Search NASA⌕ Search

SEARCH · Search NASA

Results for “document analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ESS-DIVE Reporting Format for Amplicon Abundance Table

While standardized sequencing data is available in public repositories and efforts such as MIxS for common sample collection and processing metadata are well established, the lack of common bioinformatic processing metadata has hindered the ability to do large-scale metaanalyses and the potential for data re-use by non-experts such as ecosystem, watershed, or earth system modelers. To address this need for Department of Energy researchers, we have developed an amplicon reporting format which captures both sample preparation and bioinformatic processing metadata and stores processed amplicon data as a paired abundance table and sequencing file to maximize the potential for re-use of these data. To aid in the adoption of accessible and reproducible analysis workflows, this reporting format was developed in concert with amplicon functionality within the Department of Energy’s Systems Biology Knowledgebase (KBase) to ensure common data and metadata requirements and facilitate seamless transfer between these platforms.This dataset contains support documentation for the amplicon reporting format (README.md and instructions.md), templates for both bioinformatic and sequencing metadata (amplicon_bioinformatic_metadata_template_2021_10_03.csv and amplicon_sequencing_metadata_template_2021_10_03.csv), a crosswalk indicating how this reporting format relates to the current MIxS format (ESSDIVE-MIxS_crosswalk.csv), a list of available instrument terms (amplicon_seq_instrument_terms_2021_10_03.csv), a map between QIIME2 parameter settings and metadata fields (amplicon_qiime2_plugin_metadata_map.csv), a data dictionary (amplicon_CSV_dd.csv), and file-level metadata (amplicon_FLMD.csv).

54 ENVIRONMENTAL SCIENCES↗

Evaluating Precision of Measured Radionuclide Ambient Air Concentrations

According to AIRNET – Quality Assurance Project Plan for the Radiological Air Sampling Network, SOP-5140, Revision 2 (to become EPC-CP-PIP-5140): “The regulation 40 CFR Part 61.93 requires that the system be able to readily detect a dose of 1.0 mrem above background. Following statistical principles and assuming 95% confidence for such a measurement, we require that 95% of all measurements must fall within two standard deviations of the mean. This represents the minimum acceptable precision for decision making.” An independent assessment of the Rad-NESHAP program completed in early 2019 found that no documentation existed proving that the Airnet data meets the precision defined above. Therefore, to address this particular finding, Airnet concentration data was pulled from the Environmental Information Management (EIM), a cloud-based database maintained by Locus Technologies, for analysis.

54 ENVIRONMENTAL SCIENCES↗

Best Practices for Timing Attack Mitigation

GPS signals play essential roles in the electric subsector by providing precision timing used to synchronize and record measurements from a range of equipment. However, previous research has demonstrated that GPS signals can be spoofed or jammed relatively easily in order to interfere with timing-reliant equipment. This document outlines utility best practices for mitigating against timing attacks in the electric subsector based on an assessment of the difficulty and impact of realistic timing attacks and testing of the effectiveness of technologies capable of mitigating them. This analysis builds on research establishing the vulnerability of GPS-reliant timing equipment to jamming and spoofing by elaborating the difficulty, consequences, and mitigations for timing attacks that adversaries might realistically attempt. While timing attacks are relatively low-cost, low-sophistication, and capable of systemic consequences in the electric subsector, they can be effectively mitigated through well-targeted and diverse mitigations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equipment Testing Environment (ETE) Process Specification

This document is intended to be utilized with the Equipment Test Environment being developed to provide a standard process by which the ETE can be validated. The ETE is developed with the intent of establishing cyber intrusion, data collection and through automation provide objective goals that provide repeatability. This testing process is being developed to interface with the Technical Area V physical protection system. The document will overview the testing structure, interfaces, device and network logging and data capture. Additionally, it will cover the testing procedure, criteria and constraints necessary to properly capture data and logs and record them for experimental data capture and analysis.

97 MATHEMATICS AND COMPUTING↗

Updated Results of the Nuclear Accident Dosimetry Intercomparison at the Armed Forces Radiobiology Research Institute’s TRIGA Reactor (IER-602 CED-4a Report)

The IER-602 3b document (Angus, et al. 2024) reported the initial, 24-hour results of the international nuclear accident intercomparison, which took place at the Armed Forces Radiobiological Research Institute during June 24-28, 2024. This report provides updated results and further analysis of the intercomparison.

61 RADIATION PROTECTION AND DOSIMETRY↗

Workbooks for Cambium 2024 Data

These workbooks contain a subset of cost and emissions data from the 2024 Cambium datasets, with levelization calculations to assist users in translating Cambium’s year-over-year values to a representative value for a user-specified project timeline. These workbooks provide modeled data for 18 GEA regions covering the contiguous United States, projected forward through 2050. Mappings of these regions to ZIP codes and counties is given within this workbook in the corresponding tabs. For the full Cambium 2024 data sets, see the Cambium 2024 project on NREL's Scenario Viewer. For more details on input assumptions and methodology see the associated report: Cambium 2024 Scenario Descriptions and Documentation. Users are advised to review section 4 of the report, which discusses limitations and caveats of the data. This data is planned to be updated annually. Information on the latest versions can be found on the NREL energy analysis page on Cambium.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of Polyurethane and Fire-Retardant Foams as a Radiological Contamination Fixatives - 20202

Fixation of radiological contamination in decommissioning and deactivation can reduce worker risk, and mitigate potentially hazardous conditions; however, nearly every marketed contamination fixative has been found to be flammable, a significant concern in radiological facilities. Coupled with this, industry fixatives are normally used as a thin coating which can present problems when attempting to stabilize irregular void spaces or areas that are difficult to access and ensure full coverage. To this end, Savannah River National Laboratory (SRNL), in conjunction with Florida International University (FIU), have begun investigating the applicability of polyurethane based foaming materials, which will expand to fill a given asymmetric volume and provide fire retardancy to ensure no release of contamination in the event of a facility fire. Commercial foams undergo exothermic reactions resulting in gaseous release that subsequently causes the curing foam material to expand. Heat generation during curing can potentially compromise rubber parts of an enclosure, a significant concern in nuclear facilities. To mitigate large body heat generation, SRNL has also examined multiple layering of the material to ensure compatibility of the curing material with a previously cured body of the same material. Environmental studies were also completed in order to determine the influence on polyurethane based foams curing process. These studies showed that nearly half of the materials tested delaminated from a cured body of the same material, a property not discussed in commercially available documentation on the products. Of note was the compatibility of the foaming material with the substrate, depending on the type material that the foam was cured in/on, significant delamination could occur. Mechanical testing via tensile pull tester, dynamic mechanical analysis (DMA), and thermogravimetric analysis (TGA) was also performed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

MSR Proliferation Resistance and Physical Protection White Paper

This document represents the status of Proliferation Resistance and Physical Protection (PR&PP) characteristics for the Molten Salt Reactor designs selected by the Generation IV International Forum (GIF) Molten Salt Reactor (MSR) provisional System Steering Committee (pSSC) as representatives of three broad classes of MSRs. The three classes of MSRs are: (1) Liquid-fueled with integrated salt processing, (2) Liquid-fueled without integrated salt processing, (3) Solid-fueled with salt coolant. The intent is to generate preliminary information about the PR&PP merits of the MSR Reactor Technology and to provide insights for optimizing their PR&PP performance for the benefit of MSR system designers. It updates the MSR analysis published in the 2011 report “Proliferation Resistance and Physical Protection of the Six Generation IV Nuclear Energy Systems”, prepared Jointly by the Proliferation Resistance and Physical Protection Working Group (PRPPWG) and the System Steering Committees of the Generation IV International Forum, taking into account the evolution of both the systems and the GIF R&D activities since its publication. The document, prepared jointly by the GIF PRPPWG and the GIF MSR pSSC, follows the high-level paradigm of the GIF Proliferation Resistance and Physical Protection Evaluation Methodology to investigate the Proliferation Resistance and Physical Protection features of the GIF MSR representative designs. For PR, the document analyses and discusses the proliferation resistance aspects in terms of robustness against State-based threats associated with diversion of materials, misuse of facilities, breakout scenarios, and production in clandestine facilities. Similarly, for physical protection, the document discusses the robustness against theft of material and sabotage by non-State actors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Minimal Information Set To Enable Verifiable Theoretical Battery Research

Batteries are an enabling technology for addressing sustainability through the electrification of various forms of transportation (1) and grid storage. (2) Batteries are truly multi-scale, multi-physics devices, and accordingly various theoretical descriptions exist to understand their behavior (3-5) ranging from atomistic details to techno-economic trends. As we explore advanced battery chemistries (6,7) or previously inaccessible aspects of existing ones, (8-10) new theories are required to drive decisions. (11-13) The decisions are influenced by the limitations of the underlying theory. Advanced theories used to understand battery phenomena are complicated and require substantial effort to reproduce. However, such constraints should not limit the insights from these theories. We can strive to make the theoretical research verifiable such that any battery stakeholder can assess the veracity of new theories, sophisticated simulations or elaborate analyses. We distinguish verifiability, which amounts to “Can I trust the results, conclusions and insights and identify the context where they are relevant?”, from reproducibility, which ensures “Would I get the same results if I followed the same steps?” With this motivation, we propose a checklist to guide future reports of theoretical battery research in Table 1. We hereafter discuss our thoughts leading to this and how it helps to consistently document necessary details while allowing complete freedom for creativity of individual researchers. Given the differences between experimental and theoretical studies, the proposed checklist differs from its experimental counterparts. (14,15) This checklist covers all flavors of theoretical battery research, ranging from atomic/molecular calculations (16-19) to mesoscale (20,21) and continuum-scale interactions, (9,22) and techno-economic analysis. (23,24) Finally, as more and more experimental studies analyze raw data, (25) we feel this checklist would be broadly relevant.

25 ENERGY STORAGE↗

End-Use Savings Shapes Measure Documentation: Electric Cooking Equipment

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past three years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. “Measures” refers to energy efficiency variables that can be applied to buildings during modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SELKIE Spectral Extraction Results

This document describes results from the WAMOR Chesapeake Bay collection in October 2024, a data collection from the Arkeus HSOR hyperspectral sensor. The calibration array was staged at USCG Station Little Creek, Virginia. With the provided HSOR imagery and data, our analysis does not show a capability to effectively detect materials of interest from non-materials of interest as well as differentiate materials of interest from each other, the materials of interest being polypropylene, polyester, and cotton. The fundamental reasons are (1) the spectral bands of HSOR do not reside in specific wavelength locations to allow for material identification and (2) the provided imagery appears to not have consistent band-to-band relationships indicative of a lack of calibration (gain/offsets) or some other calibration issues. With regard to analyzing a subset of the delivered HSOR, HSOR can make general statements about materials not being water and have the capability to make color assessments.

36 MATERIALS SCIENCE↗

Hand Calculations for Nuclear Criticality Safety – Primer Revision

The document “ Hand Calculation Methods for Criticality Safety – A Primer, ” was published by the authors (Los Alamos National Laboratory report LA-14244-M) in December 2006 to provide an overview of the most common hand calculation methods used for criticality safety analysis. Hand calculation methods can be used as a starting point for more advanced calculations, and in many circumstances, they can provide sensitivity and perturbation information quicker than using a criticality code, such as KENO or MCNP. This report has been revised to augment existing basis information and example problems for each of the methods discussed: 1-group and modified 1- group diffusion theory, core-density conversions, buckling conversions, limiting surface density method, density analog method, surface density method, and solid angle method. This primer discusses the applicability of the various methods, illustrates how they are used, and provides an interpretation of the example problem results. The example problems provided are simple, practical problems, and the reference data to solve each example problem is provided. This paper will provide an overview of the Primer revision and how it can be useful for new Nuclear Criticality Safety practitioners.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hand Calculations for Nuclear Criticality Safety — Primer Revision [Abstract]

The document “ Hand Calculation Methods for Criticality Safety –A Primer, ” was published by the authors (Los Alamos National Laboratory report LA-14244-M) in December 2006 to provide an overview of the most common hand calculation methods used for criticality safety analysis. Hand calculation methods can be used as a starting point for more advanced calculations, and in many circumstances, they can provide sensitivity and perturbation information quicker than using a criticality code, such as KENO or MCNP. This report has been revised to augment existing basis information and example problems for each of the methods discussed: 1-group and modified 1-group diffusion theory, core-density conversions, buckling conversions, limiting surface density method, density analog method, surface density method, and solid angle method. This primer discusses the applicability of the various methods, illustrates how they are used, and provides an interpretation of the example problem results. The example problems provided are simple, practical problems, and the reference data to solve each example problem is provided. This paper will provide an overview of the Primer revision and how it can be useful for new Nuclear Criticality Safety practitioners.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

Infrastructure improvements in the National Reactor Innovation Center Virtual Test Bed

The National Reactor Innovation Center’s (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. The VTB is being developed in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished via three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: • A documentation website detailing the models: https://mooseframework.inl.gov/virtual_test_bed • A GitHub repository that hosts the corresponding files: https://github.com/idaholab/virtual_test_bed. This paper presents the infrastructure added to the VTB in the last two fiscal years. Additional information about the VTB can be found in various publications [1, 2, 3, 4, 5, 6, 7, 8].

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗