Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reflector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Astrometric investigations at the Vienna Observatory and astrometric plans for the 60 inch reflector of the L. Figl Observatory

A short discussion of the astrometric instruments at the Vienna Observatory is given. The essential features of design and organization of the planned 60 inch telescope are described. Furthermore, several points of view concerning modern astrometry are discussed, especially the usefulness of comparing astrometric results based upon different instruments, for instance the comparison between mirrors and refractor based data. Some examples are given together with new immediate results. Lastly, as far as possible at this moment astrometric plans for the new telescope are formulated.

Meurers, J.↗

Analysis of requirements for GEOS-C laser cube-corner reflector panels

A mathematical analysis of the tradeoffs and requirements was performed to develop an improved array design which will give stronger returns at lower elevation angles and reduce pulse spread in the return. It was determined that a zenith angle of 75deg can be obtained with an array with an area of 0.28 sq m, if the array is shaped on the surface of a 45 deg cone whose axis is coincident to the satellite axis. The total weight of the truncated pyramid array with 270 cube corners is calculated to be not more than 50% greater than the GEOS 2 array, while the efficiency is increased 275%.

Minott, P. O.↗

Gamma heating in reflector heat shield of gas core reactor

Heating rate measurements made in a mock-up of a BeO heat shield for a gas core nuclear rocket engine yields results nominally a factor of two greater than calculated by two different methods. The disparity is thought to be caused by errors in neutron capture cross sections and gamma spectra from the low cross-section elements, D, O, and Be.

Lofthouse, J. H.↗

Single reflector interference spectrometer and drive system therefor

In a Fourier interference spectrometer of the doublepass retroreflector type, a single mirror is employed in the path of both split beams of an incoming ray to cause them to double back through separate retroreflectors. Changes in optical path length are achieved by linear displacement of both retroreflectors using a motor driven lead screw on one for large, low frequency changes, a moving-coil actuator on the other for smaller, mid-frequency changes and a piezoelectric actuator on one of these two for small, high frequency changes.

Schindler, R. A.↗