Search NASA⌕ Search

SEARCH · Search NASA

Results for “Soft computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

911 records · Page 51

Effect of macroscopic surface defects on dynamic damage: An experimental and numerical study

This study examines the impact of macroscopic surface defects on the dynamic ductile damage behavior of polycrystalline metals using plate-impact experiments. Defects of various shapes (flat, round, and point) were manufactured on the free or impact surfaces of annealed copper specimens. The experiments were diagnosed with photon Doppler velocimetry measurements and soft recovery techniques. The experimental results revealed that defect shape and location significantly affect velocity–time profiles and void distribution. In order to understand the dynamics of shock propagation and corresponding ductile damage evolution within the target specimens, the impact experiments were modeled with a calibrated Tepla model, a dynamic ductile damage model for polycrystalline metals [Nguyen et al., Int. J. Solids Struct. 329, 113833 (2026)]. Overall, our resulting simulated velocity showed good agreement with measured velocity, and our simulated porosity distributions qualitatively matched experimental data. Based on our simulation results, defects on the free surface were found to distort rarefaction waves and therefore the corresponding spall planes. On the other hand, defects on the impact surface generated a delayed shock when the flyer plate and the defected target area were in contact, leading to distortion of the spall plane. The distortion of the spall plane resulted in a non-uniform distribution of voids within the defected specimens. Lastly, we examined the role of local work hardening due to the defect manufacturing process on the velocity and porosity distribution, using Tepla simulations with a simplified representation of local hardening. This investigation highlights the importance of defect geometry, location, and local hardening associated with defect generation in dynamic ductile damage processes.

36 MATERIALS SCIENCE↗

SU-E-J-90: MRI-Based Treatment Simulation and Patient Setup for Radiation Therapy of Brain Cancer

Purpose: Traditional radiation therapy of cancer is heavily dependent on CT. CT provides excellent depiction of the bones but lacks good soft tissue contrast, which makes contouring difficult. Often, MRIs are fused with CT to take advantage of its superior soft tissue contrast. Such an approach has drawbacks. It is desirable to perform treatment simulation entirely based on MRI. To achieve MR-based simulation for radiation therapy, bone imaging is an important challenge because of the low MR signal intensity from bone due to its ultra-short T2 and T1, which presents difficulty for both dose calculation and patient setup in terms of digitally reconstructed radiograph (DRR) generation. Current solutions will either require manual bone contouring or multiple MR scans. We present a technique to generate DRR using MRI with an Ultra Short Echo Time (UTE) sequence which is applicable to both OBI and ExacTrac 2D patient setup. Methods: Seven brain cancer patients were scanned at 1.5 Tesla using a radial UTE sequence. The sequence acquires two images at two different echo times. The two images were processed using in-house software. The resultant bone images were subsequently loaded into commercial systems to generate DRRs. Simulation and patient clinical on-board images were used to evaluate 2D patient setup with MRI-DRRs. Results: The majority bones are well visualized in all patients. The fused image of patient CT with the MR bone image demonstrates the accuracy of automatic bone identification using our technique. The generated DRR is of good quality. Accuracy of 2D patient setup by using MRI-DRR is comparable to CT-based 2D patient setup. Conclusion: This study shows the potential of DRR generation with single MR sequence. Further work will be needed on MR sequence development and post-processing procedure to achieve robust MR bone imaging for other human sites in addition to brain.

60 APPLIED LIFE SCIENCES↗

SU-E-J-166: Sensitivity of Clinically Relevant Dosimetric Parameters to Contouring Uncertainty During Post Implant Dosimetry of Prostate Permanent Seed Implants

Purpose: There is a strong evidence relating post-implant dosimetry for permanent seed prostate brachytherpy to local control rates. The delineation of the prostate on CT images, however, represents a challenge as it is difficult to confidently identify the prostate borders from soft tissue surrounding it. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to prostate contouring uncertainty. Methods: The post-implant CT images and plans for a cohort of 43 patients, who have received I–125 permanent prostate seed implant in our centre, were exported to MIM Symphony LDR brachytherapy treatment planning system (MIM Software Inc., Cleveland, OH). The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00mm, ±2.00mm, ±3.00mm, ±4.00mm and ±5.00mm (±0.01mm). The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: The mean value of V100 and D90 was obtained as 92.3±8.4% and 108.4±12.3% respectively (Rx=145Gy). V100 was reduced by −3.2±1.5%, −7.2±3.0%, −12.8±4.0%, −19.0±4.8%, − 25.5±5.4% for expanded contours of prostate with margins of +1mm, +2mm, +3mm, +4mm, and +5mm, respectively, while it was increased by 1.6±1.2%, 2.4±2.4%, 2.7±3.2%, 2.9±4.2%, 2.9±5.1% for the contracted contours. D90 was reduced by −6.9±3.5%, −14.5±6.1%, −23.8±7.1%, − 33.6±8.5%, −40.6±8.7% and increased by 4.1±2.6%, 6.1±5.0%, 7.2±5.7%, 8.1±7.3% and 8.1±7.3% for the same set of contours. Conclusion: Systematic expansion errors of more than 1mm may likely render a plan sub-optimal. Conversely contraction errors may Result in labeling a plan likely as optimal. The use of MRI images to contour the prostate should results in better delineation of prostate organ which increases the predictive value of post-op plans. Since observers tend to overestimate the prostate volume on CT, compared with MRI, the impact of the contouring uncertainty on V100 and D90 fortunately, has a conservative effect of underestimating the prostate coverage.

60 APPLIED LIFE SCIENCES↗

Preoperative Pazopanib in High-Risk Soft Tissue Sarcoma: Phase II Window-of Opportunity Study of the German Interdisciplinary Sarcoma Group (NOPASS/GISG-04)

Background: Preoperative devascularization might improve local control and thus the outcome of patients with soft tissue sarcoma (STS). The multikinase inhibitor pazopanib has antiangiogenic effects and is approved for treating metastatic STS. We conducted a trial of preoperative pazopanib therapy in high-risk STS. Methods: This single-arm, phase II trial included patients with resectable, non-metastatic, treatment-naïve, high-risk STS. Patients received pazopanib 800 mg daily while waiting for surgery (21-day ‘window of opportunity’). The primary endpoint was metabolic response rate (MRR; proportion of patients with ≥ 50% reduction of mean standardized uptake value [SUV{sub mean}] in post- vs. pretreatment fluorodeoxyglucose–positron emission tomography/computed tomography [FDG-PET-CT]). Planned sample size was 35 patients (type I error, 5%; type II error, 20%). A translational substudy explored associations between response and concentration of circulating angiogenic factors. Results: Futility analysis was performed after 21 patients (11 female, mean age 67 years; liposarcoma n = 15); 17/21 patients were evaluable for the primary endpoint. The MRR was 1/17 (5.9%, 95% confidence interval < 0.01–0.29). Mean change in SUV{sub mean} of post- versus pretreatment PET was a 6% decrease (range 65% decrease to 34% increase); 7/21 (33.3%) patients had 12 grade 3/4 toxicities, and 19/21 (95.2%) patients were resected (all R0). One (4.8%) patient suffered a grade 4 postoperative complication (anastomotic leakage). Circulating endothelial progenitor cells, soluble vascular endothelial growth factor, and angiopoietin-2 concentrations showed no relevant changes during treatment. Conclusions: Although this study showed that preoperative pazopanib is not effective for unselected high-risk STS patients, relevant treatment effects were observed in a single patient. Future research needs to better define subgroups potentially benefiting from preoperative pazopanib treatment. ClinicalTrials.gov identifier: NCT01543802.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-06: Kernel Based Dosimetry for 90Y Microsphere Liver Therapy Using 90Y Bremsstrahlung SPECT/CT

Purpose: 90Y microsphere therapy in liver presents a situation where beta transport is dominant and the tissue is relatively homogenous. We compare voxel-based absorbed doses from a 90Y kernel to Monte Carlo (MC) using quantitative 90Y bremsstrahlung SPECT/CT as source distribution. Methods: Liver, normal liver, and tumors were delineated by an interventional radiologist using contrast-enhanced CT registered with 90Y SPECT/CT scans for 14 therapies. Right lung was segmented via region growing. The kernel was generated with 1.04 g/cc soft tissue for 4.8 mm voxel matching the SPECT. MC simulation materials included air, lung, soft tissue, and bone with varying densities. We report percent difference between kernel and MC (%Δ(K,MC)) for mean absorbed dose, D70, and V20Gy in total liver, normal liver, tumors, and right lung. We also report %Δ(K,MC) for heterogeneity metrics: coefficient of variation (COV) and D10/D90. The impact of spatial resolution (0, 10, 20 mm FWHM) and lung shunt fraction (LSF) (1,5,10,20%) on the accuracy of MC and kernel doses near the liver-lung interface was modeled in 1D. We report the distance from the interface where errors become <10% of unblurred MC as d10(side of interface, dose calculation, FWHM blurring, LSF). Results: The %Δ(K,MC) for mean, D70, and V20Gy in tumor and liver was <7% while right lung differences varied from 60–90%. The %Δ(K,MC) for COV was <4.8% for tumor and liver and <54% for the right lung. The %Δ(K,MC) for D10/D90 was <5% for 22/23 tumors. d10(liver,MC,10,1–20) awere <9mm and d10(liver,MC,20,1–20) awere <15mm; both agreed within 3mm to the kernel. d10(lung,MC,10,20), d10(lung,MC,10,1), d10(lung,MC,20,20), and d10(lung,MC,20,1) awere 6, 25, 15, and 34mm, respectively. Kernel calculations on blurred distributions in lung had errors > 10%. Conclusions: Liver and tumor voxel doses with 90Y kernel and MC agree within 7%. Large differences exist between the two methods in right lung. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

WE-A-17A-07: Evaluation of a Grid-Based Boltzmann Solver for Nuclear Medicine Voxel-Based Dose Calculations

Purpose: Grid-based Boltzmann solvers (GBBS) have been successfully implemented in radiation oncology clinics as dose calculations for e×ternal photon beams and 192Ir sealed-source brachytherapy. We report on the evaluation of a GBBS for nuclear medicine vo×el-based absorbed doses. Methods: Vo×el-S-values were calculated for monoenergetic betas and photons (1, 0.1, 0.01 MeV), 90Y, and 131I for 3 mm vo×el sizes using Monte Carlo (DOS×YZnrc) and GBBS (Attila 8.1-beta5, Transpire). The source distribution was uniform throughout a single vo×el. The material was an infinite 1.04 g/cc soft tissue slab. To e×plore convergence properties of the GBBS 3 tetrahedral meshes, 3 energy group structures, 3 different square Chebyschev-Legendre quadrature set orders (Sn), and 4×2013;7 spherical harmonic e×pansion terms (Pn) were investigated for a total of 168 discretizations per source. The mesh, energy group, and quadrature sets are 8×, 3×, and 16×, respectively, finer than the corresponding coarse discretization. GBBS cross sections were generated with full electronphoton-coupling using the vendors e×tended CEP×S code. For accuracy, percent differences (%Δ) in source vo×el absorbed doses between MC and GBBS are reported for the coarsest and finest discretization. For convergence, ratios of the two finest discretization solutions are reported along each variable. Results: For 1 MeV, 0.1 MeV, 0.01 MeV, Y90, and I-131 beta sources the %Δ in the source vo×el for (coarsest,finest) discretization were (+2.0,−6.4), (−8.0, −7.5), (−13.8, −13.4), (+0.9,−5.5), and (− 10.1,−9.0) respectively. The corresponding %Δ for photons were (+33.7,−7.1), (−9.4, −9.8), (−17.4, −15.2), and (−1.7,−7.7), respectively. For betas, the convergence ratio of mesh, energy, Sn, and Pn ranged from 0.991–1.000. For gammas, the convergence ratio of mesh, Sn, and Pn ranged from 0.998–1.003 while the ratio for energy ranged from 0.964–1.001. Conclusions: GBBS is promising for nuclear medicine vo×el-based dose calculations. Ongoing work includes evaluating GBBS in bone, lung, and realistic clinical PET/SPECT-based activity distributions. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA138986. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institutes of Health.

07 ISOTOPE AND RADIATION SOURCES↗

MO-G-BRF-02: Enhancement of Texture-Based Metastasis Prediction Models Via the Optimization of PET/MRI Acquisition Protocols

Purpose: We have previously identified a prediction model of lung metastases at diagnosis of soft-tissue sarcomas (STS) that is composed of two textural features extracted from FDG-PET and T1-weighted (T1w) MRI scans. The goal of this study is to evaluate whether the optimization in FDGPET and MRI acquisition parameters would enhance the prediction performance of texture-based models. Methods: Ten FDG-PET and T1w- MRI digitized tumor models were generated from imaging data of STS patients who underwent pre-treatment clinical scans between 2005 and 2011. Five of ten patients eventually developed lung metastases. Numerically simulated MR images were produced using echo times (TE) of 2 and 4 times the nominal clinical parameter (TEc), and repetition times (TR) of 0.5, 0.67, 1.5 and 2 times the nominal clinical parameter (TRc) found in the DICOM headers (TEc range: 9–13 ms, TRc range: 410-667 ms). PET 2D images were simulated using Monte-Carlo and were reconstructed using an ordered-subsets expectation maximization (OSEM) algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. For all possible combinations of PET and MRI acquisition parameters, the prediction model was constructed using logistic regression with new coefficients, and its associated prediction performance for lung metastases was evaluated using the area under the ROC curve (AUC). Results: The prediction performance over all simulations yielded AUCs ranging from 0.7 to 1. Notably, TR values below or equal to TRc and higher PET post-reconstruction filter widths yielded higher prediction performance. The best results were obtained with a combination of 4*TEc, TRc, 30 OSEM iterations and 2mm filter width. Conclusion: This work indicates that texture-based metastasis prediction models could be improved using optimized choices of FDG-PET and MRI acquisition protocols. This principle could be generalized to other texture-based models.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗

Metabolic alterations in bladder cancer: applications for cancer imaging

Treatment planning, outcome and prognosis are strongly related to the adequate tumor staging for bladder cancer (BC). Unfortunately, a large discrepancy exists between the preoperative clinical and final pathologic staging. Therefore, an advanced imaging-based technique is crucial for adequate staging. Although Magnetic Resonance Imaging (MRI) is currently the best in vivo imaging technique for BC staging because of its excellent soft-tissue contrast and absence of ionizing radiation it lacks cancer-specificity. Tumor-specific positron emission tomography (PET), which is based on the Warburg effect (preferential uptake of glucose by cancer cells), exploits the radioactively–labeled glucose analogs, i.e., FDG. Although FDG-PET is highly cancer specific, it lacks resolution and contrast quality comparable with MRI. Chemical Exchange Saturation Transfer (CEST) MRI enables the detection of low concentrations of metabolites containing protons. BC is an attractive target for glucose CEST MRI because, in addition to the typical systemic administration, glucose might also be directly applied into the bladder to reduce toxicity-related complications. As a first stage of the development of a contrast-specific BC imaging technique we have studied glucose uptake by bladder epithelial cells and have observed that glucose is, indeed, consumed by BC cells with higher intensity than by non-transformed urothelial cells. This effect might be partly explained by increased expression of glucose transporters GLUT1 and GLUT3 in transformed cells as compared to normal urothelium. We also detected higher lactate production by BC cells which is another cancer-specific manifestation of the Warburg effect. In addition, we have observed other metabolic alterations in BC cells as compared to non-transformed cells: in particular, increased pyruvate synthesis. When glucose was substituted by glutamine in culture media, preferential uptake of glutamine by BC cells was observed. The preferential uptake of glucose by BC cells gives an opportunity to develop NMR based imaging procedures where glucose or its derivatives can serve as a contrasting agent. In addition, metabolic alterations observed in BC cells could provide the basis for development of new anti-cancer therapeutics.

60 APPLIED LIFE SCIENCES↗

A multiscale anisotropic polymer network model coupled with phase field fracture

The study of polymers has continued to gain substantial attention due to their expanding range of applications, spanning essential engineering fields to emerging domains like stretchable electronics, soft robotics, and implantable sensors. These materials exhibit remarkable properties, primarily stemming from their intricate polymer chain network, which, in turn, increases the complexity of precisely modeling their behavior. Especially for modeling elastomers and their fracture behavior, accurately accounting for the deformations of the polymer chains is vital for predicting the rupture in highly stretched chains. Despite the importance, many robust multiscale continuum frameworks for modeling elastomer fracture tend to simplify network deformations by assuming uniform behavior among chains in all directions. Recognizing this limitation, our study proposes a multiscale fracture model that accounts for the anisotropic nature of elastomer network responses. At the microscale, damage in the chains is assumed to be driven by both the chain's entropy and the internal energy due to molecular bond distortions. In order to bridge the stretching in the chains to the macroscale deformation, we employ the maximal advance path constraint network model, inherently accommodating anisotropic network responses. As a result, chains oriented differently can be predicted to exhibit varying stretch and, consequently, different damage levels. To drive macroscale fracture based on damages in these chains, we utilize the micromorphic regularization theory, which involves the introduction of dual local-global damage variables at the macroscale. The macroscale local damage variable is obtained through the homogenization of the chain damage values, resulting in the prediction of an isotropic material response. The macroscale global damage variable is subjected to nonlocal effects and boundary conditions in a thermodynamically consistent phase field continuum formulation. Moreover, the total dissipation in the system is considered to be mainly due to the breaking of the molecular bonds at the microscale. To validate our model, we employ the double-edge notched tensile test as a benchmark, comparing simulation predictions with existing experimental data. Additionally, to enhance our understanding of the fracturing process, we conduct uniaxial tensile experiments on a square film made up of polydimethylsiloxane (PDMS) rubber embedded with a hole and notches and then compare our simulation predictions with the experimental observations. Furthermore, we visualize the evolution of stretch and damage values in chains oriented along different directions to assess the predictive capacity of the model. In conclusion, the results are also compared with another existing model to evaluate the utility of our model in accurately simulating the fracture behavior of rubber-like materials.

42 ENGINEERING↗

Light-Front Holographic QCD

The relation between the hadronic short-distance constituent quark and gluon particle limit and the long-range confining domain is yet one of the most challenging aspects of particle physics due to the strong coupling nature of Quantum Chromodynamics, the fundamental theory of the strong interactions. The central question is how one can compute hadronic properties from first principles; i.e., directly from the QCD Lagrangian. The most successful theoretical approach thus far has been to quantize QCD on discrete lattices in Euclidean space-time. Lattice numerical results follow from computation of frame-dependent moments of distributions in Euclidean space and dynamical observables in Minkowski spacetime, such as the time-like hadronic form factors, are not amenable to Euclidean lattice computations. The Dyson-Schwinger methods have led to many important insights, such as the infrared fixed point behavior of the strong coupling constant, but in practice, the analyses are limited to ladder approximation in Landau gauge. Baryon spectroscopy and the excitation dynamics of nucleon resonances encoded in the nucleon transition form factors can provide fundamental insight into the strong-coupling dynamics of QCD. New theoretical tools are thus of primary interest for the interpretation of the results expected at the new mass scale and kinematic regions accessible to the JLab 12 GeV Upgrade Project. The AdS/CFT correspondence between gravity or string theory on a higher-dimensional anti-de Sitter (AdS) space and conformal field theories in physical space-time has led to a semiclassical approximation for strongly-coupled QCD, which provides physical insights into its nonperturbative dynamics. The correspondence is holographic in the sense that it determines a duality between theories in different number of space-time dimensions. This geometric approach leads in fact to a simple analytical and phenomenologically compelling nonperturbative approximation to the full light-front QCD Hamiltonian 'Light-Front Holography'. Light-Front Holography is in fact one of the most remarkable features of the AdS/CFT correspondence. The Hamiltonian equation of motion in the light-front (LF) is frame independent and has a structure similar to eigenmode equations in AdS space. This makes a direct connection of QCD with AdS/CFT methods possible. Remarkably, the AdS equations correspond to the kinetic energy terms of the partons inside a hadron, whereas the interaction terms build confinement and correspond to the truncation of AdS space in an effective dual gravity approximation. One can also study the gauge/gravity duality starting from the bound-state structure of hadrons in QCD quantized in the light-front. The LF Lorentz-invariant Hamiltonian equation for the relativistic bound-state system is P{sub {mu}}P{sup {mu}}|{psi}(P)> = (P{sup +}P{sup -} - P{sub {perpendicular}}{sup 2})|{psi}(P)> = M{sup 2}|{psi}(P)>, P{sup {+-}} = P{sup 0} {+-} P{sup 3}, where the LF time evolution operator P{sup -} is determined canonically from the QCD Lagrangian. To a first semiclassical approximation, where quantum loops and quark masses are not included, this leads to a LF Hamiltonian equation which describes the bound-state dynamics of light hadrons in terms of an invariant impact variable {zeta} which measures the separation of the partons within the hadron at equal light-front time {tau} = x{sup 0} + x{sup 3}. This allows us to identify the holographic variable z in AdS space with an impact variable {zeta}. The resulting Lorentz-invariant Schroedinger equation for general spin incorporates color confinement and is systematically improvable. Light-front holographic methods were originally introduced by matching the electromagnetic current matrix elements in AdS space with the corresponding expression using LF theory in physical space time. It was also shown that one obtains identical holographic mapping using the matrix elements of the energy-momentum tensor by perturbing the AdS metric around its static solution. A gravity dual to QCD is not known, but the mechanisms of confinement can be incorporated in the gauge/gravity correspondence by modifying the AdS geometry in the large infrared (IR) domain z {approx} 1 = {Lambda}{sub QCD}, which also sets the scale of the strong interactions. In this simplified approach we consider the propagation of hadronic modes in a fixed effective gravitational background asymptotic to AdS space, which encodes salient properties of the QCD dual theory, such as the ultraviolet (UV) conformal limit at the AdS boundary, as well as modifications of the background geometry in the large z IR region to describe confinement. The modified theory generates the point-like hard behavior expected from QCD, instead of the soft behavior characteristic of extended objects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗