Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Deep Learning Parameterization of Vertical Wind Velocity Variability via Constrained Adversarial Training

Atmospheric models with typical resolution in the tenths of kilometers cannot resolve the dynamics of air parcel ascent, which varies on scales ranging from tens to hundreds of meters. Small-scale wind fluctuations are thus characterized by a subgrid distribution of vertical wind velocity W with standard deviation σ W . The parameterization of σ W is fundamental to the representation of aerosol–cloud interactions, yet it is poorly constrained. Using a novel deep learning technique, this work develops a new parameterization for σ W merging data from global storm-resolving model simulations, high-frequency retrievals of W , and climate reanalysis products. The parameterization reproduces the observed statistics of σ W and leverages learned physical relations from the model simulations to guide extrapolation beyond the observed domain. Incorporating observational data during the training phase was found to be critical for its performance. The parameterization can be applied online within large-scale atmospheric models, or offline using output from weather forecasting and reanalysis products.

54 ENVIRONMENTAL SCIENCES↗

A general framework of noise suppression in material decomposition for dual-energy CT

Purpose: As a general problem of dual-energy CT (DECT), noise amplification in material decomposition severely reduces the signal-to-noise ratio on the decomposed images compared to that on the original CT images. In this work, the authors propose a general framework of noise suppression in material decomposition for DECT. The method is based on an iterative algorithm recently developed in their group for image-domain decomposition of DECT, with an extension to include nonlinear decomposition models. The generalized framework of iterative DECT decomposition enables beam-hardening correction with simultaneous noise suppression, which improves the clinical benefits of DECT. Methods: The authors propose to suppress noise on the decomposed images of DECT using convex optimization, which is formulated in the form of least-squares estimation with smoothness regularization. Based on the design principles of a best linear unbiased estimator, the authors include the inverse of the estimated variance–covariance matrix of the decomposed images as the penalty weight in the least-squares term. Analytical formulas are derived to compute the variance–covariance matrix for decomposed images with general-form numerical or analytical decomposition. As a demonstration, the authors implement the proposed algorithm on phantom data using an empirical polynomial function of decomposition measured on a calibration scan. The polynomial coefficients are determined from the projection data acquired on a wedge phantom, and the signal decomposition is performed in the projection domain. Results: On the Catphan{sup ®}600 phantom, the proposed noise suppression method reduces the average noise standard deviation of basis material images by one to two orders of magnitude, with a superior performance on spatial resolution as shown in comparisons of line-pair images and modulation transfer function measurements. On the synthesized monoenergetic CT images, the noise standard deviation is reduced by a factor of 2–3. By using nonlinear decomposition on projections, the authors’ method effectively suppresses the streaking artifacts of beam hardening and obtains more uniform images than their previous approach based on a linear model. Similar performance of noise suppression is observed in the results of an anthropomorphic head phantom and a pediatric chest phantom generated by the proposed method. With beam-hardening correction enabled by their approach, the image spatial nonuniformity on the head phantom is reduced from around 10% on the original CT images to 4.9% on the synthesized monoenergetic CT image. On the pediatric chest phantom, their method suppresses image noise standard deviation by a factor of around 7.5, and compared with linear decomposition, it reduces the estimation error of electron densities from 33.3% to 8.6%. Conclusions: The authors propose a general framework of noise suppression in material decomposition for DECT. Phantom studies have shown the proposed method improves the image uniformity and the accuracy of electron density measurements by effective beam-hardening correction and reduces noise level without noticeable resolution loss.

60 APPLIED LIFE SCIENCES↗

SU-E-T-586: Optimal Determination of Tolerance Level for Radiation Dose Delivery Verification in An in Vivo Dosimetry System

Purpose: To statistically determine the optimal tolerance level in the verification of delivery dose compared to the planned dose in an in vivo dosimetry system in radiotherapy. Methods: The LANDAUER MicroSTARii dosimetry system with screened nanoDots (optically stimulated luminescence dosimeters) was used for in vivo dose measurements. Ideally, the measured dose should match with the planned dose and falls within a normal distribution. Any deviation from the normal distribution may be redeemed as a mismatch, therefore a potential sign of the dose misadministration. Randomly mis-positioned nanoDots can yield a continuum background distribution. A percentage difference of the measured dose to its corresponding planned dose (ΔD) can be used to analyze combined data sets for different patients. A model of a Gaussian plus a flat function was used to fit the ΔD distribution. Results: Total 434 nanoDot measurements for breast cancer patients were collected across a period of three months. The fit yields a Gaussian mean of 2.9% and a standard deviation (SD) of 5.3%. The observed shift of the mean from zero is attributed to the machine output bias and calibration of the dosimetry system. A pass interval of −2SD to +2SD was applied and a mismatch background was estimated to be 4.8%. With such a tolerance level, one can expect that 99.99% of patients should pass the verification and at most 0.011% might have a potential dose misadministration that may not be detected after 3 times of repeated measurements. After implementation, a number of new start breast cancer patients were monitored and the measured pass rate is consistent with the model prediction. Conclusion: It is feasible to implement an optimal tolerance level in order to maintain a low limit of potential dose misadministration while still to keep a relatively high pass rate in radiotherapy delivery verification.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fluidization of Group A Glass Particles: Experiments and Preliminary Validation

This work is aimed at providing reliable high-quality data from fluidization experiments. Geldart Group A glass beads are used as bed material. The fluidizing medium is air at atmospheric pressure which enters the system at 40% relative humidity. The air inlet velocity is varied over a broad range from 2 U mf to 26 U mf , where the minimum fluidization velocity, U mf , is 0.608 cm/s. There is not a significant change in the mean values of differential pressure; however, there are noticeable trends in their standard deviation values. Preliminary validation studies are performed using the open-source software Multiphase Flow with Interphase eXchanges (MFiX) developed by the National Energy Technology Laboratory (NETL). The results from Eulerian-Eulerian (MFiX-TFM, two-fluid model) and Eulerian-Lagrangian (MFiX-PIC, particle-in-cell) formulations are compared. The work presented in this report highlights the applicability of MFiX-PIC for large-scale applications, and reveals that PIC simulation offers a suitable alternative to TFM simulation when effects due to multiple components or polydispersity are significant. PIC modeling provides a readily extendible framework for such systems. However, PIC models do rely on an empirical closure for inter-particle stress. Some solution discrepancies were evident in MFiX-PIC predictions which require further analysis. As such, the study underlines the need for a systematic approach to quantify the sources of numerical uncertainty within the PIC model. However, even with known empiricism, MFiX-PIC has demonstrated considerable potential in analyzing gas-solid systems. The results obtained are encouraging and warrant further investigation to improve the predictive capability of MFiX-PIC.

36 MATERIALS SCIENCE↗

B{yields}K{sub 0}{sup *}(1430)l{sup +}l{sup -} decays in supersymmetric theories

The weak decays of B{yields}K{sub 0}*(1430)l{sup +}l{sup -} (l={mu}, {tau}) are investigated in minimal supersymmetric standard model (MSSM) and also in supersymmetric (SUSY) SO(10) grand unified theory (GUT) models. Neutral Higgs bosons are the point of main focus in MSSM because they make quite a large contribution in exclusive B{yields}X{sub s}l{sup +}l{sup -} decays at large tan{beta} regions of parameter space of SUSY models, as part of SUSY contributions is proportional to tan{sup 3}{beta}. The analysis of decay rate, forward-backward asymmetries and lepton polarization asymmetries in B{yields}K{sub 0}*(1430)l{sup +}l{sup -} show that the values of these physical observables are greatly modified by the effects of neutral Higgs bosons. In SUSY SO(10) grand unified model, the new physics contribution comes from the operators which are induced by the neutral Higgs boson penguins and also from the operators with chirality opposite to that of the corresponding standard model operators. SUSY SO(10) effects show up only in the decay B{yields}K{sub 0}{sup *}{mu}{sup +}{mu}{sup -} where the transverse lepton polarization asymmetries deviate significantly from the SM value while the effects in the decay rate, forward-backward asymmetries, the longitudinal and normal lepton polarization asymmetries are very mild. The transverse lepton polarization asymmetry is almost zero in SM and in MSSM model, whereas it can reach to -0.3 in SUSY SO(10) GUT model which could be seen at the future colliders; hence this asymmetry observable can be used to discriminate between different SUSY models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automating linear accelerator quality assurance

Purpose: The purpose of this study was 2-fold. One purpose was to develop an automated, streamlined quality assurance (QA) program for use by multiple centers. The second purpose was to evaluate machine performance over time for multiple centers using linear accelerator (Linac) log files and electronic portal images. The authors sought to evaluate variations in Linac performance to establish as a reference for other centers. Methods: The authors developed analytical software tools for a QA program using both log files and electronic portal imaging device (EPID) measurements. The first tool is a general analysis tool which can read and visually represent data in the log file. This tool, which can be used to automatically analyze patient treatment or QA log files, examines the files for Linac deviations which exceed thresholds. The second set of tools consists of a test suite of QA fields, a standard phantom, and software to collect information from the log files on deviations from the expected values. The test suite was designed to focus on the mechanical tests of the Linac to include jaw, MLC, and collimator positions during static, IMRT, and volumetric modulated arc therapy delivery. A consortium of eight institutions delivered the test suite at monthly or weekly intervals on each Linac using a standard phantom. The behavior of various components was analyzed for eight TrueBeam Linacs. Results: For the EPID and trajectory log file analysis, all observed deviations which exceeded established thresholds for Linac behavior resulted in a beam hold off. In the absence of an interlock-triggering event, the maximum observed log file deviations between the expected and actual component positions (such as MLC leaves) varied from less than 1% to 26% of published tolerance thresholds. The maximum and standard deviations of the variations due to gantry sag, collimator angle, jaw position, and MLC positions are presented. Gantry sag among Linacs was 0.336 ± 0.072 mm. The standard deviation in MLC position, as determined by EPID measurements, across the consortium was 0.33 mm for IMRT fields. With respect to the log files, the deviations between expected and actual positions for parameters were small (<0.12 mm) for all Linacs. Considering both log files and EPID measurements, all parameters were well within published tolerance values. Variations in collimator angle, MLC position, and gantry sag were also evaluated for all Linacs. Conclusions: The performance of the TrueBeam Linac model was shown to be consistent based on automated analysis of trajectory log files and EPID images acquired during delivery of a standardized test suite. The results can be compared directly to tolerance thresholds. In addition, sharing of results from standard tests across institutions can facilitate the identification of QA process and Linac changes. These reference values are presented along with the standard deviation for common tests so that the test suite can be used by other centers to evaluate their Linac performance against those in this consortium.

60 APPLIED LIFE SCIENCES↗

Very-high energy observations of the galactic center region by VERITAS in 2010-2012

The Galactic center is an interesting region for high-energy (0.1-100 GeV) and very-high-energy (E > 100 GeV) γ-ray observations. Potential sources of GeV/TeV γ-ray emission have been suggested, e.g., the accretion of matter onto the supermassive black hole, cosmic rays from a nearby supernova remnant (e.g., Sgr A East), particle acceleration in a plerion, or the annihilation of dark matter particles. The Galactic center has been detected by EGRET and by Fermi/LAT in the MeV/GeV energy band. At TeV energies, the Galactic center was detected with moderate significance by the CANGAROO and Whipple 10 m telescopes and with high significance by H.E.S.S., MAGIC, and VERITAS. We present the results from three years of VERITAS observations conducted at large zenith angles resulting in a detection of the Galactic center on the level of 18 standard deviations at energies above ∼2.5 TeV. The energy spectrum is derived and is found to be compatible with hadronic, leptonic, and hybrid emission models discussed in the literature. Future, more detailed measurements of the high-energy cutoff and better constraints on the high-energy flux variability will help to refine and/or disentangle the individual models.

79 ASTRONOMY AND ASTROPHYSICS↗

Combined Theoretical Analysis of the Parity-Violating Asymmetry for 48 Ca and 208 Pb

The recent experimental determination of the parity violating asymmetry A PV in 48 Ca and 208 Pb at Jefferson Lab is important for our understanding on how neutrons and protons arrange themselves inside the atomic nucleus. To better understand the impact of these measurements, we present a rigorous theoretical investigation of A PV in 48 Ca and 208 Pb and assess the associated uncertainties. Here, we complement our study by inspecting the static electric dipole polarizability in these nuclei. The analysis is carried out within nuclear energy density functional theory with quantified input. We conclude that the simultaneous accurate description of A PV in 48 Ca and 208 Pb cannot be achieved by our models that accommodate a pool of global nuclear properties, such as masses and charge radii, throughout the nuclear chart, and describe—within one standard deviation—the experimental dipole polarizabilities in these nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion Distributions at Electrified Water-Organic Interfaces: PB-PMF Calculations and Impedance Spectroscopy Measurements

The interface between two immiscible electrolyte solutions consisting of alkali chlorides in water and the organic electrolyte BTPPATPFB in 1,2-dichloroethane is characterized with X-ray reflectivity, interfacial tension and impedance spectroscopy measurements over a range of applied voltage between the bulk solutions. X-ray reflectivity probes the interfacial ion distribution on the sub-nanometer length scale, whereas interfacial tension and impedance spectroscopy characterize quantities such as interfacial excess charge and differential capacitance that represent integrations over the interfacial ion distribution. Predictions of interfacial ion distributions by the recently introduced PB-PMF method, which combines Poisson's equation with ion potentials of mean force, provide excellent agreement, within one to two experimental standard deviations, with both X-ray reflectivity and interfacial tension measurements. However, the agreement with the differential capacitance measured by impedance spectroscopy, and modeled by the Randles equivalent circuit, is not as good. Values of measured and calculated differential capacitance can deviate by as much as 20% for applied electric potential differences larger than approximately ±100 mV. These comparisons indicate that our understanding of the ion distributions that underlie these measurements is adequate, but that further understanding of the modeling of impedance spectroscopy data is required for quantitative agreement at larger applied electric potential differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Cylinder Oxygen Mass Fraction Estimation Method for Minimizing Cylinder-to-Cylinder Variations

Recent developments in advanced combustion engines have demonstrated the potential increases in efficiency and reductions in emissions through low temperature combustion (LTC). These combustion modes often rely on high exhaust gas recirculation (EGR), early fuel injection systems, and in some cases a combination of fuels with different reactivities. Despite the advantages of LTC, such operations are highly sensitive to the in-cylinder pre-combustion conditions and face significant challenges in multi-cylinder operation due to cylinder-to-cylinder variations of the combustion process. The cause of cylinder-to-cylinder variations is strongly tied to non-uniform trapped mass. In particular, in-cylinder oxygen concentration plays a critical role in the combustion process of each cylinder and can be leveraged to predict combustion characteristics and to develop control algorithms that mitigate cylinder-to-cylinder variation. This paper discusses a control-oriented model for estimating the in-cylinder oxygen mass fraction of each individual cylinder. The method relies on an Arrhenius correlation that establishes a relation between oxygen mass fraction, ignition delay, fuel activation energy, and in-cylinder average temperature and pressure during the ignition delay period. The scope of this study is the investigation of this relation on a single injection diesel fuel combustion in a multi-cylinder engine where the main characteristics of LTC operation, early fuel injection and high EGR, are realized. The model developed in this work accurately estimates the oxygen mass fraction of an individual cylinder in the 20 operating conditions studied with a standard deviation of 0.47% O2.

Kassa, Mateos↗

Test of QCD in multijet final states at the Tevatron

In this contribution, some of the recent QCD results on jet production from the CDF and D0 experiments in Run II of the Tevatron are discussed. In particular, results include cross section measurements for dijet and trijet production, study of jet substructure and measurements of W/Z+jets cross sections. The measurements are compared with the theoretical predictions. The QCD program at the Tevatron proton-antiproton collider revolves around the jet physics. Jets are collimated sprays of hadrons generated by the fragmentation of partons originating from the hard scattering. The measurements of jets production cross section at the Tevatron provide stringent test of perturbative QCD predictions, information on the strong coupling constant, {alpha}s, and constraints on proton parton distribution functions, PDFs. The deviations from the pQCD predictions could translate into a hint of new physics. In addition, these processes form sizable backgrounds to both, the Standard Model (SM) and beyond SM physics processes. Therefore, good understanding of jets production is essential to perform precise physics measurements or searches for new physics phenomena. In this contribution, a review of some recent QCD results from the CDF [1] and D0 [2] experiments is presented. Various analyses use proton-antiproton collision data from the Fermilab Tevatron at the center of mass energy {radical}s = 1.96 TeV corresponding to integrated luminosities of 0.7 fb{sup -1} to 8 fb{sup -1}. The results are corrected for the experimental effects and presented at the 'particle level'. The theory predictions are corrected for the hadronization and underlying effects which are obtained from the parton shower Monte Carlo (MC) simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Measurement of ZZ Production in panti-p Collisions at s**(1/2) = 1.96-TeV

We report the first measurement of the cross section for Z boson pair production at a hadron collider. This result is based on a data sample corresponding to 1.9 fb{sup -1} of integrated luminosity from p{bar p} collisions at {radical}s = 1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. In the {ell}{ell}{ell}{prime}{ell}{prime} channel, we observe three ZZ candidates with an expected background of 0.096{sub -0.063}{sup +0.092} events. In the {ell}{ell}{nu}{nu} channel, we use a leading-order calculation of the relative ZZ and WW event probabilities to discriminate between signal and background. In the combination of {ell}{ell}{ell}{prime}{ell}{prime} and {ell}{ell}{nu}{nu} channels, we observe an excess of events with a probability of 5.1 x 10{sup -6} to be due to the expected background. This corresponds to a significance of 4.4 standard deviations. The measured cross section is {sigma}(p{bar p} {yields}ZZ) = 1.4{sub -0.6}{sup +0.7} (stat.+syst.) pb, consistent with the standard model expectation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of a {sup 90}Sr/{sup 90}Y source for intra-ocular treatment of wet age-related macular degeneration

Purpose: The purpose of this study is to perform an extensive investigation of an approximately 2.5 mm long {sup 90}Sr/{sup 90}Y source designed for treating wet age-related macular degeneration. Methods: As part of this investigation, a NIST-traceable absorbed dose to water calibration technique was established, and a source deployment verification test was developed. The influence of treatment cannula construction tolerance on the measurements as well as the dose delivered to the patient was investigated using the Monte Carlo code MCNP5. Variation between production cannulae was quantified experimentally using a well-type ionization chamber, and additional measurements along with Monte Carlo calculations of the collimating insert used for source deployment verification were performed to validate the model. Results: Maximum variation in the integrated target dose was seen when the source was shifted laterally within the treatment cannula. For the well chamber measurements, the observed standard deviation in ionization current for a single source placed in different reference cannulae was {+-}0.3%, with a maximum observed range of less than {+-}0.5%. Clinical cannulae in the collimating insert showed an average of 17.8%{+-}0.4% of the reference signal when sources were fully deployed compared to 18.5% predicted by Monte Carlo calculations. This discrepancy has been attributed primarily to construction of the collimator since the collimation gap was observed to be approximately 0.025-0.075 mm smaller than specified. Construction tolerance of the well chamber insert as well as position tolerance of the cannula tip were both investigated, and their influence on the predicted signal was quantified. Additional measurements along with Monte Carlo based calculations of the collimating insert with polyethylene spacers added to the setup were performed to validate the Monte Carlo model. The shimmed Monte Carlo and measured data agree to within 1%, which is a magnitude difference of approximately 0.1% of the reference signal. Conclusions: This investigation confirms that the signal for an acceptably deployed source in the collimating insert is between 17.5% and 21.5% of the reference signal, as calculated using Monte Carlo models. Clinical cannulae for which the source deployment verification measurement falls outside the acceptable range should not be used to treat patients.

07 ISOTOPE AND RADIATION SOURCES↗

Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Uncertainty propagation through an aeroelastic wind turbine model using polynomial surrogates

Polynomial surrogates are used to characterize the energy production and lifetime equivalent fatigue loads for different components of the DTU 10 MW reference wind turbine under realistic atmospheric conditions. The variability caused by different turbulent inflow fields are captured by creating independent surrogates for the mean and standard deviation of each output with respect to the inflow realizations. A global sensitivity analysis shows that the turbulent inflow realization has a bigger impact on the total distribution of equivalent fatigue loads than the shear coefficient or yaw miss-alignment. The methodology presented extends the deterministic power and thrust coefficient curves to uncertainty models and adds new variables like damage equivalent fatigue loads in different components of the turbine. These surrogate models can then be implemented inside other work-flows such as: estimation of the uncertainty in annual energy production due to wind resource variability and/or robust wind power plant layout optimization. It can be concluded that it is possible to capture the global behavior of a modern wind turbine and its uncertainty under realistic inflow conditions using polynomial response surfaces. In conclusion, the surrogates are a way to obtain power and load estimation under site specific characteristics without sharing the proprietary aeroelastic design.

17 WIND ENERGY↗

A Stochastic Study of Flow Anisotropy and Channelling in Open Rough Fractures

The quantification of fluid flow in rough fractures is of high interest for reservoir engineering, especially for deep geothermal applications. Herein, rough self-affine fractures are stochastically generated with incremental shear displacement and geometrically described by two aperture definitions, the vertical aperture a vert and the effective aperture a eff . In order to compare their effect on fracture flow, such as anisotropy and channelling, Local Cubic Law (LCL) model-based 2D fluid flow is simulated. The particularity of this approach is the combination of a stochastic generation of self-affine fractures with a statistical analysis (560 individual realizations) of the impact of the LCL’s aperture constraint on fracture flow. The results show that aperture definition affects the quantitative interpretation of flow anisotropy and channeling as well as the aperture distribution of the fractures with shearing. Higher values of mean aperture for a given fracture are found using a vert , whereas the aperture standard deviation is larger with a eff . In addition, flow anisotropy is significantly sensitive to aperture definition for small shear displacements and shows a relative higher dispersion with a eff . Thus, LCL prediction models based on a vert are expected to lead to higher dispersion of anisotropy results with a higher uncertainty (factor ~ 2). Realizations based on avert lead to an enhanced clustering of high flow rates for higher shearing displacements. This channeling development results in higher total flow rates for these simulations. Finally, these findings support the direct calibration of pre-existing LCL anisotropy simulations based on avert towards more representative results using a eff .

58 GEOSCIENCES↗

A Method of Determining Accuracy and Precision for Dosimeter Systems Using Accreditation Data

A study of the uncertainty of dosimeter results is required by the national accreditation programs for each dosimeter model for which accreditation is sought. Typically, the methods used to determine uncertainty have included the partial differentiation method described in the U.S. Guide to Uncertainty in Measurements or the use of Monte Carlo techniques and probability distribution functions to generate simulated dose results. Each of these techniques has particular strengths and should be employed when the areas of uncertainty are required to be understood in detail. However, the uncertainty of dosimeter results can also be determined using a Model II One-Way Analysis of Variance technique and accreditation testing data. The strengths of the technique include (1) the method is straightforward and the data are provided under accreditation testing and (2) the method provides additional data for the analysis of long-term uncertainty using Statistical Process Control (SPC) techniques. The use of SPC to compare variances and standard deviations over time is described well in other areas and is not discussed in detail in this paper. The application of Analysis of Variance to historic testing data indicated that the accuracy in a representative dosimetry system (Panasonic® Model UD-802) was 8.2%, 5.1%, and 4.8% and the expanded uncertainties at the 95% confidence level were 10.7%, 14.9%, and 15.2% for the Accident, Protection Level-Shallow, and Protection Level-Deep test categories in the Department of Energy Laboratory Accreditation Program, respectively. The 95% level of confidence ranges were (0.98 to 1.19), (0.90 to 1.20), and (0.90 to 1.20) for the three groupings of test categories, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗