Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Doing Your Science While You're in Orbit

Abstract. Large-scale neutron facilities such as the Spallation Neutron Source (SNS) located at Oak Ridge National Laboratory need easy-to-use access to Department of Energy Leadership Computing Facilities and experiment repository data. The Orbiter thick- and thinclient and its supporting Service Oriented Architecture (SOA) based services (available at https://nucleus.sns.gov) consist of standards-based components that are reusable and extensible for accessing high performance computing, data and computational grid infrastructure, and cluster-based resources easily from a user configurable interface. The primary Orbiter system goals consist of (1) developing infrastructure for the creation and automation of virtual instrumentation experiment optimization, (2) developing user interfaces for thin- and thickclient access, (3) provide a prototype incorporating major instrument simulation packages, and (4) facilitate neutron science community access and collaboration. The secure Orbiter SOA authentication and authorization is achieved through the developed Virtual File System (VFS) services, which use Role-Based Access Control (RBAC) for data repository file access, thinand thick-client functionality and application access, and computational job workflow management. The VFS Relational Database Management System (RDMS) consists of approximately 43 database tables describing 429 user accounts with 437 groups over 451,000 directories with 739,618 repository files. Over 39 million NeXus file metadata records are associated to the 12,794 unique NeXus file field/class names generated from the 42,894 repository NeXus files. Services that enable (a) summary dashboards of data repository status with Quality of Service (QoS) metrics, (b) data repository NeXus file field/class name full text search capabilities within a Google like interface, (c) fully functional RBAC browser for the read-only data repository and shared areas, (d) user/group defined and shared metadata for data repository files, (e) user, group, repository, and web 2.0 based global positioning with additional service capabilities are currently available. The SNS based Orbiter SOA integration progress with the Distributed Data Analysis for Neutron Scattering Experiments (DANSE) software development project is summarized with an emphasis on DANSE Central Services and the Virtual Neutron Facility (VNF). Additionally, the DANSE utilization of the Orbiter SOA authentication, authorization, and data transfer services best practice implementations are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNS second target station moderator performance update

In its first years of operations of its first target station, the Spallation Neutron Source (SNS) is working towards a facility upgrade by a megawatt-class second target station operated at 20 Hz repetition rate, which is intended to complement the existing ORNL neutron sources, the first SNS target station and the HFIR reactor, with high-intensity cold neutron beams.The first round of optimization calculations converged on larger-volume cylindrical para-hydrogen moderators placed in wing configuration on top and bottom of a flat mercury target, pre-moderated by layers of ambient water and surrounded by beryllium reflector. The metric of these optimization calculations was time-averaged and energy-integrated neutron brightness below 5 meV with the requirement to be able to serve 20 ports with neutrons. A summary of these calculations will be given including lessons learned from the variety of simulated configurations and detailed neutron performance characteristics like spectral intensities, emission time distributions, local variations of moderator brightness at the viewed areas, and sensitivity of the optimization metric to optimized parameters for the most promising configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SNS target reaches end-of-life

On Sunday, April 3, 2011, the Spallation Neutron Source (SNS) target reached an end-of-life condition, so user operations were shut down to change the stainless steel target housing the liquid mercury. This is the third change out of the target vessel; it is an expected event and took about two weeks. We took advantage of this time to do maintenance work that was planned for the longer summer shutdown. This will shorten that shutdown and recover the neutron production time. SNS restarted user operations on April 20.

36 MATERIALS SCIENCE↗

Instrument development continues in Oak Ridge

Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNS LINAC MODULATOR OPERATIONAL HISTORY AND PERFOMANCE

Fourteen High Voltage Converter Modulators (HVCM) were initially installed at the Spallation Neutron Source Linear Accelerator (SNS Linac) at the Oak Ridge National Laboratory in 2005. A fifteenth HVCM was added in 2009. Each modulator provides a pulse of up to 140 kV at a maximum width of 1.35 msec. Peak power level is 11 MW with an 8% duty factor. The HVCM system must be available for neutron production (NP) 24/7 with the exception being two, 6-week maintenance periods per year. HVCM reliability is one of the most important factors to maximize Linac availability and achieve SNS performance goals. During the last few years several modifications have been implemented to improve the overall system reliability. This paper presents operational history of the HVCM systems and examines failure mode statistical data since the modulators began operating at 60 Hz. System enhancements and upgrades aimed at providing long term reliable operation with minimal down time are also discussed in the paper.

43 PARTICLE ACCELERATORS↗

COMPUTATIONAL BEAM DYNAMICS STUDIES FOR IMPROVING THE RING INJECTION AND EXTRACTION SYSTEMS IN SNS

The ring injection and extraction systems must function as designed in order for the Spallation Neutron Source (SNS) to achieve its specified performance. In commissioning and early operations we have encountered problems that have been traced to these systems. We experienced high beam losses in and around the injection dump, the rectification of which has necessitated ongoing study and development by a multidisciplinary team. Results already include a number of enhancements of existing features and the addition of new elements and diagnostics. The problem in the extraction region stems from tilted beam distributions observed in the ring-to-target beam transport line (RTBT) and on the target, thus complicating the control of the beam-on-target distribution. This indicates the inadvertent introduction of x-y beam coupling somewhere upstream of the RTBT. The present paper describes computational studies, using the ORBIT Code, addressed at the detailed understanding and solution of these problems.

43 PARTICLE ACCELERATORS↗

COMPUTATIONAL BEAM DYNAMICS STUDIES OF COLLECTIVE INSTABILITIES OBSERVED IN SNS

During the commissioning and early operation of the Spallation Neutron Source, some physics shifts were set aside for high intensity stability studies. Under certain, especially contrived conditions, a number of beam instabilities were induced. These included both electron cloud and ring impedance driven phenomena. We are now applying both simple analytic models and the ORBIT Code to the description and simulation of these observed instabilities.

43 PARTICLE ACCELERATORS↗

HIGH INTENSITY EFFECTS IN THE SNS ACCUMULATOR RING

Currently operating at 0.5 MW beam power on target, the Spallation Neutron Source (SNS) is already the world's most powerful pulsed neutron source. However, we are only one third of the way to full power. As we ramp toward full power, the control of the beam and beam loss in the ring will be critical. In addition to practical considerations, such as choice of operating point, painting scheme, RF bunching, and beam scattering, it may be necessary to understand and mitigate collective effects due to space charge, impedances, and electron clouds. At each stage of the power ramp-up, we use all available resources to understand and to minimize beam losses. From the standpoint of beam dynamics, the losses observed so far under normal operating conditions have not involved collective phenomena. We are now entering the intensity regime in which this may change. In dedicated high intensity beam studies, we have already observed resistive wall, extraction kicker impedance-driven, and electron cloud activities. The analysis and simulation of this data are important ongoing activities at SNS. This paper discusses the status of this work, as well as other considerations necessary to the successful full power operation of SNS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton induced activation in mercury: Comparison of measurements and calculations

Measurements and simulations of the proton beam interaction with the mercury target were performed to support Spallation Neutron Source design. Due to the abundance of isotopes produced in mercury, the long delay between the irradiation and the measurements, and the self-shielding of the mercury sample, the measurements were difficult to perform and the activities of several isotopes have large uncertainties. Calculations predicted the activities of the most reliably measured isotopes within 20%/40%; however, some large discrepancies were observed for some isotopes for which the measurements were considered less reliable. Predicted dose rates were in very good agreement with the measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

H- ion source developments at the SNS

The U.S. Spallation Neutron Source (SNS) will require substantially higher average and pulse H- beam currents than can be produced from conventional ion sources such as the base line SNS source. H- currents of 40-50 mA (SNS operations) and 70-100 mA (power upgrade project) with an rms emittance of 0.20-0.35 Pi mm mrad and a ~7% duty factor will be needed. We are therefore investigating several advanced ion source concepts based on RF excitation. First, the performance characteristics of an external antenna source based on an Al2O3 plasma chamber combined with an external multicusp magnetic configuration, an elemental Cs system, and plasma gun will be discussed. Second, the first plasma measurements of a helicon-driven H- ion source will also be presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an RF Conditioning System for Charged-Particle Accelerators

Charged-particle accelerators use various vacuum windows on their accelerating radio-frequency (RF) cavities to throughput very high RF power. Before being placed on the cavities, the windows should be cleaned, baked, and fully RF conditioned to prevent a poor vacuum from outgassing, as well as other forms of contamination. An example is the coaxial fundamental power coupler (FPC) with an annular alumina ceramic window for each of the 81 superconducting RF cavities in the Spallation Neutron Source (SNS) linear accelerator. The FPCs needed to be tested up to 650-kW peak in a traveling wave and 2.6 MW with standing wave peaks in 1.3 and 60 pulses/s at 805 MHz. In this paper, an Experimental-Physics-and-Industrial-Control-System-based RF conditioning system for the SNS RF test facility is presented. This paper summarizes the hardware and software design strategies, provides the results obtained, and describes the future research scope.

43 PARTICLE ACCELERATORS↗

Progress in Creating Stabilized Gas Layers in Flowing Liquid Mercury

The Spallation Neutron Source (SNS) facility in Oak Ridge, Tennessee uses a liquid mercury target that is bombarded with protons to produce a pulsed neutron beam for materials research and development. In order to mitigate expected cavitation damage erosion (CDE) of the containment vessel, a two-phase flow arrangement of the target has been proposed and was earlier proven to be effective in significantly reducing CDE in non-prototypical target bodies. This arrangement involves covering the beam "window", through which the high-energy proton beam passes, with a protective layer of gas. The difficulty lies in establishing a stable gas/liquid interface that is oriented vertically with the window and holds up to the strong buoyancy force and the turbulent mercury flow field. Three approaches to establishing the gas wall have been investigated in isothermal mercury/gas testing on a prototypical geometry and flow: (1) free gas layer approach, (2) porous wall approach, and (3) surface-modified approach. The latter two of these approaches show success in that a stabilized gas layer is produced. Both of these successful approaches capitalize on the high surface energy of liquid mercury by increasing the surface area of the solid wall, thus increasing gas hold up at the wall. In this paper, a summary of these experiments and findings is presented as well as a description of the path forward toward incorporating the stabilized gas layer approach into a feasible gas/mercury SNS target design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Muon Muon Collider: Feasibility Study

A feasibility study is presented of a 2 + 2 TeV muon collider with a luminosity of L = 10{sup 35} cm{sup -2}s{sup -1}. The resulting design is not optimized for performance, and certainly not for cost; however, it does suffice - we believe - to allow us to make a credible case, that a muon collider is a serious possibility for particle physics and, therefore, worthy of R and D support so that the reality of, and interest in, a muon collider can be better assayed. The goal of this support would be to completely assess the physics potential and to evaluate the cost and development of the necessary technology. The muon collider complex consists of components which first produce copious pions, then capture the pions and the resulting muons from their decay; this is followed by an ionization cooling channel to reduce the longitudinal and transverse emittance of the muon beam. The next stage is to accelerate the muons and, finally, inject them into a collider ring wich has a small beta function at the colliding point. This is the first attempt at a point design and it will require further study and optimization. Experimental work will be needed to verify the validity of diverse crucial elements in the design. Muons because of their large mass compared to an electron, do not produce significant synchrotron radiation. As a result there is negligible beamstrahlung and high energy collisions are not limited by this phenomena. In addition, muons can be accelerated in circular devices which will be considerably smaller than two full-energy linacs as required in an e{sup +} - e{sup -} collider. A hadron collider would require a CM energy 5 to 10 times higher than 4 TeV to have an equivalent energy reach. Since the accelerator size is limited by the strength of bending magnets, the hadron collider for the same physics reach would have to be much larger than the muon collider. In addition, muon collisions should be cleaner than hadron collisions. There are many detailed particle reactions which are open to a muon collider and the physics of such reactions - what one learns and the necessary luminosity to see interesting events - are described in detail. Most of the physics accesible to an e{sup +} - e{sup -} collider could be studied in a muon collider. In addition the production of Higgs bosons in the s-channel will allow the measurement of Higgs masses and total widths to high precision; likewise, t{bar t} and W{sup +}W{sup -} threshold studies would yield m{sub t} and m{sub w} to great accuracy. These reactions are at low center of mass energy (if the MSSM is correct) and the luminosity and {Delta}p/p of the beams required for these measurements is detailed in the Physics Chapter. On the other hand, at 2 + 2 TeV, a luminosity of L {approx} 10{sup 35} cm{sup -2}s{sup -1} is desirable for studies such as, the scattering of longitudinal W bosons or the production of heavy scalar particles. Not explored in this work, but worth noting, are the opportunities for muon-proton and muon-heavy ion collisions as well as the enormous richness of such a facility for fixed target physics provided by the intense beams of neutrinos, muons, pions, kaons, antiprotons and spallation neutrons. To see all the interesting physics described herein requires a careful study of the operation of a detector in the very large background. Three sources of background have been identified. The first is from any halo accompanying the muon beams in the collider ring. Very carefully prepared beams will have to be injected and maintained. The second is due to the fact that on average 35% of the muon energy appears in its decay electron. The energy of the electron subsequently is converted into EM showers either from the synchrotron radiation they emit in the collider magnetic field or from direct collision with the surrounding material. The decays that occur as the beams traverse the low beta insert are of particular concern for detector backgrounds. A third source of background is e{sup +} - e{sup -} pair creation from {mu}{sup +} - {mu}{sup -} interaction. Studies of how to shield the detector and reduce the background are addressed in the Detector Chapter. Polarization of the muons allows many very interesting measurements which are discussed in the Physics Chapter. Unlike the electron collider in which the electron beam is highly polarized and the positron beam unpolarized, both muon beams may be partially polarized. It is necessary to select forward moving muons from the pion's decay and thus reduce the available number of muons and hence the luminosity. The necessary machine technology needed to achieve such a collider is discussed in the Option Chapter; at the moment it is not part of our point design, although such capability would almost certainly be incorporated into an actual device.

43 PARTICLE ACCELERATORS↗

LASER BASED DIAGNOSTICS FOR MEASURING H- BEAM PARAMETERS

In recent years, a number of laser based H- beam diagnostics systems have been developed in the Spallation Neutron Source (SNS). This talk reviews three types of laser-based diagnostics at SNS: the laser wire profile monitors at superconducting linac (SCL), the laser based transverse emittance measurement system at high energy beam transport (HEBT), and the laser bunch shape monitor at medium energy beam transport (MEBT). Measurement performance will be reported and major technical challenges in the design, implementation, and operation of the laser based diagnostics at accelerator facilities will be addressed.

43 PARTICLE ACCELERATORS↗

2011 U.S. National School on Neutron and X-ray Scattering

The 13th annual U.S. National School on Neutron and X-ray Scattering was held June 11 to 25, 2011, at both Oak Ridge and Argonne National Laboratories. This school brought together 65 early career graduate students from 56 different universities in the US and provided them with a broad introduction to the techniques available at the major large-scale neutron and synchrotron x-ray facilities. This school is focused primarily on techniques relevant to the physical sciences, but also touches on cross-disciplinary bio-related scattering measurements. During the school, students received lectures by over 30 researchers from academia, industry, and national laboratories and participated in a number of short demonstration experiments at Argonne's Advanced Photon Source (APS) and Oak Ridge's Spallation neutron Source (SNS) and High Flux Isotope Reactor (HFIR) facilities to get hands-on experience in using neutron and synchrotron sources. The first week of this year's school was held at Oak Ridge National Lab, where Lab director Thom Mason welcomed the students and provided a shitorical perspective of the neutron and x-ray facilities both at Oak Ridge and Argonne. The first few days of the school were dedicated to lectures laying out the basics of scattering theory and the differences and complementarity between the neutron and x-ray probes given by Sunil Sinha. Jack Carpenter provided an introduction into how neutrons are generated and detected. After this basic introduction, the students received lectures each morning on specific techniques and conducted demonstration experiments each afternoon on one of 15 different instruments at either the SNS or HFIR. Some of the topics covered during this week of the school included inelastic neutron scattering by Bruce Gaulin, x-ray and neutron reflectivity by Chuck Majkrazak, small-angle scattering by Volker Urban, powder diffraction by Ashfia Huq and diffuse scattering by Gene Ice.

43 PARTICLE ACCELERATORS↗

Neutron Studies of Tb2Mo2O7

We have used the new high energy resolution spectrometer (BaSiS), at the Spallation Neutron Source in Oak Ridge, to conclusively prove the existence of a low energy mode at 0.34(1) meV in the spin glass Tb{sub 2}Mo{sub 2}O{sub 7}. This mode is reminiscent of the excitation observed in the ordered phases of both Tb{sub 2}Ti{sub 2}O{sub 7} and Tb{sub 2}Sn{sub 2}O{sub 7}. The dynamical nature of the transition seen in the magnetization at {approx} 25 K suggests that this frustrated magnet shows a dynamic crossover between a high-temperature phase of poorly correlated, quickly relaxing spins to a low-temperature regime with much slower, short ranged spin correlations extending no further than to the next nearest neighbor. Existing theories explain the spin glass transition in terms of a phase transition and order parameters, and assume the existence of a distinct spin glass phase. There is no evidence for such a phase in Tb{sub 2}Mo{sub 2}O{sub 7}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

MODEL BASED ORBIT CORRECTION IN A DIAGNOSTICS DEFICIENT REGION

An orbit correction method is presented for a region where the number of beam position monitors is much less than the number of possible trajectory distortions points (quads). The method was developed for the Coupled Cavities Linac (CCL) part of the Spallation Neutron Source (SNS) linac. The orbit correction is very important in this region to minimize losses and activation, but a traditional orbit correction did not work here. The new method based on a realistic online model was developed. The procedure of a model parameters finding and results are discussed

43 PARTICLE ACCELERATORS↗

SNS BEAM COMMISSIONING TOOLS AND EXPERIENCE

The Spallation Neutron Source (SNS) successfully met the primary construction project completion milestones in April 2006. An important ingredient of this successful commissioning was the development and use of software tools. With the increasing digitalization of beam diagnostics and increasing complexity of Integrated Control Systems of large accelerators, the need for high level software tools is critical for smooth commissioning. At SNS a special Java based infrastructure called XAL was prepared for beam commissioning. XAL provides a hierarchal view of the accelerator, is data base configured, and includes a physics model of the beam. This infrastructure and individual applications development along with a historical time line of the SNS commissioning will be discussed.

43 PARTICLE ACCELERATORS↗