Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Offline multiple adaptive planning strategy for concurrent irradiation of the prostate and pelvic lymph nodes

Purpose: Concurrent irradiation of the prostate and pelvic lymph nodes (PLNs) can be challenging due to the independent motion of the two target volumes. To address this challenge, the authors have proposed a strategy referred to as Multiple Adaptive Planning (MAP). To minimize the number of MAP plans, the authors’ previous work only considered the prostate motion in one major direction. After analyzing the pattern of the prostate motion, the authors investigated a practical number of intensity-modulated radiotherapy (IMRT) plans needed to accommodate the prostate motion in two major directions simultaneously. Methods: Six patients, who received concurrent irradiation of the prostate and PLNs, were selected for this study. Nine MAP-IMRT plans were created for each patient with nine prostate contours that represented the prostate at nine locations with respect to the PLNs, including the original prostate contour and eight contours shifted either 5 mm in a single anterior-posterior (A-P), or superior-inferior (S-I) direction, or 5 mm in both A-P and S-I directions simultaneously. From archived megavoltage cone beam CT (MV-CBCT) and a dual imaging registration, 17 MV-CBCTs from 33 available MV-CBCT from these patients showed large prostate displacements (>3 mm in any direction) with respect to the pelvic bones. For each of these 17 fractions, one of nine MAP-IMRT plans was retrospectively selected and applied to the MV-CBCT for dose calculation. For comparison, a simulated isocenter-shifting plan and a reoptimized plan were also created for each of these 17 fractions. The doses to 95% (D95) of the prostate and PLNs, and the doses to 5% (D5) of the rectum and bladder were calculated and analyzed. Results: For the prostate, D95 > 97% of the prescription dose was observed in 16, 16, and 17 of 17 fractions for the MAP, isocenter-shifted, and reoptimized plans, respectively. For PLNs, D95 > 97% of the prescription doses was observed in 10, 3, and 17 of 17 fractions for the three types of verification plans, respectively. The D5 (mean ± SD) of the rectum was 45.78 ± 5.75, 45.44 ± 4.64, and 44.64 ± 2.71 Gy, and the D5 (mean ± SD) of the bladder was 45.18 ± 2.70, 46.91 ± 3.04, and 45.67 ± 3.61 Gy for three types of verification plans, respectively. Conclusions: The MAP strategy with nine IMRT plans to accommodate the prostate motions in two major directions achieved good dose coverage to the prostate and PLNs. The MAP approach can be immediately used in clinical practice without requiring extra hardware and software.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Topological one-way quantum computation on verified logical cluster states

We present a scheme to improve the noise threshold for fault-tolerant topological one-way computation with constant overhead. Certain cluster states of finite size, say star clusters, are constructed with logical qubits through an efficient verification process to achieve high fidelity. Then, the star clusters are connected near-deterministically with verification to form a three-dimensional cluster state to implement topological one-way computation. The necessary postselection for verification is localized within the star clusters, ensuring the scalability of computation. By using the Steane seven-qubit code for the logical qubits, this scheme works with a high error rate of 2% and reasonable resources comparable to or less than those for the other fault-tolerant schemes. A higher noise threshold would be achieved by adopting a larger code.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EOSlib, Version 3

Equilibrium thermodynamics underpins many of the technologies used throughout theoretical physics, yet verification of the various theoretical models in the open literature remains challenging. EOSlib provides a single, consistent, verifiable implementation of these models, in a single, easy-to-use software package. It consists of three parts: a software library implementing various published equation-of-state (EOS) models; a database of fitting parameters for various materials for these models; and a number of useful utility functions for simplifying thermodynamic calculations such as computing Hugoniot curves or Riemann problem solutions. Ready availability of this library will enable reliable code-to- code testing of equation-of-state implementations, as well as a starting point for more rigorous verification work. EOSlib also provides a single, consistent API for its analytic and tabular EOS models, which simplifies the process of comparing models for a particular application.

Woods, Nathan↗

EOSlib, Version 3

Equilibrium thermodynamics underpins many of the technologies used throughout theoretical physics, yet verification of the various theoretical models in the open literature remains challenging. EOSlib provides a single, consistent, verifiable implementation of these models, in a single, easy-to-use software package. It consists of three parts: a software library implementing various published equation-of-state (EOS) models; a database of fitting parameters for various materials for these models; and a number of useful utility functions for simplifying thermodynamic calculations such as computing Hugoniot curves or Riemann problem solutions. Ready availability of this library will enable reliable code-to- code testing of equation-of-state implementations, as well as a starting point for more rigorous verification work. EOSlib also provides a single, consistent API for its analytic and tabular EOS models, which simplifies the process of comparing models for a particular application.

Woods, Nathan↗

Verification of a magnetic island in gyro-kinetics by comparison with analytic theory

A rotating magnetic island is imposed in the gyrokinetic code GKW, when finite differences are used for the radial direction, in order to develop the predictions of analytic tearing mode theory and understand its limitations. The implementation is verified against analytics in sheared slab geometry with three numerical tests that are suggested as benchmark cases for every code that imposes a magnetic island. The convergence requirements to properly resolve physics around the island separatrix are investigated. In the slab geometry, at low magnetic shear, binormal flows inside the island can drive Kelvin-Helmholtz instabilities which prevent the formation of the steady state for which the analytic theory is formulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-83: A Study On Evaluating the Directional Dependency of 2D Seven 29 Ion Chamber Array Clinically with Different IMRT Plans

Purpose: To evaluate the directional dependency of 2D seven 29 ion chamber array clinically with different IMRT plans. Methods: 25 patients already treated with IMRT plans were selected for the study. Verification plans were created for each treatment plan in eclipse 10 treatment planning system using the AAA algorithm with the 2D array and the Octavius CT phantom. Verification plans were done 2 times for a single patient. First plan with real IMRT (plan-related approach) and second plan with zero degree gantry angle (field-related approach). Measurements were performed on a Varian Clinac-iX, linear accelerator equipped with a millennium 120 multileaf collimator. Fluence was measured for all the delivered plans and analyzed using the verisoft software. Comparison was done by selecting the fluence delivered in static gantry (zero degree gantry) versus IMRT with real gantry angles. Results: The gamma pass percentage is greater than 97 % for all IMRT delivered with zero gantry angle and between 95%–98% for real gantry angles. Dose difference between the TPS calculated and measured for IMRT delivered with zero gantry angle was found to be between (0.03 to 0.06Gy) and with real gantry angles between (0.02 to 0.05Gy). There is a significant difference between the gamma analysis between the zero degree and true angle with a significance of 0.002. Standard deviation of gamma pass percentage between the IMRT plans with zero gantry angle was 0.68 and for IMRT with true gantry angle was found to be 0.74. Conclusion: The gamma analysis for IMRT with zero degree gantry angles shows higher pass percentage than IMRT delivered with true gantry angles. Verification plans delivered with true gantry angles lower the verification accuracy when 2D array is used for measurement.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-08: Dual Modality Verification for Respiratory Gating Using New Real- Time Tumor Tracking Radiotherapy System

Purpose: The respirato ry gating system combined the TrueBeam and a new real-time tumor-tracking radiotherapy system (RTRT) was installed. The RTRT system consists of two x-ray tubes and color image intensifiers. Using fluoroscopic images, the fiducial marker which was implanted near the tumor was tracked and was used as the internal surrogate for respiratory gating. The purposes of this study was to develop the verification technique of the respiratory gating with the new RTRT using cine electronic portal image device images (EPIDs) of TrueBeam and log files of the RTRT. Methods: A patient who underwent respiratory gated SBRT of the lung using the RTRT were enrolled in this study. For a patient, the log files of three-dimensional coordinate of fiducial marker used as an internal surrogate were acquired using the RTRT. Simultaneously, the cine EPIDs were acquired during respiratory gated radiotherapy. The data acquisition was performed for one field at five sessions during the course of SBRT. The residual motion errors were calculated using the log files (E{sub log}). The fiducial marker used as an internal surrogate into the cine EPIDs was automatically extracted by in-house software based on the template-matching algorithm. The differences between the the marker positions of cine EPIDs and digitally reconstructed radiograph were calculated (E{sub EPID}). Results: Marker detection on EPID using in-house software was influenced by low image contrast. For one field during the course of SBRT, the respiratory gating using the RTRT showed the mean ± S.D. of 95{sup th} percentile E{sub EPID} were 1.3 ± 0.3 mm,1.1 ± 0.5 mm,and those of E{sub log} were 1.5 ± 0.2 mm, 1.1 ± 0.2 mm in LR and SI directions, respectively. Conclusion: We have developed the verification method of respiratory gating combined TrueBeam and new real-time tumor-tracking radiotherapy system using EPIDs and log files.

60 APPLIED LIFE SCIENCES↗

Cluster-based architecture for fault-tolerant quantum computation

We present a detailed description of an architecture for fault-tolerant quantum computation, which is based on the cluster model of encoded qubits. In this cluster-based architecture, concatenated computation is implemented in a quite different way from the usual circuit-based architecture where physical gates are recursively replaced by logical gates with error-correction gadgets. Instead, some relevant cluster states, say fundamental clusters, are recursively constructed through verification and postselection in advance for the higher-level one-way computation, which namely provides error-precorrection of gate operations. A suitable code such as the Steane seven-qubit code is adopted for transversal operations. This concatenated construction of verified fundamental clusters has a simple transversal structure of logical errors, and achieves a high noise threshold {approx}3% for computation by using appropriate verification procedures. Since the postselection is localized within each fundamental cluster with the help of deterministic bare controlled-Z gates without verification, divergence of resources is restrained, which reconciles postselection with scalability.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-218: Validation of An In-Vivo Proton Range Verification Method for Reducing the Risk of Permanent Alopecia in the Treatment of Pediatric Medulloblastoma

Purpose: The clinical commissioning of a workflow for pre-treatment range verification/adjustment for the head treatment of pediatric medulloblastoma patients, including dose monitoring during treatment. Methods: An array of Si-diodes (DIODES Incorporated) is placed on the patient skin on the opposite side to the beam entrance. A “scout” SOBP beam, with a longer beam range to cover the diodes in its plateau, is delivered; the measured signal is analyzed and the extracted water equivalent path lengths (WEPL) are compared to the expected values, revealing if a range correction is needed. Diodes stay in place during treatment to measure dose. The workflow was tested in solid water and head phantoms and validated against independent WEPL measurements. Both measured WEPL and skin doses were compared to computed values from the TPS (XiO); a Markus chamber was used for reference dose measurements. Results: The WEPL accuracy of the method was verified by comparing it with the dose extinction method. It resulted, for both solid water and head phantom, in the sub-millimeter range, with a deviation less than 1% to the value extracted from the TPS. The accuracy of dose measurements in the fall-off part of the dose profile was validated against the Markus chamber. The entire range verification workflow was successfully tested for the mock-treatment of head phantom with the standard delivery of 90 cGy per field per fraction. The WEPL measurement revealed no need for range correction. The dose measurements agreed to better than 4% with the prescription dose. The robustness of the method and workflow, including detector array, hardware set and software functions, was successfully stress-tested with multiple repetitions. Conclusion: The performance of the in-vivo range verification system and related workflow meet the clinical requirements in terms of the needed WEPL accuracy for pretreatment range verification with acceptable dose to the patient.

60 APPLIED LIFE SCIENCES↗

Neutron Source Facility Training Simulator Based on EPICS

A plant operator training simulator is developed for training the plant operators as well as for design verification of plant control system (PCS) and plant protection system (PPS) for the Kharkov Institute of Physics and Technology Neutron Source Facility. The simulator provides the operator interface for the whole plant including the sub-critical assembly coolant loop, target coolant loop, secondary coolant loop, and other facility systems. The operator interface is implemented based on Experimental Physics and Industrial Control System (EPICS), which is a comprehensive software development platform for distributed control systems. Since its development at Argonne National Laboratory, it has been widely adopted in the experimental physics community, e.g. for control of accelerator facilities. This work is the first implementation for a nuclear facility. The main parts of the operator interface are the plant control panel and plant protection panel. The development involved implementation of process variable database, sequence logic, and graphical user interface (GUI) for the PCS and PPS utilizing EPICS and related software tools, e.g. sequencer for sequence logic, and control system studio (CSS-BOY) for graphical use interface. For functional verification of the PCS and PPS, a plant model is interfaced, which is a physics-based model of the facility coolant loops implemented as a numerical computer code. The training simulator is tested and demonstrated its effectiveness in various plant operation sequences, e.g. start-up, shut-down, maintenance, and refueling. It was also tested for verification of the plant protection system under various trip conditions.

Park, Young Soo↗

SHARP User Manual

SHARP is an advanced modeling and simulation toolkit for the analysis of nuclear reactors. It is comprised of several components including physical modeling tools, tools to integrate the physics codes for multi-physics analyses, and a set of tools to couple the codes within the MOAB framework. Physics modules currently include the neutronics code PROTEUS, the thermal-hydraulics code Nek5000, and the structural mechanics code Diablo. This manual focuses on performing multi-physics calculations with the SHARP ToolKit. Manuals for the three individual physics modules are available with the SHARP distribution to help the user to either carry out the primary multi-physics calculation with basic knowledge or perform further advanced development with in-depth knowledge of these codes. This manual provides step-by-step instructions on employing SHARP, including how to download and install the code, how to build the drivers for a test case, how to perform a calculation and how to visualize the results. Since SHARP has some specific library and environment dependencies, it is highly recommended that the user read this manual prior to installing SHARP. Verification tests cases are included to check proper installation of each module. It is suggested that the new user should first follow the step-by-step instructions provided for a test problem in this manual to understand the basic procedure of using SHARP before using SHARP for his/her own analysis. Both reference output and scripts are provided along with the test cases in order to verify correct installation and execution of the SHARP package. At the end of this manual, detailed instructions are provided on how to create a new test case so that user can perform novel multi-physics calculations with SHARP. Frequently asked questions are listed at the end of this manual to help the user to troubleshoot issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Testbed of Parallel Kernels for Computer Science Research

For several decades, computer scientists have sought guidance on how to evolve architectures, languages, and programming models for optimal performance, efficiency, and productivity. Unfortunately, this guidance is most often taken from the existing software/hardware ecosystem. Architects attempt to provide micro-architectural solutions to improve performance on fixed binaries. Researchers tweak compilers to improve code generation for existing architectures and implementations, and they may invent new programming models for fixed processor and memory architectures and computational algorithms. In today's rapidly evolving world of on-chip parallelism, these isolated and iterative improvements to performance may miss superior solutions in the same way gradient descent optimization techniques may get stuck in local minima. In an initial study, we have developed an alternate approach that, rather than starting with an existing hardware/software solution laced with hidden assumptions, defines the computational problems of interest and invites architects, researchers and programmers to implement novel hardware/ software co-designed solutions. Our work builds on the previous ideas of computational dwarfs, motifs, and parallel patterns by selecting a representative set of essential problems for which we provide: An algorithmic description; scalable problem definition; illustrative reference implementations; verification schemes. For simplicity, we focus initially on the computational problems of interest to the scientific computing community but proclaim the methodology (and perhaps a subset of the problems) as applicable to other communities. We intend to broaden the coverage of this problem space through stronger community involvement. Previous work has established a broad categorization of numerical methods of interest to the scientific computing, in the spirit of the NAS Benchmarks, which pioneered the basic idea of a 'pencil and paper benchmark' in the 1990s. The initial result of the more modern study was the seven dwarfs, which was subsequently extended to 13 motifs. These motifs have already been useful in defining classes of applications for architecture-software studies. However, these broad-brush problem statements often miss the nuance seen in individual kernels. For example, the computational requirements of particle methods vary greatly between the naive (but more accurate) direct calculations and the particle-mesh and particle-tree codes. Thus we commenced our study with an enumeration of problems, but then proceeded by providing not only reference implementations for each problem, but more importantly a mathematical definition that allows one to escape iterative approaches to software/hardware optimization. To ensure long term value, we have augmented each of our reference implementations with both a scalable problem generator and a verification scheme. In a paper we have prepared that documents our efforts, we describe in detail this process of problem definition, scalable input creation, verification, and implementation of reference codes for the scientific computing domain. Table 1 enumerates and describes the level of support we've developed for each kernel. We group these important kernels using the Berkeley dwarfs/motifs taxonomy using a red box in the appropriate column. As kernels become progressively complex, they build upon other, simpler computational methods. We note this dependency via orange boxes. After enumeration of the important numerical problems, we created a domain-appropriate high-level definition of each problem. To ensure future endeavors are not tainted by existing implementations, we specified the problem definition to be independent of both computer architecture and existing programming languages, models, and data types. Then, to provide context as to how such kernels productively map to existing architectures, languages and programming models, we produced reference implementations for most of the kernel (see table). These sample codes should be viewed as 'hints,' designed to show how other designers have mapped a problem's operands and operators to existing hardware and software. Since we wanted such implementations to be illustrative, we tried to ensure they were the most straightforward implementation in the easiest to understand languages using familiar architectures. To that end, most of the linear algebra-oriented computations are written in MATLAB using array indexing to process matrices, rather than one-line library calls to compute the same kernel. This ensures that the kernel's computation is explicit and readable in the implementation and not hidden behind a library. For other problems, such as the Barnes-Hut n-Body solver, the implementations were written in pure C, without any supporting library computations. Along this line, we have also created a scalable problem generator to accompany each computation.

97 MATHEMATICS AND COMPUTING↗

A verification and validation effort for high explosives at Los Alamos National Lab (u)

We have started a project to verify and validate ASC codes used to simulate detonation waves in high explosives. Since there are no non-trivial analytic solutions, we are going to compare simulated results with experimental data that cover a wide range of explosive phenomena. The intent is to compare both different codes and different high explosives (HE) models. The first step is to test the products equation of state used for the HE models, For this purpose, the cylinder test, flyer plate and plate-push experiments are being used. These experiments sample different regimes in thermodynamic phase space: the CJ isentrope for the cylinder tests, the isentrope behind an overdriven detonation wave for the flyer plate experiment, and expansion following a reflected CJ detonation for the plate-push experiment, which is sensitive to the Gruneisen coefficient. The results of our findings for PBX 9501 are presented here.

36 MATERIALS SCIENCE↗

SU-D-213-05: Design, Evaluation and First Applications of a Off-Site State-Of-The-Art 3D Dosimetry System

Purpose: To design, construct and commission a prototype in-house three dimensional (3D) dose verification system for stereotatic body radiotherapy (SBRT) verification at an off-site partner institution. To investigate the potential of this system to achieve sufficient performance (1mm resolution, 3% noise, within 3% of true dose reading) for SBRT verification. Methods: The system was designed utilizing a parallel ray geometry instigated by precision telecentric lenses and an LED 630nm light source. Using a radiochromic dosimeter, a 3D dosimetric comparison with our gold-standard system and treatment planning software (Eclipse) was done for a four-field box treatment, under gamma passing criteria of 3%/3mm/10% dose threshold. Post off-site installation, deviations in the system’s dose readout performance was assessed by rescanning the four-field box irradiated dosimeter and using line-profiles to compare on-site and off-site mean and noise levels in four distinct dose regions. As a final step, an end-to-end test of the system was completed at the off-site location, including CT-simulation, irradiation of the dosimeter and a 3D dosimetric comparison of the planned (Pinnacle{sup 3}) to delivered dose for a spinal SBRT treatment(12 Gy per fraction). Results: The noise level in the high and medium dose regions of the four field box treatment was relatively 5% pre and post installation. This reflects the reduction in positional uncertainty through the new design. This At 1mm dose voxels, the gamma pass rates(3%,3mm) for our in-house gold standard system and the off-site system were comparable at 95.8% and 93.2% respectively. Conclusion: This work will describe the end-to-end process and results of designing, installing, and commissioning a state-of-the-art 3D dosimetry system created for verification of advanced radiation treatments including spinal radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-C-BRD-04: Comparison of Shallow Fluence to Deep Point Dose Measurements for Spine VMAT SBRT Patient-Specific QA

Purpose: To investigate the sensitivity of traditional gamma-index-based fluence measurements for patient-specific measurements in VMAT delivered spine SBRT. Methods: The ten most recent cases for spine SBRT were selected. All cases were planned with Eclipse RapidArc for a TrueBeam STx. The delivery was verified using a point dose measurement with a Pinpoint 3D micro-ion chamber in a Standard Imaging Stereotactic Dose Verification Phantom. Two points were selected for each case, one within the target in a low dose-gradient region and one in the spinal cord. Measurements were localized using on-board CBCT. Cumulative and separate arc measurements were acquired with the ArcCheck and assessed using the SNC patient software with a 3%/3mm and 2%/2mm gamma analysis with global normalization and a 10% dose threshold. Correlations between data were determined using the Pearson Product-Moment Correlation. Results: For our cohort of patients, the measured doses were higher than calculated ranging from 2.2%–9.7% for the target and 1.0%–8.2% for the spinal cord. There was strong correlation between 3%/3mm and 2%/2mm passing rates (r=0.91). Moderate correlation was found between target and cord dose with a weak fit (r=0.67, R-Square=0.45). The cumulative ArcCheck measurements showed poor correlation with the measured point doses for both the target and cord (r=0.20, r=0.35). If the arcs are assessed separately with an acceptance criteria applied to the minimum passing rate between all arcs, a moderate negative correlation was found for the target and cord (r=−0.48, r= −0.71). The case with the highest dose difference (9.7%) received a passing rate of 97.2% for the cumulative arcs and 87.8% for the minimum with separate arcs. Conclusion: Our data suggest that traditional passing criteria using ArcCheck with cumulative measurements do not correlate well with dose errors. Separate arc analysis shows better correlation but may still miss large dose errors. Point dose verifications are recommended.

60 APPLIED LIFE SCIENCES↗

MOOSE-based Tritium Migration Analysis Program, Version 8 (TMAP8) for advanced open-source tritium transport and fuel cycle modeling

Tritium management is critical for the safety, sustainability, and economics of fusion energy systems, and advanced and reliable modeling tools help accelerate the development of tritium technologies. This paper presents the Tritium Migration Analysis Program, Version 8 (TMAP8), an open-source, MOOSE-based application developed to provide state-of-the-art tritium transport and fuel cycle modeling capabilities. TMAP8 aims to expand the capabilities of previous versions (i.e., TMAP4 and TMAP7) by leveraging modern computational techniques, ensuring high software quality assurance standards (key to building trust), and enabling multispecies, multiscale, and multiphysics simulations for integrated tritium transport modeling in complex geometries. This paper outlines TMAP8’s scope and rigorous development practices, emphasizing its transparency, accessibility, modularity, and reliability. We present the current suite of verification and validation cases based on those from TMAP4, demonstrating TMAP8’s accuracy and reliability against analytical solutions and experimental data. Additionally, the paper showcases TMAP8’s integrated fuel cycle modeling capabilities, highlighting its applicability at various scales and levels. The TMAP8 code and documentation are openly available, promoting collaborative development and widespread adoption within the fusion community. Future work will soon expand TMAP8’s verification and validation suite to include those from TMAP7 and other recent experimental studies for validation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Continued Verification of MOOSE Structural Mechanics Tools for Modeling Core Bowing Phenomena in Fast Reactors

Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program, an integrated multiphysics approach is being developed to model the core bowing phenomena important to liquid metal-cooled fast reactors. Core bowing is an important passive safety mechanism whereby increased power (which leads to temperature and flux gradients) influences the core to bow into less reactive configurations when the restraint system is properly designed. The phenomenon includes a complex interplay of radiation transport, duct temperature calculations involving fluid flow and heat transfer, and thermo-mechanical responses to the induced temperature and flux gradients. Structural material properties are also important to determining inelastic response to longer term flux gradients which cause irradiation creep and swelling. While core bowing provides a strong negative reactivity feedback when the restraint system is designed properly, it also results in additional forces between assemblies which increase the loads required to extricate them during refueling or control rod movement. Therefore, the restraint system must be designed with these tradeoffs in mind. The first stage of the work, which commenced in FY21 and continues through FY22, assesses thermo-mechanical modeling tools for producing core bowing predictions consistent with conventional tools. The Multiphysics Object Oriented Simulation Environment (MOOSE) Tensor Mechanics and Contact Modules are employed. This status report describes work on additional thermo-mechanical benchmark verification problems with increased complexity from the examples demonstrated in FY21. Several benchmark verification examples were selected from the IAEA verification and validation report. These examples involve clusters of ducts representative of a sector of a hexagonal reactor core which bow into each other and cause contact and load pad elevations, as well as single ducts subjected to irradiation fields undergoing swelling and subsequent bowing. The MOOSE-based results were compared to both IAEA benchmark participants’ results, analytic equations as available, and NUBOW-3D, a beam model code developed by Argonne National Laboratory. In every case, the MOOSE results agreed with other simulations results, providing additional verification basis of the tools for this particular physics application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-F-T-399: Migration of Treatment Planning Systems Without Beam Data Measurement

Purpose: Data acquisition for commissioning is steered by Treatment Planning System (TPS) requirements which can be cumbersome and time consuming involving significant clinic downtime. The purpose of this abstract is to answer if we could circumvent this by extracting data from existing TPS and speed up the process. Methods: Commissioning beam data was obtained from a clinically commissioned TPS (Pinnacle™) using Matlab™ generated Pinnacle™ executable scripts to commission a secondary 3D dose verification TPS (Eclipse™). Profiles and output factors for commissioning as required by Eclipse™ were computed on a 50 cm{sup 3} water phantom at a dose grid resolution of 2mm3. Verification doses were computed and compared to clinical TPS dose profiles as per TG-106 guidelines. Standard patient plans from Pinnacle™ including IMRT and VMAT plans were re-computed keeping the same monitor units (in order to perform true comparison) using Eclipse™. Computed dose was exported back to Pinnacle for comparison to original plans. This methodology enables us to alleviate all ambiguities that arise in such studies. Results: Profile analysis using in-house software for 6x, showed that for all field sizes including small MLC generated fields, 100% of infield and penumbra data points of Eclipse™ match Pinnacle™ generated and measured profiles with 2%/2 mm gamma criteria. Excellent agreement was observed in the penumbra regions, with all data points passing DTA criteria for complex C-shaped and S-shaped profiles. Patient plan dose volume histograms (DVHs) and isodose lines agreed well to within a 1.5% for target coverage. Conclusion: Secondary 3D dose checking is of utmost importance with advanced techniques such as IMRT and VMAT. Migration of TPS is possible without compromising accuracy or enduring the cumbersome measurement of commissioning data. Economizing time for commissioning such a verification system or for migration of TPS can add great QA value and minimize downtime.

60 APPLIED LIFE SCIENCES↗