Grating-based phase contrast tomosynthesis imaging: Proof-of-concept experimental studies

Purpose: This paper concerns the feasibility of x-ray differential phase contrast (DPC) tomosynthesis imaging using a grating-based DPC benchtop experimental system, which is equipped with a commercial digital flat-panel detector and a medical-grade rotating-anode x-ray tube. An extensive system characterization was performed to quantify its imaging performance. Methods: The major components of the benchtop system include a diagnostic x-ray tube with a 1.0 mm nominal focal spot size, a flat-panel detector with 96 μm pixel pitch, a sample stage that rotates within a limited angular span of ±30°, and a Talbot-Lau interferometer with three x-ray gratings. A total of 21 projection views acquired with 3° increments were used to reconstruct three sets of tomosynthetic image volumes, including the conventional absorption contrast tomosynthesis image volume (AC-tomo) reconstructed using the filtered-backprojection (FBP) algorithm with the ramp kernel, the phase contrast tomosynthesis image volume (PC-tomo) reconstructed using FBP with a Hilbert kernel, and the differential phase contrast tomosynthesis image volume (DPC-tomo) reconstructed using the shift-and-add algorithm. Three inhouse physical phantoms containing tissue-surrogate materials were used to characterize the signal linearity, the signal difference-to-noise ratio (SDNR), the three-dimensional noise power spectrum (3D NPS), and the through-plane artifact spread function (ASF). Results: While DPC-tomo highlights edges and interfaces in the image object, PC-tomo removes the differential nature of the DPC projection data and its pixel values are linearly related to the decrement of the real part of the x-ray refractive index. The SDNR values of polyoxymethylene in water and polystyrene in oil are 1.5 and 1.0, respectively, in AC-tomo, and the values were improved to 3.0 and 2.0, respectively, in PC-tomo. PC-tomo and AC-tomo demonstrate equivalent ASF, but their noise characteristics quantified by the 3D NPS were found to be different due to the difference in the tomosynthesis image reconstruction algorithms. Conclusions: It is feasible to simultaneously generate x-ray differential phase contrast, phase contrast, and absorption contrast tomosynthesis images using a grating-based data acquisition setup. The method shows promise in improving the visibility of several low-density materials and therefore merits further investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eye-tracking of nodule detection in lung CT volumetric data

Purpose: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. Methods: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. Results: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25–30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. Conclusions: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.

60 APPLIED LIFE SCIENCES↗

Jets with Variable R

We introduce a new class of infrared/collinear-safe and boost-invariant jet algorithms designed to return jets of variable angular size. In particular, we discuss an instance of these algorithms useful in reconstructing a commonly encountered type of event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reliable automatic alignment of tomographic projection data by passive auto-focus

Purpose: The authors present a robust algorithm that removes the blurring and double-edge artifacts in high-resolution computed tomography (CT) images that are caused by misaligned scanner components. This alleviates the time-consuming process of physically aligning hardware, which is of particular benefit if components are moved or swapped frequently. Methods: The proposed method uses the experimental data itself for calibration. A parameterized model of the scanner geometry is constructed and the parameters are varied until the sharpest 3D reconstruction is found. The concept is similar to passive auto-focus algorithms of digital optical instruments. The parameters are used to remap the projection data from the physical detector to a virtual aligned detector. This is followed by a standard reconstruction algorithm, namely the Feldkamp algorithm. Feldkamp et al.[J. Opt. Soc. Am. A 1, 612-619 (1984)]. Results: An example implementation is given for a rabbit liver specimen that was collected with a circular trajectory. The optimal parameters were determined in less computation time than that for a full reconstruction. The example serves to demonstrate that (a) sharpness is an appropriate measure for projection alignment, (b) our parameterization is sufficient to characterize misalignments for cone-beam CT, and (c) the procedure determines parameter values with sufficient precision to remove the associated artifacts. Conclusions: The algorithm is fully tested and implemented for regular use at The Australian National University micro-CT facility for both circular and helical trajectories. It can in principle be applied to more general imaging geometries and modalities. It is as robust as manual alignment but more precise since we have quantified the effect of misalignment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and application of upwind schemes on unstructured meshes

Solution and mesh generation algorithms for solving the Euler equations on unstructured meshes consisting of triangle and quadrilateral control volumes are presented. Cell-centered and mesh-vertex upwind finite-volume schemes are developed which utilize multi-dimensional monotone linear reconstruction procedures. These algorithms differ from existing algorithms (even on structured meshes). Numerical results in two dimensions are presented.

Barth, Timothy J.↗

Portable Data-Parallel Surface Reconstruction on a Uniform Rectilinear Grid

With the increasing heterogeneity and on-node parallelism of high-performance computing hardware, a major challenge is to develop portable and efficient algorithms and software. In this work, we present our implementation of a portable code to perform surface reconstruction using NVIDIA's Thrust library. Surface reconstruction is a technique commonly used in volume tracking methods for simulations of multimaterial flow with interfaces. Here, we have designed a 3D mesh data structure that is easily mapped to the 1D vectors used by Thrust and at the same time is simple to use and uses familiar data structure terminology (such as cells, faces, vertices, and edges). With this new data structure in place, we have implemented a piecewise linear interface reconstruction algorithm in 3 dimensions that effectively exploits the symmetry present in a uniform rectilinear computational cell. Finally, we report performance results, which show that a single implementation of these algorithms can be compiled to multiple backends (specifically, multi-core CPUs, NVIDIA GPUs, and Intel Xeon Phi processors), making efficient use of the available parallelism on each. We also compare performance of our implementation to a legacy FORTRAN implementation in Message Passing Interface (MPI) and show performance parity on single and multi-core CPU and achieved good parallel speed-ups on GPU. In conclusion, our research demonstrates the advantage of performance portability of the underlying data-parallel programming model.

97 MATHEMATICS AND COMPUTING↗

Quantification and visualization of uncertainties in reconstructed penumbral images of implosions at Omega

Penumbral imaging is a technique used in plasma diagnostics in which a radiation source shines through one or more large apertures onto a detector. To interpret a penumbral image, one must reconstruct it to recover the original source. The inferred source always has some error due to noise in the image and uncertainty in the instrument geometry. Interpreting the inferred source thus requires quantification of that inference’s uncertainty. Markov chain Monte Carlo algorithms have been used to quantify uncertainty for similar problems but have never been used for the inference of the shape of an image. Because of this, there are no commonly accepted ways of visualizing uncertainty in two-dimensional data. This paper demonstrates the application of the Hamiltonian Monte Carlo algorithm to the reconstruction of penumbral images of fusion implosions and presents ways to visualize the uncertainty in the reconstructed source. This methodology enables more rigorous analysis of penumbral images than has been done in the past.

Instruments & Instrumentation↗

Using SWIFT Data

SWIFT has been shown to be a promising new diagnostic tool with many applications. SWIFT diagnostics coupled with PDV and other tools represent an exciting new source of data. SIAS is the name for the methodology we use to couple our SWIFT data to calculations for maximum utilization. SIAS, formerly Schlieren Inverse Analysis Software -- now SWIFT Inverse Analysis Software, uses SWIFT data and a hydro code calculation repeated in a genetic algorithm loop to reconstruct pressure history of shock transducer material interface.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interpretation of laser/multi-sensor data for short range terrain modeling and hazard detection

A terrain modeling algorithm that would reconstruct the sensed ground images formed by the triangulation scheme, and classify as unsafe any terrain feature that would pose a hazard to a roving vehicle is described. This modeler greatly reduces quantization errors inherent in a laser/sensing system through the use of a thinning algorithm. Dual filters are employed to separate terrain steps from the general landscape, simplifying the analysis of terrain features. A crosspath analysis is utilized to detect and avoid obstacles that would adversely affect the roll of the vehicle. Computer simulations of the rover on various terrains examine the performance of the modeler.

Messing, B. S.↗

Experimental and Phenomenological Investigations of the MiniBooNE Anomaly

This thesis covers a range of experimental and theoretical efforts to elucidate the origin of the $4.8\sigma$ MiniBooNE low energy excess (LEE). We begin with the follow-up MicroBooNE experiment, which took data along the BNB from 2016 to 2021. This thesis specifically presents MicroBooNE's search for $\nu_e$ charged-current quasi-elastic (CCQE) interactions consistent with two-body scattering. The two-body CCQE analysis uses a novel reconstruction process, including a number of deep-learning-based algorithms, to isolate a sample of $\nu_e$ CCQE interaction candidates with $75\%$ purity. The analysis rules out an entirely $\nu_e$-based explanation of the MiniBooNE excess at the $2.4\sigma$ confidence level. We next perform a combined fit of MicroBooNE and MiniBooNE data to the popular $3+1$ model; even after the MicroBooNE results, allowed regions in $\Delta m^2$-$\sin^2 2_{\theta_{\mu e}}$ parameter space exist at the $3\sigma$ confidence level. This thesis also demonstrates that the MicroBooNE data are consistent with a $\overline{\nu}_e$-based explanation of the MiniBooNE LEE at the $<2\sigma$ confidence level. Next, we investigate a phenomenological explanation of the MiniBooNE excess combining the $3+1$ model with a dipole-coupled heavy neutral lepton (HNL). It is shown that a 500 MeV HNL can accommodate the energy and angular distributions of the LEE at the $2\sigma$ confidence level while avoiding stringent constraints derived from MINER$\nu$A elastic scattering data. Finally, we discuss the Coherent CAPTAIN-Mills experiment--a 10-ton light-based liquid argon detector at Los Alamos National Laboratory. The background rejection achieved from a novel Cherenkov-based reconstruction algorithm will enable world-leading sensitivity to a number of beyond-the-Standard Model physics scenarios, including dipole-coupled HNLs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Advanced Imaging Algorithms for Radiation Imaging Systems

Radiation-imaging devices are important to the nuclear security and safeguards communities due to their ability to detect and localize radioactive sources. Because of their low natural background, difficulty to shield, and unique association with SNM, fast-neutron imaging provides a promising means for the detection of SNM. To make these R&D systems useful for end-user applications, robust reconstruction and analysis algorithms must be developed that provide detailed information on the location, energy spectrum, and intervening material. To date, deconvolution, match filtering, and MLEM have been demonstrated. However, the information provided is limited to an approximate location of the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular Dependence of Drell-Yan in the SeaQuest Experiment using Deep Neural Network-Based Reconstruction

The SeaQuest and SpinQuest experiments at Fermilab were designed to probe the internal dynamics of protons and neutrons via the angular dependence of muons created by colliding 120 GeV protons into stationary targets. To do this, it is necessary to translate the detector data into coherent information about the particles detected in the experiment. This dissertation describes the development and implementation of QTracker, a neural network-based algorithm designed to reconstruct muons. The application of QTracker to experimental data yields improved reconstruction of muon tracks, allowing for a more precise investigation of the transverse momentum distributions and angular modulations in the Drell-Yan process. This work highlights the potential of neural network-based methods to advance particle tracking and enhance our understanding of nucleon structure.

Conover, Arthur↗

An optical-input Maximum Likelihood Estimation feedback system demonstrated on tokamak horizontal equilibrium control

A readily parallelized Maximum Likelihood Estimation (MLE) algorithm with linear computational complexity is demonstrated in real time using only measurements from an extreme ultraviolet (EUV) diagnostic to control the horizontal position of a tokamak plasma. A set of trial emissivity profiles are parameterized by the control quantity of interest (R m ), and the MLE is identified from the profile which minimizes the signal reconstruction residual. The algorithm depends on an empirically determined likelihood function with exponential form. EUV emission (λ ≈ 15eV-1keV) is captured in a poloidal plane by four 16-channel AXUV diodes mounted at different poloidal angles with radial and angular resolution sufficient to discern plasma equilibrium evolution in HBT-EP. Calculations of the plasma major radius by the system are consistent within diagnostic uncertainty for the majority of the discharge with those of: a weighted average of vertical soft X-ray or EUV chords, magnetic sensors, and an equilibrium reconstruction. The feedback system corrects for a horizontal displacement of the major radius equal to 20% of the plasma minor radius by adjusting the vertical field produced from 40 in-vessel control coils in real time. The MLE calculation is performed on a GPU in a 15 μs cycle, with similar performance in this application to a simple weighted average of vertical chords. Finally, results demonstrate horizontal position control using magnetic actuators and an optical observer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative evaluation of mask phase defects from through-focus EUV aerial images

Mask defects inspection and imaging is one of the most important issues for any pattern transfer lithography technology. This is especially true for EUV lithography where the wavelength-specific properties of masks and defects necessitate actinic inspection for a faithful prediction of defect printability and repair performance. In this paper we will present a technique to obtain a quantitative characterization of mask phase defects from EUV aerial images. We apply this technique to measure the aerial image phase of native defects on a blank mask, measured with the SEMATECH Berkeley Actinic Inspection Tool (AIT) an EUV zoneplate microscope that operates at Lawrence Berkeley National Laboratory. The measured phase is compared with predictions made from AFM top-surface measurements of those defects. While amplitude defects are usually easy to recognize and quantify with standard inspection techniques like scanning electron microscopy (SEM), defects or structures that have a phase component can be much more challenging to inspect. A phase defect can originate from the substrate or from any level of the multilayer. In both cases its effect on the reflected field is not directly related to the local topography of the mask surface, but depends on the deformation of the multilayer structure. Using the AIT, we have previously showed that EUV inspection provides a faithful and reliable way to predict the appearance of mask defect on the printed wafer; but to obtain a complete characterization of the defect we need to evaluate quantitatively its phase component. While aerial imaging doesn't provide a direct measurement of the phase of the object, this information is encoded in the through focus evolution of the image intensity distribution. Recently we developed a technique that allows us to extract the complex amplitude of EUV mask defects using two aerial images from different focal planes. The method for the phase reconstruction is derived from the Gerchberg-Saxton (GS) algorithm, an iterative method that can be used to reconstruct phase and amplitude of an object from the intensity distributions in the image and in the pupil plane. The GS algorithm is equivalent to a two-parameter optimization problem and it needs exactly two constraints to be solved, namely two intensity distributions in different focal planes. In some formulations, adding any other constraint would result in an ill posed problem. On the other hand, the solution's stability and convergence time can both be improved using more information. We modified our complex amplitude reconstruction algorithm to use an arbitrary number of through focus images and we compared its performance with the previous version in terms of convergence speed, robustness and accuracy. We have demonstrated the phase-reconstruction method on native, mask-blank phase defects and compared the results with phase-predictions made from AFM data collected before and after the multilayer deposition. The method and the current results could be extremely useful for improving the modeling and understanding of native phase defects, their detectability, and their printability.

36 MATERIALS SCIENCE↗