Search NASA⌕ Search

SEARCH · Search NASA

Results for “false data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

AmeriFlux FLUXNET-1F US-Ton Tonzi Ranch

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Ton Tonzi Ranch. This is the FLUXNET version of the carbon flux data for the site US-Ton Tonzi Ranch produced by applying the standard ONEFlux (1F) software. Site Description - The Tonzi Ranch is located on the lower foothills of the Sierra Nevada Mountains. The site is classified as an oak savanna woodland (Davis et al, 2016) and is situated on privately owned land. This site is representative of the oak savanna ecosystem that rings the Great Central Valley of California and inhabits the lower reaches of the Sierra Nevada foothills. This ecosystem is a natural laboratory for studying how ecosystem scale carbon and water fluxes respond to environmental change. The temperatures range between 0 and 40 C, the autumn, winter and spring are wet and cool, while the summer growing season is hot, dry and rainless. The overstory is dominated by blue oak trees (40% of total vegetation) with intermittent grey pine trees (3 trees/ha). Understory species include a variety of grasses and herbs, including purple false brome, smooth cat's ear, and rose clover. These two distinctive layers operate in and out of phase from one another. Growing season of the understory is confined to the wet season only, typically from October to early May. In contrast, the deciduous blue oak trees are dormant and leafless during the rainy winter months. The trees tend to leaf out in March and reach maximum LAI in April. During the rainless summers, the grasses in the understory die and the leaves experience soil moisture deficit stress References Davis, F., et al. (2016). "Oak woodlands." Ecosystems of California: 509–529.

Ma, Siyan↗

Validation of a treatment plan-based calibration method for 2D detectors used for treatment delivery quality assurance

Purpose: Dosimetry using film, CR, electronic portal imaging, or other 2D detectors requires calibration of the raw image data to obtain dose. Typically, a series of known doses are given to the detector, the raw signal for each dose is obtained, and a calibration curve is created. This calibration curve is then applied to the measured raw signals to convert them to dose. With the advent of IMRT, film dosimetry for quality assurance has become a routine and labor intensive part of the physicist's day. The process of calibrating the film or other 2D detector takes time and additional film or images for performing the calibration, and comes with its own source of errors. This article studies a new methodology for the relative dose calibration of 2D imaging detectors especially useful for IMRT QA, which relies on the treatment plan dose image to provide the dose information which is paired with the raw QA image data after registration of the two images (plan-based calibration). Methods: Validation of the accuracy and robustness of the method is performed on ten IMRT cases performed using EDR2 film with conventional and plan-based calibration. Also, for each of the ten cases, a 5 mm registration error was introduced and the Gamma analysis was reevaluated. In addition, synthetic image tests were performed to test the limits of the method. The Gamma analysis is used as a measure of dosimetric agreement between plan and film for the clinical cases and a dose difference metric for the synthetic cases. Results: The QA image calibrated by the plan-based method was found to more accurately match the treatment plan doses than the conventionally calibrated films and also to reveal dose errors more effectively when a registration error was introduced. When synthetic acquired images were systematically studied, localized and randomly placed dose errors were correctly identified without excessive falsely passing or falsely failing pixels, unless the errors were concentrated in a majority of pixels in a contiguous narrow dose band. Irregularities seen in the calibration curve expose these errors. Conclusions: The plan-based calibration method was found to be an accurate, efficient procedure, capable of detecting IMRT QA relative dosimetry errors as well as, or better than conventional calibration methods.

07 ISOTOPE AND RADIATION SOURCES↗

Human virus and microbial indicator occurrence in public-supply groundwater systems: meta-analysis of 12 international studies

Groundwater quality is often evaluated using microbial indicators. This study examines data from 12 international groundwater studies (conducted 1992–2013) of 718 public drinking-water systems located in a range of hydrogeological settings. Focus was on testing the value of indicator organisms for identifying virus-contaminated wells. One or more indicators and viruses were present in 37 and 15% of 2,273 samples and 44 and 27% of 746 wells, respectively. Escherichia coli ( E. coli ) and somatic coliphage are 7– 9 times more likely to be associated with culturable viruspositive samples when the indicator is present versus when it is absent, while F-specific and somatic coliphages are 8–9 times more likely to be associated with culturable viruspositive wells. However, single indicators are only marginally associated with viruses detected by molecular methods, and all microbial indicators have low sensitivity and positive predictive values for virus occurrence, whether by culturable or molecular assays, i.e., indicators are often absent when viruses are present and the indicators have a high false-positive rate. Wells were divided into three susceptibility subsets based on presence of (1) total coliform bacteria or (2) multiple indicators, or (3) location of wells in karst, fractured bedrock, or gravel/cobble settings. Better associations of some indicators with viruses were observed for (1) and (3). Findings indicate the best indicators are E. coli or somatic coliphage, although both indicators may underestimate virus occurrence. Repeat sampling for indicators improves evaluation of the potential for viral contamination in a well.

58 GEOSCIENCES↗

Statistical Requirements For Pass-Fail Testing Of Contraband Detection Systems

Contraband detection systems for homeland security applications are typically tested for probability of detection (PD) and probability of false alarm (PFA) using pass-fail testing protocols. Test protocols usually require specified values for PD and PFA to be demonstrated at a specified level of statistical confidence CL. Based on a recent more theoretical treatment of this subject [1], this summary reviews the definition of CL and provides formulas and spreadsheet functions for constructing tables of general test requirements and for determining the minimum number of tests required. The formulas and tables in this article may be generally applied to many other applications of pass-fail testing, in addition to testing of contraband detection systems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Elastic Changepoint Detection for Globally-indexed Functional Time Series Data with Climate Applications

Changepoint detection is a vital tool in the application of climate data analysis. Numerous types of climate observation data are most properly represented by functional time series, implying a need for accurate changepoint detection methods applicable to functional time series data. Such data taken at a global scale often contain both spatial heterogeneity and dependence as well as phase (time) misalignment. In this report, we present methods which can detect spatially-dependent changepoints while allowing different estimates of change time and change strength depending on location. Additionally, we provide extensions to this spatially-predicted model which controls for phase variability among observations. Our methods provide the ability to detect a single change, or control for epidemic changes (where a “return-to-normal” change is more likely to be detected than the initial change). We showcase results analyzing the June 1991 eruption of Mt. Pinatubo, where our methods demonstrate the ability to accurately detect both single and epidemic changepoints even in the presence of strong seasonal variability. We find that our spatially-predicted model improves the detection of relevant changepoints versus methods which do not take spatial information into account, and we find that controlling for phase variability helps to control the false discovery rate during the detection process.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Automatic Atlas-Based Lymph Node Segmentation for Head-and-Neck Cancer

Purpose: To evaluate if automatic atlas-based lymph node segmentation (LNS) improves efficiency and decreases inter-observer variability while maintaining accuracy. Methods and Materials: Five physicians with head-and-neck IMRT experience used computed tomography (CT) data from 5 patients to create bilateral neck clinical target volumes covering specified nodal levels. A second contour set was automatically generated using a commercially available atlas. Physicians modified the automatic contours to make them acceptable for treatment planning. To assess contour variability, the Simultaneous Truth and Performance Level Estimation (STAPLE) algorithm was used to take collections of contours and calculate a probabilistic estimate of the 'true' segmentation. Differences between the manual, automatic, and automatic-modified (AM) contours were analyzed using multiple metrics. Results: Compared with the 'true' segmentation created from manual contours, the automatic contours had a high degree of accuracy, with sensitivity, Dice similarity coefficient, and mean/max surface disagreement values comparable to the average manual contour (86%, 76%, 3.3/17.4 mm automatic vs. 73%, 79%, 2.8/17 mm manual). The AM group was more consistent than the manual group for multiple metrics, most notably reducing the range of contour volume (106-430 mL manual vs. 176-347 mL AM) and percent false positivity (1-37% manual vs. 1-7% AM). Average contouring time savings with the automatic segmentation was 11.5 min per patient, a 35% reduction. Conclusions: Using the STAPLE algorithm to generate 'true' contours from multiple physician contours, we demonstrated that, in comparison with manual segmentation, atlas-based automatic LNS for head-and-neck cancer is accurate, efficient, and reduces interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Graph Neural Networks for low-energy event classification & reconstruction in IceCube

IceCube, a cubic-kilometer array of optical sensors built to detect atmospheric and astrophysical neutrinos between 1 GeV and 1 PeV, is deployed 1.45 km to 2.45 km below the surface of the ice sheet at the South Pole. The classification and reconstruction of events from the in-ice detectors play a central role in the analysis of data from IceCube. Reconstructing and classifying events is a challenge due to the irregular detector geometry, inhomogeneous scattering and absorption of light in the ice and, below 100 GeV, the relatively low number of signal photons produced per event. To address this challenge, it is possible to represent IceCube events as point cloud graphs and use a Graph Neural Network (GNN) as the classification and reconstruction method. The GNN is capable of distinguishing neutrino events from cosmic-ray backgrounds, classifying different neutrino event types, and reconstructing the deposited energy, direction and interaction vertex. Based on simulation, we provide a comparison in the 1 GeV–100 GeV energy range to the current state-of-the-art maximum likelihood techniques used in current IceCube analyses, including the effects of known systematic uncertainties. For neutrino event classification, the GNN increases the signal efficiency by 18% at a fixed background rate, compared to current IceCube methods. Alternatively, the GNN offers a reduction of the background (i.e. false positive) rate by over a factor 8 (to below half a percent) at a fixed signal efficiency. For the reconstruction of energy, direction, and interaction vertex, the resolution improves by an average of 13%–20% compared to current maximum likelihood techniques in the energy range of 1 GeV–30 GeV. The GNN, when run on a GPU, is capable of processing IceCube events at a rate nearly double of the median IceCube trigger rate of 2.7 kHz, which opens the possibility of using low energy neutrinos in online searches for transient events.

47 OTHER INSTRUMENTATION↗

A spatially regularized detector for emergent/re-emergent disease outbreaks

Early detection of outbreaks caused by emergent pathogens, using epidemiological surveillance data i.e., daily case counts, is difficult. This is because the data tend to be noisy during the early epoch of the outbreak. In contrast, the spread-rate of the disease tends to be well-behaved, as it depends only on the mixing patterns of the population and the characteristics of the pathogen, neither of which behave erratically in space-time. In this report, we explore whether the spread-rate can be used for epidemiological surveillance, conditional on case count data. Estimating the spread-rate from case count data allows us to exploit exogenous information, e.g., incubation period distributions etc., which can considerably smooth out any erratic temporal behavior. Further, epidemiological dynamics are spatially correlated, and if case counts are available for multiple areal units e.g., counties, these correlations could potentially be used to suppress noise in the early epoch data. These exogenous information and structure are not exploited by conventional syndromic surveillance detectors to extract a well-behaved latent variable for monitoring purposes. The technical challenge lies in the estimation of the spread-rate field jointly over a collection of areal units; further, the spread-rate varies over time. We develop a method based on mean-field variational inference to approximately estimate the spread-rate field, using a Gaussian Random Field Model for spatial regularization. The method is tested on the estimation of spread-rate in the thirty-three counties of New Mexico and detect the arrival of the Fall 2020 COVID-19 wave in September 2020. We find that the method is scalable, but underestimates the uncertainty in the estimated spread-rate field. We detect the arrival of the Fall 2020 wave a week ahead of conventional syndromic surveillance algorithms, but our simplistic detection algorithm, based on simple anomaly detection, suffers from a high false positive rate, similar to conventional detectors.

59 BASIC BIOLOGICAL SCIENCES↗

Pulmonary nodule detection in CT images based on shape constraint CV model

Purpose: Accurate detection of pulmonary nodules remains a technical challenge in computer-aided diagnosis systems because some nodules may adhere to the blood vessels or the lung wall, which have low contrast compared to the surrounding tissues. In this paper, the analysis of typical shape features of candidate nodules based on a shape constraint Chan–Vese (CV) model combined with calculation of the number of blood branches adhered to nodule candidates is proposed to reduce false positive (FP) nodules from candidate nodules. Methods: The proposed scheme consists of three major stages: (1) Segmentation of lung parenchyma from computed tomography images. (2) Extraction of candidate nodules. (3) Reduction of FP nodules. A gray level enhancement combined with a spherical shape enhancement filter is introduced to extract the candidate nodules and their sphere-like contour regions. FPs are removed by analysis of the typical shape features of nodule candidates based on the CV model using spherical constraint and by investigating the number of blood branches adhered to the candidate nodules. The constrained shapes of CV model are automatically achieved from the extracted candidate nodules. Results: The detection performance was evaluated on 127 nodules of 103 cases including three types of challenging nodules, which are juxta-pleural nodules, juxta-vascular nodules, and ground glass opacity nodules. The free-receiver operating characteristic (FROC) curve shows that the proposed method is able to detect 88% of all the nodules in the data set with 4 FPs per case. Conclusions: Evaluation shows that the authors’ method is feasible and effective for detection of three types of nodules in this study.

60 APPLIED LIFE SCIENCES↗

Numerical convergence and validation of the DIMP inverse particle transport model

The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector re-sponses (using the adjoint transport solution) with measured responses. DIMP performs well with for-ward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search vol-ume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.

42 ENGINEERING↗

Multi‐Model Ensembles in Ecosystem Modeling: Challenges and Best Practices for Decision‐Making

Ecosystem models are increasingly central to the decision-making for environmental policy, conservation planning, and climate-related investments. Yet, the growing reliance on Multi-Model Ensembles (MMEs) of ecosystem models by practitioners and policymakers, sometimes under tight timelines and imperfect information, has frequently outpaced the scientific rigor required to ensure ensemble reliability. Here, MMEs refer to approaches that combine targeted predictions from multiple models with the expectation of improving robustness and quantifying predictive uncertainty. Poorly designed MMEs may create a false sense of confidence and lead to suboptimal policy and market decisions. This perspective argues that robust decision-making-relevant MMEs must be grounded on two pillars: (1) rigorous Model Intercomparison Projects (MIPs), which identify inter-model agreement and disagreement, characterize model uncertainties, and evaluate robustness with observationally based benchmarks—MIPs' diagnostic evaluation is so critical that it must be needed to drive MME's decision in model selection and weighting, especially when only a limited number of models available; and (2) co-design by both stakeholders and scientists to ensure that scenarios, metrics and uncertainty requirements provide decision-relevant information. Building upon the past success and lessons from the existing MIPs-MMEs efforts (e.g., climate/Earth system/crop), we derived the theoretical basis for MMEs, addressed their specific challenges in ecosystem modeling, and highlighted proper consideration of model numbers and diversity, risk of model inter-dependence, effective calibration of model parameters, possible overdue of some ecosystem model development, critical roles of open benchmark data across a wide range of conditions, and suggested use of Artificial Intelligence to support MIPs-MMEs. We highlighted the under-recognized opportunity for MIPs and MMEs to drive scientific progress and innovation through identifying better performing models, systematic benchmarking, feedback loops, and targeted model improvement. By following actionable best practice guidelines, MMEs can evolve from ad hoc aggregation of models into a trusted backbone of environmental policy and decision-making.

ecosystem modeling↗

Advancing Aviation Security

Air travel is a popular mode of transportation. Each year, more than 600 million people board U.S. flights for business or pleasure. As demonstrated on 9/11, a coordinated terrorist strike on commercial airlines has devastating consequences where many lives could be lost and the nation’s economy could be crippled. The Transportation Security Administration (TSA) has worked diligently to enhance security at airports and on flights so that people and cargo can continue to move freely. Today, all passengers and every piece of checked or carry-on luggage are screened before they are permitted on an aircraft. X-ray systems and walk-through metal detectors allow security personnel to identify dangerous metal objects, such as guns and knives. A more complex problem is the detection of explosives, where detection technologies such as multiple-energy X-ray radiography, computed tomography (CT), full body scanners using millimeter wave and X-ray backscatter and other techniques are used to screen for explosives hidden in luggage, in cargo and on the people boarding the aircraft. Scientists and engineers at the Lawrence Livermore National Laboratory (LLNL) are working with the Department of Homeland Security (DHS), Science and Technology Directorate (S&T), Explosives Division (EXD) to help improve aviation security by evaluating and enhancing the performance of next-generation explosives detection technologies. LLNL is providing subject matter expertise to TSA for their multi-billion dollar procurements of explosive detection system (EDS) for the nation’s airports and provides recommendations for process and system improvements. To further improve aviation security, EXD is funding research at LLNL to develop advanced explosives detection technologies that can more accurately discriminate between a wide range of explosives and non-threat materials. One challenge with scanning for explosives is that some nonthreatening materials share similar characteristics with actual threats, leading to false positives or false alarms. When an alarm is generated, security personnel must review the scan images to clear the alarm or manually open and verify the bag’s contents, which can increase labor costs and lead to passenger delays. The Livermore efforts currently focus on CT-based applications. First developed for the medical field as a method for diagnosing disease, X-ray CT has become instrumental in various industrial Non-Destructive Evaluation (NDE) applications. Explosives detection equipment that incorporates CT uses a broad-spectrum X-ray beam to capture projections of an object, in particular, the objects inside a piece of luggage. The CT system then applies complex reconstruction algorithms to the projections to produce a three-dimensional representation of the luggage and its contents. Automated threat-detection algorithms (also referred to as threat-recognition algorithms) further process the images to separate each item and flag potential threats for further review (see Figure 1). Transportation security officers can then examine these images and the relevant data to determine whether further interrogation is needed. LLNL has also performed research on advanced X-ray carry-on bag inspection systems and is helping to better understand the performance of X-ray backscatter and millimeter wave passenger screening systems.

42 ENGINEERING↗

A robust and efficient approach to detect 3D rectal tubes from CT colonography

Purpose: The rectal tube (RT) is a common source of false positives (FPs) in computer-aided detection (CAD) systems for CT colonography. A robust and efficient detection of RT can improve CAD performance by eliminating such ''obvious'' FPs and increase radiologists' confidence in CAD. Methods: In this paper, we present a novel and robust bottom-up approach to detect the RT. Probabilistic models, trained using kernel density estimation on simple low-level features, are employed to rank and select the most likely RT tube candidate on each axial slice. Then, a shape model, robustly estimated using random sample consensus (RANSAC), infers the global RT path from the selected local detections. Subimages around the RT path are projected into a subspace formed from training subimages of the RT. A quadratic discriminant analysis (QDA) provides a classification of a subimage as RT or non-RT based on the projection. Finally, a bottom-top clustering method is proposed to merge the classification predictions together to locate the tip position of the RT. Results: Our method is validated using a diverse database, including data from five hospitals. On a testing data with 21 patients (42 volumes), 99.5% of annotated RT paths have been successfully detected. Evaluated with CAD, 98.4% of FPs caused by the RT have been detected and removed without any loss of sensitivity. Conclusions: The proposed method demonstrates a high detection rate of the RT path, and when tested in a CAD system, reduces FPs caused by the RT without the loss of sensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated aortic calcium scoring on low-dose chest computed tomography

Purpose: Thoracic computed tomography (CT) scans provide information about cardiovascular risk status. These scans are non-ECG synchronized, thus precise quantification of coronary calcifications is difficult. Aortic calcium scoring is less sensitive to cardiac motion, so it is an alternative to coronary calcium scoring as an indicator of cardiovascular risk. The authors developed and evaluated a computer-aided system for automatic detection and quantification of aortic calcifications in low-dose noncontrast-enhanced chest CT. Methods: The system was trained and tested on scans from participants of a lung cancer screening trial. A total of 433 low-dose, non-ECG-synchronized, noncontrast-enhanced 16 detector row examinations of the chest was randomly divided into 340 training and 93 test data sets. A first observer manually identified aortic calcifications on training and test scans. A second observer did the same on the test scans only. First, a multiatlas-based segmentation method was developed to delineate the aorta. Segmented volume was thresholded and potential calcifications (candidate objects) were extracted by three-dimensional connected component labeling. Due to image resolution and noise, in rare cases extracted candidate objects were connected to the spine. They were separated into a part outside and parts inside the aorta, and only the latter was further analyzed. All candidate objects were represented by 63 features describing their size, position, and texture. Subsequently, a two-stage classification with a selection of features and k-nearest neighbor classifiers was performed. Based on the detected aortic calcifications, total calcium volume score was determined for each subject. Results: The computer system correctly detected, on the average, 945 mm{sup 3} out of 965 mm{sup 3} (97.9%) calcified plaque volume in the aorta with an average of 64 mm{sup 3} of false positive volume per scan. Spearman rank correlation coefficient was {rho}=0.960 between the system and the first observer compared to {rho}=0.961 between the two observers. Conclusions: Automatic calcium scoring in the aorta thus appears feasible with good correlation between manual and automatic scoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE ACS SURVEY OF GALACTIC GLOBULAR CLUSTERS. XI. THE THREE-DIMENSIONAL ORIENTATION OF THE SAGITTARIUS DWARF SPHEROIDAL GALAXY AND ITS GLOBULAR CLUSTERS

We use observations from the Hubble Space Telescope Advanced Camera for Surveys (HST/ACS) study of Galactic globular clusters to investigate the spatial distribution of the inner regions of the disrupting Sagittarius dwarf spheroidal galaxy (Sgr). We combine previously published analyses of four Sgr member clusters located near or in the Sgr core (M54, Arp 2, Terzan 7, and Terzan 8) with a new analysis of diffuse Sgr material identified in the background of five low-latitude Galactic bulge clusters (NGC 6624, 6637, 6652, 6681, and 6809) observed as part of the ACS survey. By comparing the bulge cluster color-magnitude diagrams to our previous analysis of the M54/Sgr core, we estimate distances to these background features. The combined data from four Sgr member clusters and five Sgr background features provide nine independent measures of the Sgr distance and, as a group, provide uniformly measured and calibrated probes of different parts of the inner regions of Sgr spanning 20 Degree-Sign over the face of the disrupting dwarf. This allows us, for the first time, to constrain the three-dimensional orientation of Sgr's disrupting core and globular cluster system and compare that orientation to the predictions of an N-body model of tidal disruption. The density and distance of Sgr debris are consistent with models that favor a relatively high Sgr core mass and a slightly greater distance (28-30 kpc, with a mean of 29.4 kpc). Our analysis also suggests that M54 is in the foreground of Sgr by {approx}2 kpc, projected on the center of the Sgr dSph. While this would imply a remarkable alignment of the cluster and the Sgr nucleus along the line of sight, we cannot identify any systematic effect in our analysis that would falsely create the measured 2 kpc separation. Finally, we find that the cluster Terzan 7 has the most discrepant distance (25 kpc) among the four Sgr core clusters, which may suggest a different dynamical history than the other Sgr core clusters.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopic quantification of projection effects in the SDSS redMaPPer galaxy cluster catalogue

ABSTRACT Projection effects, whereby galaxies along the line of sight to a galaxy cluster are mistakenly associated with the cluster halo, present a significant challenge for optical cluster cosmology. We use statistically representative spectral coverage of luminous galaxies to investigate how projection effects impact the low-redshift limit of the Sloan Digital Sky Survey (SDSS) redMaPPer galaxy cluster catalogue. Spectroscopic redshifts enable us to differentiate true cluster members from false positives and determine the fraction of candidate cluster members viewed in projection. Our main results can be summarized as follows: first, we show that a simple double-Gaussian model can be used to describe the distribution of line-of-sight velocities in the redMaPPer sample; secondly, the incidence of projection effects is substantial, accounting for ∼16 per cent of the weighted richness for the lowest richness objects; thirdly, projection effects are a strong function of richness, with the contribution in the highest richness bin being several times smaller than for low-richness objects; fourthly, our measurement has a similar amplitude to state-of-the-art models, but finds a steeper dependence of projection effects on richness than these models; and fifthly, the slope of the observed velocity dispersion–richness relation, corrected for projection effects, implies an approximately linear relationship between the true, three-dimensional halo mass and three-dimensional richness. Our results provide a robust, empirical description of the impact of projection effects on the SDSS redMaPPer cluster sample and exemplify the synergies between optical imaging and spectroscopic data for studies of galaxy cluster astrophysics and cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

A support vector machine (SVM) for predicting preferred treatment position in radiotherapy of patients with breast cancer

Purpose: NYU 05-181 protocol compared the CT simulation in both supine and prone positions for 400 patients with breast cancer (200 left-breast and 200 right-breast) to identify which setup is better at sparing heart and lung involvement in the treatment process. The results demonstrated that all right-breast patients benefited from the prone treatment position, while for left-breast patients, 85% were better treated prone and 15% were better treated supine. Using the clinical data collected from this protocol, the authors aimed at developing an automated tool capable of identifying which of the left-breast cancer patients are better treated supine without obtaining a second CT scan in the supine position. Methods: Prone CT scans from 198 of the 200 left-breast cancer patients enrolled in NYU 05-181 protocol were deidentified and exported to a dedicated research planning workstation. Three-dimensional geometric features of the organs at risk and tumor bed were extracted. A two-stage classifier was used to classify patients into the prone class or the supine class. In the first stage, the authors use simple thresholding to divide the patients into two groups based on their in-field heart volume. For patients with in-field heart volume {<=}0.1 cc, the prone position was chosen as the preferred treatment position. Patients with in-field heart volume >0.1 cc will be further classified in the second stage by a weighted support vector machine (SVM). The weight parameters of the SVM were adjusted to maximize the specificity [true-supine/(true-supine+false-prone)] at the cost of lowering but still maintaining reasonable sensitivity [true-prone/(true-prone+false-supine)]. The authors used K-fold cross validations to test the performance of the SVM classifier. A feature selection algorithm was also used to identify features that give the best classification performance. Results: After the first stage, 49 of the 198 left-breast cancer patients were found to have >0.1 cc of in-field heart volume. The three geometric features of heart orientation, distance between heart and tumor, and in-field lung were selected by the feature selection algorithm in the second stage of the two-stage classifier to give the best predefined weighted accuracy. The overall sensitivity and specificity of the proposed method were found to be 90.4% and 99.3%, respectively. Using two-stage classification, the authors reduced the proportion of prone-treated patients that need a second supine CT scan down to 16.3/170 or 9.6%, as compared to 21/170 or 12.4% when the authors use only the first stage (thresholding) for classification. Conclusions: The authors' study showed that a feature-based classifier is feasible for predicting the preferred treatment position, based on features extracted from prone CT scans. The two-stage classifier achieved very high specificity at an acceptable expense of sensitivity.

60 APPLIED LIFE SCIENCES↗

Virtual tool mark generation for efficient striation analysis in forensic science

In 2009, a National Academy of Sciences report called for investigation into the scienti c basis behind tool mark comparisons (National Academy of Sciences, 2009). Answering this call, Chumbley et al. (2010) attempted to prove or disprove the hypothesis that tool marks are unique to a single tool. They developed a statistical algorithm that could, in most cases, discern matching and non-matching tool marks made at di erent angles by sequentially numbered screwdriver tips. Moreover, in the cases where the algorithm misinterpreted a pair of marks, an experienced forensics examiner could discern the correct outcome. While this research served to con rm the basic assumptions behind tool mark analysis, it also suggested that statistical analysis software could help to reduce the examiner&#x27;s workload. This led to a new tool mark analysis approach, introduced in this thesis, that relies on 3D scans of screwdriver tip and marked plate surfaces at the micrometer scale from an optical microscope. These scans are carefully cleaned to remove noise from the data acquisition process and assigned a coordinate system that mathematically de nes angles and twists in a natural way. The marking process is then simulated by using a 3D graphics software package to impart rotations to the tip and take the projection of the tip&#x27;s geometry in the direction of tool travel. The edge of this projection, retrieved from the 3D graphics software, becomes a virtual tool mark. Using this method, virtual marks are made at increments of 5 and compared to a scan of the evidence mark. The previously developed statistical package from Chumbley et al. (2010) performs the comparison, comparing the similarity of the geometry of both marks to the similarity that would occur due to random chance. The resulting statistical measure of the likelihood of the match informs the examiner of the angle of the best matching virtual mark, allowing the examiner to focus his/her mark analysis on a smaller range of angles. Preliminary results are quite promising. In a study with both sides of 6 screwdriver tips and 34 corresponding marks, the method distinguished known matches from known non-matches with zero false positive matches and only two matches mistaken for non-matches. For matches, it could predict the correct marking angle within 5-10 . Moreover, on a standard desktop computer, the virtual marking software is capable of cleaning 3D tip and plate scans in minutes and producing a virtual mark and comparing it to a real mark in seconds. These results support several of the professional conclusions of the tool mark analysis com- munity, including the idea that marks produced by the same tool only match if they are made at similar angles. The method also displays the potential to automate part of the comparison process, freeing the examiner to focus on other tasks, which is important in busy, backlogged crime labs. Finally, the method o ers the unique chance to directly link an evidence mark to the tool that produced it while reducing potential damage to the evidence.

42 ENGINEERING↗