Search NASA⌕ Search

SEARCH · Search NASA

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Distributed Sapphire Fiber Bragg Gratings Based Thermal Profiling of Submerged Entry Nozzles

This research focuses on the application of sapphire fiber Bragg gratings (FBGs) for instrumentation in submerged entry nozzles (SEN) within the steelmaking industry. The SEN is pivotal for transferring molten steel from a tundish to a mold, while preventing the infiltration of oxygen and nitrogen from the surrounding environment. Maintaining optimal flow conditions in the mold is crucial for ensuring casting process stability and maintaining high quality steel. Sapphire FBG sensors have been instrumented in SENs to enable distributed thermal mapping for monitoring the health of the SEN. The optical sensor comprises three cascaded sapphire FBGs inscribed using femtosecond laser technology into a one-meter-long sapphire crystalline fiber. The sensor underwent characterization in a laboratory setting up to 1600°C and was tested for long-term stability over 40 hours under extreme environmental conditions. The coupling between silica and sapphire fibers was investigated and implemented during sensor packaging. Here, the sensor successfully captured the pre-heat sequence of the SEN in real-world steelmaking operations. Compared to conventional thermocouples, sapphire FBG sensors demonstrated exceptional efficiency and precision. They offer potential benefits such as increased productivity, reduced energy consumption, and minimized carbon footprint in the steel industry.

Sapphire Fiber Bragg Grating↗

Ultrasonic Measurements of Temperature Distribution and Heat Fluxes Across Containments of Extreme Environments

Extreme conditions are common in energy conversion, material processing, nuclear, airspace, and military applications. In such environments, the most hardened insertion sensors do not perform reliably for long. Ultrasonic measurements, on the other hand, can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable in the cases when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. The delays between the echoes, which encode the information on the temperature distribution in the corresponding segments, is used to reconstruct unknown temperature profile. In this paper, we outline the results of pilot-scale testing of the developed approach and demonstrate its application to the measurements of the temperature distribution across the containment of a high-temperature combustion process. The validation results show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Jia, Yunlu↗

Effect of cold cap coverage and emissivity on the plenum temperature in a pilot-scale waste vitrification melter

Integrated computational fluid dynamics (CFD) models are being developed to model the complex physics occurring within the high-level waste melter for vitrification of legacy tank waste at the Hanford site. Here, we present a validation of the integrated CFD model by using data from two experimental runs in a pilot-scale melter. While the model uses several simplifying assumptions (such as constant heat sinks from a cooling jacket and inleakage of ambient air, steady state feed-to-batch conversion heat, and a cold cap model with a simplified shape), it closely predicts the molten glass (1150°C and 1175°C) and plenum temperatures (550°C) obtained from thermocouples during two pilot-scale tests, with an average cold cap coverage of 80%. Additional simulations were performed to explore the sensitivity of the predicted plenum temperatures to variations in cold cap coverage (fraction of melt surface covered by the glass batch) and batch emissivity. The plenum temperature was found to be in the range of 606°C when cold cap coverage decreased from 95% to 70%. Cold cap emissivity had a smaller effect, increasing the plenum temperature by as much as 179°C when cold cap emissivity increased from 0.2 to 0.8. Maintaining a high cold cap coverage without overfeeding is important for a sustained melter operation with high glass throughput. This work provides a tool for achieving that goal in terms of correlating the plenum temperature with the cold cap coverage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Determination of temperature-dependent heat conductivity and thermal diffusivity of waste glass melter feed

The cold cap is a layer of reacting glass batch floating on the surface of melt in an all-electric continuous glass melter. The heat needed for the conversion of the melter feed to molten glass must be transferred to and through the cold cap. Since the heat flux into the cold cap determines the rate of melting, the heat conductivity is a key property of the reacting feed. We designed an experimental setup consisting of a large cylindrical crucible with an assembly of thermocouples that monitors the evolution of the temperature field while the crucible is heated at a constant rate. Then we used two methods to calculate the heat conductivity and thermal diffusivity of the reacting feed: the approximation of the temperature field by polynomial functions and the finite-volume method coupled with least-squares analysis. Up to 680°C, the heat conductivity of the reacting melter feed was represented by a linear function of temperature.

Pokorny, Richard↗

Determination of heat conductivity and thermal diffusivity of waste glass melter feed: Extension to high temperatures

The heat conductivity ({lambda}) and the thermal diffusivity (a) of reacting glass batch, or melter feed, control the heat flux into and within the cold cap, a layer of reacting material floating on the pool of molten glass in an all-electric continuous waste glass melter. After previously estimating {lambda} of melter feed at temperatures up to 680 deg C, we focus in this work on the {lambda}(T) function at T > 680 deg C, at which the feed material becomes foamy. We used a customized experimental setup consisting of a large cylindrical crucible with an assembly of thermocouples, which monitored the evolution of the temperature field while the crucible with feed was heated at a constant rate from room temperature up to 1100°C. Approximating measured temperature profiles by polynomial functions, we used the heat transfer equation to estimate the {lambda}(T) approximation function, which we subsequently optimized using the finite-volume method combined with least-squares analysis. The heat conductivity increased as the temperature increased until the feed began to expand into foam, at which point the conductivity dropped. It began to increase again as the foam turned into a bubble-free glass melt. We discuss the implications of this behavior for the mathematical modeling of the cold cap.

36 MATERIALS SCIENCE↗

Design, Development, and Operation of an Integrated Fluidized Carbon Capture Unit Using Polyethylenimine Sorbents

In this paper, we present the design, development, and operation of a reactor system for CO 2 capture. Modifications were implemented to address differences in sorbent from 180 μm Geldart group B to 115 μm Geldart group A material; operational issues were discovered during experimental trials. The major obstacle in system operation was the ability to maintain a constant circulation of a solid sorbent stemming from this change in sorbent material. The system consisted of four fluid beds, through which a polyamine impregnated sorbent was circulated and adsorption, preheat, regeneration, and cooling processes occurred. Pressure transducers, thermocouples, gas flow meters, and gas composition instrumentation were used to characterize thermal, hydrodynamic, and gas adsorption performance in this integrated unit. A series of shakedown tests were performed and the configuration altered to meet the needs of the sorbent performance and achieve desired target capture efficiencies. Methods were identified, tested, and applied to continuously monitor critical operating parameters including solids circulation rate, adsorbed and desorbed CO 2 , solids inventories, and pressures. The working capacity and CO 2 capture efficiency were used to assess sorbent performance while CO 2 closure was used to define data quality and approach to steady-state. Testing demonstrated >90% capture efficiencies and identified the regenerator to be the process step limiting throughput. Sorbent performance was found to be related to the reactant stoichiometry. Finally, a stochastic model with an exponential dependence on the relative CO 2 /amine concentration was used to describe 90% of the variance in the data.

01 COAL, LIGNITE, AND PEAT↗

Module-Level Thermal Interface Material Degradation in HALT

Abstract In this study, thermal interface material (TIM) degradation is driven through highly accelerated life test (HALT) using temperature cycling with a prescribed vibrational acceleration for two commercially available materials having thermal conductivities of 6.0 and 8.5 W/m K. HALT specimens were prepared by applying TIM through a 4-mil stencil over AlSiC baseplates in the shape of those used in Wolfspeed CAS325M12HM2 power electronics modules. Baseplates were mounted onto aluminum carrier blocks with embedded thermocouples to characterize the thermal resistance across the baseplate and TIM layer. Thermal dissipation into the top of the baseplates was provided by a custom heating block, which mimics the size and placement of the die junctions in CAS325 modules, applying power loads of 200, 300, and 400 W. After initial characterization, samples were transferred to the HALT chamber with one set of samples exposed to temperature cycling only (TCO) and the other temperature cycling and vibration (TCV). Both sample sets were cycled between temperature extremes of −40 °C and 180 °C with vibrations applied at a peak acceleration of 3.21 Grms. After hundreds of cycles, samples were reevaluated to assess changes in thermal resistance to provide an accelerated measure of TIM degradation. This allows for reliability prediction of useful lifetime (illustrated in a solar inverter case study herein), as well as to provide a basis for developing an accelerated testing method to related temperature cycling to faster methods of degradation. Such techniques provide a means to develop maintenance schedules for power modules for ensuring sufficient thermal performance over the operating lifetime.

Engineering↗

Experimental and Computational Heat Transfer Study of sCO 2 Single-Jet Impingement

This study experimentally and computationally investigates the heat transfer capability of supercritical carbon dioxide (sCO 2 ) single jet impingement. The evaluated jet Reynolds number range is between 80,000 and 600,000, with a nondimensional jet-to-target surface spacing of 2.8. CO 2 -impinging jet stagnation conditions were maintained at approximately 200 bar and a temperature of ∼400 °C for most experiments. The goal is to understand how changes in the aforementioned parameters influence heat transfer between the working fluid and the heated surface. Additionally, due to the elevated Reynolds numbers and difference in thermodynamic properties between air and CO 2 , air-derived impingement correlations may not be appropriate for CO 2 impingement; these correlations will be evaluated against experimental sCO 2 impingement data. At the time of this study, no sCO 2 impingement data was available relevant to sCO 2 power cycles. The target surface is a 1.5-in. diameter copper block centered on the 3 mm jet orifice. A mica heating element bolted to the bottom of the copper block provides a uniform heat flux. Thermocouples embedded in the copper block are used to determine the surface temperature. Nusselt numbers obtained from experimental sCO 2 test data are compared to area-averaged Nusselt numbers from air-derived correlations. The comparisons showed that air correlations drastically underpredict the heat transfer when sCO 2 is used as the working fluid. A modified sCO 2 correlation using experimental data at discussed conditions is derived based on an existing air correlation. A CFD study is also performed to further investigate sCO 2 heat transfer characteristics, and assess the numerical model applicability to this problem type.

42 ENGINEERING↗

Band Heater Heat Flux Characterization Using Inverse Heat Conduction Problem Models

Abstract An experimental apparatus was constructed to correlate water flowrate and temperature rise under an external band heater. Due to the physical characteristics of the band heater, its transient heating behavior is unknown. This paper investigates the application of inverse heat conduction problem (IHCP) methods to characterize the heat flux from the band heater. Three experiments with different heating times (5, 10, and 20 s) and no flowrate were conducted to measure the transient temperature under the 400 W band heater. Type-T thermocouples measure surface temperature at the centerline of the band heater. The experimental results are computed with five different heat conduction models. The models are chosen to identify how the heat flux response varies from a simplified to a realistic model. Additionally, the results of the experimental heat flux are compared to the manufacturer band heater data (58.9 kW/m2) for each model. The minimum time needed for the heater to fully energize the system is from 10 to 12 s. The residuals for each model are analyzed and used to evaluate the appropriateness of the five different models. The results show that the use of simpler models can achieve results similar to those of complex models, with less time and computational cost.

Engineering↗

Experimental Evaluation of Heat Transfer in a High Temperature High Pressure Test Facility

Performance of film cooling holes is generally evaluated near ambient conditions, so scaling the film cooling performance from ambient to engine conditions is important. These performance metrics can be reported in terms of net heat flux reduction, heat transfer enhancement, and effectiveness. There are several challenges and penalties in conducting experiments on a real engine or even on a stationary flat plate test article at near engine conditions. In this study, an experimental methodology capable of delivering film cooling performance for the experiments conducted in the high-temperature high-pressure test facility at NETL will be explored. More specifically, this study focuses on various challenges that are present and how these concerns are addressed to evaluate the heat transfer coefficient on the test article. Steady state experiments were conducted on a flat plate test article whose surface temperature distribution was obtained using an IR camera calibrated with a combination of bench top experiments and in-situ calibrations based on embedded thermocouple measurements. A detailed radiation analysis is conducted to enable differentiation of heat transfer by convection from heat transfer by radiation. The estimated surface heat flux and heat transfer coefficient were found to be higher than the one obtained from flat plate correlation.

Ramesh, Sridharan↗

Calculation of Critical Heat Flux Using an Inverse Heat Transfer Method to Support TREAT Experiment Analysis

Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Welding Process Development for Spent Nuclear Fuel Canister Repair

The potential for stress corrosion cracking (SCC) of welded stainless-steel interim storage containers for spent nuclear fuel (SNF) has been identified as a high priority data gap. This paper presents a fusion welding process that was developed for SNF canister repair. Submerged arc welding (SAW) was developed to weld 12.7 mm (0.5 in.) thick 304L stainless steel plates to simulate the initial welds on SNF canisters. The SAW procedure was qualified following ASME Boiler and Pressure Vessel Code requirements. During SAW, the welding temperature was recorded at various locations by using thermocouples. After SAW, weld microstructures were characterized, joint mechanical properties were tested, and the maximum tensile residual stress direction was identified. After SAW procedure qualification, artificial cracks were excavated perpendicular to the maximum tensile residual stress direction in the SAW heat affected zone. Machine cold-wire gas tungsten arc welding (CW-GTAW) was developed and used for repair welding at cracked locations.

Tang, Wei↗

TRANSIENT THERMAL MODELING OF THE HIGH BURNUP DEMONSTRATION RESEARCH PROJECT CASK USING STAR-CCM+ AND COBRA-SFS

The Department of Energy in collaboration with the Electric Power Research Institute is in the process of conducting the High Burnup Demonstration Project. Where the objective is to characterize the performance of high-burnup fuel in long term storage. As part of this demonstration, a TN-32B dry storage cask was instrumented and loaded with spent nuclear fuel at North Anna Nuclear Generating Station in November 2017. The project cask provides a unique opportunity to gain information on spent fuel and cask performance from an in-service operational system. The cask was instrumented with thermocouples inside of the fuel assemblies, then loaded and dried using normal procedures. After the drying process a thermal soak period where the cask was left indoors was used to obtain steady temperatures for model comparison along with surface temperatures. This paper details thermal modeling validation work that was done to model both the steady state and transient cases. Two modeling tools were used to predict temperatures in the cask. The general purpose CFD and heat transfer code STAR-CCM+ was used with both a detailed pin-by-pin model was used along with a more efficient k-effective simplification. The other code is COBRA-SFS, a purpose-built detailed thermal modeling tool developed and maintained at PNNL. Results from all the modeling tools were compared blind to the test data. Each model utilized general design information and compared reasonably well to the blind steady state data using convection and surface temperature boundary conditions. Post-test adjustments were later made to better reflect the “as built” conditions of the cask. Based on lessons learned from the steady state analysis the vacuum drying process was modeled in both codes. Utilizing the measured loading conditions the transient models were able to compare very well with the measured data. Overall the project showed an ability to model spent fuel storage conditions very well and future work is planned to generalize the methodology used for vacuum drying.

Thermal Analysis, Spent Fuel, Dry Storage↗

JOHNSON NOISE THERMOMETRY FOR DRIFT-FREE MEASUREMENTS

In order for Johnson Noise Thermometry (JNT) to be beneficial to SMR designers, it must offer advantages beyond the current state-of-the-art technology. Comparisons to traditional RTDs and thermocouples will involve life-cycle costs, installation footprint, reliability, and accuracy. With JNT, there is additional equipment beyond what is required for the traditional RTD measurement. Therefore, the JNT-RTD system will involve additional complexity and this additional complexity must be justified. Operators will want to know that the measurement is reliable and trustworthy. It is also important that the sensor involve little, if any, additional ongoing maintenance work and that it has a low probability of causing any malfunction of the primary measurement channel. If these features can be successfully demonstrated, the JNT-RTD system could potentially save money and increase plant reliability.

Britton, Jr, Charles L↗

Polarization effects associated with thermal processing of HY-80 structural steel using high-power laser diode array

Localized heating of roughened steel surfaces using disperse laser light emitted from high power laser diode arrays was experimentally demonstrated and compared with theoretical predictions. The Fresnel equations were used to analyze the optical absorptivity in terms of the angle of incidence and polarization state to understand the laser-induced temperature rise of HY-80 steel plates under 383-612 W laser irradiation. Laser-induced, transient temperature distributions were directly measured using bulk thermocouple probes and thermal imaging. Finite element analysis yielded quantitative assessment of energy deposition and heat transport in HY-80 steel using absorptivity as a tuning parameter. The extracted absorptivity values ranged from 0.62 to 0.75 for S-polarized and 0.63 to 0.85 for P-polarized light, in agreement with partially oxidized iron surfaces. Microstructural analysis using electron backscatter diffraction revealed a heat affected zone for the highest temperature conditions (612 W, P-polarized) as evidence of rapid quenching and an austenite to martensite transformation. In conclusion, the efficient use of diode arrays for laser-assisted advanced manufacturing technologies such as hybrid friction stir welding is discussed.

36 MATERIALS SCIENCE↗

In Situ Measurement of Temperature Distributions in a Li-ion Cell during Internal Short Circuit and Thermal Runaway

Here we report in situ measurement of temperature distributions in a 2.5-Ah pouch format Li-ion cell during internal short circuit (ISC) and thermal runaway. The ISC and thermal runaway were triggered by nail penetration. The local temperatures were measured by embedded K type micro thermocouples in the middle layer of the experimental Li-ion cell. Highly non-uniform temperature distributions were observed during ISC and thermal runaway as compared with those during constant current discharging and external short circuit. The in situ measurement also captured details of how thermal runaway started from the ISC location and spread to the entire cell in a few seconds. Moreover, the comparison between ISC without thermal runaway and ISC with thermal runaway suggests that internal short circuit resistance plays a critical role in the risk of thermal runaway.

Huang, Shan↗

Tracking Internal Temperature and Structural Dynamics during Nail Penetration of Lithium-Ion Cells

Mechanical abuse of lithium-ion batteries is widely used during testing to induce thermal runaway, characterize associated risks, and expose cell and module vulnerabilities. But, the repeatability of puncture or 'nail penetration' tests is a key issue as there is often a high degree of variability in the resulting thermal runaway process. Here, the failure mechanisms of 18650 cells punctured at different locations and orientations are characterized with respect to their internal structural degradation, and both their internal and surface temperature, all of which are monitored in real time. The initiation and propagation of thermal runaway is visualized via high-speed synchrotron X-ray radiography at 2000 frames per second, and the surface and internal temperatures are recorded via infrared imaging and a thermocouple embedded in the tip of the penetrating nail, respectively. The influence of the nail, as well as how and where it penetrates the cell, on the initiation and propagation of thermal runaway is described and the suitability of this test method for representing in-field failures is discussed.

25 ENERGY STORAGE↗

sCO2 heat exchanger control software

SAND2022-6992 O The sCO2 Heat Exchanger Control Software was written for control and operation of high temperature, high pressure supercritical CO2 systems designed for use as heat exchangers. The software was written using the basic LabVIEW package with LabVIEW modules added to it. The software controls valves and actuators, displays data from pressure transducers and thermocouples, and is able to record data at different storage rates. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Garcia Maldonado, Luis↗