Search NASA⌕ Search

SEARCH · Search NASA

Results for “evaluation protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Terrestrial Biological Carbon Sequestration: Science for Enhancement and Implementation

Fossil-fuel combustion and land-use change have elevated atmospheric CO2 concentrations from 280 ppmv at the beginning of the industrial era to more than 381 ppmv in 2006. Carbon dioxide emissions from fossil fuels and cement rose 71% during 1970–2000 to a rate of 7.0 PgC/y (1). Canadell et al. (2) estimated that CO2 emissions rose at a rate at 1.3% per year during 1990–1999, but since 2000 it has been growing at 3.3% per year. Emissions reached 8.4 PgC/y in 2006. It is likely that the current 2-ppm annual increase will accelerate as the global economy expands, increasing the risk of climate system impacts. There is good agreement that photosynthetic CO2 capture from the atmosphere and storage of the C in above- and belowground biomass and in soil organic and inorganic forms could be exploited for safe and affordable greenhouse gas (GHG) mitigation (3). Nevertheless, C sequestration in the terrestrial biosphere has been a source of contention before and since the drafting of the Kyoto Protocol in 1997. Concerns have been raised that C sequestration in the biosphere is not permanent, that it is difficult to measure and monitor, that there would be “carbon leakage” outside of the mitigation activity, and that any attention paid to environmental sequestration would be a distraction from the central issue of reducing GHG emissions from energy production and use. A decade after drafting the Kyoto Protocol, it is clear that international accord and success in reducing emissions from the energy system are not coming easily and concerns about climate change are growing. It is time to re-evaluate all available options that might not be permanent yet have the potential to buy time, bridging to a future when new energy system technologies and a transformed energy infrastructure can fully address the climate challenge. Terrestrial sequestration is one option large enough to make a contribution in the coming decades using proven land-management methods and with the possibility that new technologies could significantly enhance the opportunity. Here we review progress on key scientific, economic, and social issues; postulate the extent to which new technologies might significantly enhance terrestrial sequestration potential; and address remaining research needs.

Post, W M↗

SU-F-J-222: Using PET Imaging to Evaluate Proliferation and Blood Flow in Irradiated and Non-Irradiated Bone Marrow 1 Year After Chemoradiation Therapy

Purpose: To compare proliferation and blood flow in pelvic and thoracic bone marrow 1 year after pelvic chemoradiation. Methods: Sixteen pelvic cancer patients were enrolled in an IRB-approved protocol to acquire FLT PET images during radiation therapy simulation (baseline) and 1 year after chemoradiation therapy. Three subjects also had optional O-15 water PET images acquired 1 year after chemoradiation therapy. Baseline FLT PET images were used to create IMRT plans to spare pelvic bone marrow identified as regions with FLT SUV ≥ 2 without compromising PTV coverage or OAR sparing. Marrow VOIs were defined using a 50% maximum pixel value threshold on baseline FLT PET images (VIEW, PMOD version 3.5) in the sacrum and thoracic spine representing irradiated and non-irradiated regions, respectively. FLT PET and O-15 water PET images acquired 1 year after therapy were co-registered to baseline images (FUSION PMOD) and the same VOIs were used to measure proliferation (FLT SUV) and blood flow (O-15 water uptake). Separate image-based input functions were used for blood flow quantitation in each VOI. Results: Mean 1 year FLT SUV in sacral and thoracic VOIs for were 1.1 ± 0.4 and 6.5 ± 1.7, respectively for N = 16 subjects and were 1.2 ± 0.2 and 5.6 ± 1.6, respectively for N = 3 subjects who also underwent O-15 water imaging. Blood flow measures in equivalent sacral and thoracic marrow regions (N = 3) were 21.3 ± 8.7 and 18.3 ± 4.9 mL/min/100mL respectively. Conclusion: Decreased bone marrow proliferation measured by FLT SUV does not appear to correspond to decreased blood flow as measured by O-15 water PET imaging. Based on this small sample at a single time point, reduced blood supply does not explain reductions in bone marrow proliferative activity 1 year after chemoradiation therapy.

60 APPLIED LIFE SCIENCES↗

Quantifying non-Gaussianity for quantum information

We address the quantification of non-Gaussianity (nG) of states and operations in continuous-variable systems and its use in quantum information. We start by illustrating in detail the properties and the relationships of two recently proposed measures of nG based on the Hilbert-Schmidt distance and the quantum relative entropy (QRE) between the state under examination and a reference Gaussian state. We then evaluate the non-Gaussianities of several families of non-Gaussian quantum states and show that the two measures have the same basic properties and also share the same qualitative behavior in most of the examples taken into account. However, we also show that they introduce a different relation of order; that is, they are not strictly monotone to each other. We exploit the nG measures for states in order to introduce a measure of nG for quantum operations, to assess Gaussification and de-Gaussification protocols, and to investigate in detail the role played by nG in entanglement-distillation protocols. Besides, we exploit the QRE-based nG measure to provide different insight on the extremality of Gaussian states for some entropic quantities such as conditional entropy, mutual information, and the Holevo bound. We also deal with parameter estimation and present a theorem connecting the QRE nG to the quantum Fisher information. Finally, since evaluation of the QRE nG measure requires the knowledge of the full density matrix, we derive some experimentally friendly lower bounds to nG for some classes of states and by considering the possibility of performing on the states only certain efficient or inefficient measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Water Adsorption and Dissociation on Polycrystalline Copper Oxides: Effects of Environmental Contamination and Experimental Protocol

We use ambient-pressure X-ray photoelectron spectroscopy (APXPS) to study chemical changes, including hydroxylation and water adsorption, at copper oxide surfaces from ultrahigh vacuum to ambient relative humidities of ~5%. Polycrystalline CuO and Cu 2 O surfaces were prepared by selective oxidation of metallic copper foils. For both oxides, hydroxylation occurs readily, even at high-vacuum conditions. Hydroxylation on both oxides plateaus near ~0.01% relative humidity (RH) at a coverage of ~1 monolayer. In contrast to previous studies, neither oxide shows significant accumulation of molecular water; rather, both surfaces show a high affinity for adventitious carbon contaminants. Results of isobaric and isothermic experiments are compared, and the strengths and potential drawbacks of each method are discussed. We also provide critical evaluations of the effects of the hot filament of the ion pressure gauge on the reactivity of gas-phase species, the peak fitting procedure on the quantitative analysis of spectra, and rigorous accounting of carbon contamination on data analysis and interpretation. Lastly, this work underscores the importance of considering experimental design and data analysis protocols during APXPS experiments with water vapor in order to minimize misinterpretations arising from these factors.

36 MATERIALS SCIENCE↗

Influence of cleaning process on the laser-induced damage threshold of substrates

The cleaning process of optical substrates plays an important role during the manufacture of high-power laser coatings. Two kinds of substrates, fused silica and BK7 glass, and two cleaning processes, called process 1 and process 2 having different surfactant solutions and different ultrasonic cleaning parameters, are adopted to compare the influence of the ultrasonic cleaning technique on the substrates. The evaluation standards of the cleaning results include contaminant-removal efficiency, weak absorption, and laser-induced damage threshold of the substrates. For both fused silica and BK7, process 2 is more efficient than process 1. Because acid and alkaline solutions can increase the roughness of BK7, process 2 is unsuitable for BK7 glass cleaning. The parameters of the cleaning protocol should be changed depending on the material of the optical components and the type of contamination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-J-38: Dose Rates and Preliminary Evaluation of Contouring Similarity Metrics Using 4D Cone Beam CT

Purpose: 4D imaging modalities require detailed characterization for clinical optimization. The On-Board Imager mounted on the linear accelerator was used to investigate dose rates in a tissue mimicking phantom using 4D-CBCT and assess variability of contouring similarity metrics between 4D-CT and 4D-CBCT retrospective reconstructions. Methods: A 125 kVp thoracic protocol was used. A phantom placed on a motion platform simulated a patient’s breathing cycle. An ion chamber was affixed inside the phantom’s tissue mimicking cavities (i.e. bone, lung, and soft tissue). A sinusoidal motion waveform was executed with a five second period and superior-inferior motion. Dose rates were measured at six ion chamber positions. A preliminary workflow for contouring similarity between 4D-CT and 4D-CBCT was established using a single lung SBRT patient’s historical data. Average intensity projection (Ave-IP) and maximum intensity projection (MIP) reconstructions generated offline were compared between the 4D modalities. Similarity metrics included Dice similarity coefficient (DSC), Hausdorff distance, and center of mass (COM) deviation. Two isolated lesions were evaluated in the patient’s scans: one located in the right lower lobe (ITVRLL) and one located in the left lower lobe (ITVLLL). Results: Dose rates ranged from 2.30 (lung) to 5.18 (bone) E-3 cGy/mAs. For fixed acquisition parameters, cumulative dose is inversely proportional to gantry speed. For ITVRLL, DSC were 0.70 and 0.68, Hausdorff distances were 6.11 and 5.69 mm, and COM deviations were 1.24 and 4.77 mm, for Ave-IP and MIP respectively. For ITVLLL, DSC were 0.64 and 0.75, Hausdorff distances were 10.74 and 8.00 mm, and COM deviations were 7.55 and 4.3 mm, for Ave-IP and MIP respectively. Conclusion: While the dosimetric output of 4D-CBCT is low, characterization is necessary to assure clinical optimization. A basic workflow for comparison of simulation and treatment 4D image-based contours was established. This work was partially supported by a Research Scholar Grant (RSG-15-137-01-CCE) from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

Biological toxicity and environmental hazards associated with PLGA nanoparticles

There have been tremendous advances in nanotechnology. More recently, the use of nanoparticles has expanded to applications including materials, packaging, energy, and medical uses such as drug delivery, diagnostics, and therapeutics. The American Society for Testing and Materials (ASTM) and the International Organization for Standardization (ISO) define nanoparticles as particles with at least one dimension measuring between 1 and 100 nm (2), but this view is generally too limited, and recommendations have been made to consider all materials with a dimension measuring under 1,000 nm as nanoparticles. The biomedical uses of nanoparticles are particularly promising because of their ability to reach and target various sites and organs. However, some nanoparticles can be composed of toxic materials or are limited by issues of biodistribution and bioaccumulation, which have hampered their use in biomedicine. The copolymer poly lactic-co-glycolic acid (PLGA) has gained use in biomedical applications as a delivery system because it is considered biocompatible and can be formulated with controlled degradation in physiological environments. PLGA has a history in biomedicine that dates to the 1970s when biodegradable sutures were developed using PLGA. In addition, the United States (US) Food and Drug Administration (FDA) and the European Medicine Agency (EMA) have approved various PLGA particle formulations as therapeutic delivery vehicles. Interest in biocompatible materials to deliver a range of therapeutic drugs, proteins, nucleic acids, and other molecules has risen recently. In addition to drug delivery, sustained drug release can be achieved by tuning the physical properties of PLGA, such as the molecular weight, ratio of lactic to glycolic acid, drug concentration, stabilizing molecules, and particle size. Given the rise of nanoparticles, human and environmental exposure to them is inevitable as more applications use free, unbound, and highly mobile particles. Although PLGA is generally considered safe, a detailed understanding of how PLGA and the other components used to help formulate this copolymer into a nanoparticle delivery vehicle is useful for assessing potential harmful effects. Despite recent advances in PLGA nanoparticle formulations, residual stabilizing molecules, inconsistent preparations, and batch-to-batch variations can lead to toxicity. Poor preparations of PLGA can lead to common mechanisms of toxicity observed with nanoparticles, such as inflammation and oxidative stress. Consistency in PLGA formulations and accurate methods to evaluate nanoparticle toxicity are needed to ensure safety. In order to better assess PLGA nanoparticles as non-toxic delivery systems, it is critical to understand their physical and chemical properties and the formulation protocols that may introduce toxic components into particles.

Biology, nanoparticle, toxicity↗

Scalable method for micro-CT analysis enables large scale quantitative characterization of brain lesions and implants

Anatomic evaluation is an important aspect of many studies in neuroscience; however, it often lacks information about the three-dimensional structure of the brain. Micro-CT imaging provides an excellent, nondestructive, method for the evaluation of brain structure, but current applications to neurophysiological or lesion studies require removal of the skull as well as hazardous chemicals, dehydration, or embedding, limiting their scalability and utility. Here we present a protocol using eosin in combination with bone decalcification to enhance contrast in the tissue and then employ monochromatic and propagation phase-contrast micro-CT imaging to enable the imaging of brain structure with the preservation of the surrounding skull. Instead of relying on descriptive, time-consuming, or subjective methods, we develop simple quantitative analyses to map the locations of recording electrodes and to characterize the presence and extent of hippocampal brain lesions.

3-D reconstruction↗

Trust Model Measurements for the Energy Grid of Things

Information security is essential for the reliable operation of an Energy Grid of Things (EGoT). In addition to basic information security protocols as defined by published standards, there is a need for a monitoring function that measures the trustworthiness of the various actors participating in an EGoT. We describe in this paper the implementation and evaluation of a Distributed Trust Model that was developed specifically for monitoring communication within an EGoT. We then show how the model parameters are set using statistical measures for hypothesis testing.

Energy Grid of Things, EGoT, Smart Grid Security, ↗

SU-E-T-477: An Efficient Dose Correction Algorithm Accounting for Tissue Heterogeneities in LDR Brachytherapy

Purpose: Seed brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose surrounding the brachytherapy seeds is based on American Association of Physicist in Medicine Task Group No. 43 (TG-43 formalism) which generates the dose in homogeneous water medium. Recently, AAPM Task Group No. 186 emphasized the importance of accounting for tissue heterogeneities. This can be done using Monte Carlo (MC) methods, but it requires knowing the source structure and tissue atomic composition accurately. In this work we describe an efficient analytical dose inhomogeneity correction algorithm implemented using MIM Symphony treatment planning platform to calculate dose distributions in heterogeneous media. Methods: An Inhomogeneity Correction Factor (ICF) is introduced as the ratio of absorbed dose in tissue to that in water medium. ICF is a function of tissue properties and independent of source structure. The ICF is extracted using CT images and the absorbed dose in tissue can then be calculated by multiplying the dose as calculated by the TG-43 formalism times ICF. To evaluate the methodology, we compared our results with Monte Carlo simulations as well as experiments in phantoms with known density and atomic compositions. Results: The dose distributions obtained through applying ICF to TG-43 protocol agreed very well with those of Monte Carlo simulations as well as experiments in all phantoms. In all cases, the mean relative error was reduced by at least 50% when ICF correction factor was applied to the TG-43 protocol. Conclusion: We have developed a new analytical dose calculation method which enables personalized dose calculations in heterogeneous media. The advantages over stochastic methods are computational efficiency and the ease of integration into clinical setting as detailed source structure and tissue segmentation are not needed. University of Toronto, Natural Sciences and Engineering Research Council of Canada.

60 APPLIED LIFE SCIENCES↗

The SRT reconstruction algorithm for semiquantification in PET imaging

Purpose: The spline reconstruction technique (SRT) is a new, fast algorithm based on a novel numerical implementation of an analytic representation of the inverse Radon transform. The mathematical details of this algorithm and comparisons with filtered backprojection were presented earlier in the literature. In this study, the authors present a comparison between SRT and the ordered-subsets expectation–maximization (OSEM) algorithm for determining contrast and semiquantitative indices of {sup 18}F-FDG uptake. Methods: The authors implemented SRT in the software for tomographic image reconstruction (STIR) open-source platform and evaluated this technique using simulated and real sinograms obtained from the GE Discovery ST positron emission tomography/computer tomography scanner. All simulations and reconstructions were performed in STIR. For OSEM, the authors used the clinical protocol of their scanner, namely, 21 subsets and two iterations. The authors also examined images at one, four, six, and ten iterations. For the simulation studies, the authors analyzed an image-quality phantom with cold and hot lesions. Two different versions of the phantom were employed at two different hot-sphere lesion-to-background ratios (LBRs), namely, 2:1 and 4:1. For each noiseless sinogram, 20 Poisson realizations were created at five different noise levels. In addition to making visual comparisons of the reconstructed images, the authors determined contrast and bias as a function of the background image roughness (IR). For the real-data studies, sinograms of an image-quality phantom simulating the human torso were employed. The authors determined contrast and LBR as a function of the background IR. Finally, the authors present plots of contrast as a function of IR after smoothing each reconstructed image with Gaussian filters of six different sizes. Statistical significance was determined by employing the Wilcoxon rank-sum test. Results: In both simulated and real studies, SRT exhibits higher contrast and lower bias than OSEM at the cold lesions. This improvement is achieved at the expense of increasing the noise in the reconstructed images. For the hot lesions, SRT exhibits a small improvement in contrast and LBR over OSEM with 21 subsets and two iterations; however, this improvement is not statistically significant. As the number of iterations increases, the performance of OSEM improves over SRT but again without statistical significance. The curves of contrast and LBR as a function of IR after Gaussian blurring indicate that the advantage of SRT in the cold regions is maintained even after decreasing the noise level by Gaussian blurring. Conclusions: SRT, at the expense of slightly increased noise in the reconstructed images, reconstructs images of higher contrast and lower bias than the clinical protocol of OSEM. This improvement is particularly evident for images involving cold regions. Thus, it appears that SRT should be particularly useful for the quantification of low-count and cold regions.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗

Missouri Soybean Association Biodiesel Demonstration Project: Final Report

The Missouri Soybean Association (MSA) and the National Biodiesel Board (NBB) partnered together to implement the MSA Biodiesel Demonstration project under a United States Department of Energy (DOE) grant. The goal of this project was to provide decision makers and fleet managers with information that could lead to the increased use of domestically produced renewable fuels and could reduce the harmful impacts of school bus diesel exhaust on children. This project was initiated in September 2004 and completed in April 2011. The project carried out a broad range of activities organized under four areas: 1. Petroleum and related industry education program for fuel suppliers; 2. Fleet evaluation program using B20 with a Missouri school district; 3. Outreach and awareness campaign for school district fleet managers; and 4. Support of ongoing B20 Fleet Evaluation Team (FET) data collection efforts with existing school districts. Technical support to the biodiesel industry was also provided through NBB’s Troubleshooting Hotline. The hotline program was established in 2008 to troubleshoot fuel quality issues and help facilitate smooth implementation of the RFS and is described in greater detail under Milestone A.1 - Promote Instruction and Guidance on Best Practices. As a result of this project’s efforts, MSA and NBB were able to successfully reach out to and support a broad spectrum of biodiesel users in Missouri and New England. The MSA Biodiesel Demonstration was funded through a FY2004 Renewable Energy Resources Congressional earmark. The initial focus of this project was to test and evaluate biodiesel blends coupled with diesel oxidation catalysts as an emissions reduction technology for school bus fleets in the United States. The project was designed to verify emissions reductions using Environmental Protection Agency (EPA) protocols, then document – with school bus fleet experience – the viability of utilizing B20 blends. The fleet experience was expected to support ongoing industry efforts to collect existing data and to increase awareness and knowledge among school district fleet managers. However, three years into the project, the original intent of the engine verification was no longer deemed by equipment manufacturers to be of sufficient economic interest to enter into a partnership. In response, MSA requested a project extension and re-scope to eliminate the aftermarket equipment verification and replace it with a petroleum education program. The revised project maintained four task areas with the following modifications. The first component was directed at increasing national compliance with newly initiated state level fuel blend mandates through a distributor education program. Component two was modified to eliminate the verification element and, instead, document operational data from biodiesel use in a district school bus fleet. Components three and four were unchanged and maintained their purpose of expanding upon the existing knowledge base of biodiesel use in school bus fleets.

09 BIOMASS FUELS↗

High Resolution Scanning Configurations for the Canberra Tomographic Gamma Scanner - 17323

The Canberra Tomographic Gamma Scanner (TGS) is a Non-Destructive Assay (NDA) system that combines high resolution gamma ray spectroscopy (HRGS) with low-spatial-resolution imaging for the measurement of heterogeneous drummed waste with matrix densities in the range of 0 to 1 g/cc. The TGS methodology uses a two-pass scanning protocol; a 10-15 μCi {sup 152}Eu transmission source is used to interrogate density and composition of the matrix in the first pass, and passive gamma ray spectroscopy is used to collect emission spectra in the second, while the drum is rotated and translated to vary the view path. In standard implementations, the transmission and emission data are used to reconstruct three dimensional images of the matrix and activity distribution inside the drum on a 10x10x16 grid of discrete volume elements or 'voxels'. These images allow attenuation corrections to be calculated and applied on a view by view, and voxel by voxel basis, reducing the over- and under-correction biases obtained by assay techniques which assume homogeneous distributions of material. The most recent TGS system deployed by Canberra featured, among other new developments, the ability to perform higher resolution image re-construction, which may prove beneficial for the assay of more highly mixed matrices or oddly shaped assay items within a container. These additional scanning protocols reconstruct the image data into 14x14 and 20x20 voxel grids, using a smaller collimator aperture size. The hardware and software implementations of these higher resolution scans are discussed, and the calibration and initial evaluations of performance are presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-626: Accuracy of Dose Calculation Algorithms in MultiPlan Treatment Planning System in Presence of Heterogeneities

Purpose: Advanced stereotactic radiotherapy (SRT) treatments require accurate dose calculation for treatment planning especially for treatment sites involving heterogeneous patient anatomy. The purpose of this study was to evaluate the accuracy of dose calculation algorithms, Raytracing and Monte Carlo (MC), implemented in the MultiPlan treatment planning system (TPS) in presence of heterogeneities. Methods: First, the LINAC of a CyberKnife radiotherapy facility was modeled with the PENELOPE MC code. A protocol for the measurement of dose distributions with EBT3 films was established and validated thanks to comparison between experimental dose distributions and calculated dose distributions obtained with MultiPlan Raytracing and MC algorithms as well as with the PENELOPE MC model for treatments planned with the homogenous Easycube phantom. Finally, bones and lungs inserts were used to set up a heterogeneous Easycube phantom. Treatment plans with the 10, 7.5 or the 5 mm field sizes were generated in Multiplan TPS with different tumor localizations (in the lung and at the lung/bone/soft tissue interface). Experimental dose distributions were compared to the PENELOPE MC and Multiplan calculations using the gamma index method. Results: Regarding the experiment in the homogenous phantom, 100% of the points passed for the 3%/3mm tolerance criteria. These criteria include the global error of the method (CT-scan resolution, EBT3 dosimetry, LINAC positionning …), and were used afterwards to estimate the accuracy of the MultiPlan algorithms in heterogeneous media. Comparison of the dose distributions obtained in the heterogeneous phantom is in progress. Conclusion: This work has led to the development of numerical and experimental dosimetric tools for small beam dosimetry. Raytracing and MC algorithms implemented in MultiPlan TPS were evaluated in heterogeneous media.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-03: Comparison of Standard Dosimetry Protocol in Japan and AAPM TG-51 Addendum in Order to Establish Optimal Dosimetry for FFF Beam

Purpose: Japan Standard Dosimetry of Absorbed dose to water in external beam radiotherapy (JSDP12) is widely used to measure radiation dose in radiotherapy. However, JSDP12 does not take flattening-filter-free (FFF) beam into consideration. In addition, JSDP12 applied TPR20,10 for dose quality index for photon beam. The purpose of this study is to compare JSDP12 with AAPM TG-51 addendum in order to establish optimal dosimetry procedure for FFF beam. Method: We evaluated the ion-recombination factor (ks) and the correction factor of radial beam profile (Prp) in FFF beam dosimetry. The ks was introduced by 2 voltages method and verified by Jaffe’s plot. The Prp was given by both film measurement and calculation of treatment planning system, and compared them. Next, we compared the dose quality indexes (kQ) between TPR20,10 method and PDD(10)x method. Finally we considered optimal dosimetry protocol for FFF photon beam using JSDP12 with referring TG-51 addendum protocols. The FFF photon beams of 6 MV (6X-FFF) and 10 MV (10X-FFF) from TrueBeam were investigated in this study. Results: The ks for 6X-FFF and 10X-FFF beams were 1.005 and 1.010, respectively. The Prp of 0.6 cc ionization chamber for 6X-FFF and 10X-FFF beams (Film, TPS) were (1.004, 1.008) and (1.005, 1.008), respectively. The kQ for 6X-FFF and 10X-FFF beams (JSDP12, TG-51 addendum) were (0.9950, 0.9947) and (0.9851, 0.9845), respectively. The most effective factor for uncertainty in FFF photon beam measurement was Prp for JSDP12 formalism. Total dosimetric differences between JSDP12 and TG-51 addendum for 6X-FFF and 10X-FFF were -0.47% and -0.73%, respectively. Conclusion: The total dosimetric difference between JSDP12 and TG-51 addendum was within 1%. The introduction of kQ given by JSDP is feasible for FFF photon beam dosimetry. However, we think Prp should be considered for optimal dosimetry procedure even if JSDP12 is used for FFF photon beam dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Demonstrating Distribution System Resiliency through Grid-Edge Microgrids, on a Multi-Site Networked Hardware-in-Loop Platform

With the increasing penetration of Distributed Energy Resources (DERs) at the grid-edge, power systems include more energy storage, remote switches, relays, voltage regulators, and other intelligent electronic devices (IED). Effective control of these grid-edge devices by using Advanced Distribution Management Systems (ADMS) can yield substantial improvements to the resiliency and power quality of distribution systems. In this paper, improvements to the resiliency of a distribution system are demonstrated using a multi-site evaluation environment consisting of a real-time Hardware-in-Loop (HIL) setup in which DERs and other IEDs are modeled; and an ADMS which monitors and is able to control the distribution system assets. The HIL model and the ADMS are located 2400 km away, with communication between the sites enabled by a data manager using Distributed Network Protocol 3 (DNP3), demonstrating the system's capabilities even over long distances. After a simulated transmission system failure in the HIL demonstration setup, DERs and other devices are operated to restore critical loads and node voltage profile (to within the 'nominal +/-5%' band) in the distribution system.

ADMS↗

Evaluation of Effectiveness of Embolization in Pelvic Congestion Syndrome with the New Vascular Occlusion Device (ArtVentive EOS™): Preliminary Results

PurposeThis study aimed to collect confirmatory data in support of the safety and efficiency of the ArtVentive EOS™ for the treatment of the pelvic congestion syndrome (PCS). This study was based on the OCCLUDE 1 Study Protocol approved by the Local Ethics Committee.Materials and MethodsA prospective study carried out in June and July 2014 included 12 women aged 21–48 years (mean 31 years) scheduled for PCS embolization using the ArtVentive EOS™. The inclusion criteria were clinical symptoms of PCS documented by transvaginal Doppler ultrasound and pelvic MRI. The pelvic pain was assessed by VAS score from 0 to 10 (0 represents lack of pain and 10 unbearable pain). A decrease in pelvic pain intensity based on the VAS was considered a clinical success.ResultsSuccessful embolization procedures with ArtVentive EOS™ were performed in 11 out of 12 patients. Nine patients underwent unilateral embolization of the left ovarian vein, and two had bilateral embolization of the ovarian veins. Complete ovarian vein occlusion confirmed by post deployment venography was achieved in all 11 patients. Procedures lasted from 19 to 45 min (average 28 min). Pain intensity decrease was observed in all 11 patients—a decrease of 5.6 points—from 7.3 pre-procedure to 1.6 post-embolization (standard deviation: 0.67). In one case, the left ovarian vein was injured by guide wire manipulation with contrast extravasation—not clinically significant.ConclusionsThe use of ArtVentive EOS™ for occlusion of the ovarian veins in PCS patients is safe and effective.

62 RADIOLOGY AND NUCLEAR MEDICINE↗