Search NASA⌕ Search

SEARCH · Search NASA

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Growing Cobalt Silicide Columns In Silicon

Codeposition by molecular-beam epitaxy yields variety of structures. Proposed fabrication process produces three-dimensional nanometer-sized structures on silicon wafers. Enables control of dimensions of metal and semiconductor epitaxial layers in three dimensions instead of usual single dimension (perpendicular to the plane of the substrate). Process used to make arrays of highly efficient infrared sensors, high-speed transistors, and quantum wires. For fabrication of electronic devices, both shapes and locations of columns controlled. One possible technique for doing this electron-beam lithography, see "Making Submicron CoSi2 Structures on Silicon Substrates" (NPO-17736).

Fathauer, Obert W.↗

Mechanical end joint system for connecting structural column elements

A mechanical end joint system is presented that eliminates the possibility of free movements between the joint halves during loading or vibration. Both node joint body (NJB) and column end joint body (CEJB) have cylindrical engaging ends. Each of these ends has an integral semicircular tongue and groove. The two joint halves are engaged transversely - the tongue of the NJB mating with the groove of the CEJB and vice versa. The joint system employs a spring loaded internal latch mechanism housed in the CEJB. During mating, this mechanism is pushed away from the NJB and enters the NJB when mating is completed. In order to lock the joint and add a preload across the tongue and groove faces, an operating ring collar is rotated through 45 deg causing an internal mechanism to compress a Belleville washer preload mechanism. This causes an equal and opposite force to be exerted on the latch bolt and the latch plunger. This force presses the two joint halves tightly together. In order to prevent inadvertent disassembly, a secondary lock is also engaged when the joint is closed. Plungers are carried in the operating ring collar. When the joint is closed, the plungers fall into tracks on the CEJB, which allows the joint to be opened only when the operating ring collar and plungers are pushed directly away from the joining end. One application of this invention is the rapid assembly and disassembly of diverse skeletal framework structures which is extremely important in many projects involving the exploration of space.

Bush, Harold G.↗

AVIRIS Spectrometer Maps Total Water Vapor Column

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) processes maps of vertical-column abundances of water vapor in atmosphere with good precision and spatial resolution. Maps provide information for meteorology, climatology, and agriculture.

Conel, James E.↗

Cryogenic focussing, ohmically heated on-column trap

A procedure is described for depositing a conductive layer of gold on the exterior of a fused-silica capillary used in gas chromatography. By subjecting a section of the column near the inlet to a thermal cycle of cryogenic cooling and ohmic heating, volatile samples are concentrated and subsequently injected. The performance of this trap as a chromatographic injector is demonstrated. Several additional applications are suggested and the unique properties of this device are discussed.

Springston, Stephen R.↗

Trends in column ozone based on TOMS data - Dependence on month, latitude, and longitude

On the basis of the TOMS satellite column ozone data in latitudes 70 deg S-70 deg N from November 1978 to May 1990, a statistical model is used to estimate the trends in ozone as a function of latitude, longitude, and month. The trends in the TOMS ozone data are highly seasonal and dependent on location. Near the equator, the estimated monthly trends are not significantly different from zero. For high latitudes, most of the estimated monthly trends are negative. In January, February, and March, there are some positive trend estimates in the western hemisphere around latitude 60 deg N. The most negative trends for these three months also appear in the high latitudes of the northern hemisphere. Starting in June, more negative trends appear in the latitudes 50 deg S-70 deg S than the trends in the rest of the world considered. A large depletion develops during the spring time (September to November) in the southern high-latitude region, and the area of peak ozone decline is moving eastward during the period. The largest negative trends (about -29 percent per decade) for the area considered in this study appear in October around the latitude 70 deg S and longitudes 20 deg W-100 deg W region. For the northern hemisphere, the year-round trend estimates for latitudes 30 deg N-70 deg N range from -0.96 percent to -7.43 percent per decade. In the latitudes 30 deg N-50 deg N, the winter trend estimates are more negative than those for the summer and the fall. However, this pattern did not hold for latitudes 50 deg N-70 deg N.

Niu, Xufeng↗

Kelvin waves in total column ozone

Tropical Kelvin waves have been observed previously in ozone mixing ratio data from the SBUV (Solar Backscatter Ultraviolet) and LIMS (Limb Infrared Monitor of the Stratosphere) instruments on board the Nimbus-7 satellite. Kelvin wave features in total column ozone, using version 6 data from the Total Ozone Mapping Spectrometer (TOMS) instrument (also on board Nimbus-7) are investigated. Results show eastward-propagating zonal waves 1-2 with periods approximately 5-15 days, amplitudes approximately 3-5 DU, and latitudinal symmetry typical of Kelvin waves. A simplified model calculation suggests that the primary source for the perturbations is slow Kelvin waves in the lower-to-middle stratosphere. Maximum Kelvin wave signatures occur in conjunction with westward lower-to-middle stratospheric equatorial zonal winds (a quasi-biennial oscillation (QBO) wind modulation effect).

Ziemke, J. R.↗

Flow-influenced stabilization of liquid columns in a dynamic plateau chamber

An apparatus designed to imbed a liquid column or bridge in an axial flow is described. The bridge liquid is density matched to the water in the external flow to simulate low gravity (about 0.001 earth G). The influence of flow on shape is the focus. Results show that flow modifies static shapes in a way that can be accounted for by static theory even for moderate deviations from cylindrical shape, at least for low flow rates.

Lowry, B. J.↗

Shortwave cloud-radiative forcing at the top of the atmosphere at the surface and of the atmospheric column as determined from ISCCP C1 data

The paper employs the C1 data of the International Satellite Cloud Climatology Project, along with the Satellite Algorithm for Shortwave Radiation Budget, to estimate the shortwave cloud effects in terms of the cloud-radiative forcing at the top of the atmosphere (TOA) and at the surface, and that of the atmospheric column on a global scale for the July months of 1983-1985. The cloud forcing for July 1985 is underestimated, by about 8/sq Wm, compared with that obtained from the Earth Radiation Budget Experiment. The cloud forcing at the surface is almost identical to that at the TOA, indicating that the effect of clouds on the shortwave energy budget of the surface-atmosphere system is such that most of the cooling is at the surface.

Laszlo, Istvan↗

Nonlinear response of graphite-epoxy wide columns subject to eccentric load

It is shown that including the effects of bend-twist coupling and material nonlinearity on the large displacement flexural response of graphite-epoxy wide columns is necessary to adequately model their response. Results from static tests on 0(30)T and (30/0/-30 sub 5)s laminated specimens under eccentric axial compression are compared to a nonlinear analysis. The analysis is based on a Kantrovich expansion of the displacements in the width coordinate and a finite element representation in the axial coordinate. An incremental, updated Lagrangian formulation and element corotational coordinates are employed. Nonlinear elastic material behavior was measured in a separate set of material characterization tests, and these data are used to compute tangent stillnesses in the updated configuration.

Griffin, O. H., Jr.↗

A technique for deriving column-integrated water content using VAS split-window data

An algorithm is examined that uses VISSR Atmospheric Sounder (VAS) 11- and 12-micron (split-window) data to derive column-integrated water content (IWC) at mesoscale resolution. The algorithm is physically based and derives its first-guess information from radiosonde data. The procedure is applied first to a test case data set and then to the 19 June 1986 study day from the Cooperative Huntsville Meteorological Experiment (COHMEX). Ground truth data for verifying results from the technique include IWC from National Weather Service and COHMEX radiosondes, the Multispectral Atmospheric Mapping Sensor (MAMS), and a special set of VAS soundings (12 channel) using an independent retrieval method. Results from the test case show reasonable accuracy with the rms errors as low as +/- 3.8 mm. On the 19 June case study day IWC analyses depict reasonable gradients and exhibit good spatial and temporal continuity. Furthermore, they provide insight into preferred regions for cumulus cloud and thunderstorm formation. On the average, a mean absolute retrieval error of 2.4 mm (an 8.1 percent error) and a rms error of +/- 2.9 mm are obtained on the case study day. These results compare favorably with those from existing VAS IWC techniques. Overall, the findings indicate that the technique has excellent potential to depict mesoscale moisture variations.

Guillory, Anthony R.↗

CS band intensity and column densities and production rates of 15 comets

An accurate fluorescence efficiency of the CS(0,0) band and the lifetime of CS have been calculated at 1 AU heliocentric distance. Model-independent CS column densities and production rates are determined from derived fluorescent emission rates (g-factors) and lifetimes for 15 comets: Austin (1982g), Borrelly (1980i), Bradfield (1979X), Crommelin (1983n), Encke (1980), Encke (1984), Giacobini-Zinner (1984e), Halley (1982i), IRAS-Araki-Alcock (1983d), Meier (1980q), Panther (1980u), Stephan-Oterma (1980g), Tuttle (1980h), West (1975n), and Wilson (1986l).

Sanzovo, G. C.↗

Tests on duralumin columns for aircraft construction

The following paper is based on the results of tests, upon duralumin columns, contained in two theses presented to the Department of Civil and Sanitary Engineering of the Massachusetts Institute of Technology.

Lee, John G↗

Curves showing column strength of steel and duralumin tubing

Given here are a set of column strength curves that are intended to simplify the method of determining the size of struts in an airplane structure when the load in the member is known. The curves will also simplify the checking of the strength of a strut if the size and length are known. With these curves, no computations are necessary, as in the case of the old-fashioned method of strut design. The process is so simple that draftsmen or others who are not entirely familiar with mechanics can check the strength of a strut without much danger of error.

Ross, Orrin E↗

The compressive strength of duralumin columns of equal angle section

This report presents a chart giving the compressive strength of duralumin columns of equal angle section. The data used in the construction of the chart were obtained from various published sources and were correlated with theory in the range where secondary failure occurred. Appendices are included giving excerpts from Army and Navy specifications for duralumin and approximate formulas for the properties of the equal angle section.

Lundquist, Eugene E↗

The Influence of the Form of a Wooden Beam on Its Stiffness and Strength III : Stresses in Wood Members Subjected to Combined Column and Beam Action

The general purpose in this study was to determine the stresses in a wooden member subjected to combined beam and column action. What may be considered the specific purpose, as it relates more directly to the problem of design, was to determine the particular stress that obtains at maximum load which, for combined loading, does not occur simultaneously with maximum stress.

Newlin, J A↗

Kelvin waves in total column ozone

Tropical Kelvin waves have been observed previously in ozone mixing ratio data from the SBUV (Solar Backscatter Ultraviolet) and LIMS (Limb Infrared Monitor of the Stratosphere) instruments on board the Nimbus-7 satellite. The present study investigates Kelvin wave features in total column ozone, using version 6 data from the Total Ozone Mapping Spectrometer (TOMS) instrument (also on Nimbus-7). Results show eastward-propagating zonal waves 1-2 with periods approx. 5-15 days, amplitudes approx. 3-5 Dobson Units (1-2% of the time mean), and latitudinal symmetry typical of Kelvin waves. The analyses and a linear model in this study suggest that the primary source of the perturbations is slow Kelvin waves in the lower-to-middle stratosphere. Maximum Kelvin wave signatures occur in conjunction with westward lower-to-middle stratospheric equatorial zonal winds (a quasi-biennial oscillation (QBO) wind modulation effect). The significance of these results is that the TOMS data are shown to be useful for investigations with global coverage of a major component of tropical stratospheric dynamics, Kelvin waves. The TOMS data set with its excellent coverage and high quality should be useful in validating model studies in the relatively data sparse and dynamically difficult tropical region.

Ziemke, J. R.↗

ASCA observations of the warm absorber in MCG-6-30-15: The discovery of a change in column density

We report the first X-ray observations of the Seyfert 1 galaxy MCG-6-30-15 obtained at medium spectral resolution. The partially-ionized, 'warm' absorber is resolved and shown to be due to O VII and O VIII. The main absorption edge agrees with that of O VII at the redshift of the galaxy to within 1%. The column density of the absorbing material is greater by a factor of 2 in the first of our two obsevations, which were 3 weeks apart, while the mean flux is slightly lower and the ionization parameter slightly higher. We also discuss the flourescent iron emssion line seen in the source, which is at 6.40 keV. The line is significantly broadened, with a Full Width at Half Maximum (FWHM) of about 0.4 keV.

Fabian, Andrew C.↗