Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Demonstration of neutron time-of-flight diffraction with an event-mode imaging detector

Neutron diffraction beamlines have traditionally relied on deploying large detector arrays of 3 He tubes or neutron-sensitive scintillators coupled with photomultipliers to efficiently probe crystallographic and microstructure information of a given material. Given the large upfront cost of custom-made data acquisition systems and the recent scarcity of 3 He, new diffraction beamlines or upgrades to existing ones demand innovative approaches. This paper introduces a novel Timepix3-based event-mode imaging neutron diffraction detector system as well as first results of a silicon powder diffraction measurement made at the HIPPO neutron powder diffractometer at the Los Alamos Neutron Science Center. Notably, these initial measurements were conducted simultaneously with the 3 He array on HIPPO, enabling direct comparison. Data reduction for this type of data was implemented in the MAUD code, enabling Rietveld analysis. Results from the Timepix3-based setup and HIPPO were benchmarked against McStas simulations, showing good agreement for peak resolution. With further development, systems such as the one presented here may substantially reduce the cost of detector systems for new neutron instrumentation as well as for upgrades of existing beamlines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Planar Two-Dimensional Superconducting Bolometer Array for the Green Bank Telescope

In order to provide high sensitivity rapid imaging at 3.3mm (90GHz) for the Green Bank Telescope - the world's largest steerable aperture - a camera is being built by the University of Pennsylvania, NASA/GSFC, and NRAO. The heart of this camera is an 8x8 close-packed, Nyquist-sampled detector array. We have designed and are fabricating a functional superconducting bolometer array system using a monolithic planar architecture. Read out by SQUID multiplexers, the superconducting transition edge sensors will provide fast, linear, sensitive response for high performance imaging. This will provide the first ever superconducting bolometer array on a facility instrument.

Benford, Dominic↗

Coherent optical array receiver experiment : design, implementation and BER performance of a multichannel coherent optical receiver for PPM signals under atmospheric turbulence

The performance of a coherent free-space optical communication system operating in the presence of turbulence is investigated. Maximum Likelihood Detection techniques are employed to optimally detect Pulse Position Modulated signals with a focal-plane detector array, and reconstruct the turbulence-degraded signals. The experimental demonstration of this project and results may be divided in three parts; two of which have already been explained in previous publications (1,2). This latest paper shows the final experimental results, including investigation of performance of the Coherent Optical Receiver Experiment (CORE) performed at the laboratory facilities at JPL. Bit Error Rate (BER) is presented for single and multichannel optical receivers, where quasi-shot noise limited performance is achieved, under simulated turbulence conditions using non-coherent post-detection processing techniques.

Hassibi, Babak↗

On the possibility to discriminate the mass of the primary cosmic ray using the muon arrival times from extensive air showers: Application for Pierre Auger Observatory

In this paper we study the possibility to discriminate the mass of the primary cosmic ray by observing the muon arrival times in ground detectors. We analyzed extensive air showers (EAS) induced by proton and iron nuclei with the same energy 8 Multiplication-Sign 10{sup 17} eV simulated with CORSIKA, and analyzed the muon arrival times at ground measured by the infill array detectors of the Pierre Auger Observatory (PAO). From the arrival times of the core and of the muons the atmospheric depth of muon generation locus is evaluated. The results suggest a potential mass discrimination on the basis of muon arrival times and of the reconstructed atmospheric depth of muon production. An analysis of a larger set of CORSIKA simulations carried out for primary energies above 10{sup 18} eV is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the spatial resolution of an online dose verification device

Purpose: The aim of this work is to characterize a new online dose verification device, COMPASS transmission detector array (IBA Dosimetry, Schwarzenbruck, Germany). The array is composed of 1600 cylindrical ionization chambers of 3.8 mm diameter, separated by 6.5 mm center-to-center spacing, in a 40 x 40 arrangement. Methods: The line spread function (LSF) of a single ion chamber in the detector was measured with a narrow slit collimator for a 6 MV photon beam. The 0.25 x 10 mm{sup 2} slit was formed by two machined lead blocks. The LSF was obtained by laterally translating the detector in 0.25 mm steps underneath the slit over a range of 24 mm and taking a measurement at each step. This measurement was validated with Monte Carlo simulation using BEAMnrc and DOSXYZnrc. The presampling modulation transfer function (MTF), the Fourier transform of the line spread function, was determined and compared to calculated (Monte Carlo and analytical) MTFs. Two head-and-neck intensity modulated radiation therapy (IMRT) fields were measured using the device and were used to validate the LSF measurement. These fields were simulated with the BEAMnrc Monte Carlo model, and the Monte Carlo generated incident fluence was convolved with the 2D detector response function (derived from the measured LSF) to obtain calculated dose. The measured and calculated dose distributions were then quantitatively compared using {chi}-comparison criteria of 3% dose difference and 3 mm distance-to-agreement for in-field points (defined as those above the 10% maximum dose threshold). Results: The full width at half-maximum (FWHM) of the measured detector response for a single chamber is 4.3 mm, which is comparable to the chamber diameter of 3.8 mm. The pre-sampling MTF was calculated, and the resolution of one chamber was estimated as 0.25 lp/mm from the first zero crossing. For both examined IMRT fields, the {chi}-comparison between measured and calculated data show good agreement with 95.1% and 96.3% of in-field points below {chi} of 1.0 for fields 1 and 2, respectively (with an average {chi} of 0.29 for IMRT field 1 and 0.24 for IMRT field 2). Conclusions: The LSF for a new novel online detector has been measured at 6 MV using a narrow slit technique, and this measurement has been validated by Monte Carlo simulation. The detector response function derived from line spread function has been applied to recover measured IMRT fields. The results have shown that the device measures IMRT fields accurately within acceptable tolerance.

61 RADIATION PROTECTION AND DOSIMETRY↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept

The Astrobiology Explorer (ABE) is a MIDEX mission concept under study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp. ABE will conduct IR spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Cassegrain telescope and two moderate resolution (R = 2000-3000) spectrographs covering the 2.5-16 micron spectral region. Large format (1024x 1024 pixel or larger) IR detector arrays and bandpass filters will allow each spectrograph to cover an entire octave of spectral range or more per exposure without any moving parts. The telescope will be cooled below 50K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approximately 8K. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approximate 1-2 year mission lifetime.

Ennico, Kimberly↗

Downlink Receiver Algorithms for Deep Space Optical Communications

The goal of the Deep Space Optical Communications project at the Jet Propulsion Laboratory is to demonstrate laser communication links at ranges out to approximately 3 AU. In this paper, we discuss a downlink receiver concept capable of demodulating optical pulse-position modulated (PPM) waveforms with data rates varying from approximately 50 kbps up to 265 Mbps, using a range of PPM orders, slot widths, and code rates. The receiver operates on recorded timestamps corresponding to the times-of-arrival of photons detected by a photon-counting detector array followed by a commercial time-tagger. Algorithms are presented for slot, symbol, and frame synchronization as well as parameter estimation. Estimates of link performance are evaluated through Monte- Carlo simulation for an optical channel that includes optical losses, detector blocking, signal clock dynamics, and pointing-induced downlink fades. Based upon these simulation results, it is expected that link closure may be achieved with at least 3 dB of margin under a variety of relevant conditions.

Tkacenko, Andre↗

A whole-system approach to x-ray spectroscopy in cargo inspection systems

The bremsstrahlung x-ray spectrum used in high-energy, high-intensity x-ray cargo inspection systems is attenuated and modified by the materials in the cargo in a Z-dependent way. Therefore, spectroscopy of the detected x rays yields information about the Z of the x-rayed cargo material. It has previously been shown that such ZSpectroscopy (Z-SPEC) is possible under certain circumstances. A statistical approach, Z-SCAN (Z-determination by Statistical Count-rate ANalysis), has also been shown to be effective, and it can be used either by itself or in conjunction with Z-SPEC when the x-ray count rate is too high for individual x-ray spectroscopy. Both techniques require fast x-ray detectors and fast digitization electronics. It is desirable (and possible) to combine all techniques, including x-ray imaging of the cargo, in a single detector array, to reduce costs, weight, and overall complexity. In this paper, we take a whole-system approach to x-ray spectroscopy in x-ray cargo inspection systems, and show how the various parts interact with one another. Faster detectors and read-out electronics are beneficial for both techniques. A higher duty-factor x-ray source allows lower instantaneous count rates at the same overall x-ray intensity, improving the range of applicability of Z-SPEC in particular. Using an intensity-modulated advanced x-ray source (IMAXS) allows reducing the x-ray count rate for cargoes with higher transmission, and a stacked-detector approach may help material discrimination for the lowest attenuations. Image processing and segmentation allow derivation of results for entire objects, and subtraction of backgrounds. We discuss R and D performed under a number of different programs, showing progress made in each of the interacting subsystems. We discuss results of studies into faster scintillation detectors, including ZnO, BaF{sub 2} and PbWO{sub 4}, as well as suitable photo-detectors, read-out and digitization electronics. We discuss high-duty-factor linear-accelerator x-ray sources and their associated requirements, and how such sources improve spectroscopic techniques. We further discuss how image processing techniques help in correcting for backgrounds and overlapping materials. In sum, we present an integrated picture of how to optimize a cargo inspection system for x-ray spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-spin structure of Xe 134

Detailed spectroscopic information on the N~82 nuclei is necessary to benchmark shell-model calculations in the region. The nuclear structure above long-lived isomers in 134 Xe is investigated after multinucleon transfer (MNT) and actinide fission. Xenon-134 was populated as (i) a transfer product in 136 Xe+ 238 U and 136 Xe+ 208 Pb MNT reactions and (ii) as a fission product in the 136 Xe+ 238 U reaction employing the high-resolution Advanced Gamma Tracking Array (AGATA). Trajectory reconstruction has been applied for the complete identification of beamlike transfer products with the magnetic spectrometer PRISMA. The 136 Xe+ 198 Pt MNT reaction was studied with the γ-ray spectrometer GAMMASPHERE in combination with the gas detector array Compact Heavy Ion Counter (CHICO). Several high-spin states in 134 Xe on top of the two long-lived isomers are discovered based on γγ-coincidence relationships and information on the γ-ray angular distributions as well as excitation energies from the total kinetic energy loss and fission fragments. The revised level scheme of 134 Xe is extended up to an excitation energy of 5.832 MeV with tentative spin-parity assignments up to 16 + . Previous assignments of states above the 7 - isomer are revised. Latest shell-model calculations employing two different effective interactions reproduce the experimental findings and support the new spin and parity assignments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

100-micron array polarimetry from the Kuiper Airborne Observatory - Instrumentation, techniques, and first results

The University of Chicago far-infrared array polarimeter, 'STOKES', is the first multiple-beam polarimeter for far-infrared astronomy. Observations are made from the NASA Kuiper Airborne Observatory. Two orthogonal components of linear polarization are detected simultaneously by corresponding pairs of bolometers in two 32-detector arrays. Novel observing and data-analysis techniques are used to overcome the inherent difficulties of array polarimetry. Results from the first observing flights with the new instrument are reported for the molecular clouds W3 and W51. The measurements show that the magnetic-field structure in both clouds is nonuniform on the scale of 0.5-1.5 pc. This is consistent with molecular line and Zeeman observations that indicate the presence of turbulent velocities and significant small-scale structure. Preliminary results from the second flight series have yielded approximately 40 new measurements in the Sgr A complex. These results indicate that modifications made since the first flights have significantly improved the performance of STOKES.

Platt, S. R.↗

A Germanium Array for Sample Measurements: Recent Results and New Analysis Methods

ABSTRACT The Pacific Northwest National Laboratory is finalizing construction of a 14-crystal intrinsic germanium (HPGe) array designed for high detection efficiency, ultra-low-background performance, and sensitive gamma gamma coincidence detection. Initial development of a custom software suite capable of automating many of the tasks required to accurately analyze coincident signals within close-geometry detector arrays will also be completed this year. The analysis capability is required to enable rapid interpretation of data collected with the low-background (HPGe) array. The status of final construction of the 2nd cryostat and the complete system will be discussed, as well as measurement results from independent operation of the 1st cryostat. Status of the CASCADES analysis development, including cross-talk correction and new techniques for efficiency calibration, are also presented.

Keillor, Martin E.↗

Bolometer and photosensitive detector systems for IR

In order to achieve the full sensitivity required for future space astronomy applications, IR detector systems will have to be cooled to 0.1 K or less. The feasibility of such cryocooling has been demonstrated for the established laboratory technique of adiabatic demagnetization, and it has been shown that bolometers made from compensated silicon, with ion-implanted contacts, come close to calculated ultimate performance limits. Unlike bolometers, silicon and germanium photoconductors are highly wavelength-dependent. Useful wavelengths are presented for the most promising photodetectors based on these materials. It is noted that, as the relevant microelectronic technology advances, array detectors in the near-IR may be expected to approach the size and performance of large, intrinsic silicon CCD arrays now available for optical wavelengths.

Low, F. J.↗

Characterization of 2.5 microns HgCdTe detectors for low-background applications

A program of testing aimed at the evaluation of systems that have the potential to provide the level of performance required for use in space-based instruments was undertaken and their usefulness appraised for astronomy. The results of the first phase of the program to characterize selected pixels of a HgCdTe photovoltaic array detector were reported.

Depoy, D. L.↗

Evaluation of a 32 x 32 InSb CCD for use in astronomy

We have been fortunate to receive several infrared CCD array detectors on loan from Santa Barbara Research Center. The devices are evaluation samples, not commercially available at this time. Dr. Alan Hoffman of SBRC has made the arrangements for this loan and provided considerable technical support to this project. One aim of this project has been to evaluate the performance potential of this array technology, using astronomical objects. A quick summary of our findings is given. In short, we have found the imaging properties to be excellent under both low and high background conditions and the sensitivity to be quite good (each pixel is competitive with current InSb single-detector systems in use for astronomy). We anticipate improved low-background performance when we run these detectors at a lower and more stable temperature. The device characteristics are described, laboratory testing is summarized, and the first astronomical imaging is presented. Various circuits developed (clocks, clock drivers, DC supplies, clamp-amplifier, and a real time display system) are given.

Forrest, W. J.↗

Cryogenic light detectors with thermal signal amplification for 0 νββ search experiments

As a step towards the realization of cryogenic-detector experiments to search for neutrinoless double-beta decay (such as CROSS, BINGO, and CUPID), we investigated a batch of 10 Ge light detectors (LDs) assisted by Neganov-Trofimov-Luke (NTL) signal amplification. Each LD was assembled with a large cubic light-emitting crystal (45 mm side) using the recently developed CROSS mechanical structure. The detector array was operated at milli-Kelvin temperatures in a pulse-tube cryostat at the Canfranc underground laboratory in Spain. We achieved good performance with scintillating bolometers from CROSS, made of Li 2 100 MoO 4 crystals and used as reference detectors of the setup, and with all LDs tested (except for a single device that encountered an electronics issue). No leakage current was observed for 8 LDs with an electrode bias up to 100 V. Operating the LDs at an 80 V electrode bias applied in parallel, we obtained a gain of around 9 in the signal-to-noise ratio of these devices, allowing us to achieve a baseline noise RMS of O(10 eV). Thanks to the strong current polarization of the temperature sensors, the time response of the devices was reduced to around half a millisecond in rise time. The achieved performance of the LDs was extrapolated via simulations of pile-up rejection capability for several configurations of the CUPID detector structure. Despite the sub-optimal noise conditions of the LDs (particularly at high frequencies), we demonstrated that the NTL technology provides a viable solution for background reduction in CUPID.

47 OTHER INSTRUMENTATION↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive two-pass cone-beam artifact correction using a FOV-preserving two-source geometry: A simulation study

The evolution to ever wider detector arrays that are able to cover whole organs with a single circular gantry sweep has revitalized the research efforts toward finding improved axial scanning algorithms and protocols. The authors propose a computed tomography scan and reconstruction concept using two sources, a single detector and a two-pass cone-beam correction method, as an integral part of the reconstruction. Compared with standard circular acquisition and reconstruction methods, the new concept excels with improved coverage and very low cone-beam artifact level also for short scan acquisitions, which makes it especially attractive for cardiac applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Performance of the Muon Monitor for the T2K Neutrino Oscillation Experiment

This article describes the design and performance of the muon monitor for the T2K (Tokaito-Kamioka) long baseline neutrino oscillation experiment. The muon monitor consists of two types of detector arrays: ionization chambers and silicon PIN photodiodes. It measures the intensity and profile of muons produced, along with neutrinos, in the decay of pions. The measurement is sensitive to the intensity and direction of the neutrino beam. The linearity and stability of the detectors were measured in beam tests to be within 2.4% and 1.5%, respectively. Based on the test results, the precision of the beam direction measured by the muon monitor is expected to be 0.25 mrad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗