Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Analyte-induced spectral filtering in femtosecond transient absorption spectroscopy

Here, we discuss the influence of spectral filtering by samples in femtosecond transient absorption measurements. Commercial instruments for transient absorption spectroscopy (TA) have become increasingly available to scientists in recent years and TA is becoming an established technique to measure the dynamics of photoexcited systems. Furthermore, we show that absorption of the excitation pulse by the sample can severely alter the spectrum and consequently the temporal pulse shape. This “spectral self-filtering” effect can lead to systematic errors and misinterpretation of data, most notably in concentration dependent measurements. Finally, the combination of narrow absorption peaks in the sample with ultrafast broadband excitation pulses is especially prone to this effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

REPEATABILITY AND ACCURACY OF EXOPLANET ECLIPSE DEPTHS MEASURED WITH POST-CRYOGENIC SPITZER

We examine the repeatability, reliability, and accuracy of differential exoplanet eclipse depth measurements made using the InfraRed Array Camera (IRAC) on the Spitzer Space Telescope during the post-cryogenic mission. We have re-analyzed an existing 4.5 μ m data set, consisting of 10 observations of the XO-3b system during secondary eclipse, using seven different techniques for removing correlated noise. We find that, on average, for a given technique, the eclipse depth estimate is repeatable from epoch to epoch to within 156 parts per million (ppm). Most techniques derive eclipse depths that do not vary by more than a factor 3 of the photon noise limit. All methods but one accurately assess their own errors: for these methods, the individual measurement uncertainties are comparable to the scatter in eclipse depths over the 10 epoch sample. To assess the accuracy of the techniques as well as to clarify the difference between instrumental and other sources of measurement error, we have also analyzed a simulated data set of 10 visits to XO-3b, for which the eclipse depth is known. We find that three of the methods (BLISS mapping, Pixel Level Decorrelation, and Independent Component Analysis) obtain results that are within three times the photon limit of the true eclipse depth. When averaged over the 10 epoch ensemble, 5 out of 7 techniques come within 60 ppm of the true value. Spitzer exoplanet data, if obtained following current best practices and reduced using methods such as those described here, can measure repeatable and accurate single eclipse depths, with close to photon-limited results.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-Photon Laser-Induced Fluorescence O and N Atoms for the Study of Heterogeneous Catalysis in a Diffusion Reactor

Advanced laser-based diagnostics have been developed to examine catalytic effects and atom/surface interactions on thermal protection materials. This study establishes the feasibility of using laser-induced fluorescence for detection of O and N atom loss in a diffusion tube to measure surface catalytic activity. The experimental apparatus is versatile in that it allows fluorescence detection to be used for measuring species selective recombination coefficients as well as diffusion tube and microwave discharge diagnostics. Many of the potential sources of error in measuring atom recombination coefficients by this method have been identified and taken into account. These include scattered light, detector saturation, sample surface cleanliness, reactor design, gas pressure and composition, and selectivity of the laser probe. Recombination coefficients and their associated errors are reported for N and O atoms on a quartz surface at room temperature.

Pallix, Joan B.↗

Detection of the pairwise kinematic Sunyaev-Zel'dovich effect with BOSS DR11 and the Atacama Cosmology Telescope

Here, we present a new measurement of the kinematic Sunyaev-Zel'dovich effect using data from the Atacama Cosmology Telescope (ACT) and the Baryon Oscillation Spectroscopic Survey (BOSS). Using 600 square degrees of overlapping sky area, we evaluate the mean pairwise baryon momentum associated with the positions of 50,000 bright galaxies in the BOSS DR11 Large Scale Structure catalog. A non-zero signal arises from the large-scale motions of halos containing the sample galaxies. The data fits an analytical signal model well, with the optical depth to microwave photon scattering as a free parameter determining the overall signal amplitude. We estimate the covariance matrix of the mean pairwise momentum as a function of galaxy separation, using microwave sky simulations, jackknife evaluation, and bootstrap estimates. The most conservative simulation-based errors give signal-to-noise estimates between 3.6 and 4.1 for varying galaxy luminosity cuts. We discuss how the other error determinations can lead to higher signal-to-noise values, and consider the impact of several possible systematic errors. Estimates of the optical depth from the average thermal Sunyaev-Zel'dovich signal at the sample galaxy positions are broadly consistent with those obtained from the mean pairwise momentum signal.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK XIII. Intensity foreground sampling, degeneracies, and priors

We present the intensity foreground algorithms and model employed within the BEYONDPLANCK analysis framework. The BEYONDPLANCK analysis is aimed at integrating component separation and instrumental parameter sampling within a global framework, leading to complete end-to-end error propagation in the Planck Low Frequency Instrument (LFI) data analysis. Given the scope of the BEYONDPLANCK analysis, a limited set of data is included in the component separation process, leading to foreground parameter degeneracies. In order to properly constrain the Galactic foreground parameters, we improve upon the previous Commander component separation implementation by adding a suite of algorithmic techniques. These algorithms are designed to improve the stability and computational efficiency for weakly constrained posterior distributions. These are: (1) joint foreground spectral parameter and amplitude sampling, building on ideas from MIRAMARE; (2) component-based monopole determination; (3) joint spectral parameter and monopole sampling; and (4) application of informative spatial priors for component amplitude maps. We find that the only spectral parameter with a significant signal-to-noise ratio using the current BEYONDPLANCK data set is the peak frequency of the anomalous microwave emission component, for which we find $ν$ p = 25.3 ± 0.5 GHz; all others must be constrained through external priors. Future works will be aimed at integrating many more data sets into this analysis, both map and time-ordered based, thereby gradually eliminating the currently observed degeneracies in a controlled manner with respect to both instrumental systematic effects and astrophysical degeneracies. When this happens, the simple LFI-oriented data model employed in the current work will need to be generalized to account for both a richer astrophysical model and additional instrumental effects. This work will be organized within the Open Science-based COSMOGLOBE community effort.

79 ASTRONOMY AND ASTROPHYSICS↗

Eddy-current measurements of thickness of high-temperature coatings

The eddy-current technique was applied to measuring the thickness of a fused silicide coating on a refractory alloy slab. Phase and magnitude of the test signal were measured at four places in 13 different samples, and thickness of coating was computed on the basis of each of these quantities. These results were then compared with those obtained by conventional metallographic methods. Phase-based measurements were most reliable, and the maximum error between the metallographically determined thickness and the thickness as determined by the least squares fit to the phase measurements was less than 0.01 mm (about 1%). Photomicrography of a typical sample shows that a large source of error resides in the fact that two regions - an outer rough region and an inner uniform region - of the coating layer exist rather than the single region upon which the calculations were based.

Dodd, C. V.↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

CODEX weak lensing: concentration of galaxy clusters at z ~ 0.5

Here, we present a stacked weak-lensing analysis of 27 richness selected galaxy clusters at 0.40 ≤ z ≤ 0.62 in the COnstrain Dark Energy with X-ray galaxy clusters (CODEX) survey. The fields were observed in five bands with the Canada–France–Hawaii Telescope (CFHT). We measure the stacked surface mass density profile with a 14σ significance in the radial range 0.1 < RMpch -1 < 2.5. The profile is well described by the halo model, with the main halo term following a Navarro–Frenk–White profile (NFW) profile and including the off-centring effect. We select the background sample using a conservative colour–magnitude method to reduce the potential systematic errors and contamination by cluster member galaxies. We perform a Bayesian analysis for the stacked profile and constrain the best-fitting NFW parameters M 200c =6.6$+1.0\atop{-0.8}$×10 14 h -1 M⊙ and c 200c =3.7$+0.7\atop{-0.6}$. The off-centring effect was modelled based on previous observational results found for redMaPPer Sloan Digital Sky Survey clusters. Our constraints on M200c and c200c allow us to investigate the consistency with numerical predictions and select a concentration–mass relation to describe the high richness CODEX sample. Comparing our best-fitting values for M200c and c200c with other observational surveys at different redshifts, we find no evidence for evolution in the concentration–mass relation, though it could be mitigated by particular selection functions. Similar to previous studies investigating the X-ray luminosity–mass relation, our data suggest a lower evolution than expected from self-similarity.

79 ASTRONOMY AND ASTROPHYSICS↗

Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.

Hazen-Bosveld, April↗

PARALLAX RESULTS FROM URAT EPOCH DATA

We present 1103 trigonometric parallaxes and proper motions from the United States Naval Observatory Robotic Astrometric Telescope (URAT) observations taken at the Naval Observatory Flagstaff Station (NOFS) over a three-year period from 2012 April to 2015 June covering the entire sky north of about −10{sup ∘} decl. We selected two samples: previously suspected nearby stars from known photometric distances and stars showing a large, significant parallax signature in URAT epoch data without any prior selection criteria. All systems presented in this paper have an observed parallax ≥40 mas with no previous published trigonometric parallax. The formal errors on these weighted parallax solutions are mostly between 4 and 10 mas. This sample gives a significant (of the order of 50%) increase to the number of known systems having a trigonometric parallax to be within 25 pc of the Sun (without applying Lutz–Kelker bias corrections). A few of these are found to be within 10 pc. Many of these new nearby stars display a total proper motion of less than 200 mas yr{sup −1}. URAT parallax results have been verified against Hipparcos and Yale data for stars in common. The publication of all signifigant parallax observations from URAT data is in preparation for CDS.

79 ASTRONOMY AND ASTROPHYSICS↗

Partial Least Squares, Experimental Design, and Near-Infrared Spectrophotometry for the Remote Quantification of Nitric Acid Concentration and Temperature

Near-infrared spectrophotometry and partial least squares regression (PLSR) were evaluated to create a pleasantly simple yet effective approach for measuring HNO3 concentration with varying temperature levels. A training set, which covered HNO3 concentrations (0.1–8 M) and temperature (10–40 °C), was selected using a D-optimal design to minimize the number of samples required in the calibration set for PLSR analysis. The top D-optimal-selected PLSR models had root mean squared error of prediction values of 1.4% for HNO 3 and 4.0% for temperature. The PLSR models built from spectra collected on static samples were validated against flow tests including HNO 3 concentration and temperature gradients to test abnormal conditions (e.g., bubbles) and the model performance between sample points in the factor space. Based on cross-validation and prediction modeling statistics, the designed near-infrared absorption approach can provide remote, quantitative analysis of HNO 3 concentration and temperature for production-oriented applications in facilities where laser safety challenges would inhibit the implementation of other optical techniques (e.g., Raman spectroscopy) and in which space, time, and/or resources are constrained. The experimental design approach effectively minimized the number of samples in the training set and maintained or improved PLSR model performance, which makes the described chemometric approach more amenable to nuclear field applications.

07 ISOTOPE AND RADIATION SOURCES↗

Learning to concentrate: multi-tracer forecasts on local primordial non-Gaussianity with machine-learned bias

Local primordial non-Gaussianity (LPNG) is predicted by many non-minimal models of inflation, and creates a scale-dependent contribution to the power spectrum of large-scale structure (LSS) tracers, whose amplitude is characterized by b Φ . Knowledge of b Φ for the observed tracer population is therefore crucial for learning about inflation from LSS. Recently, it has been shown that the relationship between linear bias b 1 and b Φ for simulated halos exhibits significant secondary dependence on halo concentration. We leverage this fact to forecast multi-tracer constraints on ${f}^{loc}_{NL}$. We train a machine learning model on observable properties of simulated IllustrisTNG galaxies to predict b Φ for samples constructed to approximate DESI emission line galaxies (ELGs) and luminous red galaxies (LRGs). We find σ(${f}^{loc}_{NL}$) = 2.3, and σ(${f}^{loc}_{NL}$) = 3.7, respectively. These forecasted errors are roughly factors of 3, and 35% improvements over the single-tracer case for each sample, respectively. When considering both ELGs and LRGs in their overlap region, we forecast σ(${f}^{loc}_{NL}$) = 1.5 is attainable with our learned model, more than a factor of 3 improvement over the single-tracer case, while the ideal split by b Φ could reach σ(${f}^{loc}_{NL}$) < 1. In conclusion, we also perform multi-tracer forecasts for upcoming spectroscopic surveys targeting LPNG (MegaMapper, SPHEREx) and show that splitting tracer samples by b Φ can lead to an order-of-magnitude reduction in projected σ(${f}^{loc}_{NL}$) for these surveys.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Abundance matching analysis of the emission-line galaxy sample in the extended Baryon Oscillation Spectroscopic Survey

We present the measurements of the small-scale clustering for the emission-line galaxy (ELG) sample from the extended Baryon Oscillation Spectroscopic Survey (eBOSS) in the Sloan Digital Sky Survey IV (SDSS-IV). We use conditional abundance matching method to interpret the clustering measurements from 0.34 to 70 h -1 Mpc. In order to account for the correlation between properties of ELGs and their environment, we add a secondary connection between star formation rate of ELGs and halo accretion rate. Three parameters are introduced to model the ELG [O II ] luminosity and to mimic the target selection of eBOSS ELGs. The parameters in our models are optimized using Markov Chain Monte Carlo (MCMC) method. We find that by conditionally matching star formation rate of galaxies and the halo accretion rate, we are able to reproduce the eBOSS ELG small-scale clustering within 1σ error level. Our best-fitting model shows that the eBOSS ELG sample only consists of ~ 12 per cent of all star-forming galaxies, and the satellite fraction of eBOSS ELG sample is 19.3 per cent. We show that the effect of assembly bias is ~ 20 per cent on the two-point correlation function and ~ 5 per cent on the void probability function at scale of r ~ 20 h -1 Mpc.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗

A Computational Information Criterion for Particle-Tracking with Sparse or Noisy Data

Traditional probabilistic methods for the simulation of advection-diffusion equations (ADEs) often overlook the entropic contribution of the discretization, e.g., the number of particles, within associated numerical methods. Many times, the gain in accuracy of a highly discretized numerical model is outweighed by its associated computational costs or the noise within the data. Herein, we address the question of how many particles are needed in a simulation to best approximate and estimate parameters in one-dimensional advective-diffusive transport. To do so, we use the well-known Akaike Information Criterion (AIC) and a recently-developed correction called the Computational Information Criterion (COMIC) to guide the model selection process. Random-walk and mass-transfer particle tracking methods are employed to solve the model equations at various levels of discretization. Numerical results demonstrate that the COMIC provides an optimal number of particles that can describe a more efficient model in terms of parameter estimation and model prediction compared to the model selected by the AIC even when the data is sparse or noisy, the sampling volume is not uniform throughout the physical domain, or the error distribution of the data is non-IID Gaussian.

97 MATHEMATICS AND COMPUTING↗

Non-destructive investigation of thermoplastic reinforced composites

This paper studies various manufacturing defects in glass fiber/Polypropylene (PP) composite parts and their methods of detection. Foreign Object Inclusion (FOI) of different shapes, sizes, and materials were placed in a glass fiber/PP panel made by compression molding. The paper aims to characterize the fiber orientation and fiber related defects such as fiber waviness in the composite specimen. Comprehensive investigation for different Non Destructive Evaluation (NDE) techniques, namely X-ray radiography and Ultrasonic Testing (UT) techniques to trace and characterize the embedded defects and the composite texture are presented. Conventional X-ray radiography successfully identified the fiber orientation in two dimension (2-D) plane; however, information for the sample depth was not captured. The radiography techniques showed low relative errors for the defect size measurements (maximum error was below 9.5%) when compared to the ultrasonic techniques. Ultrasonic techniques were able to map all the embedded artificial defects. Phase Array (PA) ultrasonic technique was able to precisely locate the FOI in the glass fiber/PP specimen. Nerveless, the shape and size of the defects were not accurately determined due to the high signal attenuation and distortion characteristics of the E-glass fiber.

36 MATERIALS SCIENCE↗

Fast-neutron multiplicity counter for active measurements of uranium oxide certified material

We developed a fast-neutron multiplicity counter (FNMC) based on stilbene and EJ-309 organic 11 scintillators. The system can detect and discriminate correlated photon and neutron multiplets emitted by fission 12 reactions. We used the system to estimate the fissile mass of uranium oxide samples in active interrogation mode at the 13 Zero Power Physics Reactor of Idaho National Laboratory (INL). Two sets of certified reference material (CRM) 14 samples were characterized. The U-235 enrichment of the first set is constant at 93.2 wt%, and the UO 2 mass ranges 15 between 0.5 and 4 kg. The second set includes samples of increasing enrichment (from 20 wt% to 97 wt%) and constant 16 UO 2 mass of 230 g. We used two AmLi sources to induce fission reactions in the samples. Despite the intense gamma17 ray background of the UO 2 and interrogating sources, the system could measure induced fission neutrons emerging from 18 the interrogated samples without additional shielding surrounding the sample and only relying on pulse shape 19 discrimination to classify neutron and gamma-ray pulses. Here, the overall neutron count rate and time-correlated counts are 20 well correlated with the sample fissile mass. We also proved that CRM samples can be used to build a calibration curve 21 to assay the U-235 mass of unknown samples of different mass, geometry and enrichment, with an average bias error of 22 8%, for U-235 mass higher than 390 g.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Ensemble Diagnostic Evaluation of Hydrologic Parameter Uncertainty in the Community Land Model Version 5 (CLM5)

Abstract Land surface models such as the Community Land Model version 5 (CLM5) seek to enhance understanding of terrestrial hydrology and aid in the evaluation of anthropogenic and climate change impacts. However, the effects of parametric uncertainty on CLM5 hydrologic predictions across regions, timescales, and flow regimes have yet to be explored in detail. The common use of the default hydrologic model parameters in CLM5 risks generating streamflow predictions that may lead to incorrect inferences for important dynamics and/or extremes. In this study, we benchmark CLM5 streamflow predictions relative to the commonly employed default hydrologic parameters for 464 headwater basins over the conterminous United States (CONUS). We evaluate baseline CLM5 default parameter performance relative to a large (1,307) Latin Hypercube Sampling‐based diagnostic comparison of streamflow prediction skill using over 20 error measures. We provide a global sensitivity analysis that clarifies the significant spatial variations in parametric controls for CLM5 streamflow predictions across regions, temporal scales, and error metrics of interest. The baseline CLM5 shows relatively moderate to poor streamflow prediction skill in several CONUS regions, especially the arid Southwest and Central U.S. Hydrologic parameter uncertainty strongly affects CLM5 streamflow predictions, but its impacts vary in complex ways across U.S. regions, timescales, and flow regimes. Overall, CLM5's surface runoff and soil water parameters have the largest effects on simulated high flows, while canopy water and evaporation parameters have the most significant effects on the water balance.

54 ENVIRONMENTAL SCIENCES↗