Trans-Barrier Communication Device Characterization Using Frequency Fitting Methods.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
The Magnox Decommissioning Project is actively progressing clean-up and decommissioning of 12 reactor sites across England, Scotland and Wales. Funded and directed by the United Kingdom's Nuclear Decommissioning Authority (NDA) and managed by the Cavendish Fluor Partnership (CFP), the Magnox Decommissioning Project introduces a wide range of radiological and industrial hazards warranting deployment of remote technologies to safely de-inventory, decontaminate and decommission a vast array of nuclear facilities. The Magnox Decommissioning Project encompasses 22 former Magnox nuclear power production reactors across 10 reactor sites and five research/test reactors at two former research sites. Decommissioning activities have been underway at some sites for nearly 20 years with early focus on retrieving and stabilising wastes and draining and stabilising spent fuel ponds. The Magnox decommissioning strategy invokes a programme perspective to drive consistency in tackling similar decommissioning and waste challenges across multiple sites. Programme central teams have worked with technology suppliers to foster learning from industry experience to develop and deploy tooling and robotics. The programme approach has also facilitated learning from one site to the next. In many cases, this central programme approach has promoted an evolution of technologies resulting in optimisation of simple remote tooling. In other instances, collaboration with suppliers is producing state-of-the-art technologies to tackle more unique challenges including, most recently, early demonstration of laser cutting for reactor vessel dismantling. This paper will outline the programme management approach and the scalable optioneering process Magnox employs to select the engineered controls and technologies used in decommissioning and waste management activities. It will provide an overview of the broad range of remote tooling and robotics deployed across the 12 Magnox sites by exploring some specific examples. Lastly, the paper will summarise key lessons learned in the now extensive history of selecting and using remote technologies to decommission Magnox nuclear facilities. (authors)
Conventional power-generation plants, including nuclear plants, have been traditionally designed to provide a steady baseload energy capacity, optimizing output efficiency while minimizing variable costs. However, the growing adoption of large-scale renewable energy-generation systems, which rely on intermittent sources such as solar and wind, has introduced more variability into the energy supply in interconnected electricity grids. As a result, the next generation of power plants needs to operate in what is known as the load-following mode, requiring flexible adjustments in electricity production to align with the energy demand on the grid. This transition from the steady baseload operation to load-following operating conditions can significantly increase the number of times various plant components are exposed to transient stresses. This increased thermo-mechanical cycling can lead to accelerated material degradation, thereby elevating the risk of premature failure of a component. It becomes imperative to conduct a comprehensive analysis of fatigue, creep-fatigue, and stress corrosion cracking life, to assess the resilience of the various engineering components under these flexible load-following operating conditions. This study aims to develop a comprehensive numerical model of a light-water reactor pressure vessel (RPV) to investigate its degradation under various operating scenarios. This coupled thermo-mechanical finite element analysis evaluated the stress response of the RPV caused by considering fluctuations in thermal and mechanical loads caused by the varying pressure and temperature occurring during the load-following operation. Critical locations on the RPV are subsequently identified based on the stress response. The stress intensity factors for the postulated flaws at those locations are then calculated, followed by an evaluation of the reactor's life in accordance with the ASME Boiler and Pressure Vessel Code Section XI. This comprehensive life assessment covers a number of transients expected during the flexible load-following operation, providing invaluable insights into the RPV's structural integrity. Moreover, the development methodology can be adapted to other reactor components, as well as components of conventional power stations that are affected by varying operating conditions.
Bayesian analyses of the full-shape clustering of Dark Energy Spectroscopic Instrument (DESI) Data Release 1 (DR1) exhibit prior-volume projection effects, whereby weakly constrained nuisance parameters of the Effective Field Theory of Large Scale Structure (EFTofLSS) shift marginalized cosmological posteriors away from the posterior maximum. We reanalyze DESI DR1 power spectrum multipoles using two complementary mitigation strategies: (i) nonlinear orthogonalization to decorrelate nuisance and cosmological parameter priors, and (ii) a fully reparameterization-invariant Jeffreys prior over all EFTofLSS coefficients, evaluated on-the-fly via closed-form Jacobians. Including data from DESI, Big-Bang Nuclesynthesis and a constraint on $n_{\mathrm{s}}$, baseline priors lead to multi-$σ$ projection in the Hubble parameter $H_{0}$ and dark energy equation of state parameters $w_{0}$ and $w_{a}$; the Jeffreys prior successfully recenters these posteriors to enclose the maximum a posteriori estimate within the 68% credible regions, demonstrating clear mitigation of projection effects for these late-time expansion parameters. A hybrid Jeffreys+baseline-Gaussian configuration controls residual over-broad tails in the physical cold dark matter density $ω_{\mathrm{c}}$ while preserving the volume correction, and is our favoured approach. We compare the credible intervals derived using our methodology to those obtained using Halo Occupation Distribution (HOD)-informed priors and to confidence intervals derived using frequentist profile likelihood analyses, finding agreement in both central values and degeneracy directions in the $w_{0}$--$w_{a}$ plane. This demonstrates that, once projection effects are properly controlled, we can make robust inferences about the late-time cosmological expansion independent of the statistical framework adopted.
Tensor decompositions (e.g., higher-order analogues of matrix decompositions) are powerful tools for data analysis. In particular, the CANDECOMP/PARAFAC (CP) model has proved useful in many applications such chemometrics, signal processing, and web analysis; see for details. The problem of computing the CP decomposition is typically solved using an alternating least squares (ALS) approach. We discuss the use of optimization-based algorithms for CP, including how to efficiently compute the derivatives necessary for the optimization methods. Numerical studies highlight the positive features of our CPOPT algorithms, as compared with ALS and Gauss-Newton approaches.
This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Pump House at Mount Crested Butte in the East River Watershed. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format ER-X-Y, where ER refers to East River, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, ER-PHS, ER-LMC, ER-LMF, and ER-SMN are associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and ER-RBTn (upslope n=1) are sampling transects during the 2019 Rootball Campaign. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.
This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Trail Creek. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format TR-X-Y, where TR refers to Trail Creek, X is the treatment block identifier, and Y is the location identifier. Specifically, TR-ASCC1 is the control treatment block under the Adaptive Silviculture for Climate Change (ASCC) project, and TR-ASCC2 is the clear-cut treatment block. TR-ASCC-EHSn is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and TR-ASCC-ERTn (upslope n=1) are ecohydrology sites along the electrical resistivity tomography transects. The sample and location information can be found in metadata.csv, and the data from the soil sensors will be included in a future data version when the observation period becomes sufficiently long for data analysis. Sampling and Measurements Each sample falls into one of the two sampling methods – (1) intact cores or (2) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. The intact cores were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.
This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors at Snodgrass Mountain. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format SG-X-Y, where SG refers to Snodgrass Mountain, X is the location identifier, and Y is the depth identifier at the same X (shallow Y=1). Specifically, SG-EHS is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and SG-ERTn (upslope n=1) are points along the Snodgrass electrical resistivity tomography transect not associated with the existing site names in the directory. The sample and location information can be found in metadata.csv. Sampling and Measurements Each sample falls into one of the three sampling methods – (1) intact cores, (2) repacked samples, or (3) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. Both intact cores and repacked samples were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores and in-situ soil sensors could be prioritized because these sampling methods are less destructive. While the repacked samples were packed to the target bulk density (estimated post-sampling, when sample volume was known), these samples had altered pore structures. Nevertheless, intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method also has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.
Histograms of counted events are Poisson distributed, but are typically fitted without justification using nonlinear least squares fitting. The more appropriate maximum likelihood estimator (MLE) for Poisson distributed data is seldom used. We extend the use of the Levenberg-Marquardt algorithm commonly used for nonlinear least squares minimization for use with the MLE for Poisson distributed data. In so doing, we remove any excuse for not using this more appropriate MLE. We demonstrate the use of the algorithm and the superior performance of the MLE using simulations and experiments in the context of fluorescence lifetime imaging. Scientists commonly form histograms of counted events from their data, and extract parameters by fitting to a specified model. Assuming that the probability of occurrence for each bin is small, event counts in the histogram bins will be distributed according to the Poisson distribution. We develop here an efficient algorithm for fitting event counting histograms using the maximum likelihood estimator (MLE) for Poisson distributed data, rather than the non-linear least squares measure. This algorithm is a simple extension of the common Levenberg-Marquardt (L-M) algorithm, is simple to implement, quick and robust. Fitting using a least squares measure is most common, but it is the maximum likelihood estimator only for Gaussian-distributed data. Non-linear least squares methods may be applied to event counting histograms in cases where the number of events is very large, so that the Poisson distribution is well approximated by a Gaussian. However, it is not easy to satisfy this criterion in practice - which requires a large number of events. It has been well-known for years that least squares procedures lead to biased results when applied to Poisson-distributed data; a recent paper providing extensive characterization of these biases in exponential fitting is given. The more appropriate measure based on the maximum likelihood estimator (MLE) for the Poisson distribution is also well known, but has not become generally used. This is primarily because, in contrast to non-linear least squares fitting, there has been no quick, robust, and general fitting method. In the field of fluorescence lifetime spectroscopy and imaging, there have been some efforts to use this estimator through minimization routines such as Nelder-Mead optimization, exhaustive line searches, and Gauss-Newton minimization. Minimization based on specific one- or multi-exponential models has been used to obtain quick results, but this procedure does not allow the incorporation of the instrument response, and is not generally applicable to models found in other fields. Methods for using the MLE for Poisson-distributed data have been published by the wider spectroscopic community, including iterative minimization schemes based on Gauss-Newton minimization. The slow acceptance of these procedures for fitting event counting histograms may also be explained by the use of the ubiquitous, fast Levenberg-Marquardt (L-M) fitting procedure for fitting non-linear models using least squares fitting (simple searches obtain {approx}10000 references - this doesn't include those who use it, but don't know they are using it). The benefits of L-M include a seamless transition between Gauss-Newton minimization and downward gradient minimization through the use of a regularization parameter. This transition is desirable because Gauss-Newton methods converge quickly, but only within a limited domain of convergence; on the other hand the downward gradient methods have a much wider domain of convergence, but converge extremely slowly nearer the minimum. L-M has the advantages of both procedures: relative insensitivity to initial parameters and rapid convergence. Scientists, when wanting an answer quickly, will fit data using L-M, get an answer, and move on. Only those that are aware of the bias issues will bother to fit using the more appropriate MLE for Poisson deviates. However, since there is a simple, analytical formula for the appropriate MLE measure for Poisson deviates, it is inexcusable that least squares estimators are used almost exclusively when fitting event counting histograms. There have been ways found to use successive non-linear least squares fitting to obtain similarly unbiased results, but this procedure is justified by simulation, must be re-tested when conditions change significantly, and requires two successive fits. There is a great need for a fitting routine for the MLE estimator for Poisson deviates that has convergence domains and rates comparable to the non-linear least squares L-M fitting. We show in this report that a simple way to achieve that goal is to use the L-M fitting procedure not to minimize the least squares measure, but the MLE for Poisson deviates.
High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)
Since the discovery of the first eight gamma-ray millisecond pulsars (MSPs) by the Fermi Large Area Telescope, this population has been steadily expanding. Four of the more recent detections, PSR J0034-0534, PSR J1939+2134 (B1937+21; the first MSP ever discovered), PSR J1959+2048 (B1957+20; the first discovery of a black widow system), and PSR J2214+3000, exhibit a phenomenon not present in the original discoveries: nearly phase-aligned radio and gamma-ray light curves (LCs). To account for the phase alignment, we explore models where both the radio and gamma-ray emission originate either in the outer magnetosphere near the light cylinder or near the polar caps. Using a Markov Chain Monte Carlo technique to search for best-fit model parameters, we obtain reasonable LC fits for the first three of these MSPs in the context of 'altitude-limited' outer gap (alOG) and two-pole caustic (alTPC) geometries (for both gamma-ray and radio emission). These models differ from the standard outer gap (OG)/two-pole caustic (TPC) models in two respects: the radio emission originates in caustics at relatively high altitudes compared to the usual conal radio beams, and we allow both the minimum and maximum altitudes of the gamma-ray and radio emission regions to vary within a limited range (excluding the minimum gamma-ray altitude of the alTPC model, which is kept constant at the stellar radius, and that of the alOG model, which is set to the position-dependent null charge surface altitude). Alternatively, phase-aligned solutions also exist for emission originating near the stellar surface in a slot gap scenario ('low-altitude slot gap' (laSG) models). We find that the alTPC models provide slightly better LC fits than the alOG models, and both of these give better fits than the laSG models (for the limited range of parameters considered in the case of the laSG models). Thus, our fits imply that the phase-aligned LCs are likely of caustic origin, produced in the outer magnetosphere, and that the radio emission for these pulsars may come from close to the light cylinder. In addition, we were able to constrain the minimum and maximum emission altitudes with typical uncertainties of {approx}30% of the light cylinder radius. Our results therefore describe a third gamma-ray MSP subclass, in addition to the two previously found by Venter et al.: those with LCs fit by standard OG/TPC models and those with LCs fit by pair-starved polar cap models.
Simple models of weakly interacting massive particles (WIMPs) predict dark matter annihilations into pairs of electroweak gauge bosons, Higgses or tops, which through their subsequent cascade decays produce a spectrum of gamma rays. Intriguingly, an excess in gamma rays coming from near the Galactic center has been consistently observed in Fermi data. A recent analysis by the Fermi collaboration confirms these earlier results. Taking into account the systematic uncertainties in the modelling of the gamma ray backgrounds, we show for the first time that this excess can be well fit by these final states. In particular, for annihilations to (WW, ZZ, hh, tt{sup -bar}), dark matter with mass between threshold and approximately (165, 190, 280, 310) GeV gives an acceptable fit. The fit range for bb{sup -bar} is also enlarged to 35 GeV≲m{sub χ}≲165 GeV. These are to be compared to previous fits that concluded only much lighter dark matter annihilating into b, τ, and light quark final states could describe the excess. We demonstrate that simple, well-motivated models of WIMP dark matter including a thermal-relic neutralino of the MSSM, Higgs portal models, as well as other simplified models can explain the excess.
Background Fecal immunochemical test (FIT) performance for colorectal cancer screening varies by age and sex, yet most FIT-based screening programs use uniform positivity thresholds. This study assessed the potential benefits of stratifying FIT thresholds based on age and sex. Methods We conducted a meta-analysis of FIT sensitivity and specificity at various positivity thresholds by age and sex. We then used these estimates in 2 microsimulation models of colorectal cancer and projected lifetime clinical outcomes, incremental costs, and quality-adjusted life-years (QALYs) gained from age- and sex-stratified FIT strategies. FIT thresholds ranged from 10 to 50 µg hemoglobin per gram of feces. Results For current uniform FIT screening (20 µg hemoglobin/gram of feces), models projected 85.67 to 122.15 QALYs gained at incremental costs of ‒$982 to $504 per 1000 individuals compared with no screening. At equivalent costs to current uniform screening, only 1 model found stratified FIT approaches cost-effective, yielding a marginal increase of 1.04 and 1.10 QALYs gained/1000 female and male individuals, respectively. At a willingness-to-pay threshold of $100 000/QALYs gained, both models found stratified FIT cutoffs to be the best strategy, with cutoffs being equal to or higher for males and lowest at older ages (70-75 years). Uniform strategies showed comparable effectiveness, falling within 1 quality-adjusted life-day per person of efficient strategies at up to $112 more per person. Results were sensitive to FIT test performance characteristics and 1-time setup costs. Conclusion Stratifying FIT thresholds by age and sex may be cost-effective compared to current screening. The gain in expected health benefits with stratified FIT screening, however, is likely small.
Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism. The net correlation functions needed to fit the PSD data for each sample comprised the sum of two terms with different cutoff lengths and different self-affine fractal exponents. At zero distance these correlation functions added up to yield net values of σ 2 = (2) 2 and (71) 2 Å 2 for the smooth and rough samples, respectively. X-ray scattering data were obtained at beamline 1-BM of the Advanced Photon Source. Data and fits at values of q z = 0.05 and 0.10 Å −1 for the smooth sample are reported. Good fits for the smooth sample were obtained at both q z values simultaneously, that is, identical fitting parameters were applied at both values of q z . The smooth sample also exhibited weak Yoneda wings and a clear distinction between the strong specular scattering and the weak diffuse scattering. Data for the rough sample were qualitatively different and exhibited very weak scattering at the specular condition in contrast to extremely large Yoneda wings. Fits for the rough sample are reported for q z = 0.04, 0.05, and 0.06 Å −1 . Although the large Yoneda wings could be fit quite well in both position and amplitude, scattering near the specular condition could not be equally well fit by applying the same fitting parameters at all values of q z . Albeit imperfect, best-fitting results at the specular condition were obtained by invoking only diffuse scattering, that is, without including a separate theoretical expression for specular scattering.
Well-defined productivity–precipitation relationships of ecosystems are needed as benchmarks for the validation of land models used for future projections. The productivity–precipitation relationship may be studied in two ways: the spatial approach relates differences in productivity to those in precipitation among sites along a precipitation gradient (the spatial fit, with a steeper slope); the temporal approach relates interannual productivity changes to variation in precipitation within sites (the temporal fits, with flatter slopes). Precipitation–reduction experiments in natural ecosystems represent a complement to the fits, because they can reduce precipitation below the natural range and are thus well suited to study potential effects of climate drying. Here, we analyse the effects of dry treatments in eleven multiyear precipitation–manipulation experiments, focusing on changes in the temporal fit. We expected that structural changes in the dry treatments would occur in some experiments, thereby reducing the intercept of the temporal fit and displacing the productivity–precipitation relationship downward the spatial fit. Seventy two percent of expiriments showed that dry treatments did not alter the temporal fit. This implies that current temporal fits are to be preferred over the spatial fit to benchmark land-model projections of productivity under future climate within the precipitation ranges covered by the experiments. Moreover, in two experiments, the intercept of the temporal fit unexpectedly increased due to mechanisms that reduced either water loss or nutrient loss. The expected decrease of the intercept was observed in only one experiment, and only when distinguishing between the late and the early phases of the experiment. This implies that we currently do not know at which precipitation–reduction level or at which experimental duration structural changes will start to alter ecosystem productivity. Our study highlights the need for experiments with multiple, including more extreme, dry treatments, to identify the precipitation boundaries within which the current temporal fits remain valid.
Purpose: Commissioning data for intensity modulated proton therapy (IMPT) must be post-processed by fits to ad-hoc functions to derive the dose calculation kernel parameters in a treatment planning system (TPS). Whether from experimental measurement or Monte Carlo simulation, the limited and noisy nature of such data makes this task very challenging. We present a method to improve the modeling of the lateral dose distribution of clinical energy proton beams in water to commission an in-house IMPT dose calculation engine. Methods: A linear sum of three Gaussian distribution functions was fitted to the lateral dose data in logarithmic scale. Starting values of fitting solutions were determined from the Generalized Highland Approximation. We exhaustively optimized the combinations of data weights with upper bounds of the fitting solutions to minimize confidence intervals of the fitting solutions while maintaining the coefficient of determination (R{sup 2}). Results: Across all energies, average confidence bounds improved 72.88% [Max: 88.28%, Min: 55.05%] for small angle coulomb scattering, 114.25% [409.13%, 66.72%,] for nuclear scattering, and 68.66% [141.09%, 33.27%] for large angle coulomb scattering, while the coefficients of determination of the fits (R{sup 2}) remained comparable. On average R {sup 2} only changed 0.18% and were very close to 1 (approx. 0.999). Wilcoxon signed rank tests comparing unweighted/unbounded fits with weighted/bounded fits averaged 0.0146 (Max: 0.177, Min: 7.05×10−{sup 7}) for small angle Coulomb, 0.0903 (0.945, 7.05×10−{sup 7}) for nuclear, and 0.254 (0.871, 1.86×10−{sup 6}) for large angle Coulomb scattering. This allows rejection of the null hypothesis for small angle Coulomb scattering at the 0.015 level and nuclear interaction at the 0.1 level. Conclusion: Optimal weights assigned to IMPT lateral dose data minimized fitting to stochastic noise in the tail region. Optimizing the upper bounds of fitting parameters improved the robustness of fitting solutions. Both led to a more physically meaningful dose calculation kernel for the TPS. NIH/NCI K25CA168984, Eagles Cancer Research Career Development, The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, Mayo ASU Seed Grant, and The Kemper Marley Foundation.
Electrostatic interactions of mobile charges in solution with the fixed surface charges are known to strongly affect stochastic sensing and electrochemical energy conversion processes at nanodevices or devices with nanostructured interfaces. The key parameter to describe this interaction, surface charge density (SCD), is not directly accessible at nanometer scale and often extrapolated from ensemble values. In this report, the steady-state current–voltage (i–V) curves measured using single conical glass nanopores in different electrolyte solutions are fitted by solving Poisson and Nernst–Planck equations through finite element approach. Both high and low conductivity state currents of the rectified i–V curve are quantitatively fitted in simulation at less than 5% error. The overestimation of low conductivity state current using existing models is overcome by the introduction of an exponential SCD distribution inside the conical nanopore. A maximum SCD value at the pore orifice is determined from the fitting of the high conductivity state current, while the distribution length of the exponential SCD gradient is determined by fitting the low conductivity state current. Quantitative fitting of the rectified i–V responses and the efficacy of the proposed model are further validated by the comparison of electrolytes with different types of cations (K + and Li + ). In conclusion, the gradient distribution of surface charges is proposed to be dependent on the local electric field distribution inside the conical nanopore.