Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Dielectric measurements of nanoliter liquids with a photonic crystal resonator at terahertz frequencies

We present a highly sensitive technique for determining the complex permittivity of nanoliter liquid samples in the terahertz band based on a photonic crystal resonator and microcapillary. Liquids are characterized by using a capillary tube to introduce a ∼4 nl liquid sample into the electromagnetic field of a resonant mode confined by an L3 resonant cavity in a high-resistivity silicon photonic crystal slab. Monitoring the perturbation of the resonant frequency and unloaded Q-factor of the resonant mode at 100 GHz and ∼5800, respectively, allows a sample's permittivity to be calculated. An analytical model describing the system response based on perturbation theory and quasi-static analysis of the electric field within the capillary is also presented and found to agree well with FEM simulations and experimental measurements of ethanol-water mixtures of various concentrations for low to moderate loss tangents of the liquid samples. We demonstrate the utility of this approach by measuring the complex permittivity of several bioliquids, including suspensions of red and white blood cells. These results represent a step towards a lab-on-a-chip device for the analysis of extremely small quantities of biological, toxic, explosive, and other liquid types at terahertz frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The use of commercial and industrial waste in energy recovery systems - A UK preliminary study

Highlights: > Commercial and industrial waste samples collected. > Samples analysed for calorific value, moisture, ash and elemental composition. > Values similar to those of municipal solid waste and refuse derived fuel. > Sampled waste could be used in current energy recovery systems with minimal retrofitting. > Sampled waste could account 6.5% towards the UK's 2020 renewable electricity target if all qualifying waste is used. - Abstract: With 2020 energy targets set out by the EU fast approaching, the UK is trying to source a higher proportion of its energy from renewable resources. Coupled with this, a growing population and increasing trends in consumer demand have resulted in national waste loads increasing. A possible solution to both issues is energy-from-waste (EfW) technologies. Many studies have focused on municipal solid waste (MSW) as a potential feedstock, but appear to overlook the potential benefits of commercial and industrial waste (C and IW). In this study, samples of C and IW were collected from three North West waste management companies and Lancaster University campus. The samples were tested for their gross and net calorific value, moisture content, ash content, volatile matter, and also elemental composition to determine their suitability in EfW systems. Intra-sample analysis showed there to be little variation between samples with the exception two samples, from waste management site 3, which showed extensive variation with regards to net calorific value, ash content, and elemental analysis. Comparisons with known fuel types revealed similarities between the sampled C and IW, MSW, and refuse derived fuel (RDF) thereby justifying its potential for use in EfW systems. Mean net calorific value (NCV) was calculated as 9.47 MJ/kg and concentrations of sulphur, nitrogen, and chlorine were found to be below 2%. Potential electrical output was calculated using the NCV of the sampled C and IW coupled with four differing energy generation technologies. Using a conventional incinerator with steam cycle, total electrical output was calculated as 24.9 GWh, based on a plant operating at 100,000 tpa. This value rose to 27.0 GWh when using an integrated gasification combined cycle. A final aspect of this study was to deduce the potential total national electrical output if all suitable C and IW were to be used in EfW systems. Using incineration coupled with a steam turbine, this was determined to be 6 TWh, 1.9% of the national demand thereby contributing 6.5% towards the UK's 2020 renewable electricity target.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Trace explosive residue detection of HMX and RDX in post-detonation dust from an open-air environment

Explosives are often used in industry, geology, mining, and other applications, but it is not always clear what remains after a detonation or the fate and transport of any residual material. The goal of this study was to determine to what extent intact molecules of high explosive (HE) compounds are detectable and quantifiable from post-detonation dust and particulates in a field experiment with varied topography. We focused on HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazocane), which is less studied in field detonation literature, as the primary explosive material and RDX (1,3,5-Trinitroperhydro-1,3,5-triazine) as the secondary material. The experiment was conducted at Site 300, Lawrence Livermore National Laboratory’s Experimental Test Site, in California, USA. Two 20.4 kg and one 40.8 kg above ground explosions (primarily comprised of LX-14, an HMX-based polymer-bonded high explosive) were detonated on an open-air firing area on separate days. The complex terrain of the firing area (e.g., buildings, berm, low-height obstacles) was advantageous to study HE deposition in relation to plume dynamics. Three types of samples were collected up to 100 m away from each shot: surface swipes of aluminum plates, surface swipes of fixed objects, and filters from air samples. We used atmospheric flow tube-mass spectrometry (AFT-MS) to quantify picogram levels of molecular residue of HE material in the post-detonation dust. An aliquot of sample extract in methanol (e.g., 1 µL of 0.5 mL) was placed onto a resistive material and then thermally desorbed into the AFT-MS. We successfully detected and quantified both HMX and RDX in many of the samples. Based on mass (pg) detected and solution dilution, we back-calculated the mass collected on the swipe or filter (ng per sample). The aerial distribution of molecular residue was consistent with the path of the plume, which was strongly determined by wind speed and direction at the time of each shot. The quantity of material detected appeared to correlate more with distance from the shot and the wind conditions than with shot size. This study demonstrates that the picogram detection levels of AFT-MS are well-suited for quantification of analytes (e.g., HMX and RDX) in environmental samples.

atmospheric flow tube-mass spectrometry (AFT-MS), ↗

Greedy emulators for nuclear two-body scattering

Applications of reduced basis method emulators are increasing in low-energy nuclear physics because they enable fast and accurate sampling of high-fidelity calculations, enabling robust uncertainty quantification. Here, in this paper, we develop, implement, and test two model-driven emulators based on the (Petrov-)Galerkin projection using the prototypical test case of two-body scattering with the Minnesota potential and a more realistic local chiral potential. The high-fidelity scattering equations are solved with the matrix Numerov method, a reformulation of the popular Numerov recurrence relation for solving special second-order differential equations as a linear system of coupled equations. A novel error estimator based on reduced-space residuals is applied to an active learning approach (a greedy algorithm) to choosing training samples (“snapshots”) for the emulator and contrasted with a proper orthogonal decomposition (POD) approach. Both approaches allow for computationally efficient offline-online decompositions, but the greedy approach requires many fewer snapshot calculations. These developments set the groundwork for emulating scattering observables based on chiral nucleon-nucleon and three-nucleon interactions and optical models, where computational speed-ups are necessary for Bayesian uncertainty quantification. Our emulators and error estimators are widely applicable to linear systems.

Bayesian methods↗

An Atomic Mix Closure for Stochastic Media Transport Problems

The accurate modeling of stochastic media in radiation transport calculations remains on ongoing research challenge. The Levermore-Pomraning (LP) closure for the statistical transport equation is simple and inexpensive, but it is often inaccurate. More accurate closures have been proposed, but they can be prohibitively expensive. In this work we present a relatively inexpensive closure that we have observed to be more accurate than LP in almost all cases studied. Obtaining solutions to stochastic transport problems can be quite difficult. Transport calculations on an ensemble of explicit realizations generated by Monte Carlo sampling can be prohibitively expensive. Atomic mix or LP calculations are relatively inexpensive, but they can be inaccurate. The present work illustrates an approach that is less expensive than Monte Carlo sampling yet more accurate than atomic mix or LP approximations. We still need to analyze the reasons why the atomic mix closures derived for thicker problems lead to source iteration instabilities. It is not clear if the closure itself induces an ill-posed problem or if it is merely the iterative process that is problematic. We hope to examine alternative source terms to drive the subsidiary calculations. We also want to extend the work to multigroup and multidimensional problems. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoluminescence properties of Tb-Eu-Mn-codoped fluoroborate glasses under γ-irradiation

We report here an energy transfer from Tb{sup 3+} to Eu{sup 3+}, Mn{sup 2+} and Eu{sup 2+} to Tb{sup 3+} and Mn{sup 2+} for an un-irradiated and γ-irradiated B{sub 2}O{sub 3}-Al{sub 2}O{sub 3}-Na{sub 2}O-SrF{sub 2} glass samples, respectively. The blue emission from Eu{sup 2+} ions as well as green and red emission from Tb{sup 3+}, Eu{sup 3+}, and Mn{sup 2+} ions will contribute to the generation of white light while excited at 339 nm using a xenon lamp. Furthermore, the chromaticity color coordinates, correlated color temperature, and quantum efficiency parameters are calculated for all the glass samples, and their relative variations with respect to γ-irradiation dose are presented.

36 MATERIALS SCIENCE↗

Diffusion Quantum Monte Carlo Benchmarking of Magnetic Moments in MnBi 2 Te 4

The intrinsically antiferromagnetic topological insulator, MnBi 2 Te 4 (MBT), has garnered significant attention recently due to its potential to host numerous exotic topological quantum states. Unfortunately, their consistent realization has been hindered by intrinsic antisite defects among the Mn and Bi sublattices. In this work, we establish Mn magnetization of pristine MBT through high level diffusion Monte Carlo calculations, which can serve as a precise starting point for various models to estimate antisite defect concentrations in actual MBT samples. The benchmark quality of DMC calculations is further identified from out model estimating antisite defect concentrations, which combines the benchmarked Mn magnetization with data from magnetic susceptibility and intermediate field magnetization measurements. This reproduces well Bi Mn and Mn Bi concentrations measured in the experiments. Here, we anticipate these theoretically based magnetic purity measures may be used as minimization targets in cycles of refinement to synthesize MBT with low antisite defect concentrations and more reproducible topological properties.

Defects↗

Optimized Sampling Strategies For Non-Proliferation Monitoring: Report

Concentration data collected from the 2013 H-Canyon effluent reprocessing experiment were reanalyzed to improve the source term estimate. When errors in the model-predicted wind speed and direction were removed, the source term uncertainty was reduced to 30% of the mean. This explained the factor of 30 difference between the source term size derived from data at 5 km and 10 km downwind in terms of the time history of dissolution. The results show a path forward to develop a sampling strategy for quantitative source term calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of ADVANTG Simulations to Simple Shielding Measurements - Paper 36

Monte Carlo (MC) radiation transport simulations, like those performed using Monte Carlo N-Particle (MCNP), can be highly accurate but require time to reduce the statistical uncertainties in the calculated detector response(s). Many different 'variance reduction' techniques devised over the years increase the efficiency of MC calculations, but these methods can be more art than science. Many of these methods are problem specific or require careful tuning of parameters for good performance. One of the best variance reduction methods, in terms of both reliable performance increases and ease of use, is the use of weight windows. Weight windows are derived from an importance map in space and energy that allows the transport code to focus more simulation time on particles that have a higher likelihood of being important to the final detector response. Less time is spent simulating particles that have little chance of making a contribution to the detector response. MCNP already includes the abilities to generate and use weight windows. Unfortunately, generating weight windows can take a very long time, perhaps longer than the original problem. Oak Ridge National Laboratory has led the development of hybrid methods using a discrete ordinates adjoint calculation to quickly develop an importance map (weight windows) for use in a Monte Carlo code. The Consistent Adjoint Driven Importance Sampling (CADIS) method uses an adjoint calculation to develop both an importance map and a biased source distribution that work together. This method is reasonably automatic, is easy to use, and has been implemented in the Automated Variance reduction Generator (ADVANTG) package that works with MCNP5. ADVANTG reads an MCNP input file and a small amount of extra user information and then runs an adjoint deterministic calculation using Denovo. The importance map and biased source distribution derived from the CADIS method can then be incorporated back into the original MCNP input file to enhance the figure-of-merit (FOM) of the calculation. The FOM is a measure of the efficiency of the calculation using the amount of run time and corresponding level of statistical uncertainty in the detector result. ADVANTG-enhanced MCNP input files have been shown to increase the FOM of many types of problems, obtaining the same level of statistical uncertainty in a shorter time compared to standard MCNP. ADVANTG can also generate variance reduction parameters (importance map and biased source) using the Forward-Weighted CADIS (FW-CADIS) method for optimizing mesh tallies. The CADIS method creates variance reduction parameters that optimize a tally's total quantity (flux, dose rate, interaction rate, etc.) and will not generally increase performance for all parts of a segmented tally. To optimize a segmented tally, the FW-CADIS method uses two discrete ordinates calculations to make variance reduction parameters that help compute a segmented tally with uniform relative uncertainties in each bin. This report will demonstrate that using ADVANTG for neutron and photon radiation shielding problems will (1) preserve the standard MCNP results and (2) obtain those results either with less statistical uncertainty or in shorter times than the standard MCNP calculation. The four demonstration problems in this report are based on simple neutron or photon transmission measurements through different materials. All of the problems here used the CADIS method and still saw improvement across the flux tallies segmented by particle energy. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Small-angle X-ray microdiffraction from fibrils embedded in tissue thin sections

Small-angle X-ray scattering (SAXS) from fibrils embedded in a fixed, thin section of tissue includes contributions from the fibrils, the polymeric matrix surrounding the fibrils, other constituents of the tissue, and cross-terms due to the spatial correlation between fibrils and neighboring molecules. This complex mixture severely limits the amount of information that can be extracted from scattering studies. However, availability of micro- and nano-beams has made the measurement of scattering from very small volumes possible, which, in some cases, may be dominated by a single fibrillar constituent. In such cases, information about the predominant species may be accessible. Nevertheless, even in these cases, the correlations between the positions of fibrils and other constituents have a significant impact on the observed scattering. Here, strategies are proposed to extract partial information about fibril structure and tissue organization on the basis of SAXS from samples of this type. It is shown that the spatial correlation function of the fibril in the direction perpendicular to the fibril axis can be computed and contains information about the predominant fibril structure and the organization of the surrounding tissue matrix. This has significant advantages over approaches based on techniques developed for X-ray solution scattering. Examples of correlation calculations in different types of samples are given to demonstrate the information that can be obtained from these measurements.

36 MATERIALS SCIENCE↗

Combined measurement of directional Raman scattering and surface-plasmon-polariton cone from adsorbates on smooth planar gold surfaces

Directional-surface-plasmon-coupled Raman scattering (directional RS) has the combined benefits of surface plasmon resonance and Raman spectroscopy, and provides the ability to measure adsorption and monolayer-sensitive chemical information. Directional RS is performed by optically coupling a 50-nm gold film to a Weierstrass prism in the Kretschmann configuration and scanning the angle of the incident laser under total internal reflection. The collected parameters on the prism side of the interface include a full surface-plasmon-polariton cone and the full Raman signal radiating from the cone as a function of incident angle. An instrument for performing directional RS and a quantitative study of the instrumental parameters are herein reported. To test the sensitivity and quantify the instrument parameters, self-assembled monolayers and 10 to 100-nm polymer films are studied. The signals are found to be well-modeled by two calculated angle-dependent parameters: three-dimensional finite-difference time-domain calculations of the electric field generated in the sample layer and projected to the far-field, and Fresnel calculations of the reflected light intensity. This is the first report of the quantitative study of the full surface-plasmon-polariton cone intensity, cone diameter, and directional Raman signal as a function of incident angle. We propose that directional RS is a viable alternative to surface plasmon resonance when added chemical information is beneficial.

47 OTHER INSTRUMENTATION↗

Determination of a brass alloy concentration composition using calibration-free laser-induced breakdown spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is a technique that can provide qualitative and quantitative measurements of the characteristics of irradiated metals. In the present work, we have calculated the parameters of the plasma produced from a brass alloy sample under the action of a pulsed Nd: YAG laser operating at 1064 nm. The emission lines of copper atoms (Cu I), zinc atoms (Zn I), and lead atoms (Pb I), which are elements of a brass alloy composition, were used to investigate the parameters of the brass plasma. The spectral profiles of Cu, Zn, and Pb lines have been used to extract the electron temperature and density of the brass alloy plasma. The characteristics of Cu, Zn, and Pb were determined quantatively by the calibration-free LIBS (CF-LIBS) method considering for accurate analysis that the laser-induced ablated plasma is optically thin in local thermodynamic equilibrium conditions and the plasma ablation is stoichiometric. The Boltzmann plot method was used to evaluate the plasma temperature, and the Stark broadened profiles were used to determine the electron density. An algorithm based on the experimentally measured values of the intensity of spectral lines and the basic laws of plasma physics was developed for the determination of Cu, Zn, and Pb concentrations in the brass sample. The concentrations C{sub CF-LIBS} calculated by CF-LIBS and the certified concentrations C{sub certified} were very close.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sample sizes for confidence limits for reliability.

We recently performed an evaluation of the implications of a reduced stockpile of nuclear weapons for surveillance to support estimates of reliability. We found that one technique developed at Sandia National Laboratories (SNL) under-estimates the required sample size for systems-level testing. For a large population the discrepancy is not important, but for a small population it is important. We found that another technique used by SNL provides the correct required sample size. For systems-level testing of nuclear weapons, samples are selected without replacement, and the hypergeometric probability distribution applies. Both of the SNL techniques focus on samples without defects from sampling without replacement. We generalized the second SNL technique to cases with defects in the sample. We created a computer program in Mathematica to automate the calculation of confidence for reliability. We also evaluated sampling with replacement where the binomial probability distribution applies.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

On evaluating compliance with air pollution levels 'not to be exceeded more than once a year'

Under a sampling program operated in conformity with EPA guidelines, calculational procedures are described for estimating the corresponding ambient pollution level. The statistical independence of the data, the commutativity of expectation and exponential operations, and the statistical variability of the calculated results are quantitatively evaluated. It is shown that the recommended sampling frequencies of every third to every sixth day are inadequate in determining conformity when the standards are expressed as levels not to be exceeded more than once a year.

Neustadter, H. E.↗

Evolution Of Lattice Structure And Chemical Composition Of The Surface Reconstruction Layer In Li1.2Ni0.2Mn0.6O2 Cathode Material For Lithium Ion Batteries

Voltage and capacity fading of layer structured lithium and manganese rich (LMR) transition metal oxide is directly related to the structural and composition evolution of the material during the cycling of the battery. However, understanding such evolution at atomic level remains elusive. Based on atomic level structural imaging, elemental mapping of the pristine and cycled samples and density functional theory calculations, it is found that accompanying the hoping of Li ions is the simultaneous migration of Ni ions towards the surface from the bulk lattice, leading to the gradual depletion of Ni in the bulk lattice and thickening of a Ni enriched surface reconstruction layer (SRL). Furthermore, Ni and Mn also exhibit concentration partitions within the thin layer of SRL in the cycled samples where Ni is almost depleted at the very surface of the SRL, indicating the preferential dissolution of Ni ions in the electrolyte. Accompanying the elemental composition evolution, significant structural evolution is also observed and identified as a sequential phase transition of C2/m →I41→Spinel. For the first time, it is found that the surface facet terminated with pure cation is more stable than that with a mixture of cation and anion. These findings firmly established how the elemental species in the lattice of LMR cathode transfer from the bulk lattice to surface layer and further into the electrolyte, clarifying the long standing confusion and debate on the structure and chemistry of the surface layer and their correlation with the voltage fading and capacity decaying of LMR cathode. Therefore, this work provides critical insights for designing of cathode materials with both high capacity and voltage stability during cycling.

Environmental Molecular Sciences Laboratory↗

Optimal Inequalities to Bound a Performance Probability

A challenging problem encountered in engineering applications is the estimation of a probability-of-failure based on incomplete knowledge of the sources of uncertainty and/or limited sampling. Theories formulated to derive upper probability bounds offer an attractive alternative because first, they avoid postulating the probability laws that are often unknown and second, they substitute numerical optimization for statistical sampling. A critical assessment of one such technique is presented. It derives upper probability bounds from the McDiarmid concentration-of-measure theory, which postulates that fluctuations of a function are more-or-less concentrated about its mean value. Three applications of this theory are presented. The first two applications analyze “toy” polynomial functions defined in two and seventeen dimensions. The upper bounds of probability are calculated and compared to sampling-based estimates of the true-but-unknown probabilities. For these functions, the upper bounds obtained are too broad to be useful. These results are confirmed by conducting a similar analysis on a real engineering system, where upper bounds of probability associated with resonant frequencies of a structural system are estimated. These frequencies are predicted by a high-fidelity finite element model that was previously validated using vibration measurements. In this third application, the uncertainty is introduced by way of material properties and the effective preload of a beam-to-column connection, modeled explicitly. These applications suggest that the theory not only leads to upper bounds that are inefficient but that can also be sub-optimal if their numerical estimation is based on too few model runs. It is concluded that this particular theory, while mathematically attractive, may not be well suited for engineering applications.

Engineering(42)↗

TU-EF-304-07: Monte Carlo-Based Inverse Treatment Plan Optimization for Intensity Modulated Proton Therapy

Purpose: Intensity-modulated proton therapy (IMPT) is increasingly used in proton therapy. For IMPT optimization, Monte Carlo (MC) is desired for spots dose calculations because of its high accuracy, especially in cases with a high level of heterogeneity. It is also preferred in biological optimization problems due to the capability of computing quantities related to biological effects. However, MC simulation is typically too slow to be used for this purpose. Although GPU-based MC engines have become available, the achieved efficiency is still not ideal. The purpose of this work is to develop a new optimization scheme to include GPU-based MC into IMPT. Methods: A conventional approach using MC in IMPT simply calls the MC dose engine repeatedly for each spot dose calculations. However, this is not the optimal approach, because of the unnecessary computations on some spots that turned out to have very small weights after solving the optimization problem. GPU-memory writing conflict occurring at a small beam size also reduces computational efficiency. To solve these problems, we developed a new framework that iteratively performs MC dose calculations and plan optimizations. At each dose calculation step, the particles were sampled from different spots altogether with Metropolis algorithm, such that the particle number is proportional to the latest optimized spot intensity. Simultaneously transporting particles from multiple spots also mitigated the memory writing conflict problem. Results: We have validated the proposed MC-based optimization schemes in one prostate case. The total computation time of our method was ∼5–6 min on one NVIDIA GPU card, including both spot dose calculation and plan optimization, whereas a conventional method naively using the same GPU-based MC engine were ∼3 times slower. Conclusion: A fast GPU-based MC dose calculation method along with a novel optimization workflow is developed. The high efficiency makes it attractive for clinical usages.

60 APPLIED LIFE SCIENCES↗

Correlation function distributions for O ( N ) lattice field theories in the disordered phase

Numerical computations in strongly interacting quantum field theories are often performed using Monte Carlo sampling methods. A key task in these calculations is to estimate the value of a given physical quantity from the distribution of stochastic samples that are generated using the Monte Carlo method. Typically, the sample mean and sample variance are used to define the expectation values and uncertainties of computed quantities. However, the Monte Carlo sample distribution contains more information than these basic properties, and it is useful to investigate it more generally. In this work, the exact form of the probability distributions of two-point correlation functions at zero momentum in O ( N ) lattice field theories in the disordered phase and in infinite volume are determined. These distributions allow for a robust investigation of the efficacy of the Monte Carlo sampling procedure and are shown also to allow for improved estimators of the target physical quantity to be constructed. The theoretical expectations are shown to agree with numerical calculations in the O ( 2 ) model. Published by the American Physical Society 2024

Astronomy & Astrophysics↗