Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

On the Statistical Calibration of Physical Models

ABSTRACT We introduce a novel statistical calibration framework for physical models, relying on probabilistic embedding of model discrepancy error within the model. For clarity of illustration, we take the measurement errors out of consideration, calibrating a chemical model of interest with respect to a more detailed model, considered as “truth” for the present purpose. We employ Bayesian statistical methods for such model‐to‐model calibration and demonstrate their capabilities on simple synthetic models, leading to a well‐defined parameter estimation problem that employs approximate Bayesian computation. The method is then demonstrated on two case studies for calibration of kinetic rate parameters for methane air chemistry, where ignition time information from a detailed elementary‐step kinetic model is used to estimate rate coefficients of a simple chemical mechanism. We show that the calibrated model predictions fit the data and that uncertainty in these predictions is consistent in a mean‐square sense with the discrepancy from the detailed model data.

Sargsyan, K.↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Examining the Impact of Local Constraint Violations on Energy Computations in DFT

ABSTRACT This work examines the impact of locally imposed constraints in Density Functional Theory (DFT). Using a metric referred to as the extent of violation index (EVI), we quantify how well exchange‐correlation functionals adhere to local constraints. Applying EVIs to a diverse set of molecules for GGA functionals reveals constraint violations, particularly for semi‐empirical functionals. We leverage EVIs to explore potential connections between these violations and errors in chemical properties. While no correlation is observed for atomization energies, a significant statistical correlation emerges between EVIs and total energies. Similarly, the analysis of reaction energies suggests weak positive correlations for specific constraints. However, definitive conclusions about error cancellation mechanisms cannot be made at this time. These observations revealed by EVIs may be useful for consideration when designing future generations of semilocal functionals.

Khanna, Vaibhav [Department of Chemistry Universit↗

Improve earthquake hypocenter using adaptive simulated annealing inversion in regional tectonic, volcano tectonic, and geothermal observation

Observation of earthquakes is routinely used widely in tectonic activity observation, and also in local scale such as volcano tectonic and geothermal activity observation. It is necessary for determining the location of precise hypocenter which the process involves finding a hypocenter location that has minimum error between the observed and the calculated travel times. When solving this nonlinear inverse problem, simulated annealing inversion method can be applied to such global optimization problems, which the convergence of its solution is independent of the initial model. In this study, we developed own program codeby applying adaptive simulated annealing inversion in Matlab environment. We applied this method to determine earthquake hypocenter using several data cases which are regional tectonic, volcano tectonic, and geothermal field. The travel times were calculated using ray tracing shooting method. We then compared its results with the results using Geiger’s method to analyze its reliability. Our results show hypocenter location has smaller RMS error compared to the Geiger’s result that can be statistically associated with better solution. The hypocenter of earthquakes also well correlated with geological structure in the study area. Werecommend using adaptive simulated annealing inversion to relocate hypocenter location in purpose to get precise and accurate earthquake location.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hierarchical Bayesian Inverse Problems: A High-Dimensional Statistics Viewpoint

This paper analyzes hierarchical Bayesian inverse problems using techniques from highdimensional statistics. Furthermore, our analysis leverages a property of hierarchical Bayesian regularizers that we call approximate decomposability to obtain non-asymptotic bounds on the reconstruction error attained by maximum a posteriori estimators. The new theory explains how hierarchical Bayesian models that exploit sparsity, group sparsity, and sparse representations of the unknown parameter can achieve accurate reconstructions in high-dimensional settings.

MAP estimation↗

Constitutive Modeling of High-Temperature Flow Stress of Armor Steel in Ballistic Applications: A Comparative Study

Armox 500T is one of the armor grade steels extensively used as armor against bullet penetration in ballistic applications. In such applications, the material undergoes plastic deformation at large strain rates (10{sup 3} s{sup −1}) at temperatures of the order of 673-1373 K. In the present work, an attempt has been made to predict strain rate and temperature-dependent flow behavior of Armox 500T steel through physical-based model like modified Zerilli–Armstrong (M-ZA) and phenomenological-based models like Cowper Symonds (CS), modified Johnson–Cook (M-JC), Arrhenius (Arr.) and Khan–Huang–Liang (KHL) constitutive material model. Isothermal uniaxial compression tests at low strain rates (10{sup −3}-10{sup −1} s{sup −1}) and dynamic compression tests at high strain rates (600-3000 s{sup −1}) in the temperatures range of 673-1373 K have been carried out to determine constitutive material model parameters. In addition, an artificial neural network (ANN) model that works on multilayer perceptron (MLP) based back propagation neural network (BPNN) has also been developed. The results from all these models have been compared in terms of three statistical parameters namely correlation coefficient (R), mean absolute percent error (MAPE) and its standard deviation (Δ). The results revealed that M-JC model shows highest correlation coefficient and lowest average absolute error. Further, ANN model prediction has the highest accuracy with R = 0.999 and MAPE = 1.052.

36 MATERIALS SCIENCE↗

International challenge to predict the impact of radioxenon releases from medical isotope production on a comprehensive nuclear test ban treaty sampling station

Abstract The International Monitoring System (IMS) is part of the verification regime for the Comprehensive Nuclear-Test-Ban-Treaty Organization (CTBTO). At entry-into-force, half of the 80 radionuclide stations will be able to measure concentrations of several radioactive xenon isotopes produced in nuclear explosions, and then the full network may be populated with xenon monitoring afterward (Bowyer et al., 2013). Fission-based production of 99Mo for medical purposes also releases radioxenon isotopes to the atmosphere (Saey, 2009). One of the ways to mitigate the effect of emissions from medical isotope production is the use of stack monitoring data, if it were available, so that the effect of radioactive xenon emissions could be subtracted from the effect from a presumed nuclear explosion, when detected at an IMS station location. To date, no studies have addressed the impacts the time resolution or data accuracy of stack monitoring data have on predicted concentrations at an IMS station location. Recently, participants from seven nations used atmospheric transport modeling to predict the time-history of 133Xe concentration measurements at an IMS station in Germany using stack monitoring data from a medical isotope production facility in Belgium. Participants received only stack monitoring data and used the atmospheric transport model and meteorological data of their choice. Some of the models predicted the highest measured concentrations quite well (a high composite statistical model comparison rank or a small mean square error with the measured values). The results suggest release data on a 15 min time spacing is best. The model comparison rank and ensemble analysis suggests that combining multiple models may provide more accurate predicted concentrations than any single model. Further research is needed to identify optimal methods for selecting ensemble members and those methods may depend on the specific transport problem. None of the submissions based only on the stack monitoring data predicted the small measured concentrations very well. The one submission that best predicted small concentrations also included releases from nuclear power plants. Modeling of sources by other nuclear facilities with smaller releases than medical isotope production facilities may be important in discriminating those releases from releases from a nuclear explosion.

133Xe↗

Vacuum energy of two-dimensional N=(2,2) super Yang-Mills theory

We measure the vacuum energy of two-dimensional N=(2,2) super Yang-Mills theory using lattice simulation. The obtained vacuum energy density is E{sub 0}=0.09(9)((+10/-8))g{sup 2}, where the first error is the systematic and the second is the statistical one, measured in the dimensionful gauge coupling g which governs the scale of the system. The result is consistent with unbroken supersymmetry, although we cannot exclude a possible very small nonzero vacuum energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Signal, noise, and resolution in correlated fluctuations from snapshot small-angle x-ray scattering

It has been suggested that the three-dimensional structure of one particle may be reconstructed using the scattering from many identical, randomly oriented copies ab initio, without modeling or a priori information. This may be possible if these particles are frozen in either space or time, so that the conventional two-dimensional small-angle x-ray scattering (SAXS) distribution contains fluctuations and is no longer isotropic. We consider the magnitude of the correlated fluctuation SAXS (CFSAXS) signal for typical x-ray free-electron laser (XFEL) beam conditions and compare this against the errors derived with the inclusion of Poisson photon counting statistics. The resulting signal-to-noise ratio (SNR) is found to rapidly approach a limit independent of the number of particles contributing to each diffraction pattern, so that the addition of more particles to a ''single-particle-per-shot'' experiment may be of little value, apart from reducing solvent background. When the scattering power is significantly less than one photon per particle per Shannon pixel, the SNR grows in proportion to incident flux. We provide simulations for protein molecules in support of these analytical results, and discuss the effects of solvent background scatter. We consider the SNR dependence on resolution and particle size, and discuss the application of the method to glasses and liquids, and the implications of more powerful XFELs, smaller focused beams, and higher pulse repetition rates for this approach. We find that an accurate CFSAXS measurement may be acquired to subnanometer resolution for protein molecules if a 9-keV beam containing 10{sup 13} photons is focused to a {approx}100-nm spot diameter, provided that the effects of solvent background can be reduced sufficiently.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Robust error calibration for serial crystallography

Serial crystallography is an important technique with unique abilities to resolve enzymatic transition states, minimize radiation damage to sensitive metalloenzymes and perform de novo structure determination from micrometre-sized crystals. This technique requires the merging of data from thousands of crystals, making manual identification of errant crystals unfeasible. cctbx.xfel.merge uses filtering to remove problematic data. However, this process is imperfect, and data reduction must be robust to outliers. We add robustness to cctbx.xfel.merge at the step of uncertainty determination for reflection intensities. This step is a critical point for robustness because it is the first step where the data sets are considered as a whole, as opposed to individual lattices. Robustness is conferred by reformulating the error-calibration procedure to have fewer and less stringent statistical assumptions and incorporating the ability to down-weight low-quality lattices. We then apply this method to five macromolecular XFEL data sets and observe the improvements to each. The appropriateness of the intensity uncertainties is demonstrated through internal consistency. This is performed through theoretical CC 1/2 and I /σ relationships and by weighted second moments, which use Wilson's prior to connect intensity uncertainties with their expected distribution. This work presents new mathematical tools to analyze intensity statistics and demonstrates their effectiveness through the often underappreciated process of uncertainty analysis.

Mittan-Moreau, David W.↗

Cross-polarization systematics due to Mizuguchi-Dragone condition breaking by a continuously rotating half-wave plate at prime focus in the Huan Tran telescope

Polarization modulation using a continuously rotating half-wave plate (HWP) is a promising technique to reduce both low-frequency noise and instrumental systematics for Cosmic Microwave Background (CMB) polarization measurements targeting in ationary B-modes. Although a HWP is best placed sky-side of the telescope optics in order to minimize systematics, >0.5 meter aperture class telescopes must put the HWP elsewhere in the optics chain due to current fabrication limitations in the available HWP size. Polarbear is a ground-based CMB experiment installed on the 2.5m aperture off-axis Gregorian-Dragone type Huan Tran Telescope (HTT) designed to satisfy the Mizuguchi-Dragone condition. Polarbear-2 is a receiver that will be installed on a second HTT in 2018. Polarbear-2 is designed to have a larger field-of-view (FOV) and vastly increased sensitivity to the polarized CMB compared to Polarbear. From the third season of observations, Polarbear has installed a continuously rotating HWP at the spatially localized focus plane between the HTT primary and secondary re ectors which is an optimal location for minimizing the HWP diameter. The HWP's polarization angle re ection with respect to its birefringent axis will theoretically break the Mizuguchi-Dragone condition when placed between the two reflectors and increase cross-polarization systematics. In this study, we analyze how the Mizuguchi-Dragone condition is violated due to a HWP at this location. We then estimate the crosspolarization systematics of the HTT using physical optics simulations. We model an ideal HWP at various angles to estimate the effects of demodulation. We evaluate the increased cross-polarization as the Stokes Q-U mixing term using the Mueller Matrix formalism. It is calculated that this term creates a varying dipole beam pattern whose amplitude ranges from 1% at the center to 10% at the edge FOV pixels for Polarbear and potentially up to 20% for Polarbear-2. We also estimate the leakage of the E-mode into the B-mode angular power spectrum measurements due to this cross-polarization. We show that the cross-polarization systematic error leakage is sufficiently lower than the Polarbear-2 statistical uncertainty thanks to mitigations such as focal plane averaging and sky rotation. Currently for Polarbear-2 we are planning to place the HWP at Gregorian focus, but keeping the HWP at prime focus as a back-up solution in case that there are unforeseen telescope spatial and HWP material size constraints. Through this study we find that even though a HWP between the two reflectors will violate the Mizuguchi-Dragone condition, this HWP at prime focus will still have sufficiently low cross-polarization for Polarbear-2. The prime focus HWP is a potential configuration that can be applied to similar off-axis Gregorian-Dragone telescopes in order to minimize the required HWP diameter.

Takakura, Satoru↗

A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery

Purpose: Monoscopic x-ray imaging with on-board kV devices is an attractive approach for real-time image guidance in modern radiation therapy such as VMAT or IMRT, but it falls short in providing reliable information along the direction of imaging x-ray. By effectively taking consideration of projection data at prior times and/or angles through a Bayesian formalism, the authors develop an algorithm for real-time and full 3D tumor localization with a single x-ray imager during treatment delivery. Methods: First, a prior probability density function is constructed using the 2D tumor locations on the projection images acquired during patient setup. Whenever an x-ray image is acquired during the treatment delivery, the corresponding 2D tumor location on the imager is used to update the likelihood function. The unresolved third dimension is obtained by maximizing the posterior probability distribution. The algorithm can also be used in a retrospective fashion when all the projection images during the treatment delivery are used for 3D localization purposes. The algorithm does not involve complex optimization of any model parameter and therefore can be used in a ''plug-and-play'' fashion. The authors validated the algorithm using (1) simulated 3D linear and elliptic motion and (2) 3D tumor motion trajectories of a lung and a pancreas patient reproduced by a physical phantom. Continuous kV images were acquired over a full gantry rotation with the Varian TrueBeam on-board imaging system. Three scenarios were considered: fluoroscopic setup, cone beam CT setup, and retrospective analysis. Results: For the simulation study, the RMS 3D localization error is 1.2 and 2.4 mm for the linear and elliptic motions, respectively. For the phantom experiments, the 3D localization error is < 1 mm on average and < 1.5 mm at 95th percentile in the lung and pancreas cases for all three scenarios. The difference in 3D localization error for different scenarios is small and is not statistically significant. Conclusions: The proposed algorithm eliminates the need for any population based model parameters in monoscopic image guided radiotherapy and allows accurate and real-time 3D tumor localization on current standard LINACs with a single x-ray imager.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Harmonic analysis for the characterization and correction of geometric distortion in MRI

Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset ROIs, respectively. In addition, the fraction of points with a distortion magnitude greater than 1 mm is reduced from 35.6% to 2.8% and from 40.4% to 1.5%, respectively. Similarly, following correction using the reduced-order mapping, the mean distortion magnitude reduces to 0.45–0.42 mm within the central and offset ROIs, and the fraction of points with a distortion magnitude greater than 1 mm is reduced to 2.8% and 1.5%, respectively. Conclusions: A novel harmonic approach to the characterization of system-related distortions in MRI is presented. This method permits a complete and accurate mapping of the DVF within a specified ROI using a limited measurement of the distortion on the ROI boundary. This technique eliminates the requirement to exhaustively sample the DVF at a dense 3D array of points, thereby permitting the design of simple, inexpensive phantoms that may incorporate additional modules for auxiliary quality assurance objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stokhos v 1.0

A Trilinos package for applying stochastic Galerkin uncertainty quantification methods to large-scale C++ application codes, primarily stochastic partial differential equations. Stokhos is intended for use in estimating uncertainties for general scientific computations and is based on published algorithms. It provides no capability for implementing those computations itself. Estimating uncertainties and errors from solution algorithms or simulations, primarily simulations of partial differential equations, arising from uncertainties or errors in solution algorithm or simulation input data, including statistical moments, probabilities, and coefficients of variation.

Source record↗

CV4Quantum

CV4Quantum is a statistical technique for reducing the sampling overhead in probabilistic error cancellation, which is an error mitigation technique used in quantum computing. CV4Quantum is based on the control variates method, which is a Monte Carlo variance reduction technique. This repository contains the code and data associated with a demonstration of CV4Quantum using simulation experiments.

Shyamsundar, Prasanth [Fermi National Accelerator ↗

Data Assimilation - Advances and Applications

This presentation provides an overview of data assimilation (model calibration) for complex computer experiments. Calibration refers to the process of probabilistically constraining uncertain physics/engineering model inputs to be consistent with observed experimental data. An initial probability distribution for these parameters is updated using the experimental information. Utilization of surrogate models and empirical adjustment for model form error in code calibration form the basis for the statistical methodology considered. The role of probabilistic code calibration in supporting code validation is discussed. Incorporation of model form uncertainty in rigorous uncertainty quantification (UQ) analyses is also addressed. Design criteria used within a batch sequential design algorithm are introduced for efficiently achieving predictive maturity and improved code calibration. Predictive maturity refers to obtaining stable predictive inference with calibrated computer codes. These approaches allow for augmentation of initial experiment designs for collecting new physical data. A standard framework for data assimilation is presented and techniques for updating the posterior distribution of the state variables based on particle filtering and the ensemble Kalman filter are introduced.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Scalable, In-situ Data Clustering Data Analysis for Extreme Scale Scientific Computing (Final Report)

The objective of this project is to address challenges in the design and development of scalable in-situ data clustering and analytics algorithms and software. Our goal is to develop parallel software consisting of a set of spatio-temporal data clustering and anomaly detection functions, both of which are very important for large-scale analysis and have wide applicability for in-situ runs as well as post-processing analysis. Our design principles for in-situ analysis consider the following: (1) identify parts of the computation can be done close to the data within the nodes, while it is still in memory; (2) extract analysis components can (and should) be performed in remote staging and analysis nodes; (3) develop error-bound approximation methods for applications tolerable for small errors; (4) identify the type of derived distributions and statistics, for spatio-temporal data, that can be kept locally in order to both accelerate computations and meet energy constraints in subsequent iterations and phases; (5) use a self-describing data format so that data can be consistent and understood among local storage (memory and SSDs) and at staging and analysis nodes, thereby providing portability and flexibility; (6) develop service-oriented functions that can schedule in-situ and post-hoc analysis tasks based on the dynamic requirements of applications. Our development focus is to produce the parallel data analysis software/library that will be scalable, reusable, extensible, and generic for applications in different disciplines. The software will be able to run in-situ with the simulations as well as post-hoc analysis. This approach will satisfy many synergistic requirements for data intensive applications executed on data coming from instruments and experiments. In particular, the proposed multilevel approach is directly applicable to perform design tradeoffs for running part of the algorithms near the instruments and the rest on remote (analysis) systems.

97 MATHEMATICS AND COMPUTING↗