Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 {mu}s time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of two color laser diagnostics for the ITER poloidal polarimeter

Two color laser diagnostics using terahertz laser sources are under development for a high performance operation of the Large Helical Device and for future fusion devices such as ITER. So far, we have achieved high power laser oscillation lines simultaneously oscillating at 57.2 and 47.7 {mu}m by using a twin optically pumped CH{sub 3}OD laser, and confirmed the original function, compensation of mechanical vibration, of the two color laser interferometer. In this article, application of the two color laser diagnostics to the ITER poloidal polarimeter and recent hardware developments will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics design for steady-state operation of the Wendelstein 7-X stellarator

The status of the diagnostic developments for the quasistationary operable stellarator Wendelstein 7-X (maximum pulse length of 30 min at 10 MW ECRH heating at 140 GHz) will be reported on. Significant emphasis is being given to the issue of ECRH stray radiation shielding of in-vessel diagnostic components, which will be critical at high density operation requiring O2 and OXB heating.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation Request Gatekeeper: A software system for remote access control of diagnostic instruments in fusion experiments

Tokamak diagnostic settings are repeatedly modified to meet the changing needs of each experiment. Enabling the remote diagnostic control has significant challenges due to security and efficiency requirements. The Operation Request Gatekeeper (ORG) is a software system that addresses the challenges of remotely but securely submitting modification requests. The ORG provides a framework for screening all the requests before they enter the secure machine zone and are executed by performing user authentication and authorization, grammar validation, and validity checks. A prototype ORG was developed for the ITER CODAC that satisfies their initial requirements for remote request submission and has been tested with remote control of the KSTAR Plasma Control System. This paper describes the software design principles and implementation of ORG as well as worldwide test results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion product diagnostics planned for Large Helical Device deuterium experiment

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt {gamma}-ray diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress of development of Thomson scattering diagnostic system on COMPASS

A new Thomson scattering diagnostic system has been designed and is being built now on the COMPASS tokamak at the Institute of Plasma Physics ASCR in Prague (IPP Prague) in the Czech Republic. This contribution focuses on design, development, and installation of the light collection and detection system. High spatial resolution of 3 mm will be achieved by a combination of design of collection optics and connected polychromators. Imaging characteristics of both core and edge plasma collection objectives are described and fiber backplane design is presented. Several calibration procedures are discussed. The operational deployment of the Thomson scattering diagnostic is planned by the end of 2010.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stray light analysis for the Thomson scattering diagnostic of the ETE Tokamak

Thomson scattering is a well-established diagnostic for measuring local electron temperature and density in fusion plasma, but this technique is particularly difficult to implement due to stray light that can easily mask the scattered signal from plasma. To mitigate this problem in the multipoint Thomson scattering system implemented at the ETE (Experimento Tokamak Esferico) a detailed stray light analysis was performed. The diagnostic system was simulated in ZEMAX software and scattering profiles of the mechanical parts were measured in the laboratory in order to have near realistic results. From simulation, it was possible to identify the main points that contribute to the stray signals and changes in the dump were implemented reducing the stray light signals up to 60 times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge Diagnostics for Laser Plasma Accelerators

The electron energy dependence of a scintillating screen (Lanex Fast) was studied with sub-nanosecond electron beams ranging from 106 MeV to 1522 MeV at the Lawrence Berkeley National Laboratory Advanced Light Source (ALS) synchrotron booster accelerator. The sensitivity of the Lanex Fast decreased by 1% per 100 MeV increase of the energy. The linear response of the screen against the charge was verified with charge density and intensity up to 160 pC/mm{sup 2} and 0.4 pC/ps/mm{sup 2}, respectively. For electron beams from the laser plasma accelerator, a comprehensive study of charge diagnostics has been performed using a Lanex screen, an integrating current transformer, and an activation based measurement. The charge measured by each diagnostic was found to be within {+-}10%.

43 PARTICLE ACCELERATORS↗

A diagnostic system for electrical faults in a high current discharge plasma setup

A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is {approx}4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgraded multipulse laser and multipoint Thomson scattering diagnostics on EAST

Recently a new Thomson scattering diagnostic system was upgraded in EAST tokamak experiment using a multipulse Nd:YAG (neodymium--yttrium aluminium garnet) laser and a multipoint observation volumes. This diagnostic uses a new optical laser alignment technique that was made to determine accurately the laser position, and a new lens collection system that enables the measurement of wider plasma's object. A composite control system made we can get the results in several seconds. Furthermore, a new data processing method was adopted for much exact results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of the focusing multi-slit ion optical system at RUssian Diagnostic Injector (RUDI)

The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35 deg. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.

43 PARTICLE ACCELERATORS↗

A Langmuir probe diagnostic for time-of-flight measurements of transient plasmas produced by high-energy laser ablation

We discuss here the development of a Langmuir probe (LP) diagnostic to examine high-density, high-temperature inhomogeneous plasmas such as those that can be created at the University of Rochester's Laboratory for Laser Energetics OMEGA facility. We have configured our diagnostic to examine the velocity of the plasma expanding from the target. We observe velocities of approximately 16-17 cm/{mu}s, with individual LP currents displaying complex structures, perhaps due to the multiple atomic species and ionization states that exist.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent improvements of the JET lithium beam diagnostic

A 60 kV neutral lithium diagnostic beam probes the edge plasma of JET for the measurement of electron density profiles. This paper describes recent enhancements of the diagnostic setup, new procedures for calibration and protection measures for the lithium ion gun during massive gas puffs for disruption mitigation. New light splitting optics allow in parallel beam emission measurements with a new double entrance slit CCD spectrometer (spectrally resolved) and a new interference filter avalanche photodiode camera (fast density and fluctuation studies).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wall current probe: A non-invasive in situ plasma diagnostic for space and time resolved current density distribution measurement

In the context of low temperature plasma research, we propose a wall current probe to determine the local charged particle fluxes flowing to the chamber walls. This non-intrusive planar probe consists of an array of electrode elements which can be individually biased and for which the current can be measured separately. We detail the probe properties and present the ability of the diagnostic to be used as a space and time resolved measurement of the ion and electron current density at the chamber walls. This diagnostic will be relevant to study the electron transport in magnetized low-pressure plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.

43 PARTICLE ACCELERATORS↗

Diode pumped solid state kilohertz disk laser system for time-resolved combustion diagnostics under microgravity at the drop tower Bremen

We describe a specially designed diode pumped solid state laser system based on the disk laser architecture for combustion diagnostics under microgravity (μg) conditions at the drop tower in Bremen. The two-stage oscillator-amplifier-system provides an excellent beam profile (TEM{sub 00}) at narrowband operation (Δλ < 1 pm) and is tunable from 1018 nm to 1052 nm. The laser repetition rate of up to 4 kHz at pulse durations of 10 ns enables the tracking of processes on a millisecond time scale. Depending on the specific issue it is possible to convert the output radiation up to the fourth harmonic around 257 nm. The very compact laser system is integrated in a slightly modified drop capsule and withstands decelerations of up to 50 g (>11 ms). At first the concept of the two-stage disk laser is briefly explained, followed by a detailed description of the disk laser adaption to the drop tower requirements with special focus on the intended use under μg conditions. In order to demonstrate the capabilities of the capsule laser as a tool for μg combustion diagnostics, we finally present an investigation of the precursor-reactions before the droplet ignition using 2D imaging of the Laser Induced Fluorescence of formaldehyde.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Neutron bang time diagnostic system on Shenguang-III prototype

A neutron bang time (NBT) diagnostic system has been implemented on Shenguang-III prototype. The bang time diagnostic system is based on a sensitive fusion neutron detector, which consists of a plastic scintillator and a micro-channel plate photomultiplier tube (PMT). An optical fiber bundle is used to couple the scintillator and the PMT. The bang time system is able to measure bang time above a neutron yield of 10{sup 7}. Bang times and start time of laser were related by probing x-ray pulses produced by 200 ps laser irradiating golden targets. Timing accuracy of the NBT is better than 60 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stark broadening for diagnostics of the electron density in non-equilibrium plasma utilizing isotope hydrogen alpha lines

Two Stark broadening parameters including FWHM (full width at half maximum) and FWHA (full width at half area) of isotope hydrogen alpha lines are simultaneously introduced to determine the electron density of a pulsed vacuum arc jet. To estimate the gas temperature, the rotational temperature of the C{sub 2} Swan system is fit to 2500 ± 100 K. A modified Boltzmann-plot method with b{sub i}-factor is introduced to determine the modified electron temperature. The comparison between results of atomic and ionic lines indicates the jet is in partial local thermodynamic equilibrium and the electron temperature is close to 13 000 ± 400 K. Based on the computational results of Gig-Card calculation, a simple and precise interpolation algorithm for the discrete-points tables can be constructed to obtain the traditional n{sub e}-T{sub e} diagnostic maps of two Stark broadening parameters. The results from FWHA formula by the direct use of FWHM = FWHA and these from the diagnostic map are different. It can be attributed to the imprecise FWHA formula form and the deviation between FWHM and FWHA. The variation of the reduced mass pair due to the non-equilibrium effect contributes to the difference of the results derived from two hydrogen isotope alpha lines. Based on the Stark broadening analysis in this work, a corrected method is set up to determine n{sub e} of (1.10 ± 0.08) × 10{sup 21} m{sup −3}, the reference reduced mass μ{sub 0} pair of (3.30 ± 0.82 and 1.65 ± 0.41), and the ion kinetic temperature of 7900 ± 1800 K.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗