Search NASA⌕ Search

SEARCH · Search NASA

Results for “WAVE REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Quantitative reflectance spectroscopy of buddingtonite from the Cuprite mining district, Nevada

Buddingtonite, an ammonium-bearing feldspar diagnostic of volcanic-hosted alteration, can be identified and, in some cases, quantitatively measured using short-wave infrared (SWIR) reflectance spectroscopy. In this study over 200 samples from Cuprite, Nevada, were evaluated by X ray diffraction, chemical analysis, scanning electron microscopy, and SWIR reflectance spectroscopy with the objective of developing a quantitative remote-sensing technique for rapid determination of the amount of ammonium or buddingtonite present, and its distribution across the site. Based upon the Hapke theory of radiative transfer from particulate surfaces, spectra from quantitative, physical mixtures were compared with computed mixture spectra. We hypothesized that the concentration of ammonium in each sample is related to the size and shape of the ammonium absorption bands and tested this hypothesis for samples of relatively pure buddingtonite. We found that the band depth of the 2.12-micron NH4 feature is linearly related to the NH4 concentration for the Cuprite buddingtonite, and that the relationship is approximately exponential for a larger range of NH4 concentrations. Associated minerals such as smectite and jarosite suppress the depth of the 2.12-micron NH4 absorption band. Quantitative reflectance spectroscopy is possible when the effects of these associated minerals are also considered.

Felzer, Benjamin↗

On the Theory of Acoustic Sounding of Tubular Channels Containing Depressurization Portions

A study is made of the evolution of pressure perturbations that propagate in a tubular channel filled with liquid or gas and having a damaged portion in the form of fairly large slots when their hydraulic resistance is minor. For this purpose, the authors have adopted a mathematical model taking account of viscous friction and of the transfer of heat in a thin layer of the liquid (or the gas) near the wall. Based on this model, dispersion relations have been obtained for the processes of propagation and reflection of harmonic waves from the damaged portion. An analysis has been made of the dependences of the phase velocity, the attenuation factor, and also the coefficients of reflection and transmission on the circular frequency, the physical properties of the liquid or the gas, and also the size of damage. The authors have presented results illustrating the dynamics of pulsed signals as a function of the distance to the damaged portion from the inlet cross section of the channel, the damage scale, and of the form of the medium (liquid or a gas) in the channel.

42 ENGINEERING↗

Analyzing LF/VLF Lightning Waveforms to Estimate D-region Electron Density Profiles

Lightning waveforms in the low frequency (LF; 30-300 kHz) and the very low frequency (VLF; 3-30 kHz) bands can be exploited to produce data-driven ionospheric D-region electron density profile (EDP) estimates with significantly higher spatial and temporal coverage than previously available. The lightning waveforms used in this paper are signals detected in the LF/VLF of negative cloud-to-ground lightning by the Earth Networks Total Lightning Detection Network. Each waveform contains a ground wave and a time-delayed ionospheric reflection. The time delay between the ground wave and ionospheric reflection has previously been used to estimate a single specular reflection altitude, where LF/VLF emissions are reflected by the ionosphere. Here, we expand upon previous methods to include filtering and spectral analysis, and account for oblique propagation to produce higher-order estimates for reflection altitudes and corresponding electron densities. Once estimated, reflection altitudes and corresponding electron densities can be used to derive parameters β and h’, which define an EDP for the D-region. In this study, the lightning waveform (LW) analysis is demonstrated using a single representative 24-hour dataset over the Southeast United States, and then extended to a total of 10 separate datasets with varying locations and ionospheric conditions. The LW-derived D-region EDPs are in agreement with predictions made by the Faraday International Reference Ionosphere model, and the LW EDPs β and h’ values are consistent with previous LF/VLF-derived estimates.

D-region ionosphere↗

SOLAR AURORAS

This paper deals with the acceleration of high-energy flare electrons by field-parallel electric fields in an approach tailored after the auroral acceleration process. Electromagnetic energy, derived from the release of magnetic shear stresses, is converted into kinetic energy of particles. The stress release is enabled by field-aligned potential drops generated by anomalous resistivity of highly filamentary currents. The high-energy flare electrons are identified with runaway particles of this process. The magnetic shear stresses originate from Alfven waves emitted from high-beta loop-top plasma which is produced by braking of the outflow from a reconnection site higher up in the corona. Partial reflection of the waves at the interface to the chromosphere leads to evaporation of chromospheric plasma and creation of a strongly filamentary structure in the sheared coronal field. The energy conversion process propagates spontaneously, like an erosion process in three dimensions. The overall stress release site forms a thin triangular sheet growing along and perpendicular to the field. After about one second, its cross-section perpendicular to B has grown to tens of square kilometers. This spontaneous growth strongly alleviates the demands on the primary filamentary structure posed by the condition of current criticality. Energy flux and mean energy are of the magnitude typical for hard X-rays producing electrons. Their strong dependence on the ambient magnetic field in combination with the fast propagation of the energy conversion sites could lead to energy-dependent time delays of a few 100 ms, much longer than the time-of-flight effects of the electrons.

79 ASTRONOMY AND ASTROPHYSICS↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Scattering of plane guided waves obliquely incident on straight features

A semi-analytical finite element model is developed to study the scattering of plane guided waves obliquely incident on a straight geometric feature. The model is first used to investigate the reflection of the S0 mode from a free edge and the results are compared to those of bulk waves reflecting from a free boundary. The model is then used to predict the transmission of the S0 mode past an adhesively-bonded stiffener. The results obtained are in excellent agreement with experimental measurements.

42 ENGINEERING↗

Low-frequency macroscopic instabilities of fully ionized magnetoplasma

Studies are described of low-frequency quasi-static instabilities in a fully ionized plasma. The plasma is assumed to be immersed in a uniform magnetic field, and is either uniform or has a number density gradient perpendicular to the magnetic field. A moment equation description of the ion and electron dynamics is used; collisions are assumed to have a strong effect on electron motion along the magnetic field. Before considering specific modes, a stability analysis is developed which allows a classification of wave growth characteristics to be made for a bounded system from solutions to the dispersion relation for an infinite system. Also, a method is given for calculating the normal mode frequencies and wave profiles by using the reflection coefficients at the boundaries. For wave propagation perpendicular to the magnetic field, the flute wave is studied in cylindrical geometry. The destabilizing effect of a radial electric field is considered by solving a differential equation.

Rognlien, T. D.↗

Assessment of numerical methods for the solution of fluid dynamics equations for nonlinear resonance systems

The capability of accurate nonlinear flow analysis of resonance systems is essential in many problems, including combustion instability. Classical numerical schemes are either too diffusive or too dispersive especially for transient problems. In the last few years, significant progress has been made in the numerical methods for flows with shocks. The objective was to assess advanced shock capturing schemes on transient flows. Several numerical schemes were tested including TVD, MUSCL, ENO, FCT, and Riemann Solver Godunov type schemes. A systematic assessment was performed on scalar transport, Burgers' and gas dynamic problems. Several shock capturing schemes are compared on fast transient resonant pipe flow problems. A system of 1-D nonlinear hyperbolic gas dynamics equations is solved to predict propagation of finite amplitude waves, the wave steepening, formation, propagation, and reflection of shocks for several hundred wave cycles. It is shown that high accuracy schemes can be used for direct, exact nonlinear analysis of combustion instability problems, preserving high harmonic energy content for long periods of time.

Przekwas, A. J.↗

Wind-Driven Angular Dependence of Sea-Surface Reflectance Measured with an Airborne Doppler Lidar

The effects of wind-stress on the optical properties of the ocean surface have been studied for several decades. In particular, the classic study by Cox and Munk (1954) linking sea-surface wind field to wave slope statistics provides a phenomenology by which the sea-surface wind velocity can be estimated from direct measurement of the wave-modulated surface reflectance. A limited number of studies along these lines have been conducted using airborne or spaceborne lidar systems. In these instances, truthing was provided by in situ ship reports or satellite microwave remote sensing instruments (e.g., ERS scatterometer, SSM/I). During the second deployment of the MACAWS Doppler wind lidar in the summer of 1996 measurements of sea-surface reflectance as a function of azimuth- and nadir-viewing angles were acquired off the California coast. MACAWS data products include directly measured winds, as well as calibrated backscatter/reflectance profiles, thus enabling comparison of the winds inferred from sea-surface reflectance measurements with those deriving from the Doppler-processed direct line-of-sight (LOS) estimates. Additional validation data was extracted from the ERS and SSM/I satellite microwave sensor archives maintained by the JPL Physical Oceanography Distributed Active Archive Center (PO- DAAC).

Tratt, David M.↗

Waves in Plasmas

Quadratic corrections to the metaplectic formulation of mode conversions. In this work we showed how to systematically deal with quadratic corrections beyond the usual linearization of the dispersion matrix at a conversion. The linearization leads to parabolic cylinder functions as the local approximation to the full-wave behavior, but these do not include the variation in amplitude associated with ray refraction in the neighborhood of the conversion. Hence, the region over which they give a good fit to the incoming and outgoing WKB solutions is small. By including higher order corrections it is possible to provide a much more robust matching. We also showed that it was possible, in principle, to extend these methods to arbitrary order. A new normal form for mode conversion. This is based upon our earlier NSF-DOE-funded work on ray helicity. We have begun efforts to apply these new ideas in practical ray tracing algorithms. Group theoretical foundation of path integrals and phase space representations of wave problems. Using the symbol theory of N. Zobin, we developed a new understanding of path integrals on phase space. The initial goal was to find practical computational tools for dealing with non-standard mode conversions. Along the way we uncovered a new way to represent wave functions directly on phase space without the intermediary of a Wigner function. We are exploring the use of these ideas for numerical studies of conversion, with the goal of eventually incorporating kinetic effects. Wave packet studies of gyroresonance crossing. In earlier work, Huanchun Ye and Allan Kaufman -- building upon ideas due to Lazar Friedland -- had shown that gyroresonance crossings could be treated as a double conversion. This perspective is one we have used for many of our papers since then. We are now performing a detailed numerical comparison between full-wave and ray tracing approaches in the study of minority-ion gyroresonance crossing. In this study, a fast magnetosonic wave -- supported by a majority-ion species such as deuterium -- crosses the resonance layer associated with a minority species, such as hydrogen. By using wave packets instead of harmonic solutions, it becomes easy to see the evolution in k-space of the minority-ion disturbance, and the time delay for emission of the reflected fast-wave packet. Iterated conversion in a cavity. When mode conversion occurs in a cavity where rays are trapped, multiple conversions will occur and the resulting absorption profile will typically have a complicated spatial dependence due to overlapping interference patterns. The goal of this work is to develop fast and efficient ray-based methods for computing the cavity response to external driving, and to compute the spatial absorption profile. We have introduced a new approach that allows us to visualize in great detail the underlying iterated ray geometry, and should lead to simpler methods for identifying parameter values where global changes occur in the qualitative response (e.g. global bifurcations).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relating terrestrial atmospheric circulation to solar disturbances

Presented are models of two proposed mechanisms for transferring angular momentum from ionospheric heights to the vicinity of the tropopause. The first mechanism consist of a vicious coupling of the upper atmosphere to the troposphere and the second requires changes in the reflection of planetary waves by the thermosphere. This second mechanism is very appealing because it makes use only of energy derived from the lower atmosphere itself, with solar activity directly modifying only the thermospheric reflectivity.

Hines, C. O.↗

Traveling and standing waves in binary-fluid convection in finite geometries

The effect of finite geometry on the competition between traveling waves and standing waves in systems with a Hopf bifurcation to a state with spatial structure is considered in the linear and weakly nonlinear regimes. The spatial structure observed by Kolodner et al. (1986) in binary-fluid convection is explained in terms of the reflection of the linear traveling waves. The reflection coefficient is calculated, and is found to go to zero as the frequency of the waves becomes small. The pattern expected in a saturated nonlinear state is discussed.

Cross, M. C.↗

Infrasonic directivity of monopole, dipole and bipole ground-surface reflected sources

Infrasound (acoustic waves below 20 Hz) can be used to detect, locate and quantify activity in the atmosphere such as volcanic eruptions and anthropogenic explosions. Attempts to quantify volcanic eruption parameters such as exit velocity, plume height and mass flow rate using infrasound data depend strongly on assumptions of the acoustic source type. Infrasonic sources may produce omnidirectional or directional wavefields, while propagation effects, such as interaction with topography, can induce further wavefield directivity that is measured by field instrumentation. Limited sampling of these wavefields can hinder our ability to infer the underlying source, and thus our understanding of the eruption characteristics. Equivalent sources are often used to represent acoustic source mechanisms and resultant wavefields. In this study, we review equivalent acoustic sources as they pertain to infrasonic scale and wavelengths commonly encountered in very local (⁠<5 km range) geophysical field deployments. We highlight the equivalent infrasonic bipole source that can be induced by ground-reflection of an elevated monopole; we are not aware of any prior infrasound studies that use the bipole source concept. We use analytical and numerical methods to explore source directivity of monopole, dipole and bipole ground-reflected sources at infrasonic frequencies as well as the additional directivity complications introduced by interactions with topography. We illustrate that for typical volcano-infrasound wavelengths, increasing height above the ground as well as increasing source frequency leads to increased wavefield directivity. Numerical modelling using a simple omnidirectional monopole source embedded in topography further illustrates that both horizontal and vertical infrasound directionality can be induced by topography at the distance scales appropriate for local volcano infrasound monitoring. Information summarized in this analytical and numerical exploration of infrasound directivity may be used to help guide future volcano-infrasound field deployments intended to estimate source parameters or quantify wavefield directivity. Analytic solutions for simple whole-space or half-space atmospheres provide useful formulations for planning or initially analysing geophysical field-scale experimental data; however, especially at very local distances from the source (⁠<5 km), 3-D simulations are necessary to account for complex topography commonly encountered in volcano-infrasound applications.

Infrasound↗