Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Online Kidney Position Verification Using Non-Contrast Radiographs on a Linear Accelerator with on Board KV X-Ray Imaging Capability

The kidneys are dose-limiting organs in abdominal radiotherapy. Kilovoltage (kV) radiographs can be acquired using on-board imager (OBI)-equipped linear accelerators with better soft tissue contrast and lower radiation doses than conventional portal imaging. A feasibility study was conducted to test the suitability of anterior-posterior (AP) non-contrast kV radiographs acquired at treatment time for online kidney position verification. Anthropomorphic phantoms were used to evaluate image quality and radiation dose. Institutional Review Board approval was given for a pilot study that enrolled 5 adults and 5 children. Customized digitally reconstructed radiographs (DRRs) were generated to provide a priori information on kidney shape and position. Radiotherapy treatment staff performed online evaluation of kidney visibility on OBI radiographs. Kidney dose measured in a pediatric anthropomorphic phantom was 0.1 cGy for kV imaging and 1.7 cGy for MV imaging. Kidneys were rated as well visualized in 60% of patients (90% confidence interval, 34-81%). The likelihood of visualization appears to be influenced by the relative AP separation of the abdomen and kidneys, the axial profile of the kidneys, and their relative contrast with surrounding structures. Online verification of kidney position using AP non-contrast kV radiographs on an OBI-equipped linear accelerator appears feasible for patients with suitable abdominal anatomy. Kidney position information provided is limited to 2-dimensional 'snapshots,' but this is adequate in some clinical situations and potentially advantageous in respiratory-correlated treatments. Successful clinical implementation requires customized partial DRRs, appropriate imaging parameters, and credentialing of treatment staff.

61 RADIATION PROTECTION AND DOSIMETRY↗

Decision Making In A High-Tech World: Automation Bias and Countermeasures

Automated decision aids and decision support systems have become essential tools in many high-tech environments. In aviation, for example, flight management systems computers not only fly the aircraft, but also calculate fuel efficient paths, detect and diagnose system malfunctions and abnormalities, and recommend or carry out decisions. Air Traffic Controllers will soon be utilizing decision support tools to help them predict and detect potential conflicts and to generate clearances. Other fields as disparate as nuclear power plants and medical diagnostics are similarly becoming more and more automated. Ideally, the combination of human decision maker and automated decision aid should result in a high-performing team, maximizing the advantages of additional cognitive and observational power in the decision-making process. In reality, however, the presence of these aids often short-circuits the way that even very experienced decision makers have traditionally handled tasks and made decisions, and introduces opportunities for new decision heuristics and biases. Results of recent research investigating the use of automated aids have indicated the presence of automation bias, that is, errors made when decision makers rely on automated cues as a heuristic replacement for vigilant information seeking and processing. Automation commission errors, i.e., errors made when decision makers inappropriately follow an automated directive, or automation omission errors, i.e., errors made when humans fail to take action or notice a problem because an automated aid fails to inform them, can result from this tendency. Evidence of the tendency to make automation-related omission and commission errors has been found in pilot self reports, in studies using pilots in flight simulations, and in non-flight decision making contexts with student samples. Considerable research has found that increasing social accountability can successfully ameliorate a broad array of cognitive biases and resultant errors. To what extent these effects generalize to performance situations is not yet empirically established. The two studies to be presented represent concurrent efforts, with student and professional pilot samples, to determine the effects of accountability pressures on automation bias and on the verification of the accurate functioning of automated aids. Students (Experiment 1) and commercial pilots (Experiment 2) performed simulated flight tasks using automated aids. In both studies, participants who perceived themselves as accountable for their strategies of interaction with the automation were significantly more likely to verify its correctness, and committed significantly fewer automation-related errors than those who did not report this perception.

Mosier, Kathleen L.↗

Hybrid Simulations of Interstellar Pickup Ion Acceleration at the Solar Wind Termination Shock

Hybrid (kinetic ion/fluid electron) simulations have been used to study self-consistently the injection and initial stages of acceleration of interstellar pickup ions at the solar wind termination shock. Results are presented from one-dimensional simulations of high Mach number oblique (40 deg-50 deg) shocks with a 10% population of interstellar pickup hydrogen. In these simulations, the pickup ions, the solar wind ions, the shock fields and the waves are all treated self-consistently. Pickup ions reflected by the shock excite large amplitude (DELTA.B / B approximately 0.3) upstream magnetosonic waves. These waves, in turn, scatter the pickup hydrogen, as expected in the diffusive shock acceleration process. The spectrum of excited waves broadens in time. We find that, for the parameters studied, the termination shock efficiently injects and accelerates the interstellar pickup hydrogen, and thus this work represents a microscopic verification of this anomalous cosmic ray injection mechanism. Comparison of injected fluxes from the simulations with Voyager fluxes extrapolated to the termination shock suggests that injection at the termination shock is probably greater than injection by interplanetary shocks. A study of accelerated pickup ion orbits shows that the energy gain comes predominantly from shock drift acceleration in the shock front, with the upstream waves aiding the acceleration by allowing multiple encounters with the shock.

Liewer, P. C.↗

High-Resolution Fast-Neutron Spectrometry for Arms Control and Treaty Verification

Many nondestructive nuclear analysis techniques have been developed to support the measurement needs of arms control and treaty verification, including gross photon and neutron counting, low- and high-resolution gamma spectrometry, time-correlated neutron measurements, and photon and neutron imaging. One notable measurement technique that has not been extensively studied to date for these applications is high-resolution fast-neutron spectrometry (HRFNS). Applied for arms control and treaty verification, HRFNS has the potential to serve as a complimentary measurement approach to these other techniques by providing a means to either qualitatively or quantitatively determine the composition and thickness of non-nuclear materials surrounding neutron-emitting materials. The technique uses the normally-occurring neutrons present in arms control and treaty verification objects of interest as an internal source of neutrons for performing active-interrogation transmission measurements. Most low-Z nuclei of interest for arms control and treaty verification, including 9Be, 12C, 14N, and 16O, possess fast-neutron resonance features in their absorption cross sections in the 0.5- to 5-MeV energy range. Measuring the selective removal of source neutrons over this energy range, assuming for example a fission-spectrum starting distribution, may be used to estimate the stoichiometric composition of intervening materials between the neutron source and detector. At a simpler level, determination of the emitted fast-neutron spectrum may be used for fingerprinting 'known' assemblies for later use in template-matching tests. As with photon spectrometry, automated analysis of fast-neutron spectra may be performed to support decision making and reporting systems protected behind information barriers. This paper will report recent work at Idaho National Laboratory to explore the feasibility of using HRFNS for arms control and treaty verification applications, including simulations and experiments, using fission-spectrum neutron sources to assess neutron transmission through composite low-Z attenuators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Quasi-Global Approach to Improve Day-Time Satellite Surface Soil Moisture Anomalies through the Land Surface Temperature Input

Passive microwave observations from various spaceborne sensors have been linked to the soil moisture of the Earth's surface layer. A new generation of passive microwave sensors are dedicated to retrieving this variable and make observations in the single theoretically optimal L-band frequency (1-2 GHz). Previous generations of passive microwave sensors made observations in a range of higher frequencies, allowing for simultaneous estimation of additional variables required for solving the radiative transfer equation. One of these additional variables is land surface temperature, which plays a unique role in the radiative transfer equation and has an influence on the final quality of retrieved soil moisture anomalies. This study presents an optimization procedure for soil moisture retrievals through a quasi-global precipitation-based verification technique, the so-called Rvalue metric. Various land surface temperature scenarios were evaluated in which biases were added to an existing linear regression, specifically focusing on improving the skills to capture the temporal variability of soil moisture. We focus on the relative quality of the day-time (01:30 pm) observations from the Advanced Microwave Scanning Radiometer for Earth Observing System (AMSR-E), as these are theoretically most challenging due to the thermal equilibrium theory, and existing studies indicate that larger improvements are possible for these observations compared to their night-time (01:30 am) equivalent. Soil moisture data used in this study were retrieved through the Land Parameter Retrieval Model (LPRM), and in line with theory, both satellite paths show a unique and distinct degradation as a function of vegetation density. Both the ascending (01:30 pm) and descending (01:30 am) paths of the publicly available and widely used AMSR-E LPRM soil moisture products were used for benchmarking purposes. Several scenarios were employed in which the land surface temperature input for the radiative transfer was varied by imposing a bias on an existing regression. These scenarios were evaluated through the Rvalue technique, resulting in optimal bias values on top of this regression. In a next step, these optimal bias values were incorporated in order to re-calibrate the existing linear regression, resulting in a quasi-global uniform LST relation for day-time observations. In a final step, day-time soil moisture retrievals using the re-calibrated land surface temperature relation were again validated through the Rvalue technique. Results indicate an average increasing Rvalue of 16.5%, which indicates a better performance obtained through the re-calibration. This number was confirmed through an independent Triple Collocation verification over the same domain, demonstrating an average root mean square error reduction of 15.3%. Furthermore, a comparison against an extensive in situ database (679 stations) also indicates a generally higher quality for the re-calibrated dataset. Besides the improved day-time dataset, this study furthermore provides insights on the relative quality of soil moisture retrieved from AMSR-E's day- and night-time observations.

soil moisture↗

SU-E-T-339: Dosimetric Verification of Acuros XB Dose Calculation Algorithm On An Air Cavity for 6-MV Flattening Filter-Free Beam

Purpose: This study was to verify the accuracy of Acuros XB (AXB) dose calculation algorithm on an air cavity for a single radiation field using 6-MV flattening filter-free (FFF) beam. Methods: A rectangular slab phantom containing an air cavity was made for this study. The CT images of the phantom for dose calculation were scanned with and without film at measurement depths (4.5, 5.5, 6.5 and 7.5 cm). The central axis doses (CADs) and the off-axis doses (OADs) were measured by film and calculated with Analytical Anisotropic Algorithm (AAA) and AXB for field sizes ranging from 2 Χ 2 to 5 Χ 5 cm{sup 2} of 6-MV FFF beams. Both algorithms were divided into AXB-w and AAA -w when included the film in phantom for dose calculation, and AXB-w/o and AAA-w/o in calculation without film. The calculated OADs for both algorithms were compared with the measured OADs and difference values were determined using root means squares error (RMSE) and gamma evaluation. Results: The percentage differences (%Diffs) between the measured and calculated CAD for AXB-w was most agreement than others. Compared to the %Diff with and without film, the %Diffs with film were decreased than without within both algorithms. The %Diffs for both algorithms were reduced with increasing field size and increased relative to the depth increment. RMSEs of CAD for AXB-w were within 10.32% for both inner-profile and penumbra, while the corresponding values of AAA-w appeared to 96.50%. Conclusion: This study demonstrated that the dose calculation with AXB within air cavity shows more accurate than with AAA compared to the measured dose. Furthermore, we found that the AXB-w was superior to AXB-w/o in this region when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

Dosimetric verification of the anisotropic analytical algorithm in lung equivalent heterogeneities with and without bone equivalent heterogeneities

Purpose: In this study, the authors evaluated the accuracy of dose calculations performed by the convolution/superposition based anisotropic analytical algorithm (AAA) in lung equivalent heterogeneities with and without bone equivalent heterogeneities. Methods: Calculations of PDDs using the AAA and Monte Carlo simulations (MCNP4C) were compared to ionization chamber measurements with a heterogeneous phantom consisting of lung equivalent and bone equivalent materials. Both 6 and 10 MV photon beams of 4x4 and 10x10 cm{sup 2} field sizes were used for the simulations. Furthermore, changes of energy spectrum with depth for the heterogeneous phantom using MCNP were calculated. Results: The ionization chamber measurements and MCNP calculations in a lung equivalent phantom were in good agreement, having an average deviation of only 0.64{+-}0.45%. For both 6 and 10 MV beams, the average deviation was less than 2% for the 4x4 and 10x10 cm{sup 2} fields in the water-lung equivalent phantom and the 4x4 cm{sup 2} field in the water-lung-bone equivalent phantom. Maximum deviations for the 10x10 cm{sup 2} field in the lung equivalent phantom before and after the bone slab were 5.0% and 4.1%, respectively. The Monte Carlo simulation demonstrated an increase of the low-energy photon component in these regions, more for the 10x10 cm{sup 2} field compared to the 4x4 cm{sup 2} field. Conclusions: The low-energy photon by Monte Carlo simulation component increases sharply in larger fields when there is a significant presence of bone equivalent heterogeneities. This leads to great changes in the build-up and build-down at the interfaces of different density materials. The AAA calculation modeling of the effect is not deemed to be sufficiently accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Construction of Polarimetric Radar-Based Reference Rain Maps for the Iowa Flood Studies Campaign

The Global Precipitation Measurement (GPM) Mission Iowa Flood Studies (IFloodS) campaign was conducted in central and northeastern Iowa during the months of April-June, 2013. Specific science objectives for IFloodS included quantification of uncertainties in satellite and ground-based estimates of precipitation, 4-D characterization of precipitation physical processes and associated parameters (e.g., size distributions, water contents, types, structure etc.), assessment of the impact of precipitation estimation uncertainty and physical processes on hydrologic predictive skill, and refinement of field observations and data analysis approaches as they pertain to future GPM integrated hydrologic validation and related field studies. In addition to field campaign archival of raw and processed satellite data (including precipitation products), key ground-based platforms such as the NASA NPOL S-band and D3R Ka/Ku-band dual-polarimetric radars, University of Iowa X-band dual-polarimetric radars, a large network of paired rain gauge platforms, and a large network of 2D Video and Parsivel disdrometers were deployed. In something of a canonical approach, the radar (NPOL in particular), gauge and disdrometer observational assets were deployed to create a consistent high-quality distributed (time and space sampling) radar-based ground "reference" rainfall dataset, with known uncertainties, that could be used for assessing the satellite-based precipitation products at a range of space/time scales. Subsequently, the impact of uncertainties in the satellite products could be evaluated relative to the ground-benchmark in coupled weather, land-surface and distributed hydrologic modeling frameworks as related to flood prediction. Relative to establishing the ground-based "benchmark", numerous avenues were pursued in the making and verification of IFloodS "reference" dual-polarimetric radar-based rain maps, and this study documents the process and results as they pertain specifically to efforts using the NPOL radar dataset. The initial portions of the "process" involved dual-polarimetric quality control procedures which employed standard phase and correlation-based approaches to removal of clutter and non-meteorological echo. Calculation of a scale-adaptive KDP was accomplished using the method of Wang and Chandrasekar (2009; J. Atmos. Oceanic Tech.). A dual-polarimetric blockage algorithm based on Lang et al. (2009; J. Atmos. Oceanic Tech.) was then implemented to correct radar reflectivity and differential reflectivity at low elevation angles. Next, hydrometeor identification algorithms were run to identify liquid and ice hydrometeors. After the quality control and data preparation steps were completed several different dual-polarimetric rain estimation algorithms were employed to estimate rainfall rates using rainfall scans collected approximately every two to three minutes throughout the campaign. These algorithms included a polarimetrically-tuned Z-R algorithm that adjusts for drop oscillations (via Bringi et al., 2004, J. Atmos. Oceanic Tech.), and several different hybrid polarimetric variable approaches, including one that made use of parameters tuned to IFloodS 2D Video Disdrometer measurements. Finally, a hybrid scan algorithm was designed to merge the rain rate estimates from multiple low level elevation angle scans (where blockages could not be appropriately corrected) in order to create individual low-level rain maps. Individual rain maps at each time step were subsequently accumulated over multiple time scales for comparison to gauge network data. The comparison results and overall error character depended strongly on rain event type, polarimetric estimator applied, and range from the radar. We will present the outcome of these comparisons and their impact on constructing composited "reference" rainfall maps at select time and space scales.

Radar↗

SU-F-T-609: Impact of Dosimetric Variation for Prescription Dose Using Analytical Anisotropic Algorithm (AAA) in Lung SBRT

Purpose: Actual irradiated prescription dose to patients cannot be verified. Thus, independent dose verification and second treatment planning system are used as the secondary check. AAA dose calculation engine has contributed to lung SBRT. We conducted a multi-institutional study to assess variation of prescription dose for lung SBRT when using AAA in reference to using Acuros XB and Clarkson algorithm. Methods: Six institutes in Japan participated in this study. All SBRT treatments were planed using AAA in Eclipse and Adaptive Convolve (AC) in Pinnacle3. All of the institutes used a same independent dose verification software program (Simple MU Analysis: SMU, Triangle Product, Ishikawa, Japan), which implemented a Clarkson-based dose calculation algorithm using CT image dataset. A retrospective analysis for lung SBRT plans (73 patients) was performed to compute the confidence limit (CL, Average±2SD) in dose between the AAA and the SMU. In one of the institutes, a additional analysis was conducted to evaluate the variations between the AAA and the Acuros XB (AXB). Results: The CL for SMU shows larger systematic and random errors of 8.7±9.9 % for AAA than the errors of 5.7±4.2 % for AC. The variations of AAA correlated with the mean CT values in the voxels of PTV (a correlation coefficient : −0.7) . The comparison of AXB vs. AAA shows smaller systematic and random errors of −0.7±1.7%. The correlation between dose variations for AXB and the mean CT values in PTV was weak (0.4). However, there were several plans with more than 2% deviation of AAPM TG114 (Maximum: −3.3 %). Conclusion: In comparison for AC, prescription dose calculated by AAA may be more variable in lung SBRT patient. Even AXB comparison shows unexpected variation. Care should be taken for the use of AAA in lung SBRT. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Laboratory-Scale Microgrid System for Control of Power Distribution in Local Energy Networks - Part II: Implementation and Case Study

In this chapter, we provide the detailed implementation of the proposed microgrid framework in part I. As a case study, a droop-based load sharing algorithm with the capability of controlling the active and reactive power have been implemented. Several load sharing scenarios have been studied to verify the capability of the suggested prototype in performance evaluation and verification of different control strategies in microgrid systems. The performed experiments confirm the capacity of the proposed structure in microgrid research and development (R&D), as well as education.

design↗

A Visual Analytics Framework for the Detection of Anomalous Call Stack Trees in High Performance Computing Applications

Anomalous runtime behavior detection is one of the most important tasks for performance diagnosis in High Performance Computing (HPC). Most of the existing methods find anomalous executions based on the properties of individual functions, such as execution time. However, it is insufficient to identify abnormal behavior without taking into account the context of the executions, such as the invocations of children functions and the communications with other HPC nodes. We improve upon the existing anomaly detection approaches by utilizing the call stack structures of the executions, which record rich temporal and contextual information. With our call stack tree (CSTree) representation of the executions, we formulate the anomaly detection problem as finding anomalous tree structures in a call stack forest. The CSTrees are converted to vector representations using our proposed stack2vec embedding. Structural and temporal visualizations of CSTrees are provided to support users in the identification and verification of the anomalies during an active anomaly detection process. Furthermore, three case studies of real-world HPC applications demonstrate the capabilities of our approach.

97 MATHEMATICS AND COMPUTING↗

High resolution 3D imaging of synchrotron generated microbeams

Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE® dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE® dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25–50 μm wide with 200 or 400 μm peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 μm/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE® dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery.

60 APPLIED LIFE SCIENCES↗

Use of radiochromic film as a high-spatial resolution dosimeter by Raman spectroscopy

Purpose: Due to increasing demand for high-spatial resolution dosimetry, radiochromic films have been investigated as potential candidates but are often limited by the scanning system, e.g., flatbed optical scanner. In this study, Raman spectroscopy in conjunction with a microscope was selected as an alternative method for high-spatial resolution dosimetry of radiochromic film. Methods: Unlaminated Gafchromic™ EBT3 films were irradiated with doses between 0 and 50 Gy using 6 MV x-rays of a clinical linear accelerator. Depth profiling from the surface of unlaminated film was performed to acquire the maximum Raman intensity peaks of C≡C and C=C stretching bands of diacetylene polymer. The Raman mapping technique for a region of interest (200 × 200, 30 × 30 μm{sup 2}) was developed to reduce a large variation in a Raman spectrum produced with a sampling resolution of a few μm. The preprocessing of Raman spectra was carried out to determine a dosimetric relationship with the amount of diacetylene polymerization. Results: Due to partial diacetylene polymerization upon irradiation, two Raman peaks of C=C and C≡C stretching bands were observed around 1447 and 2060 cm{sup −1}, respectively. The maximum intensities of the two peaks were obtained by positioning a focused laser spot on the surface of unlaminated film. For the dose range of 0–50 Gy, the band heights of both C≡C and C=C peaks increase asymptotically with increasing doses and can be fit with an exponential function of two components. The relative standard deviation in Raman mapping was found to be less than ±5%. By using this technique, dose uniformity was found to be within ±2%. Conclusions: The Raman intensity for C=C and C≡C peaks increases with an increase in the amount of diacetylene polymerization due to an increase in dose. This study shows the potential of Raman spectroscopy as an alternative for absolute dosimetry verifications with a high-spatial resolution of a few μm, but these findings need to be further validated for the purpose of microdosimetry.

60 APPLIED LIFE SCIENCES↗

Statistical Treatment of Inverse Problems Constrained by Differential Equations-based Models with Stochastic Terms

This paper introduces a statistical treatment of inverse problems constrained by models with stochastic terms. The solution of the forward problem is given by a distribution represented numerically by an ensemble of simulations. The goal is to formulate the inverse problem, in particular the objective function, to find the closest forward distribution (i.e., the output of the stochastic forward problem) that best explains the distribution of the observations in a certain metric. We use proper scoring rules, a concept employed in statistical forecast verification, namely energy, variogram, and hybrid (i.e., combination of the two) scores. We study the performance of the proposed formulation in the context of two applications: a coefficient field inversion for subsurface flow governed by an elliptic partial differential equation with a stochastic source and a parameter inversion for power grid governed by differential-algebraic equations. In both cases we show that the variogram and the hybrid scores produce better parameter inversion results than does the energy score, whereas the energy score leads to better probabilistic predictions.

97 MATHEMATICS AND COMPUTING↗

SPG (Spectroscopic Planar Germanium): Field Tests and Instrument Improvements (Final Report)

The Spectroscopic Planar Germanium (SPG) has been demonstrated at the IAEA Physical Inventory Verification (PIV) in South Korea, as well as at the Joint Fuel Cycle Study at Idaho National Laboratory. These field tests were successful and provided valuable feedback from KINAC, IAEA, and national laboratory staff. This feedback was used to direct efforts to improve the instrument this year.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TEAMER Technical Support of Ramboll's for Numerical Modeling of WECs to Support OES Task 10: Cooperative Research and Development (Final Report)

National Technology & Engineering Solutions of Sandia, LLC (NTESS) in collaboration with the National Renewable Energy Laboratory (NREL), and with guidance from Ramboll, will perform fluid dynamics simulations to support of The Ocean Energy Systems (OES) Energy Technology Collaboration Program Task 10 Wave Energy Converters (WEC) Modelling Verification and Validation effort. Specific numerical simulations include the fixed device wave impingement studies to benchmark the performance of simulation techniques against physical testing results.

16 TIDAL AND WAVE POWER↗

The Ingestion of Fluorescent, Magnetic Nanoparticles for Determining Fluid-uptake Abilities in Insects

Here, fluid-feeding insects ingest a variety of liquids, which are present in the environment as pools, films, or confined to small pores. Studies of liquid acquisition require assessing mouthpart structure and function relationships; however, fluid uptake mechanisms are historically inferred from observations of structural architecture, sometimes unaccompanied with experimental evidence. Here, we report a novel method for assessing fluid-uptake abilities with butterflies (Lepidoptera) and flies (Diptera) using small amounts of liquids. Insects are fed with a 20% sucrose solution mixed with fluorescent, magnetic nanoparticles from filter papers of specific pore sizes. The crop (internal structure used for storing fluids) is removed from the insect and placed on a confocal microscope. A magnet is waved by the crop to determine the presence of nanoparticles, which indicate if the insects are able to ingest fluids. This methodology is used to reveal a widespread feeding mechanism (capillary action and liquid bridge formation) that is potentially shared among Lepidoptera and Diptera when feeding from porous surfaces. In addition, this method can be used for studies of feeding mechanisms among a variety of fluid-feeding insects, including those important in disease transmission and biomimetics, and potentially other studies that involve nano- or micro-sized conduits where liquid transport requires verification.

36 MATERIALS SCIENCE↗

Vector wind profile gust model

To enable development of a vector wind gust model suitable for orbital flight test operations and trade studies, hypotheses concerning the distributions of gust component variables were verified. Methods for verification of hypotheses that observed gust variables, including gust component magnitude, gust length, u range, and L range, are gamma distributed and presented. Observed gust modulus has been drawn from a bivariate gamma distribution that can be approximated with a Weibull distribution. Zonal and meridional gust components are bivariate gamma distributed. An analytical method for testing for bivariate gamma distributed variables is presented. Two distributions for gust modulus are described and the results of extensive hypothesis testing of one of the distributions are presented. The validity of the gamma distribution for representation of gust component variables is established.

Adelfang, S. I.↗