Search NASA⌕ Search

SEARCH · Search NASA

Results for “Temperature Design Methodology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Air Dispersion Modeling for the INL Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emission Cap Component

The Department of Energy Idaho Operations Office (DOE-ID) is applying for a synthetic minor, Sitewide, air quality permit to construct (PTC) with a facility emission cap (FEC) component from the Idaho Department of Environmental Quality (DEQ) for Idaho National Laboratory (INL) to limit its potential to emit to less than major facility limits for criteria air pollutants (CAPs) and hazardous air pollutants (HAPs) regulated under the Clean Air Act. This document is supplied as an appendix to the application, Idaho National Laboratory Application for a Synthetic Minor Sitewide Air Quality Permit to Construct with a Facility Emissions Cap Component, hereafter referred to as “permit application” (DOE-ID 2015). Air dispersion modeling was performed as part of the permit application process to demonstrate pollutant emissions from the INL will not cause a violation of any ambient air quality standards. This report documents the modeling methodology and results for the air dispersion impact analysis. All CAPs regulated under Section 109 of the Clean Air Act were modeled with the exception of lead (Pb) and ozone, which are not required to be modeled by DEQ. Modeling was not performed for toxic air pollutants (TAPs) as uncontrolled emissions did not exceed screening emission levels for carcinogenic and non-carcinogenic TAPs. Modeling for CAPs was performed with the EPA approved AERMOD dispersion modeling system (Version 14134) (EPA 2004a) and five years (2000-2004) of meteorological data. The meteorological data set was produced with the companion AERMET model (Version 14134) (EPA 2004b) using surface data from the Idaho Falls airport, and upper-air data from Boise International Airport supplied by DEQ. Onsite meteorological data from the Grid 3 Mesonet tower located near the center of the INL (north of INTEC) and supplied by the local National Oceanic and Atmospheric Administration (NOAA) office was used for surface wind directions and wind speeds. Surface data (i.e., land use data that defines roughness, albedo, Bowen ratio, and other parameters) were processed using the AERSURFACE utility (Version 13016) (EPA 2013). Emission sources were modeled as point sources using actual stack locations and dimensions. Emissions, flow rates and exit temperatures were based on the design operating capacity of each source. All structures close enough to produce an area of wake effect were included for all sources. For multi-tiered structures, the heights of the tiers were included or the entire building height was assumed to be equal to the height of the tallest tier. Concentrations were calculated at 1,352 receptor locations provided by DEQ. All receptors were considered for each pollutant and averaging period. Maximum modeled CAP concentrations summed with average background concentration values were presented and compared to National Ambient Air Quality Standards (NAAQS). The background concentration values used were obtained using the Washington State University’s Laboratory for Atmospheric Research North West Airquest web-based retrieval tool (http://lar.wsu.edu/nw airquest/lookup.html). The air dispersion modeling results show the maximum impacts for CAPs are less than applicable standards and demonstrate the INL will not cause a violation of any ambient air quality standards.

54 ENVIRONMENTAL SCIENCES↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Personal thermal management using portable thermoelectrics for potential building energy saving

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 degrees C (70 degrees F) and 23.9 degrees C (75 degrees F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid and Parallel Domain-Decomposition Methods Development to Enable Monte Carlo for Reactor Analyses

This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform real commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the gold standard for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method, which attempts to achieve uniform statistical uncertainty throughout a designated problem space. The MC DD development is being implemented in conjunction with the Denovo deterministic radiation transport package to have direct access to the 3-D, massively parallel discrete-ordinates solver (to support the hybrid method) and the associated parallel routines and structure. This paper describes the hybrid method, its implementation, and initial testing results for a realistic 2-D quarter core pressurized-water reactor model and also describes the MC DD algorithm and its implementation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An extrapolation method for strain ranges and hold times in developing the EPP+SMT creep-fatigue design curves for Alloy 617

Experimental and numerical studies in developing the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY2022. This report focuses on the methods for extrapolating the EPP+SMT creep-fatigue (CF) design curves at long hold times and low strain ranges. In this study, the available CF failure data on Alloy 617 at 950°C were analyzed to determine a set of CF failure criteria. At very low strain ranges and long hold times, CF failure data are not accessible by experiments because of the extraordinarily long test durations and the inability of the test machines to accurately control these small strain ranges. A CF experimental approach with the concept of block-strain range CF testing protocol was developed. Tests using this protocol were conducted to generate the needed information for calibrating material parameters of the numerical material models. The Time Fraction based method and Dissipated Energy method were used to extrapolate the CF life curves to low strain ranges and long hold times. Based on the new experimental approach and CF life prediction methods, the CF life curves with various hold times were developed for Alloy 617 at 950°C. In addition, an experiment was designed and is being performed to verify the predicted CF curves at 950°C. The extrapolation procedure will be applied at lower temperatures to complete the development of the EPP+SMT CF design curves for Alloy 617 in F2023.

36 MATERIALS SCIENCE↗

Hybrid and Parallel Domain-Decomposition Methods Development to Enable Monte Carlo for Reactor Analyses

This paper describes code and methods development at the Oak Ridge National Laboratory focused on enabling high-fidelity, large-scale reactor analyses with Monte Carlo (MC). Current state-of-the-art tools and methods used to perform ''real'' commercial reactor analyses have several undesirable features, the most significant of which is the non-rigorous spatial decomposition scheme. Monte Carlo methods, which allow detailed and accurate modeling of the full geometry and are considered the ''gold standard'' for radiation transport solutions, are playing an ever-increasing role in correcting and/or verifying the deterministic, multi-level spatial decomposition methodology in current practice. However, the prohibitive computational requirements associated with obtaining fully converged, system-wide solutions restrict the role of MC to benchmarking deterministic results at a limited number of state-points for a limited number of relevant quantities. The goal of this research is to change this paradigm by enabling direct use of MC for full-core reactor analyses. The most significant of the many technical challenges that must be overcome are the slow, non-uniform convergence of system-wide MC estimates and the memory requirements associated with detailed solutions throughout a reactor (problems involving hundreds of millions of different material and tally regions due to fuel irradiation, temperature distributions, and the needs associated with multi-physics code coupling). To address these challenges, our research has focused on the development and implementation of (1) a novel hybrid deterministic/MC method for determining high-precision fluxes throughout the problem space in k-eigenvalue problems and (2) an efficient MC domain-decomposition (DD) algorithm that partitions the problem phase space onto multiple processors for massively parallel systems, with statistical uncertainty estimation. The hybrid method development is based on an extension of the FW-CADIS method, which attempts to achieve uniform statistical uncertainty throughout a designated problem space. The MC DD development is being implemented in conjunction with the Denovo deterministic radiation transport package to have direct access to the 3-D, massively parallel discrete-ordinates solver (to support the hybrid method) and the associated parallel routines and structure. This paper describes the hybrid method, its implementation, and initial testing results for a realistic 2-D quarter core pressurized-water reactor model and also describes the MC DD algorithm and its implementation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MACS, An Instrument, and a Methodology for Simulations and Global Measurements of the Coronal Electron Temperature and the Solar Wind Velocity on the Solar Corona

The determination of the radial and latitudinal temperature and wind profiles of the solar corona is of great importance in understanding the coronal heating mechanism and the dynamics of coronal expansion. Cram presented the theory for the formation of the K-coronal spectrum and identified two important observations. He observed the existence of temperature sensitive anti-nodes at certain wavelengths in the theoretical K-coronal spectra. The anti-nodes are separated by temperature-insensitive nodes. Remarkably, Cram showed that the wavelengths of the nodes and anti-nodes are almost independent of altitude above the solar limb. Because of these features, Cram suggested that the intensity ratios at two anti-nodes could be used as a diagnostic of the electron temperature in the K-corona. Based on this temperature diagnostic technique prescribed by Cram a slit-based spectroscopic study was performed by Ichimoto et al. on the solar corona in conjunction with the total solar eclipse of 3 Nov 1994 in Putre, Chile to determine the temperature profile of the solar corona. In this thesis Cram's theory has been extended to incorporate the role of the solar wind in the formation of the K-corona, and we have identified both temperature and wind sensitive intensity ratios. The instrument, MACS, for Multi Aperture Coronal Spectrometer, a fiber optic based spectrograph, was designed for global and simultaneous measurement of the thermal electron temperature and the solar wind velocity in the solar corona. The first ever experiment of this nature was conducted in conjunction with the total solar eclipse of 11 Aug 1999 in Elazig, Turkey. In this instrument one end of each of twenty fiber optic tips were positioned in the focal plane of the telescope in such a way that we could observe conditions simultaneously at many different latitudes and two different radial distances in the solar corona. The other ends of the fibers were vertically aligned and placed at the primary focus of the collimating lens of the spectrograph to obtain simultaneous and global spectra on the solar corona. By isolating the K-coronal spectrum from the spectrum recorded by each fiber the temperature and the wind sensitive intensity ratios were calculated to obtain simultaneous and global measurements of the thermal electron temperature and the solar wind velocity. We were successful in obtaining reliable estimates of the coronal temperature at many positions in the corona. This is the first time that simultaneous measurements of coronal temperatures have been obtained at so many points. However due to instrumental scattering encountered during observations, reliable estimates of the wind velocity turned out to be impossible to obtain. Although remedial measures were taken prior to observation, this task proved to be difficult owing to the inability to replicate the conditions expected during an eclipse in the laboratory. The full extent of the instrumental scattering was apparent only when we analyzed the observational sequence. Nevertheless the experience obtained from this very first attempt to simultaneously and globally measure both the wind velocity and the temperature on the solar corona have provided valuable information to conduct any future observations successfully.

Reginald, Nelson L.↗

Development and application of two-step uncertainty propagation and sensitivity analysis methodology for fast reactor safety analysis

Uncertainty quantification (UQ) in nuclear reactors for transients is directly linked with safety assessment through the cross-sections uncertainties, provided as a covariance matrix, which are propagated through the reactor system to output of interest pertaining to reactor safety, such as peak temperatures in fuel/clad/coolant. Using a two-step approach, uncertainties are first quantified and propagated from basic input variables (such as reaction cross-sections) to intermediate quantities (such as reactivity feedback coefficients) through lattice level calculations. Uncertainties of intermediate quantities (from the first step) are then propagated through the system transient calculations, in the second step, to obtain uncertainties on reactor safety output parameters of interest. The scope of this work consists of Uncertainty Quantification & Propagation of nuclear data uncertainties that are highly correlated through unprotected transient overpower and unprotected loss of flow to assess their impact on core safety parameters. This two-step approach in the presence of covariance renders the sensitivity analysis very challenging. In fact, usually the sensitivity analysis is restricted to each step, which limits its application since the sensitivities between the system output quantities and the basic input variables are difficult to obtain. Here, in this work, we address this issue by proposing a simple, general methodology to combine the sensitivity indices obtained in each step by assuming the model behavior being linear. For the first step Generalized Perturbation theory based indices are used while in the second step the recently studied Johnson indices. The uncertainty quantification and sensitivity methodologies discussed here are demonstrated on a generic LFR design which is based on the 500 MWth demonstration Lead-cooled fast reactor (DLFR) using oxide fuel, developed by Westinghouse Electric Company (WEC).

42 - ENGINEERING↗

A comparison of trenched plot techniques for partitioning soil respiration

Partitioning the soil surface CO{sub 2} flux (R{sub S}) flux is an important step in understanding ecosystem-level carbon cycling, given that R{sub S} is poorly constrained and its source components may have different responses to climate change. Trenched plots are a classic method of separating the R{sub S} source fluxes, but labor-intensive and may cause considerable disturbance to the soil environment. This study tested if various methods of plant suppression in trenched plots affected R{sub S} fluxes, quantified the R{sub S} response to soil temperature and moisture changes, and estimated the heterotrophic contribution to R{sub S}. It was performed in a boreal black spruce (Picea mariana) plantation, using a complete randomized design, during the 2007 growing season (May-November). Trenched plots had significantly lower R{sub S} than control plots, with differences appearing {approx}100 days after trenching; spatial variability doubled after trenching but then declined throughout the experiment. Most trenching treatments had significantly lower (by {approx}0.5 {mu}mol m{sup -2} s{sup -1}) R{sub S} than the controls, and there was no significant difference in R{sub S} among the various trenching treatments. Soil temperature at 2 cm explained more R{sub S} variability than did 10-cm temperature or soil moisture. Temperature sensitivity (Q10) declined in the control plots from {approx}2.6 (at 5 C) to {approx}1.6 (at 15 C); trenched plots values were higher, from 3.1 at 5 C to 1.9 at 15 C. We estimated R{sub S} for the study period to be 241 {+-} 40 g C m{sup -2}, with roots contributing 64% of R{sub S} after accounting for fine root decay, and 293 g C m{sup -2} for the entire year. These findings suggest that laborious hand weeding of vegetation may be usefully replaced by other methods, easing future studies of this large and poorly-understood carbon flux.

54 ENVIRONMENTAL SCIENCES↗

SOAREX-8 Suborbital Experiments 2015 - A New Paradigm for Small Spacecraft Communication

In 2015 NASA plans to launch a payload to 280 Km altitude on a sounding rocket from the Wallops Flight Facility. This payload will contain several novel technologies that work together to demonstrate methodologies for space sample return missions and for nanosatellite communications in general. The payload will deploy and test an Exo-Brake, which slows the payload aerodynamically, providing eventual de-orbit and recovery of future ISS samples through a Small Payload Quick Return project. In addition, this flight addresses future Mars mission entry technology, space-to-space communications using the Iridium Short Messaging Service (SMS), GPS tracking, and wireless sensors using the ZigBee protocol. SOAREX-8 is being assembled and tested at Ames Research Center (ARC) and the NASA Engineering and Safety Center (NESC) is funding sensor and communications work. Open source Arduino technology and software are used for system control. The ZigBee modules used are XBee units that connect analog sensors for temperature, air pressure and acceleration measurement wirelessly to the payload telemetry system. Our team is developing methods for power distribution and module mounting, along with software for sensor integration, data assembly and downlink. We have demonstrated relaying telemetry to the ground using the Iridium satellite constellation on a previous flight, but the upcoming flight will be the first time we integrate useful flight test data from a ZigBee wireless sensor network. Wireless sensor data will measure the aerodynamic efficacy of the Exo-Brake permitting further on orbit flight tests of improved designs. The Exo-Brake is 5 sq m in area and will be stored in a container and deployed during ascent once the payload is jettisoned from the launch vehicle. We intend to further refine the hardware and continue testing on balloon launches, future sounding rocket flights and on nanosatellite missions. The use of standards-based and open source hardware/software has allowed for this project to be completed with a very modest budget and a challenging schedule. There is a wealth of hardware and software available for both the Arduino platform and the XBee, all low-cost or open-source. Along with the Exo-Brake hardware and deployment discussion, this paper will describe in detail the system architecture emphasizing the successful use of open source hardware and software to minimize effort and cost. Testing procedures, radio frequency interference (RFI) mitigation, success criteria and expected results will also be discussed. The use of Iridium short messaging capability for space-to-space links, standards-based wireless sensor networks, and other innovative communications technology are also presented.

aerobrake↗

ORNL Evaluation of Electrabel Safety Cases for Doel 3 / Tihange 2: Final Report

Oak Ridge National Laboratory (ORNL) performed a detailed technical review of the 2015 Electrabel (EBL) Safety Cases prepared for the Belgium reactor pressure vessels (RPVs) at Doel 3 and Tihange 2 (D3/T2). The Federal Agency for Nuclear Control (FANC) in Belgium commissioned ORNL to provide a thorough assessment of the existing safety margins against cracking of the RPVs due to the presence of almost laminar flaws found in each RPV. Initial efforts focused on surveying relevant literature that provided necessary background knowledge on the issues related to the quasilaminar flaws observed in D3/T2 reactors. Next, ORNL proceeded to develop an independent quantitative assessment of the entire flaw population in the two Belgian reactors according to the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section XI, Appendix G, Fracture Toughness Criteria for Protection Against Failure, New York (1992 and 2004). That screening assessment of all EBL-characterized flaws in D3/T2 used ORNL tools, methodologies, and the ASME Code Case N-848, Alternative Characterization Rules for QuasiLaminar Flaws . Results and conclusions from the ORNL flaw acceptance assessments of D3/T2 were compared with those from the 2015 EBL Safety Cases. Specific findings of the ORNL evaluation of that part of the EBL structural integrity assessment focusing on stability of the flaw population subjected to primary design transients include the following: ORNL s analysis results were similar to those of EBL in that very few characterized flaws were found not compliant with the ASME (1992) acceptance criterion. ORNL s application of the more recent ASME Section XI (2004) produced only four noncompliant flaws, all due to LOCAs. The finding of a greater number of non-compliant flaws in the EBL screening assessment is due principally to a significantly more restrictive (conservative) criterion for flaw size acceptance used by EBL. ORNL s screening assessment results (obtained using an analysis methodology different from that of EBL) are interpreted herein as confirming the EBL screening results for D3/T2. ORNL s independent refined analysis demonstrated the EBL-characterized flaw 1660, which is non-compliant in the ORNL and EBL screening assessment, is rendered compliant when modeled as a more realistic individual quasi-laminar flaw using a 3-D XFEM analysis approach. ORNL s and EBL s refined analyses are in good agreement for the flaw 1660 close to the clad/base metal interface; ORNL is not persuaded that repeating this exercise for more than one non-compliant flaw is necessary to accept the EBL conclusions derived from the aggregate of EBL refined analysis results. ORNL General Conclusions Regarding the Structural Integrity Assessment (SIA) Conducted by EBL for D3/T2 Based on comparative evaluations of ORNL and EBL SIA analyses and on consideration of other results, ORNL is in agreement with the general conclusions reported by Electrabel in their RPV D3/T2 Technical Summary Note of April 14, 2015: More than 99 percent of flaws in D3/T2 meet the defined screening criterion, rendering them benign with respect to initiation in the event of a design transient. Refined analyses of non-compliant flaws from the screening assessment indicate that only 11 of the 16196 detected flaws have a critical reference-temperature material index (designated RTNDT) that implies the possibility of the initiation of cleavage fracture at some future time. For those 11 2 flaws, the calculated margin in RTNDT (a measure of acceptable embrittlement relative to end-ofservice-life conditions) is significant, being greater than 80 C. Fatigue crack growth is not a concern in the flaw-acceptability analyses. Primary stress re-evaluation confirms that the collapse pressure is more than 1.5 times the design pressure in the presence of defects detected in D3/T2. Sufficient conservatisms are built into the input data and into the different steps of the SIA; in some cases, those conservatisms are quantified and imply that additional margins exist in the SIA. Taken as a whole, the foregoing results and conclusions confirm the structural integrity of Doel 3 and Tihange 2 under all design transients with ample margin in the presence of the 16196 detected flaws.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel Tube Design for Superheater Heat Exchanger Enabled Via Additive Manufacturing

Superheater tubes are critical boiler components that operate at relatively higher temperatures and pressure. Amongst the primary concerns for these tubes is the deposition of ash particles on the tube surface, leading to the reduced thickness of the tube due to material corrosion, consequently causing early creep failure of the component. In this research, a novel tube design has been proposed which resembles a teardrop or ogive shape to reduce the drag and concurrently improve the creep life of the superheater tubes. To administer the practicality of novel tubes, metal additive manufacturing (AM), for instance, laser-powder bed fusion (L-PBF), has been proposed. These unconventional designs were assessed and compared with the baseline circular tube design for mechanical design requirements (hoop stress and creep life) and the particle and flue gas flow characteristics around the differently shaped tubes. A thermomechanical finite element (FE) analysis was performed for hoop stress calculations. This study also emphasizes on effect of circumferential thermal variation on hoop stress distribution in tubes. Therefore, a detailed two-dimensional (2D) thermal simulation has been performed to report the circumferential thermal variation on the tube. A computational fluid dynamics (CFD) analysis coupled with particle tracing was performed for gas flow visualization and particle tracing around the proposed shapes and baseline circular-shaped tube design. The Schlieren optic setup was built and leveraged for qualitative validation of the proposed design. The complete design methodology established in the paper shows teardrop-shaped tubes better in terms of drag and creep life in contrast to the circular-shaped tube.

42 ENGINEERING↗

An Accurate Fast Fluid Dynamics Model for Data Center Applications

Traditional CFD is broadly useful in the design and operation of reliable and efficient data centers. It is nevertheless computationally expensive, particularly when employed for design optimization, which usually requires multiple simulations. To speed-up calculations while retaining essential airflow physics, several researchers have turned to an alternative CFD methodology, namely, fast fluid dynamics (FFD). FFD has been reported to be much faster than traditional CFD, but at an assumed (acceptable) trade-off of reduced accuracy. However, a recent comparison of FFD and traditional CFD for data center plenum applications produced nearly indistinguishable results and suggested that previously-reported FFD/traditional-CFD differences were due primarily to inconsistent: 1) advection schemes, 2) computational grids, and 3) turbulence models. The present paper extends this FFD/traditional-CFD comparison to the data center whitespace and confirms the finding that a true like-for-like comparison produces nearly identical predictions. Our FFD implementation utilizes a first-order upwind finite-volume scheme for advection like traditional CFD, so alternative advection schemes (e.g., semi-Lagrangian) are not considered further here. Likewise, the effect of grid choice on traditional-CFD predictions is well known. However, the effect of turbulence model for data center applications has not been reported extensively so we do consider this topic further here. We compare the standard k-e and a simpler algebraic model to benchmark experimental data from a real data center. We find that the algebraic turbulence model predicts rack-inlet temperatures at a similar level-of-accuracy as the k-e model for our fairly-simple-airflow reference data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerothermodynamic Measurements in Hypersonic Non-Equilibrium Flows

High enthalpy arc-jets are unique facilities particularly suited for simulating complex flows in the aerospace field, such as the aerothermodynamics of a re-entry vehicle. Arc-jets are often used to evaluate important design factors such as heat shield materials and vehicle design. Characterization of these facilities is important, as studies often match specific in-flight environments during experiments. Due to the complex environment produced by an arc-jet, with effects such as thermodynamic and chemical non-equilibrium occurring in the flow, characterization experiments are significantly more difficult than in traditional blow-down wind tunnels. The current work aims to characterize an arc-jet facility in terms of flow temperature, velocity and unsteadiness, in a spatially-resolved analysis. To achieve this goal, a non-intrusive imaging technique called “planar laser-induced fluorescence” was performed in the NASA Langley Hypersonic Materials Environ-mental Test System arc-jet facility. The experimental data was analyzed to produce the quantitative measurements in multiple regions of the flow around a blunt body sample. A quasi-1D low fidelity solver was created to numerically simulate the flow to investigate non-equilibrium effects occur-ring outside the imaging region in the arc-jet nozzle. Unsteadiness in the test section was minimized by analyzing a subset of data assessing the gas injection location. Radial velocity, rotational temperature and translational temperature measurements are provided that can be used to validate future high-fidelity computational studies. The temperature measurements revealed rotational non-equilibrium potentially occurring in the flow. This work provides a methodology for characterizing arc-jet facilities, identifying and correcting sources of systematic error, and estimating the uncertainty associated with the quantitative measurements.

laser induced fluorescence↗

Design of a neutral thermal scattering (NeTS) module for hydrogen in light water

The accurate representation of thermal scattering law (TSL) data is integral to the design and characterization of many modern nuclear systems, particularly those using light water as a moderator/coolant. As a material-dependent distribution over energy-momentum phase space, the TSL may exhibit a variety of unique and relevant conditional (e.g., temperature, pressure) and compositional (e.g., porosity, stoichiometry, radiation damage) dependencies. Currently, there are various approaches to incorporate temperature dependence, which is especially important in coupled neutronic-thermal hydraulic simulations. In each approach, there is an inherent tradeoff between memory consumption and accuracy. Some techniques require tens to hundreds of MBs or more, while others fail to reproduce the underlying data to within 10% error over the considered input domain, despite having a reduced storage burden. This work aims to address both sides of the tradeoff simultaneously by implementing a novel deep learning (DL) approach to TSL representation. The neural thermal scattering (NeTS) concept, which is amenable to an arbitrary number of dependencies, is demonstrated via the inclusion of temperature dependence into a highly compact, highly accurate functional form of the multi- variate TSL (i.e., S(α, β, T)) for hydrogen in light water. Resulting storage requirements are on the order of 100 kB, and median and maximum percent deviations are on the order of 0.1% and 1%, respectively. These measures represent a step improvement over previous techniques. Notably, the developed neural network and feature methodology build on those employed in prior work on beryllium oxide. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of the Fast and Thermal Neutron Flux Profiles in the Advanced Test Reactor for the AGR-3/4 Experiment

The AGR-3/4 experiment was designed to irradiate TRISO particle fuel in the Advanced Test Reactor (ATR) at the Idaho National Laboratory. Temperature control of the test capsules containing the TRISO particles was important since the goal was to measure diffusion rates of fission product elements through graphite as a function of temperature. During the experiment, differences were observed between temperatures measured by the thermocouples and temperatures calculated with the thermal analysis model. To rule out the possibility that the used ATR driver fuel elements were the root cause of these temperature differences, an experiment was devised to measure the axial fast and thermal neutron flux profiles in the northeast flux trap containing the AGR-3/4 experiment. An important input parameter to the thermal analysis model was the calculated compact heat rates from the MCNP physics model. To verify these calculated heat rates were consistent with the ATR driver fuel element loading and operating lobe power, axial flux wires were inserted into ATR northeast flux trap. The measured fast and thermal neutron axial flux profiles derived from the flux wire activation showed excellent agreement with the calculated flux profiles. This agreement dispelled any concerns that the used ATR fuel elements in the northeast lobe might have introduced unusual axial flux variation. In addition, the agreement provided a validation basis for the physics calculation, specifically, (1) MCNP physics model, (2) Monte Carlo depletion methodology, (3) method used to load the ATR driver fuel, and (4) ATR measured lobe power data used in the calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling and optimization of solar thermoelectric generators for terrestrial applications

We introduce a model and an optimization methodology for terrestrial solar thermoelectric generators (STEGs). We describe, discuss, and justify the necessary constraints on the STEG geometry that make the STEG optimization independent of individual dimensions. A simplified model shows that the thermoelectric elements in STEGs can be scaled in size without affecting the overall performance of the device, even when the properties of the thermoelectric material and the solar absorber are temperature-dependent. Consequently, the amount of thermoelectric material can be minimized to be only a negligible fraction of the total system cost. As an example, a Bi 2 Te 3 -based STEG is optimized for rooftop power generation. Peak efficiency is predicted to be 5% at the standard spectrum AM1.5G, with the thermoelectric material cost below 0.05 $/W p . Integrating STEGs into solar hot water systems for cogeneration adds electricity at minimal extra cost. In such cogeneration systems the electric current can be adjusted throughout the day to favor either electricity or hot water production.

14 SOLAR ENERGY↗

Atomic Ordering-Induced Ensemble Variation in Alloys Governs Electrocatalyst On/Off States

The catalytic behavior of a material is influenced by ensembles—the geometric configuration of atoms. Traditional approaches, mainly utilizing solid-solution alloys in electrocatalysis, have often overlooked the challenges posed by concurrent changes in the electronic structure (i.e. d-band center) when the composition is altered. Here, this study introduces a methodology that distinctly separates the geometric effects (i.e. ensembles) from the electronic structure. We compare the reactivity of compositionally identical, but structurally different Pd 3 Bi ordered intermetallic and solid-solution alloys. Remarkably, we find that Pd 3 Bi intermetallics display nearly no reactivity for the methanol oxidation (MOR), while their solid-solution counterparts have significant reactivity. This highlights a unique case where materials with identical chemical compositions demonstrate drastically different catalytic behavior underscoring the critical importance of ensembles in electrocatalysis. Specifically, Pd 3 Bi intermetallics form smaller ensembles (average coordination number: 4.5 ± 1.6) with almost no measurable MOR activity at room temperature, in contrast to the solid-solution Pd 3 Bi that exhibit larger ensembles (average coordination number: 6.8 ± 0.9) and considerable MOR reactivity (0.5 mA cm −2 Pd ). An ordered Pd 3 Bi alloy, with an intermediate ensemble size (average coordination number: 5.3 ± 1.2), displays moderate MOR activity (0.1 mA cm −2 Pd ), further confirming the direct correlation between ensemble size and catalytic activity. Notably, all Pd 3 Bi alloys maintain similar electronic structures, because the chemical composition of the alloys is fixed, indicating that the differences in reactivity are predominantly from changes to the ensemble size. Our findings offer an approach for precisely controlling catalytic activity through manipulating the geometric configuration of the atoms within an alloy, paving the way for more efficient catalyst design.

alloys↗