Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

30 Gy or 34 Gy? Comparing 2 Single-Fraction SBRT Dose Schedules for Stage I Medically Inoperable Non-Small Cell Lung Cancer

Purpose: To review outcomes of 2 single-fraction lung stereotactic body radiation therapy (SBRT) schedules used for medically inoperable early stage lung cancer. Methods and Materials: Patients in our institution have been treated on and off protocols using single-fraction SBRT (30 Gy and 34 Gy, respectively). All patients had node-negative lung cancer measuring ≤5 cm and lying ≥2 cm beyond the trachea-bronchial tree and were treated on a Novalis/BrainLAB system with the ExactTrac positioning system for daily image guidance. Results: For the interval from 2009 to 2012, 80 patients with 82 lesions were treated with single-fraction lung SBRT. Fifty-five patients (69%) and 25 patients (31%) received 30 Gy and 34 Gy, respectively. In a comparison of 30 Gy and 34 Gy cohorts, patient and tumor characteristics were balanced and median follow-up in months was 18.7 and 17.8, respectively. The average heterogeneity-corrected mean doses to the target were 33.75 Gy and 37.94 Gy for the 30-Gy and 34-Gy prescriptions, respectively. Comparing 30-Gy and 34-Gy cohorts, 92.7% and 84.0% of patients, respectively, experienced no toxicity (P was not significant), and had neither grade 3 nor higher toxicities. For the 30-Gy and 34-Gy patients, rates of 1-year local failure, overall survival, and lung cancer-specific mortality were 2.0% versus 13.8%, 75.0% versus 64.0%, and 2. 1% versus 16.0%, respectively (P values for differences were not significant). Conclusions: This is the largest single-fraction lung SBRT series yet reported. and it confirms the safety, efficacy, and minimal toxicity of this schedule for inoperable early stage lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Voice Quality After Treatment of Early Vocal Cord Cancer: A Randomized Trial Comparing Laser Surgery With Radiation Therapy

Objective: Early laryngeal cancer is usually treated with either transoral laser surgery or radiation therapy. The quality of voice achieved with these treatments has not been compared in a randomized trial. Methods and Materials: Male patients with carcinoma limited to 1 mobile vocal cord (T1aN0M0) were randomly assigned to receive either laser surgery (n=32) or external beam radiation therapy (n=28). Surgery consisted of tumor excision with a CO{sub 2} laser with the patient under general anaesthesia. External beam radiation therapy to the larynx was delivered to a cumulative dose of 66 Gy in 2-Gy daily fractions over 6.5 weeks. Voice quality was assessed at baseline and 6 and 24 months after treatment. The main outcome measures were expert-rated voice quality on a grade, roughness, breathiness, asthenia, and strain (GRBAS) scale, videolaryngostroboscopic findings, and the patients' self-rated voice quality and its impact on activities of daily living. Results: Overall voice quality between the groups was rated similar, but voice was more breathy and the glottal gap was wider in patients treated with laser surgery than in those who received radiation therapy. Patients treated with radiation therapy reported less hoarseness-related inconvenience in daily living 2 years after treatment. Three patients in each group had local cancer recurrence within 2 years from randomization. Conclusions: Radiation therapy may be the treatment of choice for patients whose requirements for voice quality are demanding. Overall voice quality was similar in both treatment groups, however, indicating a need for careful consideration of patient-related factors in the choice of a treatment option.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Decade of Comparative Dose Planning Studies for Early-Stage Hodgkin Lymphoma: What Can We Learn?

During the past 4 decades, the treatment of Hodgkin lymphoma has changed dramatically, and combined modality treatment is now considered the standard of care for patients with early-stage disease. However, the risk of late effects has led to concerns regarding the use of radiation therapy, especially in young patients with a long life expectancy. In this study, we review the current evidence for modern radiation therapy planning and delivery techniques in the treatment of early-stage Hodgkin lymphoma with a focus on a reduced delivered dose, a reduced irradiated volume, and a more conformal dose distribution. Although studies are difficult to compare because of differences in field technique, prescribed dose, target volumes, patient population, and reported dosimetric and plan evaluation parameters, modern radiation therapy significantly reduces exposure to normal tissues and thereby the estimated risk of late effects. However, there is no such thing as a single best modern delivery technique when multiple organs at risk are considered simultaneously because of the heterogeneity in patient anatomy and disease location, and the choice of radiation therapy technique should be made individually for each patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparative Study of the Hypoxia PET Tracers [{sup 18}F]HX4, [{sup 18}F]FAZA, and [{sup 18}F]FMISO in a Preclinical Tumor Model

Purpose: Several individual clinical and preclinical studies have shown the possibility of evaluating tumor hypoxia by using noninvasive positron emission tomography (PET). The current study compared 3 hypoxia PET tracers frequently used in the clinic, [{sup 18}F]FMISO, [{sup 18}F]FAZA, and [{sup 18}F]HX4, in a preclinical tumor model. Tracer uptake was evaluated for the optimal time point for imaging, tumor-to-blood ratios (TBR), spatial reproducibility, and sensitivity to oxygen modification. Methods and Materials: PET/computed tomography (CT) images of rhabdomyosarcoma R1-bearing WAG/Rij rats were acquired at multiple time points post injection (p.i.) with one of the hypoxia tracers. TBR values were calculated, and reproducibility was investigated by voxel-to-voxel analysis, represented as correlation coefficients (R) or Dice similarity coefficient of the high-uptake volume. Tumor oxygen modifications were induced by exposure to either carbogen/nicotinamide treatment or 7% oxygen breathing. Results: TBR was stabilized and maximal at 2 hours p.i. for [{sup 18}F]FAZA (4.0 ± 0.5) and at 3 hours p.i. for [{sup 18}F]HX4 (7.2 ± 0.7), whereas [{sup 18}F]FMISO showed a constant increasing TBR (9.0 ± 0.8 at 6 hours p.i.). High spatial reproducibility was observed by voxel-to-voxel comparisons and Dice similarity coefficient calculations on the 30% highest uptake volume for both [{sup 18}F]FMISO (R = 0.86; Dice coefficient = 0.76) and [{sup 18}F]HX4 (R = 0.76; Dice coefficient = 0.70), whereas [{sup 18}F]FAZA was less reproducible (R = 0.52; Dice coefficient = 0.49). Modifying the hypoxic fraction resulted in enhanced mean standardized uptake values for both [{sup 18}F]HX4 and [{sup 18}F]FAZA upon 7% oxygen breathing. Only [{sup 18}F]FMISO uptake was found to be reversible upon exposure to nicotinamide and carbogen. Conclusions: This study indicates that each tracer has its own strengths and, depending on the question to be answered, a different tracer can be put forward.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic Resonance Imaging–Guided versus Surrogate-Based Motion Tracking in Liver Radiation Therapy: A Prospective Comparative Study

Purpose: This study applied automatic feature detection on cine–magnetic resonance imaging (MRI) liver images in order to provide a prospective comparison between MRI-guided and surrogate-based tracking methods for motion-compensated liver radiation therapy. Methods and Materials: In a population of 30 subjects (5 volunteers plus 25 patients), 2 oblique sagittal slices were acquired across the liver at high temporal resolution. An algorithm based on scale invariant feature transform (SIFT) was used to extract and track multiple features throughout the image sequence. The position of abdominal markers was also measured directly from the image series, and the internal motion of each feature was quantified through multiparametric analysis. Surrogate-based tumor tracking with a state-of-the-art external/internal correlation model was simulated. The geometrical tracking error was measured, and its correlation with external motion parameters was also investigated. Finally, the potential gain in tracking accuracy relying on MRI guidance was quantified as a function of the maximum allowed tracking error. Results: An average of 45 features was extracted for each subject across the whole liver. The multi-parametric motion analysis reported relevant inter- and intrasubject variability, highlighting the value of patient-specific and spatially-distributed measurements. Surrogate-based tracking errors (relative to the motion amplitude) were were in the range 7% to 23% (1.02-3.57mm) and were significantly influenced by external motion parameters. The gain of MRI guidance compared to surrogate-based motion tracking was larger than 30% in 50% of the subjects when considering a 1.5-mm tracking error tolerance. Conclusions: Automatic feature detection applied to cine-MRI allows detailed liver motion description to be obtained. Such information was used to quantify the performance of surrogate-based tracking methods and to provide a prospective comparison with respect to MRI-guided radiation therapy, which could support the definition of patient-specific optimal treatment strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Toxicity After Image-Guided Intensity Modulated Radiation Therapy Compared to 3D Conformal Radiation Therapy in Prostate Cancer Patients

Purpose: Image-guided intensity modulated radiation therapy (IG-IMRT) allows significant dose reductions to organs at risk in prostate cancer patients. However, clinical data identifying the benefits of IG-IMRT in daily practice are scarce. The purpose of this study was to compare dose distributions to organs at risk and acute gastrointestinal (GI) and genitourinary (GU) toxicity levels of patients treated to 78 Gy with either IG-IMRT or 3D-CRT. Methods and Materials: Patients treated with 3D-CRT (n=215) and IG-IMRT (n=260) receiving 78 Gy in 39 fractions within 2 randomized trials were selected. Dose surface histograms of anorectum, anal canal, and bladder were calculated. Identical toxicity questionnaires were distributed at baseline, prior to fraction 20 and 30 and at 90 days after treatment. Radiation Therapy Oncology Group (RTOG) grade ≥1, ≥2, and ≥3 endpoints were derived directly from questionnaires. Univariate and multivariate binary logistic regression analyses were applied. Results: The median volumes receiving 5 to 75 Gy were significantly lower (all P<.001) with IG-IMRT for anorectum, anal canal, and bladder. The mean dose to the anorectum was 34.4 Gy versus 47.3 Gy (P<.001), 23.6 Gy versus 44.6 Gy for the anal canal (P<.001), and 33.1 Gy versus 43.2 Gy for the bladder (P<.001). Significantly lower grade ≥2 toxicity was observed for proctitis, stool frequency ≥6/day, and urinary frequency ≥12/day. IG-IMRT resulted in significantly lower overall RTOG grade ≥2 GI toxicity (29% vs 49%, respectively, P=.002) and overall GU grade ≥2 toxicity (38% vs 48%, respectively, P=.009). Conclusions: A clinically meaningful reduction in dose to organs at risk and acute toxicity levels was observed in IG-IMRT patients, as a result of improved technique and tighter margins. Therefore reduced late toxicity levels can be expected as well; additional research is needed to quantify such reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Advantages of Midventilation Compared With Internal Target Volume for Radiation Therapy of Pancreatic Cancer

Purpose: The midventilation (midV) approach can be used to take respiratory-induced pancreatic tumor motion into account during radiation therapy. In this study, the dosimetric consequences for organs at risk and tumor coverage of using a midV approach compared with using an internal target volume (ITV) were investigated. Methods and Materials: For each of the 18 patients, 2 treatment plans (25 × 2.0 Gy) were created, 1 using an ITV and 1 using a midV approach. The midV dose distribution was blurred using the respiratory-induced motion from 4-dimensional computed tomography. The resulting planning target volume (PTV) coverage for this blurred dose distribution was analyzed; PTV coverage was required to be at least V{sub 95%} >98%. In addition, the change in PTV size and the changes in V{sub 10Gy}, V{sub 20Gy}, V{sub 30Gy}, V{sub 40Gy}, D{sub mean} and D{sub 2cc} for the stomach and for the duodenum were analyzed; differences were tested for significance using the Wilcoxon signed-rank test. Results: Using a midV approach resulted in sufficient target coverage. A highly significant PTV size reduction of 13.9% (P<.001) was observed. Also, all dose parameters for the stomach and duodenum, except the D{sub 2cc} of the duodenum, improved significantly (P≤.002). Conclusions: By using the midV approach to account for respiratory-induced tumor motion, a significant PTV reduction and significant dose reductions to the stomach and to the duodenum can be achieved when irradiating pancreatic tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase 3 Multi-Center, Prospective, Randomized Trial Comparing Single-Dose 24 Gy Radiation Therapy to a 3-Fraction SBRT Regimen in the Treatment of Oligometastatic Cancer

This prospective phase 3 randomized trial was designed to test whether ultra high single-dose radiation therapy (24 Gy SDRT) improves local control of oligometastatic lesions compared to a standard hypofractionated stereotactic body radiation therapy regimen (3 × 9 Gy SBRT). The secondary endpoint was to assess the associated toxicity and the impact of ablation on clinical patterns of metastatic progression.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Moderately Hypofractionated Once-Daily Compared With Twice-Daily Thoracic Radiation Therapy Concurrently With Etoposide and Cisplatin in Limited-Stage Small Cell Lung Cancer: A Multicenter, Phase II, Randomized Trial

Chemotherapy and concurrent thoracic radiation therapy (CCTRT) followed by prophylactic cranial irradiation (PCI) is the standard of care for limited-stage small cell lung cancer (LS-SCLC). We aimed to compare the efficacy and toxicity of moderately hypofractionated once-daily CCTRT with that of a standard twice-daily regimen.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Particle simulation of Coulomb collisions: Comparing the methods of Takizuka and Abe and Nanbu

The interactions of charged particles in a plasma are governed by long-range Coulomb collision. We compare two widely used Monte Carlo models for Coulomb collisions. One was developed by Takizuka and Abe in 1977, the other was developed by Nanbu in 1997. We perform deterministic and statistical error analysis with respect to particle number and time step. The two models produce similar stochastic errors, but Nanbu's model gives smaller time step errors. Error comparisons between these two methods are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Feasibility Study on the Identification of Postlumpectomy Seromas by a Radiation Therapist Compared with That by Radiation Oncologists in Radiation Therapy Planning for Early Stage Breast Cancer

Computed tomography (CT) simulation is currently used to identify the tumour bed in patients with early stage breast cancer requiring whole-breast and boost radiation therapy. Postlumpectomy breast seromas as visible on CT data have been identified as a proxy for the tumour bed. This study aims to quantify the incidence of postsurgical tumour bed seromas identified at CT simulation and report how well a radiation therapist (RT) is able to identify these seromas compared with those contoured by radiation oncologists (ROs).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative determination of the {alpha}/{beta} phase fraction in {alpha}+{beta}-titanium alloys using X-ray diffraction and electron microscopy

A comparison is made between the measured {alpha}/{beta} phase fractions in Ti-6246 using X-ray diffraction (XRD) and electron microscopy. Image analysis of SEM and TEM images was compared to the phase fraction estimate obtained using electron backscattered diffraction, lab and high-energy synchrotron XRD. There was a good agreement between the electron microscopic and diffraction techniques, provided that the microstructural parameters of grain size and texture are estimated correctly when using quantitative Rietveld refinement.

36 MATERIALS SCIENCE↗

Comparative dielectric studies of nanostructured BaTiO{sub 3}, CaCu{sub 3}Ti{sub 4}O{sub 12} and 0.5BaTiO{sub 3}⋅ 0.5CaCu{sub 3}Ti{sub 4}O{sub 12} nano-composites synthesized by modified sol–gel and solid state methods

BaTiO{sub 3} (BTO), CaCu{sub 3}Ti{sub 4}O{sub 12} (CCTO) and 0.5BaTiO{sub 3}·0.5CaCu{sub 3}Ti{sub 4}O{sub 12} (BTO–CCTO), as a new nano-composite ceramic, were successfully designed and fabricated by a semi-wet gel route and a modified solid state method. The dielectric properties of the BTO–CCTO ceramic were compared to those of the BTO and CCTO ceramics at lower sintering temperatures and durations. The X-ray diffraction analysis revealed that the BTO and CCTO ceramics form a single crystalline phase and the average crystalline sizes calculated from X-ray diffraction data were in the range of 40–65 nm. The particle sizes of the BTO, CCTO, and BTO–CCTO ceramics obtained from transmission electron microscopy images were in the ranges of 40–65 nm, 80–110 nm, and 70–95 nm, respectively. The phase composition and microstructure were studied by X-ray diffraction and scanning electron microscopy. The energy dispersive X-ray results demonstrated the purity and stoichiometry of the BTO–CCTO nano-composite. The grain sizes of the BTO, CCTO and BTO–CCTO ceramics were found to be in the ranges of 500 nm–1 μm, 4–24 μm, and 250 nm–4 μm, respectively. The AC conductivity as a function of frequency confirmed the semiconducting nature of all of the ceramics and obeyed the Jonscher's power law. The impedance spectrum measurement result showed that the CCTO ceramic possessed an exceptional grain boundary resistance, which supports the internal barrier layer capacitance (IBLC) mechanism present in this ceramic and is responsible for the high ε{sub r} values. - Highlights: • Nanostructured BaTiO{sub 3}, CaCu{sub 3}Ti{sub 4}O{sub 12}, and 0.5BaTiO{sub 3}⋅ 0.5CaCu{sub 3}Ti{sub 4}O{sub 12} have been synthesized. • XRD and TEM analysis confirmed the formation of nanoparticles, 40–65 and 50–90 nm. • Impedance analysis shows high grain-boundary resistance present in CCTO ceramic. • AC conductivity as a function of frequency confirms the semiconducting nature.

36 MATERIALS SCIENCE↗

Segmentation and Comparative Modeling in an 8.6-Å Cryo-EM Map of the Singapore Grouper Iridovirus

SGIV, or Singapore grouper iridovirus, is a large double-stranded DNA virus, reaching a diameter of 220 nm and packaging a genome of 140 kb. We present a 3D cryoelectron microscopy (cryo-EM) icosahedral reconstruction of SGIV determined at 8.6-Å resolution. It reveals several layers including a T = 247 icosahedral outer coat, anchor proteins, a lipid bilayer, and the encapsidated DNA. A new segmentation tool, iSeg, was applied to extract these layers from the reconstructed map. The outer coat was further segmented into major and minor capsid proteins. None of the proteins extracted by segmentation have known atomic structures. Here, we generated models for the major coat protein using three comparative modeling tools, and evaluated each model using the cryo-EM map. Our analysis reveals a new architecture in the Iridoviridae family of viruses. It shares similarities with others in the same family, e.g., Chilo iridescent virus, but also shows new features of the major and minor capsid proteins.

59 BASIC BIOLOGICAL SCIENCES↗

Apples and oranges: don't compare levelized cost of renewables: Joskow

MIT Prof. Paul Joskow points out that the levelized metric is inappropriate for comparing intermittent generating technologies like wind and solar with dispatchable generating technologies like nuclear, gas combined cycle, and coal. The levelized comparison fails to take into account differences in the production profiles of intermittent and dispatchable generating technologies and the associated large variations in the market value of the electricity they supply. When the electricity is produced by an intermittent generating technology, the level of output and the value of the electricity at the times when the output is produced are key variables that should be taken into account.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparative assessment of municipal sewage sludge incineration, gasification and pyrolysis for a sustainable sludge-to-energy management in Greece

Highlights: • The high output of MSS highlights the need for alternative routes of valorization. • Evaluation of 3 sludge-to-energy valorisation methods through SWOT analysis. • Pyrolysis is an energy and material recovery process resulting to ‘zero waste’. • Identification of challenges and barriers for MSS pyrolysis in Greece was investigated. • Adopters of pyrolysis systems face the challenge of finding new product markets. - Abstract: For a sustainable municipal sewage sludge management, not only the available technology, but also other parameters, such as policy regulations and socio-economic issues should be taken in account. In this study, the current status of both European and Greek Legislation on waste management, with a special insight in municipal sewage sludge, is presented. A SWOT analysis was further developed for comparison of pyrolysis with incineration and gasification and results are presented. Pyrolysis seems to be the optimal thermochemical treatment option compared to incineration and gasification. Sewage sludge pyrolysis is favorable for energy savings, material recovery and high added materials production, providing a ‘zero waste’ solution. Finally, identification of challenges and barriers for sewage sludge pyrolysis deployment in Greece was investigated.

09 BIOMASS FUELS↗

Molecular Dynamics Simulation of Tri-n-Butyl-Phophate Liquid: A Force Field Comparative Study

Molecular dynamics (MD) simulations were conducted to compare the performance of four force fields in predicting thermophysical properties of tri-n-butyl-phosphate (TBP) in the liquid phase. The intramolecular force parameters used were from the Assisted Model Building with Energy Refinement (AMBER) force field model. The van der Waals parameters were based on either the AMBER or the Optimized Potential for Liquid Simulation (OPLS) force fields. The atomic partial charges were either assigned by performing quantum chemistry calculations or utilized previously published data, and were scaled to approximate the average experimental value of the electric dipole moment. Canonical ensemble computations based on the aforementioned parameters were performed near the atmospheric pressure and temperature to obtain the electric dipole moment, mass density, and self-diffusion coefficient. In addition, the microscopic structure of the liquid was characterized via pair correlation functions between selected atoms. It has been demonstrated that the electric dipole moment can be approximated within 1% of the average experimental value by virtue of scaled atomic partial charges. The liquid mass density can be predicted within 0.5-1% of its experimentally determined value when using the corresponding charge scaling. However, in all cases the predicted self- diffusion coefficient is significantly smaller than a commonly quoted experimental measurement; this result is qualified by the fact that the uncertainty of the experimental value was not available.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗