Search NASA⌕ Search

SEARCH · Search NASA

Results for “data taking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects such as coding an Arduino, building PVC piping, and 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into and out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled or pushed through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point. These times, as well as the temperatures, are the data necessary for the project and must be extremely accurate.

61 RADIATION PROTECTION AND DOSIMETRY↗

New methods for indexing multi-lattice diffraction data

A new indexing method is presented which is capable of indexing multiple crystal lattices from narrow wedges of data. The efficacy of this method is demonstrated with both semi-synthetic multi-lattice data and real multi-lattice data recorded from microcrystals of ∼1 µm in size. A new indexing method is presented which is capable of indexing multiple crystal lattices from narrow wedges of diffraction data. The method takes advantage of a simplification of Fourier transform-based methods that is applicable when the unit-cell dimensions are known a priori. The efficacy of this method is demonstrated with both semi-synthetic multi-lattice data and real multi-lattice data recorded from crystals of ∼1 µm in size, where it is shown that up to six lattices can be successfully indexed and subsequently integrated from a 1° wedge of data. Analysis is presented which shows that improvements in data-quality indicators can be obtained through accurate identification and rejection of overlapping reflections prior to scaling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Next Steps for Compressively Sensed Video in Transmission Electron Microscopy

Here, compressive sensing (CS) is a fast-emerging approach for improving data throughput by taking advantage of the inherent compressibility of real world data—the same kind of compressibility that allows millions of users to stream full-screen video without breaking the internet. Transmission electron microscope (TEM) users regularly collect multi-GB data sets and then use aggressive data reduction strategies to draw out the tiny residual of Shannon entropy that answers the question they wanted to ask. Much of the raw-byte-count information in an acquisition is random, redundant, or irrelevant, yet its collection still represents substantial cost in terms of instrumentation bandwidth and sample damage.

47 OTHER INSTRUMENTATION↗

Improved determination of the astrophysical S(0) factor of the {sup 15}N(p,{alpha}){sup 12}C reaction

We present new improved R matrix fits of direct data and indirect Trojan Horse data for the {sup 15}N(p,{alpha}){sup 12}C reaction and provide a more accurate recommended value of S(0)=73.0{+-}5.0 MeV b from direct Redder data [A. Redder et al., Z. Phys. A 305, 325 (1982)] and S(0)=70.0{+-}13.5 MeV b from the Trojan Horse data [M. La Cognata et al., Phys. Rev. C 76, 065804 (2007)]. We also analyze a recent fit by Barker [F. C. Barker, Phys. Rev. C 78, 044611 (2008)] and demonstrate that when all the uncertainties are taken into account, our results overlap with his. We also provide a fit of the Trojan Horse data that properly takes into account finite residual energy resolution of the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Even a good influenza forecasting model can benefit from internet-based nowcasts, but those benefits are limited

The ability to produce timely and accurate flu forecasts in the United States can significantly impact public health. Augmenting forecasts with internet data has shown promise for improving forecast accuracy and timeliness in controlled settings, but results in practice are less convincing, as models augmented with internet data have not consistently outperformed models without internet data. In this paper, we perform a controlled experiment, taking into account data backfill, to improve clarity on the benefits and limitations of augmenting an already good flu forecasting model with internet-based nowcasts. Here, our results show that a good flu forecasting model can benefit from the augmentation of internet-based nowcasts in practice for all considered public health-relevant forecasting targets. The degree of forecast improvement due to nowcasting, however, is uneven across forecasting targets, with short-term forecasting targets seeing the largest improvements and seasonal targets such as the peak timing and intensity seeing relatively marginal improvements. The uneven forecasting improvements across targets hold even when “perfect” nowcasts are used. These findings suggest that further improvements to flu forecasting, particularly seasonal targets, will need to derive from other, non-nowcasting approaches.

60 APPLIED LIFE SCIENCES↗

The future of FRMAC assessment.

FRMAC was born out of circumstances 25 years ago when 17 federal agencies descended on the states with good intention during the Three-Mile Island nuclear power plant incident. At that time it quickly became evident that a better way was needed to support state and local governments in their time of emergency and recovery process. FRMAC's single voice of Federal support coordinates the multiple agencies that respond to a radiological event. Over the years, FRMAC has exercised, evaluated, and honed its ability to quickly respond to the needs of our communities. As the times have changed, FRMAC has expanded its focus from nuclear power plant incidents, to threats of a terrorist radiological dispersal device (RDD), to the unthinkable - an Improvised nuclear device (IND). And just as having the right tools are part of any trade, FRMAC's tool set has and is evolving to meet contemporary challenges - not just to improve the time it takes to collect data and assess the situation, but to provide a quality and comprehensive product that supports a stressed decision maker, responsible for the protection of the public. Innovations in the movement of data and information have changed our everyday lives. So too, FRMAC is capitalizing on industry innovations to improve the flow of information: from the early predictive models, to streamlining the process of getting data out of the field; to improving the time it takes to get assessed products in to the hands of the decision makers. FRMAC is focusing on the future through the digital age of electronic data processing. Public protective action and dose avoidance is the challenge.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Hybrid Data-Driven and Model-Based Anomaly Detection Scheme for DER Operation: Preprint

This paper proposes a hybrid data and model-based anomaly detection for securing the operation of distributed energy resources (DERs) in distribution grids. Data-driven autoencoders (AE) are set up at the edge level by taking local DER data and detect anomalous operations by leveraging the reconstruction ability. In parallel, model-based state estimation (SE) is running at the system level by taking system models and measurements, the anomalies are identified by analyzing the measurements residual. The hybrid scheme preserves the benefits of both data-driven and model-based analysis and thus improves the robustness and accuracy of anomaly detection. It can be established by getting full use of the existing infrastructures in distribution grids. Numerical tests on a realistic distribution feeder in Southern California highlight the effectiveness as well as benefits of the proposed scheme.

anomaly detection↗

Advanced Fuel Cycle Cost Basis Report: Supporting Document 6 A Proposed Methodology for Transformation of Reactor Cost Data to the ‘What-It-Takes’ Table

Note: This document represents work undertaken to refine the CBR approach for arriving at recommended cost values for the reactor sub-modules. This information is provided to indicate the possible direction of evolution in future CBR updates and encourage comments from CBR users. Since this document was developed concurrent with many of the following R-modules, the methodology was applied only in the analysis of the fast reactor (Module R2) data. In future revisions an attempt will be made to use this methodology uniformly.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Master State Distributed Estimator (masde)

The MSE technology provides a distributed state estimation scheme for power utilities by making it a real time dynamic system, versus the static snapshot method used today. This will allow utilities to verify power grid readings and identify false data on the communication network. The prevailing method of estimation takes all the data from the system into a single load flow equation at the utilities command center. This becomes a large algorithm that is very time consuming to solve, providing the engineers only snap shots of the system. The MFD distributes an algorithm to devises that are already installed at various locations on the power grid. This allows for much faster computer times because the algorithms contain magnitudes less data. When each distributed estimator completes its calculation, it sends the results back to the master device to check against all other distributed estimators.

Reen, DylanW.↗

ATLAS muon data quality with 2010 LHC

ATLAS is a large multipurpose detector, presently in the full operational phase at LHC, the CERN Large Hadron Collider accelerator. The ATLAS Muon Spectrometer has been designed to provide standalone measurement of the muon momentum up to a few TeV with a relative precision better that 10% and to trigger on single muons with transverse momentum down to a few GeV, and an efficiency close to 100%, taking into account the high level background environment, the inhomogeneous magnetic field, and the large size of the apparatus (24 m diameter by 44 m length). ATLAS MS detector has being commissioned using all types of physics data available: cosmic rays and events produced during a few days of LHC single beam operations. This first year of data taking has been of great interest, not only for the physics outcome, but also for operating the system under the environment it was designed for. This paper is describing the design, the implementation as well as the data quality performance achieved during this first year of data taking. We also describe how to reduce the cosmic background contamination in early collisions data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imputation for multisource data with comparison and assessment techniques

Missing data are prevalent issue in analyses involving data collection. The problem of missing data is exacerbated for multisource analysis, where data from multiple sensors are combined to arrive at a single conclusion. In this scenario, it is more likely to occur and can lead to discarding a large amount of data collected; however, the information from observed sensors can be leveraged to estimate those values not observed. We propose two methods for imputation of multisource data, both of which take advantage of potential correlation between data from different sensors, through ridge regression and a state-space model. These methods, as well as the common median imputation, are applied to data collected from a variety of sensors monitoring an experimental facility. Performance of imputation methods is compared with the mean absolute deviation; however, rather than using this metric to solely rank themethods,we also propose an approach to identify significant differences. Imputation techniqueswill also be assessed by their ability to produce appropriate confidence intervals, through coverage and length, around the imputed values. Finally, performance of imputed datasets is compared with a marginalized dataset through a weighted k-means clustering. In general, we found that imputation through a dynamic linearmodel tended to be the most accurate and to produce the most precise confidence intervals, and that imputing the missing values and down weighting them with respect to observed values in the analysis led to the most accurate performance.

97 MATHEMATICS AND COMPUTING↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage [1] with over 2,000 casks already loaded [2]. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980s. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies’ location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988 [3]. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield [4]. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis [5] [6] [7], rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computed Tomography of Dry Cask Storage for Used Fuel

The demand for dry cask storage for used nuclear fuel is on the rise due to the continuous operation of currently existing nuclear plants which are reaching or have reached the capacity of their used fuel pools. Dry cask storage allows used fuel that has already been cooled in the used fuel pool for at least five years to be surrounded by an inert gas inside a specially designed and licensed cask. Currently, 75 of the 78 U.S.A reactor sites either have or are pursuing an independent spent fuel storage installation (ISFSI) for dry cask fuel storage with over 2,000 casks already loaded. Cask loading will only continue to increase until a final repository solution is operational or the U.S. begins to recycle fuel. The challenge of monitoring the condition of the used fuel inside the cask without exposing the used fuel has been apparent since the 1980's. The objective of the University of Florida (UF) project is ultimately to investigate the feasibility of imaging the used fuel assemblies' location and evaluating the inner structural condition using emission source computed tomography (CT). A combination of radiation transport models will be used to simulate gamma-rays and neutrons traversing through the used fuel, structure, and cask body materials. In the simulations, multiple linear detector arrays will record the radiation outside the cask wall and will be placed at various angles in order to model rotating a linear detector array around the entire cask. The combination of data from all the detectors will give the planar radiation projection onto the detectors, more commonly called the Radon transform, of the structure of used fuel assemblies. This project can be processed with filtered back projection or other more advanced reconstructive imaging algorithms to recreate the fuel structures. A majority of the historical work done for used fuel has been on verification, diversion detection, and burnup credit validation in order to meet regulatory guidelines. One of the more commonly used systems for single assembly verification is the Fork Detector developed at Los Alamos National Laboratory in 1988. A group at the Idaho National Laboratory developed a Compton Dry-Cask Imaging Scanner that has the ability to detect empty vs full storage positions but it suffered a setback when transported to the Doel Nuclear Power Plant near Antwerp, Belgium; the system was unable to detect full energy peaks because of the additional scattering caused by a thick ballistic steel shield. As detectors, computational power, and modeling improves, a few groups have leveraged these advancements and started to investigate CT hoping, that despite the difficulties, the technique can give information on fuel condition. So far the groups have mostly limited the tomographic work to a per assembly basis , rather than the full dry cask as the University of Florida plans to investigate. The downsides of CT versus simpler verification and validation are the amount of data required and the time it takes to acquire that data. Given that dry casks are intended to sit undistributed for up to 60 years, a scanning time of several weeks to several months is not unreasonable if such systems do not require human operators beyond the initial setup. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Walén test and de Hoffmann-Teller frame of interplanetary large-amplitude Alfvén waves

In this study, three methods of analysis are compared to test the Walén relation. Method 1 requires a good de Hoffmann-Teller (HT) frame. Method 2 uses three components separately to find the frame that is slightly modified from Method 1. This method is intended to improve the accuracy of the HT frame and able to demonstrate the anisotropic property of the fluctuations. The better the relation is, the closer the slope of a regression fitting the data of plasma versus Alfvén velocities is to 1. However, this criterion is based on an average HT frame, and the fitted slope does not always work for the Walén test because the HT frame can change so fast in the high-speed streams. We propose Method 3 to check the Walén relation using a sequence of data generated by taking the difference of two consecutive values of plasma and Alfvén velocities, respectively. The difference data are independent of the HT frame. We suggest that the ratio of the variances between plasma and Alfvén velocities is a better parameter to qualify the Walén relation. Four cases in two solar wind streams are studied using these three methods. Our results show that when the solar wind HT frame remains stable, all three methods can predict Alfvénic fluctuations well, but Method 3 can better predict the Walén relation when solar wind contains structures with several small streams. A simulated case also demonstrates that Method 3 is better and more robust than Methods 1 and 2. These results are important for a better understanding of Alfvénic fluctuations and turbulence in the solar wind.

79 ASTRONOMY AND ASTROPHYSICS↗

Data Fusion to Enhance Quality Control and Analysis with Instruments at the Marine and Coastal Research Laboratory

Deploying environmental monitoring instruments in the marine environment can be challenging, facing challenges around device survivability, biofouling and corrosion, and consistent data collection. This project explores the use of data fusion – the process of integrating multiple data sources to produce more consistent, accurate, and useful information – to build a consistent long-term monitoring system at the Marine and Coastal Research Laboratory (MCRL) in Sequim, Washington. Unused instruments that had been acquired from past projects were inventoried and deployments planned on the MCRL pier and floating dock. A total of 8 instruments were deployed including a tide gauge, hydrophone, acoustic Doppler current profiler (ADCP), photosynthetically active radiation (PAR) sensors, meteorological station, and three water quality sensors. Deployments were planned to be well-protected around the pier structure and a maintenance schedule was created for cleaning and recalibration. An automated data pipeline was created to aggregate data on edge computers that push data to Amazon Web Services (AWS) cloud storage every 15 minutes, performing automated quality control and data transformations using the Time Series Data Analytical Toolkit (TSDAT). Continued efforts are underway to maintain this system into the future, take a data-driven approach to maintenance scheduling, improve the reliability of the system, and share the data with a variety of end-users.

54 ENVIRONMENTAL SCIENCES↗

Multiresolution 3D-DenseNet for Chemical Shift Prediction in NMR Crystallography

We have developed a deep learning algorithm for chemical shift prediction for atoms in molecular crystals that utilizes an atom-centered Gaussian density model for the 3D data representation of a molecule. We define multiple channels that describe different spatial resolutions for each atom type that utilizes cropping, pooling, and concatenation to create a multiresolution 3D-DenseNet architecture (MR-3D-DenseNet). Because the training and testing time scale linearly with the number of samples, the MR-3D-DenseNet can exploit data augmentation that takes into account the property of rotational invariance of the chemical shifts, thereby also increasing the size of the training data set by an order of magnitude without additional cost. We obtain very good agreement for 13 C, 15 N, and 17 O chemical shifts when compared to ab initio quantum chemistry methods, with the highest accuracy found for 1 H chemical shifts that is comparable to the error between the ab initio results and experimental measurements. Principal component analysis (PCA) is used to both understand these greatly improved predictions for 1 H , as well as indicating that chemical shift prediction for 13 C, 15 N, and 17 O, which have far fewer training environments than the 1 H atom type, will improve once more unique training samples are made available to exploit the deep network architecture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A direct electron detector for time-resolved MeV electron microscopy

The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.

36 MATERIALS SCIENCE↗