Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrically”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Engineered Solutions Group's SMR Containment Cable and Electrical Penetration Assembly System

GAIN Project CRADA Number NFE-21-08839, entitled “SMR Containment Cable and EPA System” was initiated by the partnership of Oak Ridge National Laboratory (ORNL) and Engineered Solutions Group (ESG) to test an ESG-designed Electrical Penetration Assembly and Containment Cabling System Qualified for not only legacy LWR designs, but also Small Modular Reactors designs currently being designed by several different suppliers. This project was undertaken to fill the equipment gap of EPA and Cabling Systems that require much more severe environmental requirements than legacy plant applications present due to their smaller containment volumes that result in high energy densities compared to legacy designs. This high energy density results in severe accident environments and more severe normal operating conditions as well. We developed two approaches to qualify Electrical Penetration Assembly (EPA) and Containment Cabling Systems for SMRs and Advanced Reactors. We take into consideration the more severe environmental parameters found with SMR designs. The system will need to meet a qualification test program addressing wear/cyclic aging, potential radiation exposure, thermal aging, vibration aging, thermal cycling, seismic qualification, electrical fault testing (per IEEE 317) and accident simulation. The equipment must meet the requirements of 10CFR50.49, GDC 50 in 10CFR50 Appendix A, and 10CFR50 Appendix J. NRC Regulatory Guides (RGs) identify an acceptable way of meeting regulatory requirements. RGs frequently endorse a standard for meeting these requirements. Specific to this review, equipment would be qualified in accordance with the following IEEE Standards. • IEEE 317-2013 (Electrical Penetration Assemblies), which is endorsed by RG 1.63, Rev. 3, • IEEE 323-2003 and the more current IEC/IEEE 60780-323 (Environmental Qualification of 1E Equipment) which is endorsed by RG 1.89. IEEE 323-2003 is endorsed by RG 1.209, • IEEE 344-2020 (Seismic Qualification. The 2013 version endorsed by RG 1.100, Rev. 4, with exceptions), • IEEE 383-2015 (Electrical Cables) (which is endorsed by RG 1.189 Rev. 4 and the -2003 version endorsed by RG 1.211 rev. 0), • IEEE 572-2019 (Electrical Connectors and Assemblies), which is endorsed by 1.156 Rev 1, and • [IEEE 1202 (endorsed by RG 1.189) would normally be applicable but the advanced cable designs are impervious to this cable flame test.] The primary goal of such a program is to provide an EPA design that can meet the qualification requirements for all legacy light water reactor plants currently operating as well as new plant designs including light water Small Modular Reactors. Thus, these requirements are applicable to plants licensed under 10CFR50 and 10CFR52. Other reactor designs may be evaluated, and this test system and qualification method applied to those applications if the requirements would satisfy the requirements of the intended plant. A secondary benefit of this work is to document some of the history and background in these requirements as there have been recent delays in an SMR licensing process due to NRC Requests for Additional Information in this subject matter area.

42 ENGINEERING↗

Energy Storage and the Law of Averages: How Storage Can Make Electricity More Affordable

The electric grid is planned, built, and operated to satisfy peak demand. But because peak demand only occurs for a few hours per year, customers end up paying full price for grid infrastructure that is only used for a small fraction of the year—an increasingly expensive proposition as peak demand continues to grow and more infrastructure is required to meet it. The emergence of cost-competitive energy storage technologies in recent years, however, offers the potential for a grid that is planned, built, and operated based on average demand. By strategically siting and operating energy storage throughout the electric grid, excess generation in low-demand periods can be captured and stored near customers, which then reduces the amount of electricity that needs to be generated and moved through the transmission and distribution systems during high-demand periods. This paper describes these potential benefits, supported by real-world examples of energy storage projects that have created cost savings, which points to the potential for profound and far-reaching reductions in the cost of electricity if energy storage technologies are deployed at scale throughout the electric grid. These examples will be of use to system planners and operators, utility regulators, decision makers, and stakeholders in those processes as they look for opportunities to reduce the cost of electricity in their respective systems and jurisdictions.

25 ENERGY STORAGE↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determining critical points to control electric lighting to meet circadian lighting requirements and minimize energy use

Designing electric lighting systems to meet circadian lighting requirements may raise light levels and consequently energy use compared to existing practices. To reduce energy use, electric lighting can be controlled to be dimmed or turned off when sufficient daylight levels are available in space. This requires input from one or a few critical measurement points. However, it is unclear how critical points can be determined to ensure that all occupants receive the needed light levels while reducing electric lighting energy. This paper discusses three approaches for selecting critical points and utilizes annual daylight simulations modified to account for sky spectra, and coupled with spectral electric lighting simulations. Among the three evaluated approaches, the use of continuous daylight autonomy (modified to use EML measured at eye positions) is helpful for estimating electric lighting energy for dimmable electric lighting systems, and for identifying energy-saving strategies.

Abboushi, Belal K.↗

A Comparison of Power Take-Off Architectures for Wave-Powered Reverse Osmosis Desalination of Seawater with Co-Production of Electricity

Several power take-off (PTO) architectures for wave-powered reverse osmosis (RO) desalination of seawater are introduced and compared based on the annual average freshwater production and the size of the components, which strongly relate to the costs of the system. The set of architectures compared includes a novel series-type PTO architecture not previously considered. These seawater hydraulic PTO architectures are composed of a WEC-driven pump, an RO module, an intake charge pump driven by an electric motor, and a hydraulic motor driving an electric generator for electric power production. This study is performed using an efficient two-way coupled steady-state model for the average performance of the system in a given sea state, including freshwater permeate production, electric power production, and electric power consumption. A multi-objective design problem is formulated for the purposes of this comparative study, with the objectives of maximizing annual freshwater production, minimizing the displacement of the WEC-driven pump, and minimizing the installed RO membrane area. This establishes a framework for comparison in the absence of a mature techno-economic model. The requirement that the system produces enough electric power to meet its consumption is applied as a constraint on the operation of the system. The oscillating wave surge converter Oyster 1 is assumed as the WEC. Weights on performance of the system in a given sea state are based on historical data from Humboldt Bay, CA. This study finds that (1) architectures in a series configuration allow for a reduction in the WEC-driven pump size of 59–92% compared to prior work, (2) varying the displacement of the WEC-driven pump between sea conditions does not provide any significant advantage in performance, and (3) varying the active RO membrane area between sea condition offers improvements between 7% and 41% in each design objective.

Energy & Fuels↗

An Advanced Synchronized Time Digital Grid Twin Testbed for Relay Misoperation Analysis of Electrical Fault Type Detection Algorithms

Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Observed relationships between electric fields and auroral particle precipitation

Simultaneous electric field and plasma observations with the low altitude, polar orbiting satellite Injun (Hawkeye) 5 provided a comprehensive survey of convection electric fields and their association with magnetospheric plasma phenomena. The most prominent features of the convection electric fields are reversals located at high magnetic latitudes, with generally anti sunward convection poleward convection equatorward of the electric field reversal location. The electric field reversal is interpreted as the boundary between open and closed magnetic field lines. To investigate the electric field and plasma interrelationships during a polar magnetic substorm, a series of passes obtained prior to and during a substrom is presented. Large, anti sunward convection velocities were detected over the polar cap several tens of minutes before the onset of the expansive phase of the substrom. These convection velocities gradually decreased during the decay phase of the substrom. Measurements of enhanced anti sunward flow over the polar cap region are generally consistent with concepts of the origin of substroms.

Gurnett, D. A.↗

Rocket borne instrument to measure electric fields inside electrified clouds

An apparatus for measuring the electric field in the atmosphere which includes a pair of sensors carried on a rocket for sensing the voltages in the atmosphere being measured is described. One of the sensors is an elongated probe with a fine point which causes a corona current to be produced as it passes through the electric field. An electric circuit is coupled between the probe and the other sensor and includes a high ohm resistor which linearizes the relationship between the corona current and the electric field being measured. A relaxation oscillator and transmitter are provided for generating and transmitting an electric signal having a frequency corresponding to the magnitude of the electric field.

Ruhnke, L. H.↗

Relations between ionospheric electric fields and energetic trapped and precipitating electrons.

Balloon-borne electric field and X ray detectors have been flown from Fort Churchill and from near the foot of the magnetic field line on which the ATS 5 satellite is located in order to obtain satellite and balloon measurements of trapped and precipitating particles and to compare them with balloon measurements of the ionospheric electric field. The approximately 80 hours of coordinated data show that nighttime precipitation events (1) are preceded by enhancements of the westward component of ionospheric electric field about 70% of the time, (2) cause the westward electric field strength to decrease about 70% of the time, (3) are unrelated to variations of the southward component of the ionospheric electric field. The westward electric field enhancement before many precipitation events occurs when the trapped electron flux is at or near the stable trapping limit.

Mozer, F. S.↗

The impact of space electric field research on atmospheric studies

Space measurements of electric fields have provided instrumentation for measuring atmospheric parameters and a better basis for understanding the electrical coupling between the magnetosphere and the atmosphere. Applications of an incoherent scatter radar (developed for ionospheric electric field research) to the measurement of atmospheric winds and turbulence and of Langmuir double probes (also developed for space research) for measurement of atmospheric electric fields are described. The increased knowledge of magnetospheric electric fields has focused attention on the electrical coupling between the magnetosphere and the atmosphere with conclusions that should considerably modify previous physical concepts in both domains.

Mozer, F. S.↗

Comparison of high-latitude and mid-latitude ionospheric electric fields

Simultaneous measurements of the F region electric field by the incoherent scatter technique have been made at Chatanika, Alaska (65.1 deg N, 147.5 deg W), and Millstone Hill, Massachusetts (42.6 deg N, 71.5 deg W), on July 18-19 and Aug. 7-8, 1973. Good correlation was observed in the time variation of the perpendicular electric field at the two stations. Magnetic conditions for these days were relatively quiet with some variations evident from the high-latitude magnetograms and the Chatanika radar, but no distinct effect appeared on the mid-latitude magnetograms. Since magnetospheric electric fields are thought to be the source of high-latitude electric fields such as those observed at Chatanika, the good correlation in the perpendicular electric field for the two stations indicates that the magnetospheric originated electric fields have an appreciable effect down to at least L equals 3.2.

Carpenter, L. A.↗

Effect of electric fields on the daytime high-latitude E and F regions

We have obtained solutions of the coupled continuity, momentum, and energy equations for NO(+), O(+), and O2(+) ions for conditions appropriate to the daytime high-latitude E and F regions. Owing to the rapid increase of the reaction O(+) + N2 yielding NO(+) + N with ion energy, high-latitude electric fields and consequent perpendicular-E x B drifts deplete O(+) in favor of NO(+). For electric field strengths less than about 10 mV/m the depletion of O(+) is small, and the altitude profiles of ion density are similar to those found at mid-latitudes. However, for moderate electric field strengths (50 mV/m), NO(+) is substantially increased in relation to O(+) and becomes an important ion throughout the F region. For large electric fields (200 mV/m), NO(+) completely dominates the ion composition to at least 600 km, decreasing at high altitudes with a diffusive equilibrium scale height. Since the overall F region electron density decreases markedly with increasing electric field strength, it appears that high-latitude, daytime electron density troughs are directly related to the presence of ionospheric electric fields.

Schunk, R. W.↗

The large-scale ionospheric electric field - Its variation with magnetic activity and relation to terrestrial kilometric radiation

Four days of simultaneous auroral zone electric field measurements on balloons flown from six sites spanning 180 deg of magnetic longitude have been analyzed. The average electric field behavior during this magnetically quiet epoch is consistent with earlier single-point measurements, although the average auroral zone electric field was more affected by corotation effects than it was during more disturbed times. When these data, which primarily reflect the large-scale (several hundred kilometer) ionospheric electric field, are mapped to the equator, a steady dawn to dusk component is apparent only on the average, while instantaneously the field is quite variable. The ionospheric electric field during isolated substorms is shown to have differing signatures east and west of 2200 LT. A worldwide positive correlation is shown to exist between the auroral zone electric field strength and the intensity of terrestrial kilometric radiation.

Holzworth, R. H.↗

Electric propulsion for communications satellites

Electric propulsion systems derive their low overall mass, relative to chemical propulsion systems, from an optimized mix of independently controlled power and mass flow rate. A significant reduction in mass can be secured by substituting electric propulsion for conventional hydrazine systems for all the major propulsion tasks of a communications satellite. Additional advantages for all electric propulsion maneuvers are precision location and higher pointing accuracy. Three auxiliary electric propulsion systems are now available for application on communications satellites: the electrically augmented hydrazine system, the Teflon pulsed plasma system, and the mercury ion thruster system. Primary electric propulsion will be available in the mid to late 1980s as a spin-off of NASA's program of interplanetary exploration.

Free, B. A.↗

The convection electric field model for the magnetosphere based on Explorer 45 observations

Large-scale electric fields in the magnetosphere, represented by the scalar potentials of corotation and convection fields, are examined in order to interpret both plasmapause positions at different local times and energetic particle penetrations inside the plasmapause observed by the Explorer 45 (S3-A) dc E field measurements and particle detectors. The Volland-Stern type convection electric field is assumed. A uniform dawn-dusk convection electric field which corresponds to an exponent (gamma) of unity is not consistent with the observational data, but the Volland-Stern model with gamma = 2 more likely represents the convection electric field during the hours of electric field increases during magnetic activity. In the time-independent case, the shape of the plasmapause does not depend on the intensity of the convection electric field, so that by using two plasmapause distances at different local times along the S3 outbound and inbound orbits the shape factor gamma of the convection field could be determined. The average value of gamma for 42 cases was found to be 2.4.

Ejiri, M.↗

Observations of ULF electric field fluctuations in the dayside auroral oval

Electric field oscillations at frequencies centered below 10 Hz were measured by a payload equipped with double-probe electric field detectors which was launched into the dayside auroral oval during the Greenland rocket campaign on January 11, 1975. These oscillations exceeded an amplitude of 3 mV/m broadband and occurred over a period of about 90 s. These oscillations occurred during a proton injection event when the quasi-static electric field was less than 20 mV/m on the average. However, during a brief 2-s interval the electric field exceeded 50 mV/m. Analysis of the amplitude as a function of the spin frequency showed that the electric field was confined to a plane perpendicular to the magnetic field. The power spectrum was of the form f to the -6.5 + or - 1.5 power, where f is the frequency over the range from 8 to 18 Hz. The existence of a large electric field fluctuation in a spatially or temporally confined region of low-amplitude turbulence suggests that this may be an observation of the low-altitude projection of a turbulent region associated with electrostatic shocks which have recently been observed at higher altitudes.

Temerin, M.↗

Electrical rotary joint apparatus for large space structures

A structural array and electrical rotary joint for transmitting an electrical power between large space structures having relative rotational movement is disclosed which includes large support framework structures which rotate relative to one another about a common axis of rotation. A rotary interface joint is defined between the structures. A cylindrical hub member is carried by one structure and a cylindrical hub member is carried by a support structure with a third hub member being concentrically within a fourth hub member for relative rotation. Tension connecting cables connect hub members with their associated outer structures whereby relative rotational movement between the structures is transmitted to the cylindrical hub members for unitary motion therewith. Electrical conductor brush members are carried by one hub and electrical contact rings are carried by another hub member in sliding electrical contact with the brushes for transmission of electrical power during relative rotational movement between the two support structures.

Belew, R. R.↗