Portable current source for 50 T and 200 T magnetic field coils for cluster fusion experiments.
No abstract prepared.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
The radiation oncology community has witnessed growing interest in observational research conducted using large-scale data sources such as registries and claims-based data sets. With the growing emphasis on observational analyses in health care, the radiation oncology community must possess a sophisticated understanding of the methodological considerations of such studies in order to evaluate evidence appropriately to guide practice and policy. Because observational research has unique features that distinguish it from clinical trials and other forms of traditional radiation oncology research, the International Journal of Radiation Oncology, Biology, Physics assembled a panel of experts in health services research to provide a concise and well-referenced review, intended to be informative for the lay reader, as well as for scholars who wish to embark on such research without prior experience. This review begins by discussing the types of research questions relevant to radiation oncology that large-scale databases may help illuminate. It then describes major potential data sources for such endeavors, including information regarding access and insights regarding the strengths and limitations of each. Finally, it provides guidance regarding the analytical challenges that observational studies must confront, along with discussion of the techniques that have been developed to help minimize the impact of certain common analytical issues in observational analysis. Features characterizing a well-designed observational study include clearly defined research questions, careful selection of an appropriate data source, consultation with investigators with relevant methodological expertise, inclusion of sensitivity analyses, caution not to overinterpret small but significant differences, and recognition of limitations when trying to evaluate causality. This review concludes that carefully designed and executed studies using observational data that possess these qualities hold substantial promise for advancing our understanding of many unanswered questions of importance to the field of radiation oncology.
A two-fluid model developed originally to describe wave oscillations in the vacuum arc centrifuge, a cylindrical, rapidly rotating, low temperature, and confined plasma column, is applied to interpret plasma oscillations in a RF generated linear magnetized plasma [WOMBAT (waves on magnetized beams and turbulence)], with similar density and field strength. Compared to typical centrifuge plasmas, WOMBAT plasmas have slower normalized rotation frequency, lower temperature, and lower axial velocity. Despite these differences, the two-fluid model provides a consistent description of the WOMBAT plasma configuration and yields qualitative agreement between measured and predicted wave oscillation frequencies with axial field strength. In addition, the radial profile of the density perturbation predicted by this model is consistent with the data. Parameter scans show that the dispersion curve is sensitive to the axial field strength and the electron temperature, and the dependence of oscillation frequency with electron temperature matches the experiment. These results consolidate earlier claims that the density and floating potential oscillations are a resistive drift mode, driven by the density gradient. To our knowledge, this is the first detailed physics model of flowing plasmas in the diffusion region away from the RF source. Possible extensions to the model, including temperature nonuniformity and magnetic field oscillations, are also discussed.
Progress in inertial confinement fusion depends on the accurate interpretation of experiments that are complex and difficult to explain with simulations. Results could depend on small changes in the laser pulse or target or physics that are not fully understood or characterized. In this paper we discuss an x-ray-driven platform with fewer sources of degradation, and find the fusion yield can be described as a physically motivated function of laser energy, target scale, and implosion symmetry. Furthermore, this platform and analysis could enable a more experimental approach to the study and optimization of implosion physics.
An experiment has been devised which will validate, in space, a miniature, high-performance receiver. The receiver blends three complementary technologies; high temperature superconductivity (HTS), pseudomorphic high electron mobility transistor (PHEMT) monolithic microwave integrated circuits (MMIC), and a miniature pulse tube cryogenic cooler. Specifically, an HTS band pass filter, InP MMIC low noise amplifier, HTS-sapphire resonator stabilized local oscillator (LO), and a miniature pulse tube cooler will be integrated into a complete 20 GHz receiver downconverter. This cooled downconverter will be interfaced with customized signal processing electronics and integrated onto the space shuttle's 'HitchHiker' carrier. A pseudorandom data sequence will be transmitted to the receiver, which is in low Earth orbit (LEO), via the Advanced Communication Technology Satellite (ACTS) on a 20 GHz carrier. The modulation format is QPSK and the data rate is 2.048 Mbps. The bit error rate (BER) will be measured in situ. The receiver is also equipped with a radiometer mode so that experiment success is not totally contingent upon the BER measurement. In this mode, the receiver uses the Earth and deep space as a hot and cold calibration source, respectively. The experiment closely simulates an actual cross-link scenario. Since the receiver performance depends on channel conditions, its true characteristics would be masked in a terrestrial measurement by atmospheric absorption and background radiation. Furthermore, the receiver's performance depends on its physical temperature, which is a sensitive function of platform environment, thermal design, and cryocooler performance. This empirical data is important for building confidence in the technology.
The envelopes of molecular gas around embedded low-mass protostars show different chemistries, which can be used to trace their formation history and physical conditions. The excitation conditions of some molecular species can also be used to trace these physical conditions, making it possible to constrain for instance sources of heating and excitation. Aims. We study the range of influence of an intermediate-mass Herbig Be protostar. We also study the effect of feedback from the environment on the chemical and physical properties of embedded protostars. Methods. We followed up on an earlier line survey of the Class 0I source R CrA IRS7B in the 0.8 mm window with an unbiased line survey of the same source in the 1.3 mm window using the Atacama Pathfinder Experiment (APEX) telescope. We also studied the excitation of the key species H2CO, CH3OH, and c-C3H2 in a complete sample of the 18 embedded protostars in the Corona Australis star-forming region. Radiative transfer models were employed to establish abundances of the molecular species. Results. We detect line emission from 20 molecular species (32 including isotopologues) in the two surveys. The most complex species detected are CH3OH, CH3CCH, CH3CHO, and CH3CN (the latter two are only tentatively detected). CH3CN and several other complex organic molecules are significantly under-abundant in comparison with what is found towards hot corino protostars. The H2CO rotational temperatures of the sources in the region decrease with the distance to the Herbig Be star R CrA, whereas the c-C3H2 temperatures remain constant across the star-forming region.Conclusions. The high H2CO temperatures observed towards objects close to R CrA suggest that this star has a sphere of influence of several 10 000 AU in which it increases the temperature of the molecular gas to 3050 K through irradiation. The chemistry in the IRS7B envelope differs significantly from many other embedded protostars, which could be an effect of the external irradiation from R CrA.
The 13th annual U.S. National School on Neutron and X-ray Scattering was held June 11 to 25, 2011, at both Oak Ridge and Argonne National Laboratories. This school brought together 65 early career graduate students from 56 different universities in the US and provided them with a broad introduction to the techniques available at the major large-scale neutron and synchrotron x-ray facilities. This school is focused primarily on techniques relevant to the physical sciences, but also touches on cross-disciplinary bio-related scattering measurements. During the school, students received lectures by over 30 researchers from academia, industry, and national laboratories and participated in a number of short demonstration experiments at Argonne's Advanced Photon Source (APS) and Oak Ridge's Spallation neutron Source (SNS) and High Flux Isotope Reactor (HFIR) facilities to get hands-on experience in using neutron and synchrotron sources. The first week of this year's school was held at Oak Ridge National Lab, where Lab director Thom Mason welcomed the students and provided a shitorical perspective of the neutron and x-ray facilities both at Oak Ridge and Argonne. The first few days of the school were dedicated to lectures laying out the basics of scattering theory and the differences and complementarity between the neutron and x-ray probes given by Sunil Sinha. Jack Carpenter provided an introduction into how neutrons are generated and detected. After this basic introduction, the students received lectures each morning on specific techniques and conducted demonstration experiments each afternoon on one of 15 different instruments at either the SNS or HFIR. Some of the topics covered during this week of the school included inelastic neutron scattering by Bruce Gaulin, x-ray and neutron reflectivity by Chuck Majkrazak, small-angle scattering by Volker Urban, powder diffraction by Ashfia Huq and diffuse scattering by Gene Ice.
The world record fusion power production is 16.1 MW (5.7x10{sup 18} n/s). This was achieved at JET in 1995. The neutron budget during that experimental campaign was 2.5x10{sup 20} neutrons. In the first few seconds of an ITER full power pulse, the neutron production will exceed that the total from the entire history of previous controlled fusion experiments. It is envisaged that ITER should produce as much as 700 MW of fusion power. (This is the maximum envisaged power production from the plasma and does not include power multiplication in the blankets or shielding). This equates to the production of 2.48x10{sup 20} 14-MeV neutrons/s which will give an uncollided flux at the first wall of approximately 4x10{sup 13} n/cm{sup 2}/s and a total with the addition of the collided flux of some 10{sup 14} n/cm{sup 2}/s. For safety and licensing purposes it is the responsibility of ITER to satisfy the host state regulations and must limit doses to the public and staff. Furthermore, sufficient shielding must be provided to ensure that all components function adequately; and for decommissioning, ITER has a responsibility to reduce the volume and radio-toxicity of waste. The construction, operational and decommissioning phases of ITER are expected to last in excess of 30 years and the nuclear issues will be of critical importance throughout this time. The huge leap in neutron production in fusion experiments means that extensive nuclear analysis is required for ITER and it is the thesis of this paper that it is required at an unprecedented level. This is because of the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry and the complexity of the sources and level of detail required. As a result of this unprecedented challenge the latest techniques for analysis, variance reduction and data display are being employed and in some cases being specifically developed. In this paper a few of the many representative examples of nuclear analysis will illustrate the thesis. The paper includes an examination of areas where further development could be made in the areas of radiation shield and nuclear analysis. Extensive nuclear analysis is required at ITER and the combination of the large physical size of the installation, the variety of radiation sources, the attenuation required, the complexity of the geometry, and the complexity of the sources mean that analysis is required at an unprecedented level of detail and quality. The latest techniques for analysis, variation reduction and data display are being employed and in some cases being specifically developed. Developments are required in areas of analysis, data visualization and experimental verification. (author)
Measuring the profile of a high-intensity proton beam is problematic in that traditional invasive techniques such as flying wires don't survive the encounter with the beam. One alternative is the use of an electron beam as a probe of the charge distribution in the proton beam as was done at the Spallation Neutron Source at ORNL. Here we present an initial characterization of the beam from a commercial electron gun from Kimball Physics, intended for use in the Fermilab Main Injector for Project X. Despite the fact that the horizontal spot size is abnormally large in the high current measurement, the spot size at the downstream cross X2 is reasonable in the context of measuring the deflection. A thin foil OTR would help with the beam heating and should be tried. The next phase of this experiment is to simulate the proton beam with a pair of current carrying wires and to design and construct a fast deflector. Some of the remaining issues to be considered include determining the minimum beam current needed to observe the deflected beam for a given sweep time and the impact of longitudinal variations in the charge density of the bunch.
Double frequency heating (DFH) is a tool to improve the output of highly charged ions particularly from modern electron cyclotron resonance ion source installations with very high RF-frequencies. In order to gain information on the DFH-mechanism and on the role of the lower injected frequency we have carried out a series of dedicated experiments where we have put emphasis on the creation of a discrete resonance surface also for this lower frequency. Our well-established method of inserting an emissive MD (metal-dielectric) liner into the plasma chamber of the source is used in these experiments as a tool of investigation. In this way, the electron temperature and density for both ECR zones is increased in a controlled manner, allowing conclusions on the role of the change of the electron-energy-distribution function with and without DFH.
The temperature dependence of neutron-rich isotope yields was studied within the framework of the HRIBF-SPES Radioactive Ion Beams (RIB) project. On-line release measurements of fission fragments from a uranium carbide target at 1600 C, 1800 C and 2000 C were performed at ORNL (USA). The fission reactions were induced by a 40 MeV proton beam accelerated into a uranium carbide target coupled to a plasma ion source. The experiments allowed for tests of performance of the SPES multi-foil target prototype loaded with seven UC{sub 2}/graphite discs (ratio C/U = 4) with density about 4 g/cm{sup 3}.
The degree to which a given physical subdivision of a critical reactor acts as a neutron source for other lobes is not analytically characterized for general application. ATR and ATRC both operate at power, and individual power-producing lobes rely on each other as neutron sources in order to maintain constant power, which in general requires either exactly critical multiplication within a reactor or an external neutron source. Here, this work shows that lobe powers in ATR or ATRC can be related with subcritical multiplication theory, demonstrating that the lobes are not individually critical. This explanation is significant for ATR due to the desire to irradiate a large variety of experiments simultaneously, each having its impact on the core neutron population. This work also establishes the lack of relationship between experiment reactivity worth and cross-sections calculated from fundamental nuclear data. For any physical subdivision of any other critical reactor, it is likewise true that the subdivision undergoes only subcritical multiplication.
The authors provide observations from the AIAA Drag Prediction Workshops that have spanned over a decade and from a recent validation experiment at NASA Langley. These workshops provide an assessment of the predictive capability of forces and moments, focused on drag, for transonic transports. It is very difficult to manage the consistency of results in a workshop setting to perform verification and validation at the scientific level, but it may be sufficient to assess it at the level of practice. Observations thus far: 1) due to simplifications in the workshop test cases, wind tunnel data are not necessarily the “correct” results that CFD should match, 2) an average of core CFD data are not necessarily a better estimate of the true solution as it is merely an average of other solutions and has many coupled sources of variation, 3) outlier solutions should be investigated and understood, and 4) the DPW series does not have the systematic build up and definition on both the computational and experimental side that is required for detailed verification and validation. Several observations regarding the importance of the grid, effects of physical modeling, benefits of open forums, and guidance for validation experiments are discussed. The increased variation in results when predicting regions of flow separation and increased variation due to interaction effects, e.g., fuselage and horizontal tail, point out the need for validation data sets for these important flow phenomena. Experiences with a recent validation experiment at NASA Langley are included to provide guidance on validation experiments.
Purpose: To study how eyeglass design features and postures of the interventional radiologist affect the radiation dose to the lens of the eye. Methods: A mesh-based deformable phantom, consisting of an ultra-fine eye model, was used to simulate postures of a radiologist in fluoroscopically guided interventional procedure (facing the patient, 45 degree to the left, and 45 degree to the right). Various eyewear design features were studied, including the shape, lead-equivalent thickness, and separation from the face. The MCNPX Monte Carlo code was used to simulate the X-ray source used for the transcatheter arterial chemoembolization procedure (The X-ray tube is located 35 cm from the ground, emitting X-rays toward to the ceiling; Field size is 40cm X 40cm; X-ray tube voltage is 90 kVp). Experiments were also performed using dosimeter placed on a physical phantom behind eyeglasses. Results: Without protective eyewear, the radiologist’s eye lens can receive an annual dose equivalent of about 80 mSv. When wearing a pair of lead eyeglasses with lead-equivalent of 0.5-mm Pb, the annual dose equivalent of the eye lens is reduced to 31.47 mSv, but both exceed the new ICRP limit of 20 mSv. A face shield with a lead-equivalent of 0.125-mm Pb in the shape of a semi-cylinder (13cm in radius and 20-cm in height) would further reduce the exposure to the lens of the eye. Examination of postures and eyeglass features reveal surprising information, including that the glass-to-eye separation also plays an important role in the dose to the eye lens from scattered X-ray from underneath and the side. Results are in general agreement with measurements. Conclusion: There is an urgent need to further understand the relationship between the radiation environment and the radiologist’s eyewear and posture in order to provide necessary protection to the interventional radiologists under newly reduced dose limits.
Fermilab has been working with the international particle physics and nuclear physics communities to explore and develop research programs possible with a new high intensity proton source known as 'Project-X'. Project X will provide multi-megawatt proton beams from the Fermilab Main Injector over the energy range 60-120 GeV simultaneous with multi-megawatt protons beams at 3 GeV with very flexible beam-timing characteristics and up to 300 kW of pulsed beam at 8 GeV. The Project-X research program includes world leading sensitivity in longbaseline neutrino experiments, neutrino scattering experiments, a rich program of ultra-rare muon and kaon decays, opportunities for next-generation electric dipole moment experiments and other nuclear/particle physics probes that reach far beyond the Standard Model.
The high x-ray flux available at synchrotron radiation sources can cause nonlinearities in photon-counting detectors unless deadtime corrections are employed. We compute the uncertainties associated with several common deadtime-correction formulas. At lower countrates, statistical noise dominates the error in the measured countrates; at higher countrates, the dominating factors are saturation of the response and uncertainty in the value of the deadtime parameter. In between, a range of countrates exists in which the signal-to-noise ratio can be optimized for photon-counting experiments.
Space-charge neutralization is required to compress and focus a pulsed, high-current ion beam on a target for warm dense matter physics or heavy ion fusion experiments. We described approaches to produce dense plasma in and near the final focusing solenoid through which the ion beam travels, thereby providing an opportunity for the beam to acquire the necessary space-charge compensating electrons. Among the options are plasma injection from pulsed vacuum arc sources located outside the solenoid, and using a high current (> 4 kA) pulsed vacuum arc plasma from a ring cathode near the edge of the solenoid. The plasma distribution is characterized by photographic means, by an array of movable Langmuir probes, by a small single probe, and by evaluating Stark broadening of the Balmer H beta spectral line. In the main approach described here, the plasma is produced at several cathode spots distributed azimuthally on the ring cathode. It is shown that the plasma is essentially hollow, as determined by the structure of the magnetic field, though the plasma density exceeds 1014 cm-3 in practically all zones of the solenoid volume if the ring electrode is placed a few centimeters off the center of the solenoid. The plasma is non-uniform and fluctuating, however, since its density exceeds the ion beam density it is believed that this approach could provide a practical solution to the space charge neutralization challenge.
We analyse the excess in the γ-ray emission from the center of our galaxy observed by Fermi-LAT in terms of dark matter annihilation within the scalar Higgs portal model. In particular, we include the astrophysical uncertainties from the dark matter distribution and allow for unspecified additional dark matter components. We demonstrate through a detailed numerical fit that the strength and shape of the γ-ray spectrum can indeed be described by the model in various regions of dark matter masses and couplings. Constraints from invisible Higgs decays, direct dark matter searches, indirect searches in dwarf galaxies and for γ-ray lines, and constraints from the dark matter relic density reduce the parameter space to dark matter masses near the Higgs resonance. We find two viable regions: one where the Higgs-dark matter coupling is of O(10{sup −2}), and an additional dark matter component beyond the scalar WIMP of our model is preferred, and one region where the Higgs-dark matter coupling may be significantly smaller, but where the scalar WIMP constitutes a significant fraction or even all of dark matter. Both viable regions are hard to probe in future direct detection and collider experiments.