Arterial gas occlusions in operating heat pipes

The effect of noncondensable gases on high performance arterial heat pipes has been investigated both analytically and experimentally. Models have been generated which characterize the dissolution of gases in condensate and the diffusional loss of dissolved gases from condensate in arterial flow. These processes, and others, have been used to postulate stability criteria for arterial heat pipes. Experimental observations of gas occlusions were made using a stainless steel heat pipe equipped with viewing ports, and the working fluids methanol and ammonia with the gas additives helium, argon, and xenon. Observations were related to gas transport models.

Saaski, E. W.↗

Design of a heat pipe governed thermal control system for the Solar Electric Propulsion Stage /SEPS/

A 2200-w capacity spacecraft heat rejection system designed for the SEPS and utilizing heat pipe radiator panels has been investigated. The total thermal control system consists of two radiator panels connected to the heat source by variable conductance heat pipes (VCHP's). The system was designed to operate in the 223 to 333 temperature range. The radiators have an emittance of 0.88 at their operational temperature and a fin efficiency of approximately 80 percent. The radiators are thermally isolated from the SEPS and environment by multilayer insulation and thermal shields. Butane was selected as the working fluid for the VCHP because of its low freezing point (135), which is necessary to prevent diffusion freezeout of the liquid during the cold outbond missions. Helium was selected for the control gas. This paper describes the VCHP system, discusses the system design parameters and presents the results of the analyses.

Ruttner, L. E.↗

The UF6 Breeder - A solution to the problems of nuclear power

One of the major advantages of uranium hexafluoride reactors for power generation is the simplified fuel reprocessing scheme which the gaseous fuel makes possible. Critical experiments related to the development of the reactors for electric power generation are discussed along with UF6 breeder reactor studies. Previous energy conversion studies are reported, taking into account gas turbine power plants, thermionic conversion, and MHD conversion. Thermodynamic cycle analyses show that high efficiencies can be achieved using UF6 as the working fluid for Rankine or Brayton cycles without requiring excessive temperatures.

Williams, J. R.↗

Jet pump assisted artery

A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

Source record↗

Preliminary evaluation of a heat pipe heat exchanger on a regenerative turbofan

A preliminary evaluation was made of a regenerative turbofan engine using a heat pipe heat exchanger. The heat exchanger had an effectiveness of 0.70, a pressure drop of 3 percent on each side, and used sodium for the working fluid in the stainless steel heat pipes. The engine was compared to a reference turbofan engine originally designed for service in 1979. Both engines had a bypass ratio of 4.5 and a fan pressure ratio of 2.0. The design thrust of the engines was in the 4000 N range at a cruise condition of Mach 0.98 and 11.6 km. It is shown that heat pipe heat exchangers of this type cause a large weight and size problem for the engine. The penalties were too severe to be overcome by the small uninstalled fuel consumption advantage. The type of heat exchanger should only be considered for small airflow engines in flight applications. Ground applications might prove more suitable and flexible.

Kraft, G. A.↗

Milestone report TCTP application to the SSME hydrogen system analysis

The Transient Cryogen Transfer Computer Program (TCTP) developed and verified for LOX systems by analyses of Skylab S-1B stage loading data from John F. Kennedy Space Center launches was extended to include hydrogen as the working fluid. The feasibility of incorporating TCTP into the space shuttle main engine dynamic model was studied. The program applications are documented.

Richards, J. S.↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

Groll, M.↗

Turbulent boundary layer on a full-coverage film-cooled surface: An experimental heat transfer study with normal injection

Heat transfer behavior was studied in a turbulent boundary layer with full-coverage film cooling through an array of discrete holes and with injection normal to the wall surface. Stanton numbers were measured for a staggered hole pattern with pitch-to-diameter ratios of 5 and 10, an injection mass flux ratio range of 0.1 to 1.0, and a range of Reynolds number 170 thousand to 5 million. Air was used as the working fluid with the mainstream velocity varied from .14 to 33.5 m/sec (30 to 110 ft/sec). The data were taken for secondary injection temperatures equal to the wall temperature and also equal to the mainstream temperature. By use of linear superposition theory, the data may be used to obtain Stanton number as a continuous function of the injectant temperature. The heat transfer coefficient is defined on the basis of a mainstream-to-wall temperature difference. This difinition permits direct comparison of performance between film cooling and transpiration cooling.

Choe, H.↗

Full-coverage film cooling heat transfer study: Summary of data for normal-hole injection and 30 deg slant-hole injection

Heat transfer to a full coverage film cooled turbulent boundary layer over a flat surface was studied. The surface consisted of a discrete hole test section containing 11 rows of holes spaced 5 diameters apart in a staggered array and an instrumented recovery region. Ten diameter spacing was also studied by plugging appropriate holes. Two test sections were used, one having holes normal to the surface and the other having holes angled 30 deg to the surface in the downstream direction. Stanton number data were obtained both in the full coverage region and in the downstream recovery region for a range of blowing ratios, or mass flux ratios, from 0 to 1.3. Initial conditions at the upstream edge of the blowing region were varied from 500 to 5000 for momentum thickness Reynolds number and from 100 to 1800 for enthalpy thickness Reynolds number. The range of Reynolds numbers based on hole diameter and mainstream velocity was 6000 to 22000. Initial boundary layer thicknesses range from 0.5 to 2.0 hole diameters. Air was used as the working fluid. The data were taken for the secondary injection temperature equal to the wall temperature and also equal to the mainstream temperature. Superposition was then used to obtain Stanton number as a continuous function of the injectant temperature. The heat transfer coefficient was defined on the basis of a mainstream-to-wall temperature difference. This definition permits direct comparison of performance between film cooling and transpiration cooling.

Crawford, M. E.↗

Prediction of cryogenic heat pipe performance

A 304 stainless steel heat pipe with slab type capillary structure and nitrogen as the working fluid was studied in the temperature range of 60 K to 120 K. The pipe was 1.27 cm in outside diameter and 9.14 cm in total length. In the transient studies, described in detail in this report, saddles were included at evaporator and condenser ends and a radiator was included at the condenser end.

Colwell, G. T.↗

Heat pipe temperature control utilizing a soluble gas absorption reservior

A new gas-controlled heat pipe design is described which uses a liquid matrix reservior, or sponge, to replace the standard gas reservior. Reservior volume may be reduced by a factor of five to ten for certain gas-liquid combinations, while retaining the same level of temperature control. Experiments with ammonia, butane, and carbon dioxide control gases with methanol working fluid are discussed.

Saaski, E. W.↗

A dynamic pressure source for the calibration of pressure transducers

A dynamic pressure source is described for producing sinusoidally varying pressures of up to 34 kPa zero to peak, over the frequency range of approximately 50 Hz to 2 kHz. The source is intended for the dynamic calibration of pressure transducers. The transducer to be calibrated is mounted near the base of the thick walled aluminum tube forming the vessel so that the pressure sensitive element is in contact with the liquid in the tube. A section of the tube is filled with small steel balls to damp the motion of the 10-St dimethyl siloxane working fluid in order to extend the useful frquency range to higher frequencies than would be provided by an undamped system. The dynamic response of six transducers provided by the sponsor was evaluated using the pressure sources; the results of these calibrations are given.

Vezzetti, C. F.↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick was extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: maximum heat pipe performance as a function of fluid inventory, maximum performance as a function of operating temperature, maximum performance as a function of evaporator elevation, and influence of slab wick orientation on performance. The experimental data were compared with theoretical predictions obtained with the GRADE computer program.

Groll, M.↗

Application of axial grooves to cryogenic variable conductance heat pipe technology

Tests results obtained with an ATS axial groove aluminum extrusion adapted for use as a cryogenic thermal diode and/or a variable conductance heat pipe are presented. Ethane at a nominal operating temperature of 185 C was used as working fluid. In addition to both active and passive gas control, diode designs utilizing gas blockage or liquid trap were investigated. Specific requirements and performance parameters such as transient behavior, reservoir sizes, shutdown energy, etc., were evaluated. Results are also presented for tests where the liquid trap was used as a secondary heat pipe to demonstrate thermal switching with simultaneous heat pipe operation and diode shutdown.

Brennan, P. J.↗

Performance characteristics of rotating wickless heat pipes

A theoretical model was derived for laminar film condensation on the inside of a rotating, truncated cone which includes the effects of vapor shear and vapor pressure drop. Results are compared to those of previous investigations. Experimental data are presented for rotational speeds of 700, 1,400, 2,100, and 2,800 rpm using water, ethyl alcohol, and Freon 113 as working fluids. Agreement between theory and experiment is within + or - 20 percent.

Marto, P. J.↗

Investigation of applications for high-power, self-critical fissioning uranium plasma reactors

Analytical studies were conducted to investigate potentially attractive applications for gaseous nuclear cavity reactors fueled by uranium hexafluoride and its decomposition products at temperatures of 2000 to 6000 K and total pressures of a few hundred atmospheres. Approximate operating conditions and performance levels for a class of nuclear reactors in which fission energy removal is accomplished principally by radiant heat transfer from the high temperature gaseous nuclear fuel to surrounding absorbing media were determined. The results show the radiant energy deposited in the absorbing media may be efficiently utilized in energy conversion system applications which include (1) a primary energy source for high thrust, high specific impulse space propulsion, (2) an energy source for highly efficient generation of electricity, and (3) a source of high intensity photon flux for heating working fluid gases for hydrogen production or MHD power extraction.

Rodgers, R. J.↗

Heat transfer to a full-coverage film-cooled surface with 30 degree slant-hole injection

Heat transfer behavior was studied in a turbulent boundary layer with full coverage film cooling through an array of discrete holes and with injection 30 deg to the wall surface in the downstream direction. Stanton numbers were measured for a staggered hole pattern with pitch-to-diameter ratios of 5 and 10, an injection mass flux ratio range of 0.1 to 1.3, and a range of Reynolds number Re sub x of 150,000 to 5 million. Air was used as the working fluid, and the mainstream velocity varied from 9.8 to 34.2 m/sec (32 to 112 ft/sec). The data were taken for secondary injection temperature equal to the wall temperature and also equal to the mainstream temperature. The data may be used to obtain Stanton number as a continuous function of the injectant temperature by use of linear superposition theory. The heat transfer coefficient is defined on the basis of a mainstream-to-wall temperature difference. This definition permits direct comparison of performance between film cooling and transpiration cooling. A differential prediction method was developed to predict the film cooling data base. The method utilizes a two-dimensional boundary layer program with routines to model the injection process and turbulence augmentation. The program marches in the streamwise direction, and when a row of holes is encountered, it stops and injects fluid into the boundary layer. The turbulence level is modeled by algebraically augmenting the mixing length, with the augmentation keyed to a penetration distance for the injected fluid.

Crawford, M. E.↗

Two-phase turbine engines

A description is given of a two-phase turbine which utilizes a uniform mixture of gas and liquid accelerated in nozzles of the types reported by Elliott and Weinberg (1968). The mixture acts directly on an axial flow or tangential impulse turbine or is separated into gas and liquid streams which operate separately on a gas turbine and a hydraulic turbine. The basic two-phase cycles are examined, taking into account working fluids, aspects of nozzle expansion, details of turbine cycle operation, and the effect of mixture ratio variation. Attention is also given to two-phase nozzle efficiency, two-phase turbine operating characteristics and efficiencies, separator turbines, and impulse turbine experiments.