Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Fidelity Requirements with Fast Transients from VSC-HVdc

Fast control afforded by power electronics in highvoltage direct current (HVde) systems, especially voltage-source converter (VSC) based HVde systems, needs to be carefully assessed to identify stability boundaries. While there are several averaged models of VSC-HVdc systems that have been studied with low bandwidth alternating current (ac) system models, there have been limited studies to show the need for high-fidelity models to understand the control interactions between different VSC-HVdc systems as well as with other grid components. In this paper, the fidelity of power electronics and connected grid components like transmission lines are identified based on defined use-cases to understand the stability and impact of the fast control afforded by VSC-HVdc systems. These results will be useful to understand the methods required to study control in VSC-HVdc systems.

Debnath, Suman↗

Dynamic Distribution Voltage Stability Control Using Distributed Energy Resources for Improved Resiliency

The main goal of this paper is to present the development and simulation of a new dynamic voltage stability control technique, with a focus on effective control and coordination of all available reactive power generation resources in a microgrid setting. Both power electronics and synchronous generator based distributed energy resources (DERs), and grid-supporting functions, are considered to accommodate a high penetration of diverse DERs and energy storage by using an enhanced microgrid voltage stabilizer. A systematic controller parameter synthesizing method is employed, and the overall dynamic voltage stability of the system is studied and evaluated with a time-domain dynamic simulation during emergency, hazard and disaster events. The results with the new approach show significant improvements and enhancements on the dynamic voltage profile of the distribution system, leading towards a more resilient grid system with high penetration of diverse DERs during emergency, hazard and disaster events.

Hatipoglu, Kenan↗

A pseudospectral Legendre method for hyperbolic equations with an improved stability condition

A new pseudospectral method is introduced for solving hyperbolic partial differential equations. This method uses different grid points than previously used pseudospectral methods: in fact the grid are related to the zeroes of the Legendre polynomials. The main advantage of this method is that the allowable time step is proportional to the inverse of the number of grid points 1/N rather than to 1/n(2) (as in the case of other pseudospectral methods applied to mixed initial boundary value problems). A highly accurate time discretization suitable for these spectral methods is discussed.

Tal-Ezer, H.↗

A pseudospectral Legendre method for hyperbolic equations with an improved stability condition

A new pseudospectral method is introduced for solving hyperbolic partial differential equations. This method uses different grid points than previously used pseudospectral methods: in fact the grid points are related to the zeroes of the Legendre polynomials. The main advantage of this method is that the allowable time step is proportional to the inverse of the number of grid points 1/N rather than to 1/n(2) (as in the case of other pseudospectral methods applied to mixed initial boundary value problems). A highly accurate time discretization suitable for these spectral methods is discussed.

Tal-Ezer, Hillel↗

Single Stage PLL-less Decoupled Active and Reactive Power Control for Weak Grid Interactive Inverters

This paper presents a single stage phase locked loop-less (PLL-less) active and reactive power (PQ) control for single-phase weak grid interactive inverters. The absence of the PLL requirement in the proposed PQ control enhances the stability margin comparing to conventional current control approaches in both the stationary or the synchronous reference frame. Additionally, the proposed control scheme enables direct PQ control with a single loop control structure. This paper demonstrates that the proposed PLL-less PQ control scheme is asymptotically stable if the controller gains are positive. The necessary conditions for supplying the rated active power into the weak grid are derived. The provided analysis shows that certain amount of reactive power injection is necessary to avoid point of common coupling (PCC) voltage collapse when the rated active power is injected into the weak grid. Several case studies are provided to demonstrate the performance of the proposed PLL-less PQ control scheme under weak grid condition.

Khan, Ahmad↗

Distributed Dynamic State Estimator, Generator Parameter Estimation and Stability Monitoring Demonstration

This is the final report for this project that was performed in the period: October1, 2009 to June 30, 2013. In this project, a fully distributed high-fidelity dynamic state estimator (DSE) that continuously tracks the real time dynamic model of a wide area system with update rates better than 60 times per second is achieved. The proposed technology is based on GPS-synchronized measurements but also utilizes data from all available Intelligent Electronic Devices in the system (numerical relays, digital fault recorders, digital meters, etc.). The distributed state estimator provides the real time model of the system not only the voltage phasors. The proposed system provides the infrastructure for a variety of applications and two very important applications (a) a high fidelity generating unit parameters estimation and (b) an energy function based transient stability monitoring of a wide area electric power system with predictive capability. Also the dynamic distributed state estimation results are stored (the storage scheme includes data and coincidental model) enabling an automatic reconstruction and “play back” of a system wide disturbance. This approach enables complete play back capability with fidelity equal to that of real time with the advantage of “playing back” at a user selected speed. The proposed technologies were developed and tested in the lab during the first 18 months of the project and then demonstrated on two actual systems, the USVI Water and Power Administration system and the New York Power Authority’s Blenheim-Gilboa pumped hydro plant in the last 18 months of the project. The four main thrusts of this project, mentioned above, are extremely important to the industry. The DSE with the achieved update rates (more than 60 times per second) provides a superior solution to the “grid visibility” question. The generator parameter identification method fills an important and practical need of the industry. The “energy function” based transient stability monitoring opens up new ways to protect the power grid, better manage disturbances, confine their impact and in general improve the reliability and security of the system. Finally, as a by-product of the proposed research project, the developed system is able to “play back” disturbances by a click of a mouse. The importance of this by-product is evident by considering the tremendous effort exerted after the August 2003 blackout to piece together all the disturbance recordings, align them and recreate the sequence of events. This project has moved the state of art from fault recording by individual devices to system wide disturbance recording with “play back” capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-performance room-temperature sodium–sulfur battery enabled by electrocatalytic sodium polysulfides full conversion

Room-temperature sodium–sulfur (RT-Na–S) batteries are highly desirable for grid-scale stationary energy storage due to their low cost; however, short cycling stability caused by the incomplete conversion of sodium polysulfides is a major issue for their application. Herein, we introduce an effective sulfiphilic host, gold nanodots decorated on hierarchical N-doped carbon microspheres (CN/Au/S), to achieve completely reversible conversion reactions in the S cathode by electrocatalyzing the low-kinetics conversion of Na 2 S 4 into NaS 2 (discharge process) or S (charge process). Besides, gold nanodots and N-doped carbon can increase the conductivity of the S cathode and provide strong polar–polar adsorption of sodium polysulfides to alleviate the shuttling effects. When serving as the cathode, the CN/Au/S composite can realize enhanced sulfur utilization, excellent cycling stability, and outstanding rate capability. This work deepens our understanding of the catalytic effect of gold atoms on sulfur molecules, opening a new avenue for cathode design and development of advanced RT-Na–S batteries.

25 ENERGY STORAGE↗

Comparative Study of Data-Driven Area Inertia Estimation Approaches on WECC Power Systems

With the increasing integration of inverter-based resources into the power grid, there has been a notable reduction in system inertia, potentially compromising frequency stability. To assess the suitability of existing area inertia estimation techniques for real-world power systems, this paper presents a rigorous comparative analysis of system identification, measurement reconstruction, and electromechanical oscillation-based area inertia estimation methodologies, specifically applied to the large-scale and multi-area WECC 240-bus power system. Comprehensive results show that the system identification-based approach exhibits superior robustness and accuracy relative to its counterparts.

area inertia estimation↗

Dynamics Informed Optimization for Resilient Energy Systems

Optimal mitigation planning for highly disruptive contingencies to a transmission-level power system requires optimization with dynamic power system constraints, due to the key role of dynamics in system stability to major perturbations. We formulate a generalized disjunctive program to determine optimal grid component hardening choices for protecting against major failures, with differential algebraic constraints representing system dynamics (specifically, differential equations representing generator and load behavior and algebraic equations representing instantaneous power balance over the transmission system). We optionally allow stochastic optimal pre-positioning across all considered failure scenarios, and optimal emergency control within each scenario. This novel formulation allows, for the first time, analyzing the resilience interdependencies of mitigation planning, preventive control, and emergency control. Using all three strategies in concert is particularly effective at maintaining robust power system operation under severe contingencies, as we demonstrate on the Western System Coordinating Council (WSCC) 9-bus test system using synthetic multi-device outage scenarios. Towards integrating our modeling framework with real threats and more realistic power systems, we explore applying hybrid dynamics to power systems. Our work is applied to basic RL circuits with the ultimate goal of using the methodology to model protective tripping schemes in the grid. Finally, we survey mitigation techniques for HEMP threats and describe a GIS application developed to create threat scenarios in a grid with geographic detail.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid Oxide Electrochemical Systems: Material Degradation Processes and Novel Mitigation Approaches

Solid oxide electrochemical systems, such as solid oxide fuel cells (SOFC), solid oxide electrolysis cells (SOEC), and oxygen transport membranes (OTM) enable clean and reliable production of energy or fuel for a range of applications, including, but not limited to, residential, commercial, industrial, and grid-support. These systems utilize solid-state ceramic oxides which offer enhanced stability, fuel flexibility, and high energy conversion efficiency throughout operation. However, the nature of system conditions, such as high temperatures, complex redox atmosphere, and presence of volatile reactive species become taxing on solid oxide materials and limit their viability during long-term operation. Ongoing research efforts to identify the material corrosion and degradation phenomena, as well as discover possible mitigation techniques to extend material efficiency and longevity, is the current focus of the research and industrial community. In this review, degradation processes in select solid oxide electrochemical systems, system components, and comprising materials will be discussed. Overall degradation phenomena are presented and certain degradation mechanisms are discussed. State-of-the-art technologies to mitigate or minimize the above-mentioned degradation processes are presented.

36 MATERIALS SCIENCE↗

On implicit finite-difference simulations of three-dimensional flow

An implicit finite-difference procedure for unsteady three-dimensional flow capable of handling arbitrary geometry through the use of general coordinate transformations is described. Viscous effects are optionally incorporated with a 'thin layer' approximation of the Navier-Stokes equations. An implicit approximate factorization technique is employed so that the small grid sizes required for spatial accuracy and viscous resolution do not impose stringent stability limitations. Results obtained from the program include transonic inviscid and laminar-turbulent solutions about simple body configurations. Comparisons with existing theories and experiments are made. Numerical accuracy and the effect of three-dimensional coordinate singularities are also discussed.

Pulliam, T. H.↗

Component-adaptive grid embedding

One of the major problems related to transonic flow prediction about realistic aircraft configuration is the generation of a suitable grid which encompasses such configurations. In general, each aircraft component (wing, fuselage, nacelle) requires a grid system that is usually incompatible with the grid systems of the other components; thus, the implementation of finite-difference methods for such geometrically-complex configurations is a difficult task. An approach was developed to treat such a problem. The basic idea is to generate different grid systems, each suited for a particular component. Thus, the flow field domain is divided into overlapping subdomains of different topology. These grid systems are then interfaced with each other in such a way that stability, convergence speed and accuracy are maintained.

Atta, E. H.↗

Implicit Finite-Difference Simulations of Three-Dimensional Compressible Flow

An implicit finite-difference procedure for unsteady three-dimensional flow capable of handling arbitrary geometry through the use of general coordinate transformations is described. Viscous effects are optionally incorporated with a "thin-layer" approximation of the Navier-Stokes equations. An implicit approximate factorization technique is employed so that the small grid sizes required for spatial accuracy and viscous resolution do not impose stringent stability limitations. Results obtained from the program include transonic inviscid or viscous solutions about simple body configurations. Comparisons with existing theories and experiments are made. Numerical accuracy and the effect of three-dimensional coordinate singularities are also discussed.

Pulliam, Thomas H.↗

Comparison of AGE and Spectral Methods for the Simulation of Far-Wakes

Turbulent flow simulation methods based on finite differences are attractive for their simplicity, flexibility and efficiency, but not always for accuracy or stability. This report demonstrates that a good compromise is possible with the Advected Grid Explicit (AGE) method. AGE has proven to be both efficient and accurate for simulating turbulent free-shear flows, including planar mixing layers and planar jets. Its efficiency results from its localized fully explicit finite difference formulation (Bisset 1998a,b) that is very straightforward to compute, outweighing the need for a fairly small timestep. Also, most of the successful simulations were slightly under-resolved, and therefore they were, in effect, large-eddy simulations (LES) without a sub-grid-scale (SGS) model, rather than direct numerical simulations (DNS). The principle is that the role of the smallest scales of turbulent motion (when the Reynolds number is not too low) is to dissipate turbulent energy, and therefore they do not have to be simulated when the numerical method is inherently dissipative at its resolution limits. Such simulations are termed 'auto-LES' (LES with automatic SGS modeling) in this report.

Bisset, D. K.↗

Astrophysics of Reference Frame Tie Objects

The Astrophysics of Reference Frame Tie Objects Key Science program will investigate the underlying physics of SIM grid objects. Extragalactic objects in the SIM grid will be used to tie the SIM reference frame to the quasi-inertial reference frame defined by extragalactic objects and to remove any residual frame rotation with respect to the extragalactic frame. The current realization of the extragalactic frame is the International Celestial Reference Frame (ICRF). The ICRF is defined by the radio positions of 212 extragalactic objects and is the IAU sanctioned fundamental astronomical reference frame. This key project will advance our knowledge of the physics of the objects which will make up the SIM grid, such as quasars and chromospherically active stars, and relates directly to the stability of the SIM reference frame. The following questions concerning the physics of reference frame tie objects will be investigated.

Johnston, Kenneth J.↗