE’s Building Energy Codes Program was established, represent approximately 68 percent of the residential building stock in the country, often having significant air leakage and inadequate insulation. Homes with little to no air sealing or insulation have heating and cooling losses that can represent a substantial portion of utility bills.High-performance building envelope retrofit systems are rarely selected for retrofit applications. Current solutions are expensive and/or unfamiliar to many designers, builders, contractors, and code officials and therefore are perceived as risky. The dominant perceived risk is durability specifically related to condensation and moisture accumulation in the building envelope component.The Building Science Advisor (BSA) is a rule-based expert system web-based tool that was originally developed to assist building professionals in designing energy efficient and durable wall systems for new construction. With the present focus being placed on upgrading the existing building stock, a retrofit module has been developed that, based on the location, existing construction, and planned retrofit strategy, provides recommendations on how to address the retrofit in a manner that will perform in accordance with IECC 2018 building code and not create a durability problem. This paper will describe the development of this tool and demonstrate its features and capabilities.

Desjarlais, Andre Omer↗

A review of the residential efficient lighting programme rollout in South Africa

Efficient lighting for the residential sector in South Africa stemmed out of an electricity supply crisis. The Compact Fluorescent Lamps (CFL) rollout programme was carried out in the absence of a supporting policy. The implementation resulted in both desirable and undesirable outcomes. Of even greater concern is that a section of the market may be regressing to inefficient lighting. An analysis of lighting technologies available in the market shows that a shift to more energy efficient lighting technologies, such as light-emitting diodes (LED), will result in significant energy savings.

Covary, T↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

A Peer-to-Peer Market-Based Control Strategy for a Smart Residential Community with Behind-the-Meter Distributed Energy Resources

This paper presents a distributed peer-to-peer market control strategy to manage and to enable resource sharing of behind-the-meter distributed energy resources in a residential community. In the proposed strategy, each consumer or prosumer determines the flexibility of their point of connection to the power network such that the obtained flexibility is network-feasible. Based on the feasible flexibility, the consumers and the prosumers trade power among each other at each time instance to fulfil their preferred load requirements while maximizing their payoffs and helping to regulate node voltages inside the community. Because the problem to be solved is non-convex, a distributed particle swarm optimization algorithm is used to coordinate the consumers/prosumers in a fully autonomous manner without any centralized or hierarchical coordination. Numerical simulations performed on a community of 48 homes demonstrate the efficacy of the proposed approach.

distributed energy resource↗

The Environmental Impact of Deep Energy Retrofits in Residential Construction

Almost two thirds of the residential homes in the U.S. were constructed before the Department of Energy implemented energy conservation measures that were later formalized in the building codes. To reduce energy consumption and carbon emissions from the built environment, improvement to the existing housing stock is a prerequisite. However, improvements that lower energy consumption address carbon emissions related to heating, cooling and plug loads but not the embodied carbon of the building materials that also contribute to global carbon emissions. As the enclosure is made more efficient a larger portion of total carbon emissions is embodied carbon from the building materials. To mitigate carbon emissions, a holistic approach is required so that any improvement to the home results in a net reduction in carbon emissions. To understand the overall environmental impact of building enclosure improvements, the embodied and operational carbon emissions are calculated in this investigation and compared to the overall energy savings associated with enclosure improvements. The energy savings together with a reduction in operational carbon emissions are calculated using a novel building envelope metric. The net carbon emissions are then determined before and after the energy improvement measures. This approach allows or enables architects and builders to select designs that result in maximizing the overall reduction in energy and carbon emissions.

Aldykiewicz Jr, Antonio↗

Unique Construction and Social Experiences in Residential Remediation Sites - 13423

Sevenson Environmental Services, Inc., (Sevenson) has performed several radiological remediation projects located in residential urban areas. Over the course of these projects, there has been a wide variety of experiences encountered from construction related issues to unique social situations. Some of the construction related issues included the remediation of interior basements where contaminated material was located under the footers of the structure or was used in the mortar between cinder block or field stone foundations. Other issues included site security, maintaining furnaces or other utilities, underpinning, backfilling and restoration. In addition to the radiological hazards associated with this work there were occupational safety and industrial hygiene issues that had to be addressed to ensure the safety and health of neighboring properties and residents. The unique social situations at these job sites have included arson, theft/stolen property, assault/battery, prostitution, execution of arrest warrants for residents, discovery of drugs and paraphernalia, blood borne pathogens, and unexploded ordnance. Some of these situations have become a sort of comical urban legend throughout the organization. One situation had historical significance, involving the demolition of a house to save a tree older than the Declaration of Independence. All of these projects typically involve the excavation of early 20. century items such as advertisement signs, various old bottles (milk, Listerine, perfume, whisky) and other miscellaneous common trash items. (authors)

54 ENVIRONMENTAL SCIENCES↗

AI-Based Optimal Design and Controls Can Greatly Reduce Carbon Emissions and Enhance Resilience in Residential Communities in Cold Climates

Net-zero energy residential communities are crucial for achieving decarbonization goals, but the high-penetration photovoltaic (PV) in those communities is posing challenges to the distribution grid. Traditional design and operation of net-zero communities rely on rule-of-thumb methods and may not work in complex scenarios. Artificial intelligence and machine learning methods can optimally size PV for net-zero energy, identify user preferences and usage patterns, and fully unlock the potential of distributed energy resources to address distribution grid issues.

artificial intelligence↗

Remediation of Residential Properties Contaminated with LLRW as Part of the Port Hope Area Initiative - 17456

The Port Hope Area Initiative (PHAI) is a community-based solution for the long-term management of historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. The Eldorado refinery, on the shores of Lake Ontario, began refining Ra-226 from pitchblende ore, later transitioning to the refining of uranium ore. Within the community of Town of Port Hope, surveys are being conducted at approximately 5000 individual properties to identify the presence of LLRW resulting from fugitive emissions from the refinery and/or the use of refinery residue as construction backfill within the community. Of the 5000 properties being surveyed, it is expected that approximately 10% will contain some degree of LLRW requiring physical remediation. The design phase for remediation of the first group of 44 residential properties to be included in the small scale sites program and the various challenges associated with working in a well-established community are presented. In developing the design packages for individual properties it is important to understand that this remedial phase represent the final and most intrusive aspect of the PHAI for those homeowners affected. As such, the success of the program is dependent on how well the needs and desires of the community and individual property owners are incorporated into the remedial designs and how well those designs are implemented to remove LLRW and restore properties to their original (or better) condition. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FUSRAP Maywood Site - Remediation of a Residential Property at 61 Trudy Drive, Lodi, NJ - 17533

The Formerly Utilized Sites Remedial Action Program (FUSRAP) is the U.S. government program started in 1974 to identify, investigate and clean up or control sites that became contaminated as a result of the nation's early atomic programs. The FUSRAP Maywood (New Jersey) Superfund Site (FMSS) consists of 92 designated property parcels known as vicinity properties. 61 Trudy Drive in Lodi, New Jersey is one such vicinity property. Construction planning for a recently-completed remedial excavation at 61 Trudy Drive was predicated on a fundamental question: to remediate the property with the existing home remaining in place or to demolish the exiting home. Answering this question involved detailed engineering and cost analyses, programmatic considerations, and stakeholder input. 61 Trudy Drive was originally addressed under FUSRAP in 1985 by the U.S. Department of Energy (DOE). However, subsequent remediation on an adjacent property by the U.S. Army Corps of Engineers (USACE) in 1998 suggested that residual contamination remained at depth at 61 Trudy. The property owner at that time declined to allow FUSRAP access to the property. However, a property transfer in 2012 presented USACE with an opportunity to address this property. Characterization of the property began in 2013; remedial activities were completed in 2015. The 61 Trudy Drive remediation required an intensive stakeholder communications program tailored for several audiences, including the affected property owner, local government officials and the neighboring community This paper will present the FUSRAP history at 61 Trudy Drive, to provide context for recent FUSRAP actions there. It will then focus on the challenges and complexities of performing environmental remediation in a suburban residential setting, focusing on both construction and communications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Colonie FUSRAP Site - Radioactive Dust Sampling of Residential and Commercial Properties - 16384

The Colonie Formerly Utilized Sites Remedial Action Program (FUSRAP) Site is located in the Town of Colonie, Albany County, New York. The U.S. Army Corps of Engineers (USACE) is currently addressing environmental contamination associated with the Site. The area surrounding the Site consists of residential and commercial properties, known as vicinity properties (VPs). Cleanup activities have been completed on many of these VPs under the FUSRAP to address depleted uranium contamination. Soil remediation activities have been substantially completed at the Colonie FUSRAP Site and its VPs under the FUSRAP. Recent studies performed by an independent party and under FUSRAP identified uranium within indoor dust in residencies and businesses in the immediate vicinity of the Site. The studies were limited to non-living areas such as basement window sills, garages, and attics. This paper discusses the indoor dust sampling and analysis, in support of the Remedial Investigation (RI) for the VPs, and presents sampling results. The indoor dust sample media presented many technical challenges regarding sampling design, data reduction, and data interpretation. In addition, because the RI is focused on numerous resident-owned, rental, and commercial properties, challenges where presented regarding right-of-entry to sample. Isotopic uranium ratios observed in the majority of the samples are indicative of the depleted uranium contaminant, even at trace levels. While the sampling and analysis methods were effective at identifying depleted uranium in the majority of the samples, preliminary property-specific risk assessment results do not indicate the presence of depleted uranium in sufficient concentrations to pose unacceptable risk to VP inhabitants. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Remediation Residential Properties Contaminated with LLRW as Part of the Port Hope Area Initiative - The Importance of Effective Community Consultation - 18591

The Port Hope Area Initiative (PHAI) is a community-based solution for the long-term management of historic low level radioactive waste (LLRW) resulting from 60 years of uranium and radium processing operations in the urban setting of Port Hope, Ontario. The Eldorado refinery, on the shores of Lake Ontario, began refining radium-226 from pitchblende ore, later transitioning to the refining of uranium ore. Process residues were deposited at the Welcome Waste Management Facility in the Municipality of Port Hope until the mid-1950's switching to the Port Granby Waste Management Facility (PGWMF), which continued to accept waste until the late 1980's. Within the community of Port Hope, surveys are being conducted at approximately 4800 individual properties to identify the presence of LLRW resulting from fugitive emissions from the refinery and/or the use of refinery residue as construction backfill within the community. Identification of the presence of LLRW is based on multiple lines of evidence including reviews of historical information, gamma radiation surveys and physical sampling of soil for the presence of four signature contaminants. Of the 4800 properties being surveyed, it is expected that approximately 10% will contain some degree of LLRW requiring physical remediation. Many of the residences requiring remediation will require extensive soil removal, removal and restoration of outbuildings, fences and other structures, and the removal of mature trees, hedges and decorative gardens. For the property owners involved this phase represents the final and most intrusive aspect of the program. As such, the remedial designs must be sensitive to the needs of the community and individual property owners taking into consideration factors such as the need to minimize the disturbance to the neighborhood; maintaining geotechnical and structural stability of homes during excavations; removal and restoration of outbuildings affected by LLRW; removal and replacement of landscaping features (decks, fences, pools etc) and mature trees; radiation protection during earthworks; control of dust and noise; and maintaining safe access by residents. As Community satisfaction is a key metric for the success of the project, constant and effective communication at all stages of the project is necessary to ensure the residents understand the nature and extent of work to be undertaken; any and all inconveniences they can expect during the work; contingencies to deal with those inconveniences (e.g. parking, garbage collection etc); measures to protect their health and safety; scheduling; and what their property will look like at the completion of works. This paper provides an overview of the residential remediation program in Port Hope and describes the consultation efforts with property owners that are integral to the development of final designs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Downscaling Synthetic Populations to Realistic Residential Locations

High-fidelity pattern of life (PoL) models require realistic origin points for predictive trip modeling. This paper develops and demonstrates a reproducible method using open data to match synthetic populations generated from census surveys to plausible residential locations (building footprints) based on housing attributes. This approach presents promise over extant methods based on housing density, particularly in small neighborhood areas with heterogeneous land-use.

Tuccillo, Joe↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Residential Integrated Heat Pump to Meet All the Home Comfort Needs

This paper will introduce development and field trial of a residential air-source integrated heat pump for cold climates. The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating. The integrated heat pump is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency > 30.0 EER and required only 25 minutes to heat a 50-gallon tank of water. One heat pump prototype is going through a field trial since April, 2023 in Syracuse, New York. The one-year field test results are summarized.

Shen, Bo↗