Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes↗

Validation study of RWM stability in DIII-D high- β N plasmas

The n = 1 (n is the toroidal mode number) resistive wall mode (RWM) stability is numerically investigated for two DIII-D high-β N discharges 176440 and 172461, utilizing the MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) and MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) codes. Systematic validation efforts are attempted, for the first time, for discharges with very slow or vanishing toroidal flow for a large fraction of the plasma volume. While gaining physics insights in accessing stable operation regime at β N exceeding the Troyon no-wall limit in these slow-rotation experiments, the predictive capability of fluid and non-perturbative magnetohydrodynamic-kinetic hybrid models for the RWM is further confirmed. The MARS-F fluid model, with a strong but numerically tunable viscosity mimicking ion Landau damping of parallel sound waves, finds complete stabilization of the n = 1 RWM in the considered DIII-D plasmas under the experimental flow conditions. Similarly, either full stabilization (for discharge 176440) or marginal stability (for discharge 172461) of the mode is computed by the MARS-K hybrid model, which is first-principle based without free model parameters. In particular, all drift kinetic resonances, including those of thermal and energetic particles, are found to synergistically act to marginally stabilize the RWM in discharge 172461. These MARS-F/K modeling results explain the experimentally observed stable operational regime in DIII-D, as far as the RWM stability is concerned. Extensive numerical sensitivity studies, with respect to the plasma toroidal flow speed as well as the radial location of the resistive wall, are also carried out to further support the validation study.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stabilizing moduli with thermal matter and nonperturbative effects

Even with recent progress, it is still very much an open question to understand how all compactification moduli are stabilized, since there are several mechanisms. For example, it is possible to generate a scalar potential either classically or through nonperturbative effects, such as gaugino condensation. Such a potential can stabilize certain of the moduli fields, for example, the dilaton. On the other hand, a background of thermal matter with moduli-dependent masses can also stabilize certain of the moduli, e.g., the radion. It is important to understand whether these two distinct mechanisms are compatible with each other, that is, that there are no interference terms that could spoil the moduli stabilization. In this paper, we study heterotic string theory on an N=1 orbifold near an enhanced symmetry point. We then consider both a nonperturbatively generated potential and a gas of strings with moduli-dependent masses to stabilize the dilaton and radial modulus, respectively. We conclude that, given certain approximations, these two moduli stabilization mechanisms are compatible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

A Stability Analysis Tool for Bulk Power Systems Using Black-Box Models of Inverter-Based Resources

This paper presents a small-signal stability analysis tool for large-scale power systems with high penetration of inverter-based resources (IBRs). Firstly, a network transfer function matrix (NTFM), which represents the information of the system topology, transmission lines, loads, IBRs locations, etc., is derived to model the entire power system network. Secondly, small-signal perturbation method is applied to obtain the sequence impedance/admittance models of the block-box IBRs considering the frequency cross-coupling effects. With the obtained NTFM as well as IBR models, a multi-input, multi-output (MIMO) feedback system is constructed, and the generalized Nyquist criterion (GNC)-based stability method is employed to analyze the stability of the entire power system. Furthermore, based on the developed stability analysis method, sensitivity analysis is conducted on an unstable case to identify which parameter has a high impact on the system stability. As a result, different test cases based on a modified IEEE 14- bus system as well as a reduced 240-bus WECC system are studied to verify the proposed stability analysis tool.

42 ENGINEERING↗

DC Microgrids–Part I: A Review of Control Strategies and Stabilization Techniques

This paper presents a review of control strategies, stability analysis, and stabilization techniques for dc microgrids (MGs). Overall control is systematically classified into local and coordinated control levels according to respective functionalities in each level. As opposed to local control, which relies only on local measurements, some line of communication between units needs to be made available in order to achieve the coordinated control. Depending on the communication method, three basic coordinated control strategies can be distinguished, i.e., decentralized, centralized, and distributed control. Decentralized control can be regarded as an extension of the local control since it is also based exclusively on local measurements. In contrast, centralized and distributed control strategies rely on digital communication technologies. A number of approaches using these three coordinated control strategies to achieve various control objectives are reviewed in this paper. Moreover, properties of dc MG dynamics and stability are discussed. This paper illustrates that tightly regulated point-of-load converters tend to reduce the stability margins of the system since they introduce negative impedances, which can potentially oscillate with lightly damped power supply input filters. It is also demonstrated that how the stability of the whole system is defined by the relationship of the source and load impedances, referred to as the minor loop gain. Several prominent specifications for the minor loop gain are reviewed. Finally, a number of active stabilization techniques are presented.

30 DIRECT ENERGY CONVERSION↗

Investigation of Relevant Distribution System Representation With DG for Voltage Stability Margin Assessment

This paper emphasizes the importance of including unbalanced distribution systems for voltage stability studies in power systems. The paper aims to: discuss the various simulation methods for power system analysis; highlight the need for modeling unbalanced distribution system for accurate load margin assessment; demonstrate the influence of net-load unbalance (NLU) on voltage stability margin (VSM). We also share a T&D co-simulation interface with commercial power system solvers. The distribution system is evolving rapidly with high proliferation of distributed energy resources (DERs); these are not guaranteed to proliferate in a balanced manner and uncertainty resulting due to these DERs is well acknowledged. These uncertainties cannot be captured or visualized without representing the distribution system in detail along with the transmission system. We show the impact of proliferation of DERs in various 3-phase proportions on voltage stability margin through T&D co-simulation. We also study the impact of volt/VAR control on voltage stability margin. This analysis is only possible by representing the distribution system in detail through T&D co-simulation. In conclusion, higher percentage of net-load unbalance (NLU) in distribution system aggravates the voltage stability margin of the distribution system, which can further negatively influence the overall voltage stability margin of the system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Low-Frequency Stability Analysis of Inverter-Based Islanded Multiple-Bus AC Microgrids Based on Terminal Characteristics

For system planning of three-phase inverter-based islanded ac microgrids, the low frequency instability issue caused by interactions of inverter droop controllers is a major concern. When internal control information of procured commercial inverters is unknown, impedance-based small-signal stability criteria facilitate prediction of resonances in medium and high frequency ranges, but they usually assume the grid fundamental frequency as constant and thus they are incapable of analyzing the low-frequency oscillation of the fundamental frequency in islanded microgrids. Aiming at solving this issue, this paper proposes two stability analysis methods based on terminal characteristics of inverters and passive connection network including the dynamics of the fundamental frequency for analysis of low-frequency stability in islanded multiple-bus microgrids. Based on the Component Connection Method (CCM) to systematically separate inverters from the passive connection network, a general approach is developed to model the microgrid as a multiple-input-multiple-output (MIMO) negative feedback system in the common system d-q reference frame. By applying the generalized Nyquist stability criterion (GNC) to the return-ratio and return-difference matrices of the MIMO system model, the low-frequency stability related to the fundamental frequency can be analyzed using the measured terminal characteristics of inverters. Finally, analysis and simulation of a 37-bus microgrid verify the effectiveness of the proposed stability analysis methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Molecular Basis of Differential B-Pentamer Stability of Shiga Toxins 1 and 2

Escherichia coli strain O157:H7 is a major cause of food poisoning that can result in severe diarrhea and, in some cases, renal failure. The pathogenesis of E. coli O157:H7 is in large part due to the production of Shiga toxin (Stx), an AB{sub 5} toxin that consists of a ribosomal RNA-cleaving A-subunit surrounded by a pentamer of receptor-binding B subunits. There are two major isoforms, Stx1 and Stx2, which differ dramatically in potency despite having 57% sequence identity. Animal studies and epidemiological studies show Stx2 is associated with more severe disease. Although the molecular basis of this difference is unknown, data suggest it is associated with the B-subunit. Mass spectrometry studies have suggested differential B-pentamer stability between Stx1 and Stx2. We have examined the relative stability of the B-pentamers in solution. Analytical ultracentrifugation using purified B-subunits demonstrates that Stx2B, the more deadly isoform, shows decreased pentamer stability compared to Stx1B (EC{sub 50} = 2.3 {micro}M vs. EC{sub 50} = 0.043 {micro}M for Stx1B). X-ray crystal structures of Stx1B and Stx2B identified a glutamine in Stx2 (versus leucine in Stx1) within the otherwise strongly hydrophobic interface between B-subunits. Interchanging these residues switches the stability phenotype of the B-pentamers of Stx1 and Stx2, as demonstrated by analytical ultracentrifugation and circular dichroism. These studies demonstrate a profound difference in stability of the B-pentamers in Stx1 and Stx2, illustrate the mechanistic basis for this differential stability, and provide novel reagents to test the basis for differential pathogenicity of these toxins.

59 BASIC BIOLOGICAL SCIENCES↗

Technical Basis for DOE Standard 3013 Equivalency Supporting Reduced Temperature Stabilization of Oxalate-Derived Plutonium Oxide Produced by the HB-Line Facility at Savannah River Site

The HB-Line (HBL) facility at the Savannah River Site (SRS) is designed to produce high-purity plutonium dioxide (PuO 2 ) which is suitable for future use in production of Mixed Oxide (MOX) fuel. The MOX Fuel Fabrication Facility (MFFF) requires PuO 2 feed to be packaged per the U.S. Department of Energy (DOE) Standard 3013 (DOE-STD-3013) to comply with the facility's safety basis. The stabilization conditions imposed by DOE-STD-3013 for PuO 2 (i.e., 950 °C for 2 hours) preclude use of the HBL PuO 2 in direct fuel fabrication and reduce the value of the HBL product as MFFF feedstock. Consequently, HBL initiated a technical evaluation to define acceptable operating conditions for production of high-purity PuO 2 that fulfills the DOE-STD-3013 criteria for safe storage. The purpose of this document is to demonstrate that within the defined operating conditions, the HBL process will be equivalent for meeting the requirements of the DOE-STD-3013 stabilization process for plutonium-bearing materials from the DOE complex. The proposed 3013 equivalency reduces the prescribed stabilization temperature for high-purity PuO 2 from oxalate precipitation processes from 950 °C to 640 °C and places a limit of 60% on the relative humidity (RH) at the lowest material temperature. The equivalency is limited to material produced using the HBL established flow sheet, for example, nitric acid anion exchange and Pu(IV) direct strike oxalate precipitation with stabilization at a minimum temperature of 640 °C for four hours (h). The product purity must meet the MFFF acceptance criteria of 23,600 µg/g Pu (i.e., 2.1 wt %) total impurities and chloride content less than 250 µg/g of Pu. All other stabilization and packaging criteria identified by DOE-STD-3013-2012 or earlier revisions of the standard apply. Based on the evaluation of test data discussed in this document, the expert judgment of the authors supports packaging the HBL product under a 3013 equivalency. Under the defined process conditions and associated material specifications, the high-purity PuO 2 produced in HBL presents no unique safety concerns for packaging or storage in the 3013 required configuration. The PuO 2 produced using the HBL flow sheet conditions will have a higher specific surface area (SSA) than PuO 2 stabilized at 950 °C and, consequently, under identical conditions will adsorb more water from the atmosphere. The greatest challenge to HBL operators will be controlling moisture content below 0.5 wt %. However, even at the 0.5 wt % moisture limit, the maximum acceptable pressure of a stoichiometric mixture of hydrogen and oxygen in the 3013 container is greater than the maximum possible pressure for the HBL PuO 2 product.

08 HYDROGEN↗

Stabilization of Fast Pyrolysis Oil: Post Processing (Final Report)

UOP LLC, a Honeywell Company, assembled a comprehensive team for a two-year project to demonstrate innovative methods for the stabilization of pyrolysis oil in accordance with DOE Funding Opportunity Announcement (FOA) DE-PS36-08GO98018, Biomass Fast Pyrolysis Oil (Bio-oil) Stabilization. In collaboration with NREL, PNNL, the USDA Agricultural Research Service (ARS), Pall Fuels and Chemicals, and Ensyn Corporation, UOP developed solutions to the key technical challenges outlined in the FOA. The UOP team proposed a multi-track technical approach for pyrolysis oil stabilization. Conceptually, methods for pyrolysis oil stabilization can be employed during one or both of two stages: (1) during the pyrolysis process (In Process); or (2) after condensation of the resulting vapor (Post-Process). Stabilization methods fall into two distinct classes: those that modify the chemical composition of the pyrolysis oil, making it less reactive; and those that remove destabilizing components from the pyrolysis oil. During the project, the team investigated methods from both classes that were suitable for application in each stage of the pyrolysis process. The post processing stabilization effort performed at PNNL is described in this report. The effort reported here was performed under a CRADA between PNNL and UOP, which was effective on March 13, 2009, for 2 years and was subsequently modified March 8, 2011, to extend the term to December 31, 2011.

09 BIOMASS FUELS↗

Moisture Stability of Sulfide Solid-State Electrolytes

In this report we detail a comprehensive study on the moisture stability of sulfide solid-state electrolytes in dry room environments. Although sulfide SSEs have many favorable attributes, this class of materials suffers from poor stability with water. Sulfide SSEs react with water to form gaseous H 2 S and a variety of solid byproducts like Li 3 PO 4 and LiOH, which go on to increase the interfacial impedance of solid-state batteries. Lab-scale research typically utilizes gloveboxes with <1 ppm water, however, the large-scale manufacturing of Li-ion batteries occurs in –40°C dewpoint dry rooms with around 126 ppm water. Consequently, the moisture stability of sulfide SSEs must be addressed if the manufacture of solid-state batteries based on sulfide SSEs is to be scaled up. Here, we are the first to characterize the moisture stability of sulfide SSEs according to both H 2 S and the degradation of ionic conductivity at different moisture setpoints ranging from –76°C to –40°C dewpoint. A variety of different SSE compositions are studied; namely, (Li 2 S) 75 (P 2 S 5 ) 25 , (Li 2 S) 70 (P 2 S 5 ) 30 , (Li 2 O) 7 (Li 2 S) 68 (P 2 S 5 ) 25 , (Li 2 O) 7 (Li 2 S) 63 (P 2 S 5 ) 30 , and (Li 2 S) 75 (P 2 S 5 ) 25 + 20 mol% LiI. We find that moisture stability improves with 75 mol% Li2S modifier content and the introduction of a Li 2 O co-modifier. After a 30 min exposure in a –40°C dewpoint dry room environment we found that (Li 2 S) 75 (P 2 S 5 ) 25 + 20 mol% LiI powder generated 0.1 cc/g H 2 S and its ionic conductivity decreased by over 50%. However, when SSE powder was exposed as a slurry in a dodecane carrier the same SSE composition generated 0 cc/g H 2 S and its ionic conductivity only dropped by 14%. Our results show that sulfide SSEs have acceptable moisture stability when appropriately processed in a dry room environment.

25 ENERGY STORAGE↗

Analyzing Impact of Distributed PV Generation on Integrated Transmission & Distribution System Voltage Stability—A Graph Trace Analysis Based Approach

The use of a Graph Trace Analysis (GTA)-based power flow for analyzing the voltage stability of integrated Transmission and Distribution (T&D) networks is discussed in the context of distributed Photovoltaic (PV) generation. The voltage stability of lines and the load carrying capability of buses is analyzed at various PV penetration levels. It is shown that as the PV generation levels increase, an increase in the steady state voltage stability of the system is observed. Moreover, within certain regions of stability margin changes, changes in voltage stability margins of transmission lines are shown to be linearly related to changes in the loading of the lines. Two case studies are presented, where one case study involves a model with eight voltage levels and 784,000 nodes. In one case study, a voltage-stability heat map is used to demonstrate the identification of weak lines and buses.

14 SOLAR ENERGY↗

A versatile technique to enable sub-milli-Kelvin instrument stability for precise radial velocity measurements: tests with the habitable-zone planet finder

Insufficient instrument thermomechanical stability is one of the many roadblocks for achieving 10 cm s{sup −1} Doppler radial velocity precision, the precision needed to detect Earth-twins orbiting solar-type stars. Highly temperature and pressure stabilized spectrographs allow us to better calibrate out instrumental drifts, thereby helping in distinguishing instrumental noise from astrophysical stellar signals. We present the design and performance of the Environmental Control System (ECS) for the Habitable-zone Planet Finder (HPF), a high-resolution (R = 50,000) fiber-fed near-infrared (NIR) spectrograph for the 10 m Hobby–Eberly Telescope at McDonald Observatory. HPF will operate at 180 K, driven by the choice of an H2RG NIR detector array with a 1.7 μm cutoff. This ECS has demonstrated 0.6 mK rms stability over 15 days at both 180 and 300 K, and maintained high-quality vacuum (<10{sup −7} Torr) over months, during long-term stability tests conducted without a planned passive thermal enclosure surrounding the vacuum chamber. This control scheme is versatile and can be applied as a blueprint to stabilize future NIR and optical high-precision Doppler instruments over a wide temperature range from ∼77 K to elevated room temperatures. A similar ECS is being implemented to stabilize NEID, the NASA/NSF NN-EXPLORE spectrograph for the 3.5 m WIYN telescope at Kitt Peak, operating at 300 K. A [full SolidWorks 3D-CAD model] and a comprehensive parts list of the HPF ECS are included with this manuscript to facilitate the adaptation of this versatile environmental control scheme in the broader astronomical community.

79 ASTRONOMY AND ASTROPHYSICS↗

Stability analysis of a one-dimensional multiphysics model of a molten salt fast reactor

Reactor designs with a fast neutron spectrum have recently moved into the research focus for possible Generation IV reactor concepts - a representative of which is the molten salt fast reactor (MSFR). In order to assess the safety and reliability of this reactor concept, it is necessary to obtain knowledge of the system behaviour. An important part of this research concerns the dynamical stability of the MSFR. Research regarding the MSFR stability so far has either been using linearized models for stability criteria or only been examining certain transients at fixed parameter values. This work delivers a comprehensive stability analysis for a non-linearized MSFR model, and a wide range of values for all relevant parameters. For this purpose, a one-dimensional MSFR model was set up, taking neutron kinetics and thermal hydraulics in the form of a system of differential equations into account. The stability of this model was investigated by means of the numerical tool MATCONT, which was used to monitor the evolution of a so-called fixed-point solution, here referring to the steady state at operating conditions of the system, while system parameters got varied. The MATCONT analyses showed no loss of stability for any of the considered parameter variations and no solutions that might co-exist in parallel with the steady-state fixed-point solution. Therefore these results indicate a stable fixed point to which all solution transients converge, making the considered MSFR model insusceptible to deviations from the equilibrium. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Interphase Stabilization of LiNi 0.5 Mn 1.5 O 4 Cathode for 5 V–Class All–Solid–State Batteries

Employing high voltage cobalt-free spinel LiNi 0.5 Mn 1.5 O 4 (LNMO) as a cathode is promising for high energy density and cost-effectiveness, but it has challenges in all-solid-state batteries (ASSBs). Here, it is revealed that the limitation of lithium argyrodite sulfide solid electrolyte (Li 6 PS 5 Cl) with the LNMO cathode is due to the intrinsic chemical incompatibility and poor oxidative stability. Through a careful analysis of the interphase of LNMO, it is elucidated that even the halide solid electrolyte (Li 3 InCl 6 ) with high oxidative stability can be decomposed to form resistive interphase layers with LNMO in ASSBs. Interestingly, with Fe-doping and a Li 3 PO 4 protective layer coating, LNMO with Li 3 InCl 6 displays stable cycle performance with a stabilized interphase at a high voltage (≈4.7 V) in ASSBs. The enhanced interfacial stability with the extended electrochemical stability window through doping and coating enables high electrochemical stability with LNMO in ASSBs. Furthermore, this work provides guidance for employing high-voltage cathodes in ASSBs and highlights the importance of stable interphases to enable stable cycling in ASSBs.

25 ENERGY STORAGE↗

Analysis of the Spectral Stability of the Generalized Runge–Kutta Methods Applied to Initial-Boundary-Value Problems for Equations of the Parabolic Type. I. Explicit Methods

We develop a general algorithm for the analysis the spectral stability of generalized multistage Runge–Kutta methods of various orders of accuracy as applied to the numerical integration with respect to time of an initial-boundary-value problem for the second-order parabolic equation. The expression for the function of spectral stability is obtained in two alternative forms: on the basis of matrix relations and in the determinant form. We study specific realizations of various generalized explicit Runge–Kutta methods and their spectral stability. It is shown that all explicit generalized Runge–Kutta methods possess the property of conditional spectral stability and the property of conditional monotonicity of the numerical solution in time whose violation leads to the appearance of false oscillations of the approximate solution. The stability function for these methods is polynomial. It is shown that the application of two-stage generalized explicit Runge–Kutta methods leads to the appearance of predictor-corrector-type schemes. In the case of nonstationary one-dimensional heat-conduction problem, on the basis of a one-stage generalized Runge–Kutta method, we obtain the classical two-layer conditionally stable explicit finite-difference scheme on a four-point template. It is demonstrated that the five-stage generalized Runge–Kutta–Merson method is characterized by the weakest condition of spectral stability as compared with all investigated explicit generalized Runge–Kutta methods.

42 ENGINEERING↗

A conserved serine residue regulates the stability of Drosophila Salvador and human WW domain-containing adaptor 45 through proteasomal degradation

Highlights: •Ser-17 is key for the stability of Drosophila Sav. •Ala mutation of Ser-17 promotes the proteasomal degradation of Sav. •Ser-17 residue is not the main target of Hpo-induced Sav stabilization. •Hpo-dependent and -independent mechanisms regulate Sav stability. •This mechanism is conserved in the homologue of Sav, human WW45. -- Abstract: The Hippo (Hpo) pathway is a conserved tumor suppressor pathway that controls organ size through the coordinated regulation of apoptosis and proliferation. Drosophila Salvador (Sav), which limits organ size, is a core component of the Hpo pathway. In this study, Ser-17 was shown to be important for the stability of Sav. Alanine mutation of Ser-17 promoted the proteasomal degradation of Sav. Destabilization and stabilization of the Sav protein mediated by alanine mutation of Ser-17 and by Hpo, respectively, were independent of each other. This implies that the stability of Sav is controlled by two mechanisms, one that is Ser-17-dependent and Hpo-independent, and another that is Ser-17-independent and Hpo-dependent. These dual mechanisms also regulated the human counterpart of Drosophila Sav, WW domain-containing adaptor 45 (WW45). The conservation of this regulation adds to its significance in normal physiology and tumorigenesis.