Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy saving process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Modularity-at-scale for advanced reactors presentation

Modularity options have been limited for traditional nuclear energy deployment due to the conventional light water reactor (LWR) safety requirements, such as high pressure retaining heavy and robust containment structures. However, a relatively new regulatory approach called ‘Functional Containment’ has potential to allow less expensive and more flexible designs for non-LWRs. Functional containment provides flexibility in design and deployment based on risk-informed and performance-based criteria, so that reactors are not over-designed. Non-nuclear industry has successfully used modular design approaches in automotive, aerospace, chemical processing, building construction, and ship building. These industries have shown that modular construction reduces construction time by around 30% - 50% compared to the conventional stick-built approach. The nuclear industry can use similar approaches to reduce construction time and costs, balanced with safety requirements, using the functional containment approach. This paper discussing the background of modularity in nuclear energy, examples of less learned, modularity approaches in non-nuclear industries and the potential of cost and schedule savings through the emerging regulatory design flexibilities potentially enabling combination of modular deployment at different scales.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IDAES-PSE 2.7.0 Release

The Institute for the Design of Advanced Energy Systems (IDAES) Integrated Platform is a versatile computational environment offering extensive process systems engineering (PSE) capabilities for optimizing the design and operation of complex, interacting technologies and systems. IDAES enables users to efficiently search vast, complex design spaces to discover the lowest cost solutions while supporting the full process modeling lifecycle, from conceptual design to dynamic optimization and control. The extensible, open platform empowers users to create models of novel processes and rapidly develop custom analyses, workflows, and end-user applications. IDAES-PSE 2.7.0 Release Highlights New features: AutoScaler and CustomScalerBase classes: Such tools are the core of the new scaling framework being implemented in IDAES. Wider adoption of scaling tools among users will result in quicker and more robust model solutions. Scaler for equilibrium reactor and saponification properties: These scaler models are examples to follow for how to use the new scaling tools. ONNX Surrogate support from Optimization & Machine Learning Toolkit (OMLT): ONNX is an open standard format to save and load ML/AI models that is widely supported by all major frameworks. This capability makes it easier for IDAES users to create surrogate models and use them without having to support each framework individually. 1D Membrane Model for CO2 Capture and Utilization: Supports ongoing efforts for modeling and optimizing polymer membrane processes for CO2 capture and conversion into formic acid. StreamScaler unit model: Unrelated to the CustomScalerBase, this unit model allows a stream’s extensive variables to be scaled by a fixed factor. This allows streams being processed by multiple units in parallel to be scaled down to unit scale and scaled back up to process scale. Bug fixes or improvements: Scaling, EoS, Diagnostics tool, Modular Properties, tests & documentation Deprecations: Old Cubic EoS

AS↗

SELF-POWERED WIRELESS SENSOR NODE POWER MODELING BASED ON IEEE 802.11 COMMUNICATION PROTOCOL

Design and technical advancements in sensing, processing, and wireless communication capabilities of small, portable devices known as wireless sensor nodes (WSNs) have drawn extensive research attention and are vastly applied in science and engineering applications. The WSNs are typically powered by a chemical battery source that has a load dependent finite lifetime. Most applications, including the nuclear industry applications, require WSNs to operate for an extended period of time beginning with their deployment. To ensure longevity, it is important to develop self-powered WSNs. The benefit of self-powered WSNs goes far beyond the cost savings of removing the need for cable installation and maintenance. Self-powered WSNs will potentially offer significant expansion in remote monitoring of nuclear facilities, and provide important data on plant equipment and component status during normal operation, as well as in case of abnormal operation, station blackouts or post-accident evaluation. Advancements in power harvesting technologies enable electric energy generation from many sources, including kinetic, thermal, and radiated energy. For the ongoing research at Idaho National Laboratory, a solid-state thermoelectric-based technology, the thermoelectric generator (TEG), is used to convert thermal energy to power a WSN. The design and development of TEGs to power WSNs that would remain active for a long period of time requires comprehensive understanding of WSN operational. This motivates the research in modeling the lifetime, i.e., power consumption, of a WSN by taking into consideration various node and network level activities. A WSN must perform three essential tasks: sense events, perform quick local information processing of sensed events, and wirelessly exchange locally processed data with the base station or with other WSNs in the network. Each task has a power cost per unit tine and an additional cost when switching between tasks. There are number of other considerations that must also be taken into account when computing the power consumption associated with each task. The considerations includes: number of events occurring in a fixed active time period and the duration of each event, event-information processing time, total communication time, number of retransmission, etc. Additionally, at the network level the communication of information data packets between WSNs involves collisions, latency, andretransmission, which result in unanticipated power losses. This paper presents stochastic modeling of power demand for a schedule-driven WSN utilizing Institute of Electrical and Electronics Engineers, IEEE, 802.11 communication protocols. The model captures the generic operation of a schedule-driven WSN when an external event occurs, i.e., sensing, following by processing, and followed by communication. The results are verified via simulation.

IEEE 802.11 Protocol↗

A Review of the Evaluation of Building Energy Code Compliance in the United States

Building energy codes are essential tools for achieving energy efficiency in buildings. However, the full energy savings potential of these codes can only be realized if buildings are constructed in compliance with them. Therefore, evaluating building energy code compliance is crucial in bridging the gap between the energy efficiency requirements set by energy codes and the actualized energy savings achieved. An energy code compliance evaluation serves as a mechanism to assess construction practices, evaluate the effectiveness of code enforcement, identify gaps in compliance, and guide strategies for improvement through training and education. Conducting code compliance evaluation activities involves field studies that require careful design and significant resources. Historically, more emphasis has been placed on developing and adopting building energy codes, while efforts to evaluate compliance have been relatively limited and lacking consistent approaches. The passage of the 2009 American Recovery and Reinvestment Act (ARRA), which mandated that states create plans for achieving 90% compliance within eight years, stimulated the need for an energy code compliance evaluation. As a result, federal, state, and local governments, and utilities have invested in the development of methodologies and tools for code compliance evaluation studies. This paper reviews the code compliance evaluation studies conducted in the United States over the past three decades. It describes and compares the methodologies and metrics used to assess building energy code compliance, summarizes the general elements and steps involved in the evaluation process, and discusses common issues in these studies. Over time, code compliance evaluation methodologies have evolved from isolated development within individual states, regions, and utilities, to widely accepted protocols applicable across different states and local jurisdictions. There has been a transition in compliance metrics, shifting from historical compliance rates to energy-consumption-oriented approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Enhanced CO 2 Capture and Hydrogen Purification by Hydroxy Metal–Organic Framework/Polyimide Mixed Matrix Membranes

Membrane separation technology provides substantial savings in energy and cost for molecular separations in chemical industry, ideally complementing conventional thermally driven separation approaches. However, current membranes are subject to limitations, primarily lying in the Robeson permeability-selectivity upper bound limits. In this study, hydroxy metal-organic framework (MOF)/polyimide mixed-matrix membranes are found to enable high separation performance for applications including CO 2 capture and hydrogen purification while offering enhanced compatibility with state-of-the-art membrane-manufacturing processes. The mixed-matrix membranes exceed the present Robeson upper bounds with H 2 and CO 2 permeabilities of 907 and 650 Barrers, respectively and H 2 /CH 4 and CO 2 /CH 4 selectivities of 45 and 32, respectively. The unparalleled performance results from intimate interactions at the boundary of the hydroxy MOFs and carboxylic polymers through strong hydrogen bonds. Finally, the principle of design opens the door to highly permeable membranes with synergistic compatibility with established membrane manufacturing platforms for energy-efficient molecular separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Efficiency Low-Carbon Fuel Flexible Burner for Steel Industry

GTI Energy, with Bloom Engineering, Argonne National Laboratory and Oak Ridge National Laboratory, are developing the FlexGen-H burner. This high-efficiency burner can achieve 45•100% CO2e emissions reduction using green hydrogen with natural gas. It offers NOx, CO emissions ?50 ppm (3% O2), 15•51% fuel savings, ?50% PM2.5 reduction with turndown of ?5:1. The technology can work with renewable liquid fuels, ethanol or methanol. The technology aims to significantly reduce emissions, enhance resiliency, improve process efficiency. The paper will discuss preliminary results of development, with planned laboratory validation including safety, CFD, burner system design and market for the technology.

Sperry, McKay [ORNL] (ORCID:0009000658602049)↗

Continued Exploration of the Electrified Aircraft Propulsion Design Space

A previous electrified aircraft propulsion (EAP) design space exploration study was continued to investigate the impact of mission constraints, further explore the design space of different sized aircraft, and improve the modeling process. Three aircraft were investigated, 18- and 48-passenger turboprops, and a 78-passenger turbofan. Baseline aircraft models were inherited from the earlier study and were hybridized by applying EAP technologies. A parametric study varying motor power and battery specific energy was conducted. For the 78-passenger turbofan, design range was also introduced as a parametric parameter. Key metrics for the study included equivalent lifecycle CO2 emissions and direct operating cost plus interest. Both turboprop aircraft demonstrated significant potential savings in block fuel consumption and CO2 emissions, but at increased operating costs compared to their baseline models. As the 78-passenger turbofan had shown no improvements in any metrics under reasonable technology assumptions, design range was shortened in an attempt to obtain performance benefits. When designed for a shorter range, the 78-passenger EAP vehicle showed potential improvements in block fuel when compared to a baseline with a similarly shortened design range, but not in any other metrics. Operating cost reductions were not achieved for any aircraft, but several designs came close to breaking even with their baselines. Smaller, shorter range aircraft and turboprops demonstrated larger performance benefits and smaller operating cost penalties, but a simple trade of electric energy storage in batteries for fuel is generally insufficient to produce a viable aircraft concept.

Electrified Aircraft Propulsion↗

An Advanced Catalytic Solvent for Lower Cost Post-Combustion CO 2 Capture in a Coal-Fired Power Plant

In this report, CAER addresses DOE’s objectives for improvements on post-combustion CO 2 capture through a three-fold approach including 1) advanced solvent, 2) homogeneous catalyst and 3) membrane carbon enrichment system. CAER-B3 solvent was formulated to improve the overall thermodynamics with the addition of a proton receiver while maintaining faster kinetics with the addition of thermally robust primary amine. The EH&S study indicates that CAER-B3 solvent poses little human toxicological or ecological risk in its raw material form. Generation of significant quantities of nitrosamines was deemed unlikely when using B3 solvent for CO 2 capture from coal-derived flue gas. The catalytic solvent caused a 21% reduction in energy demand, achievable via decreasing the liquid flowrate. Cyclic capacity nearly doubled due to the slower flowrate, and therefore, reduced the sensible heat required to remove CO 2 in the stripper. The increased rich loadings achieved by either pre-concentrating membrane or dewatering membrane prior to stripper, in addition to improved cyclic capacity, will lower downstream compression costs, while reducing the energy consumption per unit of CO 2 produced. Moreover, the CAER-B3 solvent demonstrated a greater thermal stability, lessening the rate of amine loss, caused by solvent degradation and emissions, by 50-70%. The CAER developed catalysts with a second order rate constant of 7.5 x 10 4 – 10 5 M -1 s -1 , far beyond those reported to date. The catalyst was designed to be a mimic of the enzyme carbonic anhydrase and increase the rate of CO 2 hydration to produce bicarbonate. As such, a 10-25% improvement in absorption rate was observed over the MEA base case. Enhancements can be imparted to the full scale system to reduce packing height of the absorber column, resulting in significant capital cost savings. Furthermore, the family of CAER catalysts showed less than 10% decomposition over 100 hours at 100 °C, suggesting that these catalysts will be stable in the harsh oxidative and thermal process conditions of an industrial carbon capture unit. Flue gas contaminants, such as NO x and SO x , also did not impact catalytic activity. A method for synthetic production of 500 g/batch was designed, verified, and well-documented, with scaling capabilities up to 500 kg. Two types of membranes were designed and tested for the purpose of increasing the solvent carbon loading prior to entering the stripper column. 500 hour and 100 hour verification studies were completed for the pre-concentrating membrane and zeolite dewatering membrane, respectively. Results demonstrated that a membrane-based CO 2 enrichment step using a commercial CO 2 membrane, or a zeolite dewatering membrane, or both, should be implemented in the carbon capture process to increase the CO 2 partial pressure by 16%, resulting in a stripping energy reduction of 35% relative to DOE Case 12 MEA solvent. Experimental data showed a carbon loading enrichment of 18-40% in comparison to the configuration without the pre-concentrating gas membrane. During the timespan of this project, challenges were identified and addressed so that enhanced performance may be realized long-term. Mitigation implementations included re-configuration of the bench unit with a solvent recovery column and a knock-out drum, as well as an increase in stripper pressure set point. Both changes resulted in a considerable reduction in the rate of solvent loss. Additionally, the membrane synthesis procedure was modified and validated to address zeolite dissolution concerns along with a new separation module. The techno-economic analysis conducted by WorleyParsons indicated the CAER-adCCS hybrid approach may outperform NETL Case 12 with regards to net plant HHV efficiency and cost of electricity.

01 COAL, LIGNITE, AND PEAT↗

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

Building fault detection and diagnostics: Achieved savings, and methods to evaluate algorithm performance

Fault detection and diagnosis (FDD) represents one of the most active areas of research and commercial product development in the buildings industry. This paper addresses two questions concerning FDD implementation and advancement 1) What are today's users of FDD saving and spending on the technology? 2) What methods and datasets can be used to evaluate and benchmark FDD algorithm performance? Relevant to the first question, 26 organizations that use FDD across a total 550 buildings and 97 M sf achieved median savings of 8%. Twenty-seven FDD users reported that the median base cost for FDD software, annual recurring software cost, and annual labor cost were $8, $2.7 and $8 per monitoring point, with a median implementation size of approximately 1300 points. To address the second question, this paper describes a systematic methodology for evaluating the performance of FDD algorithms, curates an initial test dataset of air handling unit (AHU) system faults, and completes a trial to demonstrate the evaluation process on three sample FDD algorithms. The work provided a first step toward a standard evaluation of different FDD technologies. Finally, it showed the test methodology is indeed scalable and repeatable, provided an understanding of the types of insights that can be gained from algorithm performance testing, and highlighted the priorities for further expanding the test dataset.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selective Area Growth of GaAs on Si Patterned Using Nanoimprint Lithography

Heteroepitaxial selective area growth (SAG) of GaAs on patterned Si substrates is a potential low-cost approach to integrate III-V and Si materials for tandem or multijunction solar cells. The use of nanoscale openings in a dielectric material can minimize nucleation-related defects and allow thinner buffer layers to be used to accommodate lattice mismatch between Si and an epitaxial III-V layer. For photovoltaic applications, the cost of patterning and growth, as well as the impact on the performance of the Si bottom cell must be considered. We present preliminary results on the use of soft nanoimprint lithography (SNIL) to create patterned nucleation templates for the heteroepitaxial SAG of GaAs on Si. We demonstrate that SNIL patterning of passivating layers on the Si substrate improves measured minority carrier properties relative to unprotected Si. Cost modeling of the SNIL process shows that adding a patterning step only adds a minor contribution to the overall cost of a tandem III-V/Si solar cell, and can enable significant savings if it enables thinner buffer layers.

14 SOLAR ENERGY↗

Energy Management in Small Commercial Buildings: A Look at How HVAC Contractors Can Deliver Energy Efficiency to this Segment

While buildings smaller than 50,000 sq ft account for nearly half of the energy used in US commercial buildings, energy efficiency programs to-date have primarily focused on larger buildings. Interviews with stakeholders and a review of the literature indicate interest in energy efficiency from the small commercial building sector, provided solutions are simple and low-cost. An approach to deliver energy management to small commercial buildings via HVAC contractors and preliminary demonstration findings are presented. The energy management package (EMP) developed includes five technical elements: benchmarking and analysis of monthly energy use; analysis of interval electricity data (if available), a one-hour onsite walkthrough, communication with the building owner, and checking of results. This data-driven approach tracks performance and identifies low-cost opportunities, using guidelines and worksheets for each element to streamline the delivery process and minimize the formal training required. This energy management approach is unique from, but often complementary to conventional quality maintenance or retrofit-focused programs targeting the small commercial segment. Because HVAC contractors already serve these clients, the transaction cost to market and deliver energy management services can be reduced to the order of hundreds of dollars per year. This business model, outlined briefly in this report, enables the offering to benefit the contractor and client even at the modest expected energy savings in small buildings. Results from a small-scale pilot of this approach validated that the EMP could be delivered by contractors in 4-8 hours per building per year, and that energy savings of 3-5percent are feasible through this approach.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

DS-TIDE: Harnessing Dynamical Systems for Efficient Time-Independent Differential Equation Solving

Time-Independent Differential Equations (TIDEs) are central to modeling equilibrium behavior across a wide range of scientific and engineering domains, from electrostatics to porous media flow. Conventional numerical solvers offer reliable solutions but incur significant computational costs due to fine-grained discretization and iterative procedures. Machine learning-based approaches address this by replacing iterative solving processes with one-time inference; however, their sophisticated models require extensive training resources that often exceed those of traditional solvers. Consequently, designing a TIDE solver that achieves high accuracy, broad applicability, and exceptional computational efficiency remains a fundamental challenge. In this paper, we propose DS-TIDE, a novel hardware solver that is inspired by, and subsequently leverages, the intrinsic connection between Dynamical Systems (DS) and Differential Equations (DEs) to efficiently and accurately solve TIDEs. DS-TIDE employs a CMOS-compatible DS-based processor, whose physical states evolve under carefully designed DE-driven dynamics and naturally converge to equilibrium -- the solution of the target TIDE -- within ~1µs on a ~1-watt DS-TIDE processor. To enhance expressivity, DS-TIDE incorporates Heterogeneous Dynamics with Temporal Layering (HDTL), which solves TIDEs through a three-stage DS evolution -- conditioning, solving, and decoding -- each governed by specialized dynamics. The entire evolution process is analogous to an infinitely deep neural network temporally unrolled, offering the system the capability of representing complex equations. Furthermore, DS-TIDE is equipped with an on-device DS-DE Auto-Alignment mechanism that dynamically adapts intrinsic hardware dynamics within milliseconds, effectively aligning the system’s dynamics to diverse target DEs. Experimental results across TIDEs from a wide range of scientific and engineering domains demonstrate that DS-TIDE achieves ~10^3× speedup, ~10^5× energy savings, and competitive or superior accuracy compared to state-of-the-art numerical and ML-based solvers.

Liu, Chuan↗

Many-body perturbation theory with hybrid density functional theory starting points accelerated by adaptively compressed exchange

We report on the use of the adaptively compressed exchange (ACE) operator to accelerate many-body perturbation theory (MBPT) calculations, including G 0 W 0 and the Bethe–Salpeter equation (BSE), for hybrid density functional theory starting points. We show that by approximating the exact exchange operator with the low-rank ACE operator, substantial computational savings can be achieved with systematically controllable errors in the quasiparticle energies computed with full-frequency G 0 W 0 and the optical absorption spectra and vertical excitation energies computed by solving the BSE within density matrix perturbation theory. Our implementation makes use of the ACE-accelerated electronic Hamiltonian to carry out both G 0 W 0 and BSE without explicitly computing empty states. We show the robustness of the approach and present the computational gains obtained on both the central processing unit and graphics processing unit nodes. In conclusion, our work will facilitate the exploration and evaluation of fine-tuned hybrid starting points aimed at enhancing the accuracy of MBPT calculations without involving computationally demanding self-consistency in Hedin’s equations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Projections of Full-Fuel-Cycle Energy and Emissions Metrics

To accurately represent how conservation and efficiency policies affect energy demand, both direct and indirect impacts need to be included in the accounting. The indirect impacts are defined here as the resource savings that accrue over the fuel production chain, which when added to the energy consumed at the point of use, constitute the full-fuel- cycle (FFC) energy. This paper uses the accounting framework developed in (Coughlin 2012) to calculate FFC energy metrics as time series for the period 2010-2040. The approach is extended to define FFC metrics for the emissions of greenhouse gases (GHGs) and other air-borne pollutants. The primary focus is the types of energy used in buildings and industrial processes, mainly natural gas and electricity. The analysis includes a discussion of the fuel production chain for coal, which is used extensively for electric power generation, and for diesel and fuel oil, which are used in mining, oil and gas operations, and fuel distribution. Estimates of the energy intensity parameters make use of data and projections from the Energy Information Agency’s National Energy Modeling System, with calculations based on information from the Annual Energy Outlook 2012.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of low-cost silicon crystal growth techniques for terrestrial photovoltaic solar energy conversion

Because of the growing need for new sources of electrical energy, photovoltaic solar energy conversion is being developed. Photovoltaic devices are now being produced mainly from silicon wafers obtained from the slicing and polishing of cylindrically shaped single crystal ingots. Inherently high-cost processes now being used must either be eliminated or modified to provide low-cost crystalline silicon. Basic to this pursuit is the development of new or modified methods of crystal growth and, if necessary, crystal cutting. If silicon could be grown in a form requiring no cutting, a significant cost saving would potentially be realized. Therefore, several techniques for growth in the form of ribbons or sheets are being explored. In addition, novel techniques for low-cost ingot growth and cutting are under investigation.

Zoutendyk, J. A.↗

Development of 20 IEER Rooftop Units System Modeling and Building Energy Simulations

Based on detailed steady-state system and component modeling, we developed a rooftop unit system design, which is able to achieve IEER (Integrated Energy Efficiency Ratio) higher than 20. We modeled fin-&-tube and micro-channel heat exchangers using segment-to-segment approach, and use AHRI 10-coefficient compressor map to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having IEER of 16.6, we extensively investigated numerous technical options, i.e. varying compressor sizes, heat exchanger fin densities, fin-&-tube or micro-channel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor, variable-speed compressor, and condenser evaporative pre-cooling; and developed an innovative system configuration combining a tandem compression system with a variable-speed compression system. The combined system can achieve high IEER as well as process the outdoor ventilation air over an extensive range. We successfully evaluated the design concept for a 20-ton (70.4 kW) unit as well as a 10-ton (35.2 kW) unit. All the selected components are readily accessible on the market, and we validated the performance predictions against existing Rooftop Unit (RTU) products at the rating condition. This paper illustrates a potentially cost-effective high IEER RTU design. In addtion, we conducted extensive building energy simulations using EnergyPlus to predict seasonal energy saving potentials and peak power reductions using the High IEER RTU in sixteen US cities, in comparison to a RTU with a minimum efficiency.

Modeling↗