Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

SU-G-BRA-05: Application of a Feature-Based Tracking Algorithm to KV X-Ray Fluoroscopic Images Toward Marker-Less Real-Time Tumor Tracking

Purpose: To detect target position on kV X-ray fluoroscopic images using a feature-based tracking algorithm, Accelerated-KAZE (AKAZE), for markerless real-time tumor tracking (RTTT). Methods: Twelve lung cancer patients treated with RTTT on the Vero4DRT (Mitsubishi Heavy Industries, Japan, and Brainlab AG, Feldkirchen, Germany) were enrolled in this study. Respiratory tumor movement was greater than 10 mm. Three to five fiducial markers were implanted around the lung tumor transbronchially for each patient. Before beam delivery, external infrared (IR) markers and the fiducial markers were monitored for 20 to 40 s with the IR camera every 16.7 ms and with an orthogonal kV x-ray imaging subsystem every 80 or 160 ms, respectively. Target positions derived from the fiducial markers were determined on the orthogonal kV x-ray images, which were used as the ground truth in this study. Meanwhile, tracking positions were identified by AKAZE. Among a lot of feature points, AKAZE found high-quality feature points through sequential cross-check and distance-check between two consecutive images. Then, these 2D positional data were converted to the 3D positional data by a transformation matrix with a predefined calibration parameter. Root mean square error (RMSE) was calculated to evaluate the difference between 3D tracking and target positions. A total of 393 frames was analyzed. The experiment was conducted on a personal computer with 16 GB RAM, Intel Core i7-2600, 3.4 GHz processor. Results: Reproducibility of the target position during the same respiratory phase was 0.6 +/− 0.6 mm (range, 0.1–3.3 mm). Mean +/− SD of the RMSEs was 0.3 +/− 0.2 mm (range, 0.0–1.0 mm). Median computation time per frame was 179 msec (range, 154–247 msec). Conclusion: AKAZE successfully and quickly detected the target position on kV X-ray fluoroscopic images. Initial results indicate that the differences between 3D tracking and target position would be clinically acceptable.

60 APPLIED LIFE SCIENCES↗

SU-E-J-64: Feasibility Study of Surgical Clips for Fiducial Tracking in CyberKnife System

Purpose: To investigate the ability of CyberKnife to track surgical clips used as fiducial markers. Methods: The Octavius 1000SRS detector and solid water (RW3) slab phantom were used with motion platform to evaluate the study. The RW3 slab phantom was set up to measure the dose distribution from coronal plane. It consists of 9 plates and the thickness of each plate is 10mm. Among them, one plate was attached with 3 surgical clips, which are orthogonally positioned on outer region of array. The length of attached clip was represented as 1cm on planning CT. The clip plate was placed on the 1000SRS detector and 3 slabs were stacked up on the plate to build the measuring depth. Below the detector, 5 slabs were set. The two-axis motion platform was programmed with 1D sinusoidal movement (20mm peak-to-peak, 3s period) toward superior/inferior and left/right directions to simulate target motion. During delivery, two clips were extracted by two X-ray imagers, which led to translational error correction only. Synchrony was also used for dynamic tracking. After the irradiation, the measured dose distribution of coronal plane was compared with the planar dose distribution calculated by the CyberKnife treatment planning system (Multiplan) for cross verification. The results were assessed by comparing the absolute Gamma (γ) index. Results: The dose distributions measured by the 1000SRS detector were in good agreements with those calculated by Multiplan. In the dosimetric comparison using γ-function criteria based on the distance-to-agreement of 3mm and the local dose difference of 3%, the passing rate with γ- parameter ≤1 was 91% in coronal plane. Conclusion: The surgical clips can be considered as new fiducials for robotic radiosurgery delivery by considering the target margin with less than 5mm.

60 APPLIED LIFE SCIENCES↗

Simplified formula for mean cycle-slip time of phase-locked loops with steady-state phase error.

Previous work shows that the mean time from lock to a slipped cycle of a phase-locked loop is given by a certain double integral. Accurate numerical evaluation of this formula for the second-order loop is extremely vexing because the difference between exponentially large quantities is involved. The presented article demonstrates a method in which a much-reduced precision program can be used to obtain the mean first-cycle slip time for a loop of arbitrary degree tracking at a specified SNR and steady-state phase error. It also presents a simple approximate formula that is asymptotically tight at higher loop SNR.

Tausworthe, R. C.↗

Satellite-satellite tracking for estimating geopotential coefficients.

Results of simulation studies of tracking of low-altitude satellites by a high-altitude satellite using range measurements between satellites. The high-altitude satellite is tracked by ground-based range trackers. The low-altitude satellites are tracked only by the high-altitude satellites. Orbital elements for one tracking satellite and four tracked low-altitude satellites are estimated, along with a set of low degree and order geopotential coefficients. Estimation of geopotential coefficients of low degree and order is shown to be considerably more accurate using satellite-to-satellite tracking than using ground-based tracking. The use of data from one high-altitude satellite tracking four low-altitude satellites in a range of inclinations is shown to produce geopotential coefficient estimates with smaller errors than presently exist in individual coefficients or would be obtained using ground-based tracking of the same satellites.

Martin, C. F.↗

Mesoscale Convective Systems Represented in High Resolution E3SMv2 and Impact of New Cloud and Convection Parameterizations

Mesoscale convective systems (MCSs) play an important role in modulating the global hydrological cycle, general circulation, and radiative energy budget. In this study, we evaluate MCS simulations in the second version of U.S. Department of Energy (DOE) Energy Exascale Earth System Model (E3SMv2). E3SMv2 atmosphere model (EAMv2) is run at the uniform 0.25? horizontal resolution. We track MCSs consistently in the model and observations using the PyFLEXTRKR algorithm, which defines MCS based on both cloud-top brightness temperature (Tb) and surface precipitation. Results from using Tb only to define MCS, commonly used in previous studies, are also discussed. Furthermore, sensitivity experiments are performed to examine the impact of new cloud and convection parameterizations developed for EAMv3 on simulated MCSs. Our results show that EAMv2 simulated MCS precipitation is largely underestimated in the tropics and contiguous United States. This is mainly attributed to the underestimated precipitation intensity in EAMv2. In contrast, the simulated MCS frequency becomes more comparable to observations if MCSs are defined only based on cloud-top Tb. The Tb-based MCS tracking method, however, includes many cloud systems with very weak precipitation which conflicts with the MCS definition. This result illustrates the importance of accounting for precipitation in evaluating simulated MCSs. We also find that the new physics parameterizations help increase the relative contribution of convective precipitation to total precipitation in the tropics, but the simulated MCS properties are generally not improved. This suggests that simulating MCSs will remain a challenge for the next version of E3SM.

Zhang, Meng↗

GTARG - The TOPEX/Poseidon ground track maintenance maneuver targeting program

GTARG is a computer program used to design orbit maintenance maneuvers for the TOPEX/Poseidon satellite. These maneuvers ensure that the ground track is kept within +/-1 km with of an = 9.9 day exact repeat pattern. Maneuver parameters are determined using either of two targeting strategies: longitude targeting, which maximizes the time between maneuvers, and time targeting, in which maneuvers are targeted to occur at specific intervals. The GTARG algorithm propagates nonsingular mean elements, taking into account anticipated error sigma's in orbit determination, Delta v execution, drag prediction and Delta v quantization. A satellite unique drag model is used which incorporates an approximate mean orbital Jacchia-Roberts atmosphere and a variable mean area model. Maneuver Delta v magnitudes are targeted to precisely maintain either the unbiased ground track itself, or a comfortable (3 sigma) error envelope about the unbiased ground track.

Shapiro, Bruce E.↗

Multiple object tracking with non-unique data-to-object association via generalized hypothesis testing

A generalized hypothesis testing approach is applied to the problem of tracking several objects where several different associations of data with objects are possible. Such problems occur, for instance, when attempting to distinctly track several aircraft maneuvering near each other or when tracking ships at sea. Conceptually, the problem is solved by first, associating data with objects in a statistically reasonable fashion and then, tracking with a bank of Kalman filters. The objects are assumed to have motion characterized by a fixed but unknown deterministic portion plus a random process portion modeled by a shaping filter. For example, the object might be assumed to have a mean straight line path about which it maneuvers in a random manner. Several hypothesized associations of data with objects are possible because of ambiguity as to which object the data comes from, false alarm/detection errors, and possible uncertainty in the number of objects being tracked. The statistical likelihood function is computed for each possible hypothesized association of data with objects. Then the generalized likelihood is computed by maximizing the likelihood over parameters that define the deterministic motion of the object.

Porter, D. W.↗

Limits to the Stability of Phase Transfer from Ground to Space

An alternative to having a primary frequency standard on board a spacecraft is to phase lock a simple oscillator on the spacecraft to a microwave tone transmitted from the ground. The received tone is transponded and rebroadcast to the ground. The round trip phase is measured, and used to correct for effects on time scales longer than the round trip light travel time. This method is used with the TDRSS relay satellites, and will be used for the Japanese space VLBI mission VSOP. There are several sources of error introduced by this process. The most important error source is a loss of the on board standard for all times that the satellite is out of contact with a ground tracking station. The fractional loss will be greater than 10% for almost any orbit, even with a network of several ground tracking stations, and it will be considerably worse for a low earth orbit. Only a geostationary orbit can eliminate this problem. Another error source is connected to the previous one. Round trip phase tracking can remove, after the fact, link effects during a tracking pass on time scales greater than the round trip light travel time. However, there will be a jump in the spacecraft clock when multiple passes are connected (e.g. when the spacecraft is reacquired after passing out of sight). These jumps will be equal in magnitude (except for a geometrical factor) to the accuracy with which the spacecraft orbit is known. With a GPS receiver and GPS-like beacon on a spacecraft, the orbit can be known to a few cm, giving timing jumps on the order of 100 picoseconds. Even with a geostationary orbit, these jumps would occur any time the link was interrupted due to mechanical or electrical problems.

Linfield, Roger P.↗

Minimizing selective availability error on Topex GPS measurements

GPS measurements made at Topex/Poseidon and the accompanying ground tracking sites will be affected by the selective availability. Although in principle the effects may be removed by differencing between receivers observing the same GPS satellites, this requires accurate synchronization of all receiver clocks. In the case of Topex/Poseidon application, there are two sources of imperfect clock synchronization. The first and larger is due to the constantly drifting clock onboard Topex, which may cause a residual effect as large as 10 cm on Topex carrier phase and 1 m on Topex pseudorange. The second is due to light-time differences between receivers observing the same GPS satellites, which may amount to a few mm error. In this paper a data reduction scheme which incorporates a low-order polynomial interpolation and carrier phase smoothing on pseudorange acquired at Topex and ground receivers is described; a simulation analysis is given demonstrating the effectiveness of the scheme for reducing the GPS S/A effects; and comparison with other schemes is discussed.

Wu, S. C.↗

A nanoradian differential VLBI tracking demonstration

The shift due to Jovian gravitational deflection in the apparent angular position of the radio source P 0201+113 was measured with very long baseline interferometry (VLBI) to demonstrate a differential angular tracking technique with nanoradian accuracy. The raypath of the radio source P 0201+113 passed within 1 mrad of Jupiter (approximately 10 Jovian radii) on 21 Mar. 1988. Its angular position was measured 10 times over 4 hours on that date, with a similar measurement set on 2 Apr. 1988, to track the differential angular gravitational deflection of the raypath. According to general relativity, the expected gravitational bend of the raypath averaged over the duration of the March experiment was approximately 1.45 nrad projected onto the two California-Australia baselines over which it was measured. Measurement accuracies on the order of 0.78 nrad were obtained for each of the ten differential measurements. The chi(exp 2) per degree of freedom of the data for the hypothesis of general relativity was 0.6, which suggests that the modeled dominant errors due to system noise and tropospheric fluctuations fully accounted for the scatter in the measured angular deflections. The chi(exp 2) per degree of freedom for the hypothesis of no gravitational deflection by Jupiter was 4.1, which rejects the no-deflection hypothesis with greater than 99.999 percent confidence. The system noise contributed about 0.34 nrad per combined-baseline differential measurement and tropospheric fluctuations contributed about 0.70 nrad. Unmodeled errors were assessed, which could potentially increase the 0.78 nrad error by about 8 percent. The above chi(exp 2) values, which result from the full accounting of errors, suggest that the nanoradian gravitational deflection signature was successfully tracked.

Treuhaft, R. N.↗

Calibration of the Space Shuttle Microwave Scanning Beam Landing System using a laser tracker

Verification tests of the Space Shuttle Microwave Scanning Beam Landing System (MSBLS) performed with respect to the Precision Laser Tracking System are reported. MSBLS ground station measurements of the azimuth, elevation and range of a NASA Jetstar aircraft equipped with a laser retroreflector, a MSBLS antenna and commissioning instruments including a MSBLS navigation set of the type installed in the Orbiter, during the performance of radial, orbital and glideslope runs with respect to the ground station were compared with laser ground station measurements of aircraft position. Data obtained from flight testing at Shuttle landing sites reveal MSBLS distance measuring equipment performance to be very good, with elevation errors found at very low elevation angles and azimuth errors as a function of aircraft attitude. The Precision Laser Tracking System has thus proven to be a satisfactory instrument for determining MSBLS performance, and an ideal instrument for its calibration.

Ford, K.↗

Field Quality Measurement of a 4.2-m-Long Prototype Low- $\beta$ Nb $_3$ Sn Quadrupole Magnet During the Assembly Stage for the High-Luminosity LHC Accelerator Upgrade Project

The U.S. High-Luminosity LHC Accelerator Upgrade Project, in collaboration with CERN, is developing Nb 3 Sn quadrupole magnets (MQXFA) to be installed at the interaction region of the LHC. The project will deliver 20 MQXFA magnets in 10 cold masses. These magnets need to meet the stringent requirements on field quality at the nominal operating current. Compared to the mature NbTi accelerator magnet technology, achieving excellent field quality can be challenging for Nb 3 Sn magnets. To help track, understand, and allow effective correction of geometric field errors, field quality measurements at room temperature during the MQXFA assembly stage was planned for the project. The measurements also intend to evaluate the magnetic axis and twist angle along the magnet aperture. We report the first measurement on a prototype MQXFA magnet using a recently developed measurement system. The magnetic axis and twist angle met the acceptance criteria. Further development needs for the room-temperature measurements were discussed. Here, we expect that statistics obtained from such measurements throughout the project will provide insight into future applications of high-performance Nb 3 Sn accelerator magnets.

43 PARTICLE ACCELERATORS↗

Optimization of an on-board imaging system for extremely rapid radiation therapy

Purpose: Next-generation extremely rapid radiation therapy systems could mitigate the need for motion management, improve patient comfort during the treatment, and increase patient throughput for cost effectiveness. Such systems require an on-board imaging system that is competitively priced, fast, and of sufficiently high quality to allow good registration between the image taken on the day of treatment and the image taken the day of treatment planning. In this study, three different detectors for a custom on-board CT system were investigated to select the best design for integration with an extremely rapid radiation therapy system. Methods: Three different CT detectors are proposed: low-resolution (all 4 × 4 mm pixels), medium-resolution (a combination of 4 × 4 mm pixels and 2 × 2 mm pixels), and high-resolution (all 1 × 1 mm pixels). An in-house program was used to generate projection images of a numerical anthropomorphic phantom and to reconstruct the projections into CT datasets, henceforth called “realistic” images. Scatter was calculated using a separate Monte Carlo simulation, and the model included an antiscatter grid and bowtie filter. Diagnostic-quality images of the phantom were generated to represent the patient scan at the time of treatment planning. Commercial deformable registration software was used to register the diagnostic-quality scan to images produced by the various on-board detector configurations. The deformation fields were compared against a “gold standard” deformation field generated by registering initial and deformed images of the numerical phantoms that were used to make the diagnostic and treatment-day images. Registrations of on-board imaging system data were judged by the amount their deformation fields differed from the corresponding gold standard deformation fields—the smaller the difference, the better the system. To evaluate the registrations, the pointwise distance between gold standard and realistic registration deformation fields was computed. Results: By most global metrics (e.g., mean, median, and maximum pointwise distance), the high-resolution detector had the best performance but the medium-resolution detector was comparable. For all medium- and high-resolution detector registrations, mean error between the realistic and gold standard deformation fields was less than 4 mm. By pointwise metrics (e.g., tracking a small lesion), the high- and medium-resolution detectors performed similarly. For these detectors, the smallest error between the realistic and gold standard registrations was 0.6 mm and the largest error was 3.6 mm. Conclusions: The medium-resolution CT detector was selected as the best for an extremely rapid radiation therapy system. In essentially all test cases, data from this detector produced a significantly better registration than data from the low-resolution detector and a comparable registration to data from the high-resolution detector. The medium-resolution detector provides an appropriate compromise between registration accuracy and system cost.

60 APPLIED LIFE SCIENCES↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗

Tracking system study

A digital computer program was generated which mathematically describes an optimal estimator-controller technique as applied to the control of antenna tracking systems used by NASA. Simulation studies utilizing this program were conducted using the IBM 360/91 computer. The basic ideas of applying optimal estimator-controller techniques to antenna tracking systems are discussed. A survey of existing tracking methods is given along with shortcomings and inherent errors. It is explained how these errors can be considerably reduced if optimal estimation and control are used. The modified programs generated in this project are described and the simulation results are summarized. The new algorithms for direct synthesis and stabilization of the systems including nonlinearities, are presented.

Dennis, A. R.↗

A one way Doppler tracking system for satellite to satellite tracking

An S-band tracking system employing one way Doppler applicable to the tracking and data relay system (TDRS) was evaluated. This evaluation is limited to the measurement system parameters. The analysis assumes state-of-the-art components such as spacecraft oscillator long term stability of one part in 10 to the 8th power and ground station oscillator stability of one part in 10 to the 11th power. Signal characteristics comparable with the present ranging systems are utilized in the analysis. Predicated upon measurement system parameters, position uncertainties for the low orbiting spacecraft vary from 5 meters to 2 kilometers along track, 4 meters to 1 kilometer cross track, and 1 meter to 180 meters radially depending upon the tracking geometry and the high satellite position and velocity error assumptions.

Bryan, J. W.↗

Flight evaluation of two segment approaches for jet transport noise abatement

A 75 flight-hour operational evaluation was conducted with a representative four-engine fan-jet transport in a representative airport environment. The flight instrument systems were modified to automatically provide pilots with smooth and continuous pitch steering command information during two-segment approaches. Considering adverse weather, minimum ceiling and flight crew experience criteria, a transition initiation altitude of approximately 800 feet AFL would have broadest acceptance for initiating two-segment approach procedures in scheduled service. The profile defined by the system gave an upper glidepath of approximately 6 1/2 degrees. This was 1/2 degree greater than inserted into the area navigation system. The glidepath error is apparently due to an erroneous along-track, distance-to-altitude profile.

Rogers, R. A.↗

A multiloop approach to modeling motion sensor responses

By using a least squares identification algorithm, a multiloop approach is taken to effectively model the response characteristics of the motion sensors. The inputs to the model include the possible sources of information provided to the human via his motion sensing system. One input models the response of the angular acceleration sensors (second derivative of position) and the second input models the response of the linear sensors (sine of position). The third input is the visual display error provided to the human in the closed loop tracking experiment. Data from a roll axis tracking simulation were analyzed. The major source of pilot lead under the motion mode of operation is discussed for control of plants in which motion information improved performance and in which there was no improvement in performance.

Junker, A. M.↗