Search NASA⌕ Search

SEARCH · Search NASA

Results for “group testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Faint dwarfs in nearby groups

The number and distribution of dwarf satellite galaxies remain a critical test of cold dark matter-dominated structure formation on small scales. Until recently, observational information about galaxy formation on these scales has been limited mainly to the Local Group. We have searched for faint analogues of Local Group dwarfs around nearby bright galaxies, using a spatial clustering analysis of the photometric catalog of the Sloan Digital Sky Survey (SDSS) Data Release 8. Several other recent searches of SDSS have detected clustered satellite populations down to Δm{sub r} ≡ (m{sub r,} {sub sat} – m{sub r,} {sub main}) ∼ 6-8, using photometric redshifts to reduce background contamination. SDSS photometric redshifts are relatively imprecise, however, for faint and nearby galaxies. Instead, we use angular size to select potential nearby dwarfs and consider only the nearest isolated bright galaxies as primaries. As a result, we are able to detect an excess clustering signal from companions down to Δm{sub r} = 12, 4 mag fainter than most recent studies. We detect an overdensity of objects at separations <400 kpc, corresponding to about 4.6 ± 0.5 satellites per central galaxy, consistent with the satellite abundance expected from the Local Group, given our selection function. Although the sample of satellites detected is incomplete by construction, since it excludes the least and most compact dwarfs, this detection provides a lower bound on the average satellite luminosity function, down to luminosities corresponding to the faintest ''classical'' dwarfs of the Local Group.

79 ASTRONOMY AND ASTROPHYSICS↗

Role of IVC Filters in Endovenous Therapy for Deep Venous Thrombosis: The FILTER-PEVI (Filter Implantation to Lower Thromboembolic Risk in Percutaneous Endovenous Intervention) Trial

Objectives: The purpose of this study was to evaluate the necessity of and recommend indications for inferior vena cava (IVC) filter implantation during percutaneous endovenous intervention (PEVI) for deep venous thrombosis (DVT).BackgroundPEVI has emerged as a powerful tool in the management of acute proximal DVT. Instrumentation of extensive fresh thrombus is potentially associated with iatrogenic pulmonary embolism (PE). The true frequency of this complication has not been studied in a randomized fashion. We evaluated IVC filter implantation during PEVI for DVT. Methods: A total of 141 patients with symptomatic proximal DVT undergoing PEVI for symptomatic DVT were randomized to receive an IVC filter (70 patients) or no filter (71 patients; control group). The anticoagulation and PEVI regimen were similar between the two groups. Patients with development of symptoms suggestive of PE underwent objective testing for PE. Results: PE developed in 1 of the 14 symptomatic patients in the filter group and 8 of the 22 patients in the control group (P = 0.048). There was no mortality in any group. Three patients (4.2%) in the control group had transient hemodynamic instability necessitating resuscitory efforts. Predictors of iatrogenic PE were found to be PE at admission; involvement of two or more adjacent venous segments with acute thrombus; inflammatory form of DVT (severe erythema, edema, pain, and induration); and vein diameter of {>=}7 mm with preserved architecture. Conclusions: IVC filter implantation during PEVI reduces the risk of iatrogenic PE by eightfold without a mortality benefit. A selective approach may be exercised in filter implantation during PEVI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The characteristics of 78 related airfoil sections from tests in the variable-density wind tunnel

An investigation of a large group of related airfoils was made in the NACA variable-density wind tunnel at a large value of the Reynolds number. The tests were made to provide data that may be directly employed for a rational choice of the most suitable airfoil section for a given application. The variation of the aerodynamic characteristics with variations in thickness and mean-line form were systematically studied. (author)

Jacobs, Eastman N↗

Deletion of the EP402R Gene from the Genome of African Swine Fever Vaccine Strain ASFV-G-ΔI177L Provides the Potential Capability of Differentiating between Infected and Vaccinated Animals

The African swine fever virus (ASFV) mutant ASFV-G-ΔI177L is a safe and efficacious vaccine which induces protection against the challenge of its parental virus, the Georgia 2010 isolate. Although a genetic DIVA (differentiation between infected and vaccinated animals) assay has been developed for this vaccine, still there is not a serological DIVA test for differentiating between animals vaccinated with ASFV-G-ΔI177L and those infected with wild-type viruses. In this report, we describe the development of the ASFV-G-ΔI177L mutant having deleted the EP402R gene, which encodes for the viral protein responsible for mediating the hemadsorption of swine erythrocytes. The resulting virus, ASFV-G-ΔI177L/ΔEP402R, does not have a decreased ability to replicates in swine macrophages when compared with the parental ASFV-G-ΔI177L. Domestic pigs intramuscularly (IM) inoculated with either 10 2 or 10 6 HAD 50 of ASFV-G-ΔI177L/ΔEP402R remained clinically normal, when compared with a group of mock-vaccinated animals, indicating the absence of residual virulence. Interestingly, an infectious virus could not be detected in the blood samples of the ASFV-G-ΔI177L/ΔEP402R-inoculated animals in either group at any of the time points tested. Furthermore, while all of the mock-inoculated animals presented a quick and lethal clinical form of ASF after the intramuscular inoculation challenge with 10 2 HAD 50 of highly virulent parental field isolate Georgia 2010 (ASFV-G), all of the ASFV-G-ΔI177L/ΔEP402R-inoculated animals were protected, remaining clinically normal until the end of the observational period. Most of the ASFV-G-ΔI177L/ΔEP402R-inoculated pigs developed strong virus-specific antibody responses against viral antigens, reaching maximum levels at 28 days post inoculation. Importantly, all of the sera collected at that time point in the ASFV-G-ΔI177L/ΔEP402R-inoculated pigs did not react in a direct ELISA coated with the recombinant EP402R protein. Conversely, the EP402R protein was readily recognized by the pool of sera from the animals immunized with recombinant live attenuated vaccine candidates ASFV-G-ΔI177L, ASFV-G-ΔMGF, or ASFV-G-Δ9GL/ΔUK. Therefore, ASFV-G-ΔI177L/ΔEP402R is a novel, safe and efficacious candidate with potential to be used as an antigenically DIVA vaccine.

59 BASIC BIOLOGICAL SCIENCES↗

Special tests and destructive physical analyses as used by the Aerospace Corporation with nickel-hydrogen cells

The destructive physical analysis (DPA) of electrochemical devices is an important part of the overall test. Specific tests were developed to investigate the degradation mode or the failure mechanism that surfaces during the course of a cell being assembled, acceptance tested, and life-cycle tested. The tests that have been developed are peculiar to the cell chemistry under investigation. Tests are often developed by an individual or group of researchers as a result of their particular interest in an unresolved failure mechanism or degradation mode. A series of production, operational, and storage issues that were addressed by the Electrochemistry Group at The Aerospace Corporation are addressed. As a result of these investigations, as well as associated research studies carried out to develop a clearer understanding of the nickel oxyhydroxide electrode, a series of unique and useful specialized tests were developed. Some of these special tests were assembled to describe the methods that were found to be particularly useful in resolving a wide spectrum of manufacturing, operational, and storage issues related to nickel-hydrogen cells. The general methodology of these tests is given here with references listed to provide the reader with a more detailed understanding of the tests. The tests are classified according to the sequencing, starting with the impregnation of the nickel plaque material and culminating with the storage of completed cells. The details of the wet chemical procedures that were found to be useful because of their accuracy and reproducibility are given. The equations used to make the appropriate calculations are listed.

Zimmerman, A. H.↗

Double Cantilever Beam Fracture Toughness Testing of Several Composite Materials

Double-cantilever beam fracture toughness tests were performed by the Composite Materials Research Group on several different unidirectional composite materials provided by NASA Langley Research Center. The composite materials consisted of Hercules IM-7 carbon fiber and various matrix resin formulations. Multiple formulations of four different families of matrix resins were tested: LaRC - ITPI, LaRC - IA, RPT46T, and RP67/RP55. Report presents the materials tested and pertinent details supplied by NASA. For each material, three replicate specimens were tested. Multiple crack extensions were performed on each replicate.

Kessler, Jeff A.↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

Aims. The eROSITA Final Equatorial-Depth Survey (eFEDS), executed during the performance verification phase of the Spectrum-Roentgen-Gamma (SRG)/eROSITA telescope, was completed in November 2019. One of the science goals of this survey is to demonstrate the ability of eROSITA to detect samples of clusters and groups at the final depth of the eROSITA all-sky survey. Methods. Because of the sizeable (≈26" HEW FOV average) point-spread function of eROSITA, high-redshift clusters of galaxies or compact nearby groups hosting bright active galactic nuclei (AGN) can be misclassified as point sources by the source detection algorithms. A total of 346 galaxy clusters and groups in the redshift range of 0.1 < z < 1.3 were identified based on their red sequenc in the eFEDS point source catalog. Results. We examine the multiwavelength properties of these clusters and groups to understand the potential biases in our selection process and the completeness of the extent-selected sample. We find that the majority of the clusters and groups in the point source sample are indeed underluminous and compact compared to the extent-selected sample. Their faint X-ray emission, well below the flux limit of the extent-selected eFEDS clusters, and their compact X-ray emission are likely to be the main reason for this misclassification. In the sample, we confirm that 10% of the sources host AGN in their brightest cluster galaxies (BCGs) through optical spectroscopy and visual inspection. By studying their X-ray, optical, infrared, and radio properties, we establish a method for identifying clusters and groups that host AGN in their BCGs. We successfully test this method on the current point source catalog through the Sloan Digital Sky Survey optical spectroscopy and find eight low-mass clusters and groups with active radio-loud AGN that are particularly bright in the infrared. They include eFEDS J091437.8+024558, eFEDS J083520.1+012516, and eFEDS J092227.1+043339 at redshifts 0.3-0.4. Conclusions. This study helps us to characterize and understand our selection process and assess the completeness of the eROSITA extent-selected samples. The method we developed will be used to identify high-redshift clusters, AGN-dominated groups, and low-mass clusters that are misclassified in the future eROSITA all-sky survey point source catalogs.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation program for secondary spacecraft cells: Acceptance tests of Eagle-Picher 20.0 ampere-hour nickel-cadmium cells with auxiliary electrodes

A group of 29 cells with capacities ranging from 21.7 to 28.8 ampere-hours were tested. A summary of the results indicates: (1) All cells exceeded the rated capacity on all three capacity checks. (2) Five cells failed to recover to 1.150 volts. (3) During the overcharge tests, 15 of the 29 cells had to be removed from charge before completion of the respective tests due to high pressure.

Christy, D. E.↗

Preliminary evaluation of a micro-based repeated measures testing system

A need exists for an automated performance test system to study the effects of various treatments which are of interest to the aerospace medical community, i.e., the effects of drugs and environmental stress. The ethics and pragmatics of such assessment demand that repeated measures in small groups of subjects be the customary research paradigm. Test stability, reliability-efficiency and factor structure take on extreme significance; in a program of study by the U.S. Navy, 80 percent of 150 tests failed to meet minimum metric requirements. The best is being programmed on a portable microprocessor and administered along with tests in their original formats in order to examine their metric properties in the computerized mode. Twenty subjects have been tested over four replications on a 6.0 minute computerized battery (six tests) and which compared with five paper and pencil marker tests. All tests achieved stability within the four test sessions, reliability-efficiencies were high (r greater than .707 for three minutes testing), and the computerized tests were largely comparable to the paper and pencil version from which they were derived. This computerized performance test system is portable, inexpensive and rugged.

Kennedy, Robert S.↗

Nondestructive Testing Research and Capabilities at Pacific Northwest National Laboratory

Pacific Northwest National Laboratory (PNNL) is a United States Department of Energy (DOE) multipurpose laboratory operated by Battelle Memorial Institute. The laboratory maintains several technical and scientific capabilities to meet the diverse and challenging needs of sponsors. The Applied Physics Group maintains significant capabilities of interest to the nondestructive testing (NDT) community and regularly collaborates with other technical disciplines to form unique teams in response to specific challenges. This article provides a brief overview of the capabilities of the Applied Physics Group and highlights some activities to demonstrate the scope of capabilities that span from applied research aimed at improving existing NDT methods or processes to more fundamental research efforts that are focused on developing tools to facilitate future paradigms of structural condition monitoring and awareness.

Nondestructive Testing, NDE, Nuclear Power, Phased↗

Effects of defects in composite wind turbine blades – Part 1: Characterization and mechanical testing

Abstract. The Montana State University Composite Material Technologies Research Group performed a study to ascertain the effects of defects that often result from the manufacture of composite wind turbine blades. The first step in this multiyear study was to systematically quantify and enter these defects into a database before embedding similar defects into manufactured coupons. Through the Sandia National Laboratories Blade Reliability Collaborative (BRC), it was determined that key defects to investigate were fiber waves and porosity. An inspection of failed commercial-scale wind turbine blades yielded metrics that utilized specific parameters to physically characterize a defect. Methods to easily and consistently discretize, measure, and assess these defects based on the identified parameters were established to allow for statistical analysis. Data relating flaw parameters to frequencies of occurrence were analyzed and found to fit within standard distributions. Additionally, mechanical testing of coupons with flaws based on these physical characterization data was performed to understand effects of these defects. Representative blade materials and manufacturing methods were utilized and both material properties and damage progression were measured. It was observed that flaw parameters directly affected the mechanical response. While the data gathered in this first step are widely useful, it was also intended for use as a foundation for the rest of the study, to perform probabilistic analysis and comparative analysis of progressive damage models.

Nelson, Jared W. (ORCID:0000000207736091)↗

Reduction Reaction Activity on Pt-Monolayer-Shell PdIr/Ni-core Catalysts

Platinum monolayer oxygen reduction reaction catalysts present promising way of reducing the Pt content without scarifying its fuel cell performance. We present a facile way of preparing Pt monolayer shell PdIr-based core catalysts, which showed much higher activity for oxygen reduction reaction than that of TKK 46.6% Pt/C catalyst. Among tested samples, PtMLPd2Ir/Ni/C performs the best with Pt and Platinum Group Metal mass activity around 9 and 0.25 times higher of that of TKK 46.6% Pt/C. In addition, accelerated aging test indicates its excellent durability.

30 DIRECT ENERGY CONVERSION↗

The Effect of Aging on the Delamination Fracture Energy of Glass Solar Reflectors

Thin metal and metal oxide films deposited on glass or polymer substrates have been widely applied to manufacture front surfaced solar reflectors such as those used in the concentrated solar power (CSP) systems due to the facts that they are highly transparent, resistant to ultraviolet (UV) light and abrasion, and chemically inert. However, the reliable operation over long periods of outdoor exposure of such solar reflectors depends on the adequate adhesion between each layer to prevent delamination and subsequent failure. We report results from measurements of the delamination fracture energy (DFE) of the weakest interface in both as-deposited and aged reflectors, where the reflector construction consists of a glass/copper/silver/oxide stack. In this study, DFE was measured using a width-tapered beam method and the test results showed that the weakest interface of this solar reflector is the copper-glass interface, with a delamination fracture energy of approximately 4.4 J/m 2 . In order to verify the test results, finite element (FE) simulations were run using the commercial software package ABAQUS 6.14 based on the cohesive zone model (CZM). In the simulations, the DFE derived from the delamination measurement was treated as an input and the delamination forces from the FE simulations were compared to the experimental results. The good agreement between the tested and simulated delamination force indicated that this width-tapered beam method is accurate even for very small DFE, making it appropriate to test the DFE of front surfaced glass solar reflectors. Additionally, in order to study the aging effect on the DFE, accelerated aging tests were conducted using samples with different protective coatings, one group of samples with alumina ( Al 2 O 3 ) protective coating and the other group with titania ( TiO 2 ) protective coating. The DFE after 50 and 100 hours of accelerated aging were measured. The test results showed that the copper-glass interface would still be the weakest interface for all samples after aging, and the DFE for samples with Al 2 O 3 protective coating was unchanged whereas the copper-glass interface was found to undergo statistically significant change after both 50 and 100 hours of aging for samples with TiO 2 protective coating. We found that DFE at the copper/glass interface decreased after 50 hours of aging then increased after 100 hours of aging. The origin of this non-monotonic response of TiO 2 coated reflectors under accelerated aging conditions is unknown.

36 MATERIALS SCIENCE↗

Benzyl-Functionalized Room Temperature Ionic Liquids for CO2/N2 Separation

In this work, three classes of room temperature ionic liquids (RTILs), including imidazolium, pyridinium, and pyrrolidinium ionic liquids with a benzyl group appended to the cation, were synthesized and tested for their performance in separating CO{sub 2} and N{sub 2}. All RTILs contained the bis(trifluoromethylsulfonyl)imide anion, permitting us to distinguish the impact of the benzyl moiety attached to the cation on gas separation performance. In general, the attachment of the benzyl group increased the viscosity of the ionic liquid compared with the unfunctionalized analogs and decreased the CO{sub 2} permeability. However, all of the benzyl-modified ionic liquids exhibited enhanced CO{sub 2}/N{sub 2} selectivities compared with alkyl-based ionic liquids, with values ranging from 22.0 to 33.1. In addition, CO{sub 2} solubilities in the form of Henry's constants were also measured and compared with unfunctionalized analogs. Results of the membrane performance tests and CO{sub 2} solubility measurements demonstrate that the benzyl-functionalized RTILs have significant potential for use in the separation of carbon dioxide from combustion products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fractal analysis for assessing the level of modulation of IMRT fields

Purpose: To investigate the potential of three fractal dimension (FD) analysis methods (i.e., the variation, power spectrum, and variogram methods) as metrics for quantifying the degree of modulation in planned intensity modulated radiation therapy (IMRT) treatment fields, and compare the most suitable FD method to the number of monitor units (MUs), the average leaf gap, and the 2D modulation index (2D MI) for assessing modulation. Methods: The authors implemented, validated, and compared the variation, power spectrum, and variogram methods for computing the FD. Validation of the methods was done using mathematical fractional Brownian surfaces of known FD that ranged in size from 128 x 128 to 512 x 512. The authors used a test set consisting of seven head and neck carcinoma plans (50 prescribed treatment fields) to choose an FD cut-point that ensures no false positives (100% specificity) in distinguishing between moderate and high degrees of field modulation. The degree of field modulation was controlled by adjusting the fluence smoothing parameters in the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). The moderate modulation fields were representative of the degree of modulation used clinically at the authors' institution. The authors performed IMRT quality assurance (QA) on the 50 test fields using the MapCHECK device. The FD cut-point was applied to a validation set consisting of four head and neck plans (28 fields). The area under the curve (AUC) from receiver operating characteristic (ROC) analysis was used to compare the ability of FD, number of MUs, average leaf gap, and the 2D MI for distinguishing between the moderate and high modulation fields. Results: The authors found the variogram FD method to be the most suitable for assessing the modulation complexity of IMRT fields for head and neck carcinomas. Pass rates as measured by the gamma criterion for the MapCHECK IMRT field measurements were higher for the moderately modulated fields, and a gamma criterion with 1 mm distance-to-agreement and 1% dose difference showed a clear separation between the 94% pass rates of the moderate and high modulation groups. From the ROC analysis of the test set, the authors found the AUC of the variogram FD, number of MUs, average leaf gap, and 2D MI methods to be 0.99 (almost perfect), 0.91 (excellent), 0.91 (excellent), and 0.92 (excellent), respectively. A cut-point of FD > 2.25 correctly identified 92.8% of the high modulation fields and 100% of the moderately modulated fields in the validation set, satisfying the condition of no false positives. Conclusions: Of the three FD methods investigated, the variogram method is the most accurate and precise metric for identifying high modulation treatment fields. It is also more accurate and precise than the number of MUs, the average leaf gap, and the 2D MI. Although MapCHECK IMRT QA does a reasonable job at identifying high modulation fields, the variogram FD method provides one with the opportunity to quantitatively and accurately assess modulation and adjust overly modulated fields at the treatment planning stage before they are sent to the treatment machine for QA or patient treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

IMRT commissioning: Multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119

AAPM Task Group 119 has produced quantitative confidence limits as baseline expectation values for IMRT commissioning. A set of test cases was developed to assess the overall accuracy of planning and delivery of IMRT treatments. Each test uses contours of targets and avoidance structures drawn within rectangular phantoms. These tests were planned, delivered, measured, and analyzed by nine facilities using a variety of IMRT planning and delivery systems. Each facility had passed the Radiological Physics Center credentialing tests for IMRT. The agreement between the planned and measured doses was determined using ion chamber dosimetry in high and low dose regions, film dosimetry on coronal planes in the phantom with all fields delivered, and planar dosimetry for each field measured perpendicular to the central axis. The planar dose distributions were assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop confidence limits for the test results using the concept confidence limit=|mean|+1.96{sigma}. Other facilities can use the test protocol and results as a basis for comparison to this group. Locally derived confidence limits that substantially exceed these baseline values may indicate the need for improved IMRT commissioning.

61 RADIATION PROTECTION AND DOSIMETRY↗

GALAXIES IN X-RAY GROUPS. I. ROBUST MEMBERSHIP ASSIGNMENT AND THE IMPACT OF GROUP ENVIRONMENTS ON QUENCHING

Understanding the mechanisms that lead dense environments to host galaxies with redder colors, more spheroidal morphologies, and lower star formation rates than field populations remains an important problem. As most candidate processes ultimately depend on host halo mass, accurate characterizations of the local environment, ideally tied to halo mass estimates and spanning a range in halo mass and redshift, are needed. In this work, we present and test a rigorous, probabilistic method for assigning galaxies to groups based on precise photometric redshifts and X-ray-selected groups drawn from the COSMOS field. The groups have masses in the range 10{sup 13} {approx}< M{sub 200c}/M{sub Sun} {approx}< 10{sup 14} and span redshifts 0 < z < 1. We characterize our selection algorithm via tests on spectroscopic subsamples, including new data obtained at the Very Large Telescope, and by applying our method to detailed mock catalogs. We find that our group member galaxy sample has a purity of 84% and completeness of 92% within 0.5 R{sub 200c}. We measure the impact of uncertainties in redshifts and group centering on the quality of the member selection with simulations based on current data as well as future imaging and spectroscopic surveys. As a first application of our new group member catalog which will be made publicly available, we show that member galaxies exhibit a higher quenched fraction compared to the field at fixed stellar mass out to z {approx} 1, indicating a significant relationship between star formation and environment at group scales. We also address the suggestion that dusty star-forming galaxies in such groups may impact the high-l power spectrum of the cosmic microwave background and find that such a population cannot explain the low power seen in recent Sunyaev-Zel'dovich measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

A DISTINCT PEAK-FLUX DISTRIBUTION OF THE THIRD CLASS OF GAMMA-RAY BURSTS: A POSSIBLE SIGNATURE OF X-RAY FLASHES?

Gamma-ray bursts (GRBs) are the most luminous events in the universe. Going beyond the short-long classification scheme, we work in the context of three burst populations with the third group of intermediate duration and softest spectrum. We are looking for physical properties which discriminate the intermediate duration bursts from the other two classes. We use maximum likelihood fits to establish group memberships in the duration-hardness plane. To confirm these results we also use k-means and hierarchical clustering. We use Monte Carlo simulations to test the significance of the existence of the intermediate group and we find it with 99.8% probability. The intermediate duration population has a significantly lower peak flux (with 99.94% significance). Also, long bursts with measured redshift have higher peak fluxes (with 98.6% significance) than long bursts without measured redshifts. As the third group is the softest, we argue that we have related them with X-ray flashes among the GRBs. We give a new, probabilistic definition for this class of events.

79 ASTRONOMY AND ASTROPHYSICS↗