Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Charge Separation for Muon Collider Cooling

Most schemes for six dimensional muon ionization cooling work for only one sign. It is then necessary to have charge separation prior to that cooling. Schemes of charge separation using bent solenoids are described, and their simulated performances reported. It is found that for efficient separation, it should take place at somewhat higher momenta than commonly used for the cooling. Charge separation using bent solenoids can be effective if carefully designed. Bent solenoids can generate dispersion from 'momentum drift', but can spoil emittance from 'amplitude drift'. Abrupt entry into a bent solenoid causes emittance growth, but matching using integral {lambda} lengths, or Norem's method, corrects this problem. Reverse bending removes the dispersion and reduces 'amplitude drift', but only if there is no rf until after all bending. The main problem is bunch lengthening and distortion from the long transports without rf. At 230 MeV/c, even with a higher field of 3 T, non-linearities increase the 6D emittance by 117% and give 13% loss, which is not acceptable. Raising the momentum from 230 to 300 MeV gives a 6D emittance growth of 38% and the loss 5%, which may be acceptable. Raising the momentum further to 400 MeV/c gives very good results: 6D growth of 24% and 2.5% loss. Further optimization should include the acceleration to the higher momenta prior to the separation, and the higher momentum cooling immediately after it. The longitudinal phase space prior to the separation should be rotated to minimize the total bunch lengthening.

43 PARTICLE ACCELERATORS↗

Phonon emission in germanium and silicon by electrons and holes in applied electric field at low temperature

The cryogenic dark matter search employs Ge and Si detectors to search for weakly interacting massive particle dark matter via its elastic-scattering interactions with nuclei while discriminating against interactions of background particles. These detectors distinguish nuclear recoils from electron recoils by simultaneously measuring phonon and ionization production in semiconducting substrates at sub-kelvin temperatures. They also reconstruct event position by quadrant-segmented measurement of the phonon signal. The ionization drift field does work on the electrons and holes. The charge carriers radiate this energy as acoustic phonons. At the typical applied field of 300 V/m in Ge (400 V/m in Si), we self-consistently model the behavior of the electrons and holes using independent drifted Maxwellian distributions, each characterized by an average drift velocity and an effective temperature, and including acoustic phonon emission. We calculate the phonon power angular and frequency distributions. We find that the bias polarity affects these distributions and, therefore, the phonon collection efficiency in Ge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Studies of Ion Beam Neutralization: Preliminary Results

A testing platform is designed to study ion beam neutralization in the mesothermal, collisionless region. In the experimental setup, argon neutrals were ionized in a microwave cavity and accelerated by a plasma lens system which was biased to 2500 V above the system ground. Electrons were boiled off from two hot tungsten filaments to neutralize the ion beam. The plasma is diagnosed using Langmuir probe and Faraday probe. A 3-D traversing system and a complete data acquisition loop were developed to efficiently measure 3-D beam profile. Preliminary measurements of beam profiles are presented for different operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Unifying the Micro and Macro Properties of AGN Feeding and Feedback

We unify the feeding and feedback of supermassive black holes with the global properties of galaxies, groups, and clusters by linking for the first time the physical mechanical efficiency at the horizon and megaparsec scale. The macro hot halo is tightly constrained by the absence of overheating and overcooling as probed by X-ray data and hydrodynamic simulations (ε{sub BH}≃10{sup −3} T{sub x,7.4}). The micro flow is shaped by general-relativistic effects tracked by state-of-the-art GR-RMHD simulations (ε{sub ∙}≃0.03). The supermassive black hole properties are tied to the X-ray halo temperature T{sub x}, or related cosmic scaling relation (as L{sub x}). The model is minimally based on first principles, such as conservation of energy and mass recycling. The inflow occurs via chaotic cold accretion (CCA), the rain of cold clouds condensing out of the quenched cooling flow and then recurrently funneled via inelastic collisions. Within 100s gravitational radii, the accretion energy is transformed into ultrafast 10{sup 4} km s{sup −1} outflows (UFOs) ejecting most of the inflowing mass. At larger radii, the energy-driven outflow entrains progressively more mass: at roughly kiloparsec scale, the velocities of the hot/warm/cold outflows are a few 10{sup 3}, 1000, and 500 km s{sup −1}, with median mass rates ∼ 10, 100, and several 100 M{sub ⊙} yr{sup −1}, respectively. The unified CCA model is consistent with the observations of nuclear UFOs and ionized, neutral, and molecular macro outflows. We provide step-by-step implementation for subgrid simulations, (semi)analytic works, or observational interpretations that require self-regulated AGN feedback at coarse scales, avoiding the a-posteriori fine-tuning of efficiencies.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-552: A One-Year Evaluation of the QABeamChecker+ for Use with the CyberKnife System

Purpose: By attaching an adapter plate with fiducial markers to the QA BeamChecker+ (Standard Imaging, Inc., Middleton, WI), the output of the CyberKnife can be accurately, efficiently, and consistently evaluated. The adapter plate, known as the Cutting Board, allows for automated alignment of the QABC+ using the CK’s stereoscopic kV image-based treatment localization system (TLS). Described herein is an evaluation of the system following a year of clinical utilization. Methods: Based on a CT scan of the QABC+ and CB, a treatment plan is generated which delivers a beam to each of the 5 plane-parallel ionization chambers. Following absolute calibration of the CK, the QA plan is delivered, and baseline measurements are acquired (and automatically corrected for temperature and pressure). This test was performed at the beginning of each treatment day for a year. A calibration evaluation (using a water-equivalent slab and short thimble chamber) is performed every four weeks, or whenever the QABC+ detects a deviation of more than 1.0%. Results: During baseline evaluation, repeat measurements (n=10) were performed, with an average output of 0.25% with an SD of 0.11%. As a test of the reposition of the QABC+ and CB, ten additional measurements were performed where between each acquisition, the entire system was removed and re-positioned using the TLS. The average output deviation was 0.30% with a SD of 0.13%. During the course of the year, 187 QABC+ measurements and 13 slab-based measurements were performed. The output measurements of the QABC+ correlated well with slab-based measurements (R2=0.909). Conclusion: By using the QABC+ and CB, daily output was evaluated accurately, efficiently, and consistently. From setup to break-down (including analysis), this test required 5 minutes instead of approximately 15 using traditional techniques (collimator-mounted ionization chambers). Additionally, by automatically saving resultant output deviation to a database, trend analysis was simplified. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

60 APPLIED LIFE SCIENCES↗

Collider-quality electron bunches from an all-optical plasma photoinjector

We present an approach for generating collider-quality electron bunches using a plasma photoinjector. The approach leverages recently developed techniques for the spatiotemporal control of laser pulses to produce a moving ionization front in a nonlinear plasma wave. The moving ionization front generates an electron bunch with a current profile that balances the longitudinal electric field of an electron beam-driven plasma wave, creating a uniform accelerating field across the bunch. Particle-in-cell (PIC) simulations of the ionization stage show the formation of an electron bunch with 220 pC charge and low emittance (ɛ 𝑥 = 171 nm rad, ɛ 𝑦 = 76 nm rad). Quasistatic PIC simulations of the acceleration stage show that the bunch is efficiently accelerated to 24 GeV over 2 m with a final energy spread of less than 1% and emittances of ɛ 𝑥 = 189 nm rad and ɛ 𝑦 = 80 nm rad. This high-quality electron bunch meets the requirements outlined by the Snowmass process for intermediate-energy colliders and compares favorably to the beam quality of proposed and existing accelerator facilities. The results establish the feasibility of plasma photoinjectors for future collider applications making a significant step toward the realization of high-luminosity, compact accelerators for particle physics research.

43 PARTICLE ACCELERATORS↗

DETERMINATION OF NON-THERMAL VELOCITY DISTRIBUTIONS FROM SERTS LINEWIDTH OBSERVATIONS

Non-thermal velocities obtained from the measurement of coronal Extreme Ultraviolet (EUV) linewidths have been consistently observed in solar EUV spectral observations and have been theorized to result from many plausible scenarios including wave motions, turbulence, or magnetic reconnection. Constraining these velocities can provide a physical limit for the available energy resulting from unresolved motions in the corona. We statistically determine a series of non-thermal velocity distributions from linewidth measurements of 390 emission lines from a wide array of elements and ionization states observed during the Solar Extreme Ultraviolet Research Telescope and Spectrograph 1991-1997 flights covering the spectral range 174-418 A and a temperature range from 80,000 K to 12.6 MK. This sample includes 248 lines from active regions, 101 lines from quiet-Sun regions, and 41 lines were observed from plasma off the solar limb. We find a strongly peaked distribution corresponding to a non-thermal velocity of 19-22 km s{sup -1} in all three of the quiet-Sun, active region, and off-limb distributions. For the possibility of Alfven wave resonance heating, we find that velocities in the core of these distributions do not provide sufficient energy, given typical densities and magnetic field strengths for the coronal plasma, to overcome the estimated coronal energy losses required to maintain the corona at the typical temperatures working as the sole mechanism. We find that at perfect efficiency 50%-60% of the needed energy flux can be produced from the non-thermal velocities measured.

79 ASTRONOMY AND ASTROPHYSICS↗

Convoluted effect of laser fluence and pulse duration on the property of a nanosecond laser-induced plasma into an argon ambient gas at the atmospheric pressure

We studied the behavior of the plasma induced by a nanosecond infrared (1064 nm) laser pulse on a metallic target (Al) during its propagation into argon ambient gas at the atmospheric pressure and especially over the delay interval ranging from several hundred nanoseconds to several microseconds. In such interval, the plasma is particularly interesting as a spectroscopic emission source for laser-induced plasma spectroscopy (LIBS). We show a convoluted effect between laser fluence and pulse duration on the structure and the emission property of the plasma. With a relatively high fluence of about 160 J/cm{sup 2} where a strong plasma shielding effect is observed, a short pulse of about 4 ns duration is shown to be significantly more efficient to excite the optical emission from the ablation vapor than a long pulse of about 25 ns duration. While with a lower fluence of about 65 J/cm{sup 2}, a significantly more efficient excitation is observed with the long pulse. We interpret our observations by considering the post-ablation interaction between the generated plume and the tailing part of the laser pulse. We demonstrate that the ionization of the layer of ambient gas surrounding the ablation vapor plays an important role in plasma shielding. Such ionization is the consequence of laser-supported absorption wave and directly dependent on the laser fluence and the pulse duration. Further observations of the structure of the generated plume in its early stage of expansion support our explanations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Relativistic core–valence-separated equation-of-motion coupled-cluster singles and doubles method: Efficient implementation and benchmark calculations

An efficient implementation for the relativistic exact two-component core–valence-separated equation-of-motion coupled-cluster singles and doubles (X2C-CVS-EOM-CCSD) method is reported. The explicit exclusion of pure valence excitations in the EOM-CCSD excited-state eigenvalue equations significantly improves the efficiency for calculations of core-excited states. Benchmark relativistic CVS-EOM-CC calculations with systematic inclusion of relativistic, correlation, and basis-set effects are shown to provide highly accurate results for core ionized and excited states involving heavy atoms.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cesium Removal from Surrogate Pyroprocessing Salt by Electrodeposition

Active metals in used nuclear fuel dissolve into the salt during pyroprocessing and are not removed by electrorefining or drawdown operations. The buildup of 137 Cs over time increases the heat load and ionizing radiation level of the salt such that it must be replaced frequently, resulting in a significant amount of salt waste. An effective means of managing cesium in the molten salt electrolyte would increase the efficiency of pyroprocessing and decrease the volume of salt waste requiring disposal. A previous report summarized issues that must be addressed when developing a removal strategy and assessed the suitability of existing methods and remaining technological gaps to their application (Rose and Thomas 2023). Cesium is extremely stable in molten salt as a chloride—even more stable than the LiCl-KCl eutectic base salt used for pyroprocessing fuel—which makes removing cesium a challenge. However, sufficiently strong atomic interactions occur between active metal species and liquid metals that make the electrodeposition of active metal fission products into liquid metal electrodes energetically favorable. The feasibility of recovering cesium from LiCl-KCl pyroprocessing salt through electrodeposition into liquid metals is eing assessed by identifying potentially effective liquid metals and performing tests to determine the effectiveness of electrodepositing cesium from a LiCl/KCl salt into these liquid metals. Previous studies investigating the electrodeposition of Sr 2+ , and Ba 2+ into zinc, cadmium, bismuth, lead, tin and antimony have shown that alkali and alkaline earth metals can be electrodeposited at liquid metal cathodes (Kim et al., 2018). The removal of Ba 2+ and Sr 2+ was measured to be more efficient than the removal of monovalent cations due to the greater thermochemical driving force for alloying those elements with the liquid metal (Jang et al. 2022). Because the equilibrium potentials are dependent on the interactions of the active metal in the liquid metal, it is likely that the other alkali metals Li + , and K + , will deposit from LiCl/KCl salt with the Cs + . Therefore, application of this method to recover active metals from pyroprocessing salt will benefit from the use of a liquid metal and set of operating conditions that sufficiently increase the reduction potential of cesium to remove cesium from the waste salt with an acceptable amount of co-deposited lithium and potassium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Self-Consistent Relativistic Electron Scattering using the Sherlock Scattering Model for X-ray Diagnostics

We present on a new, self-consistent, arbitrary-temperature Romberg integration scheme for modeling electron scattering in materials in a LANL Lagrangian Shock Hydro (LSH) code. Electron beam-target interactions are fundamental to a wide range of scientific and technological applications. When high-energy electron beams hit their target, they may scatter, deposit energy, or ionize the source. These processes govern the behavior and outcomes in nanotechnology manufacturing, electron microscopy, and modern X-ray diagnostics. Simulating these interactions is essential for interpreting experimental results, predicting material responses, and designing efficient tools and experiments. At Los Alamos, this is done using a LSH code, which is a multi-dimension, multi-material, massively parallel, multi-physics code used to simulate applications from asteroid impacts to electron beam interactions. By effectively and efficiently modeling the way that electrons scatter from the beam we can bolster these simulations and more accurately predict experimental outcomes. The model currently implemented in the LSH of interest is based on work by Papp and does not self-consistently preserve momentum in the slightly relativistic regime; here we adopt a model proposed by Braams and Karney and implement a Romberg integration scheme to compute the diffusion tensor. In this paper we will provide background on the Braams-Karney diffusion tensor as well as the Romberg integration scheme we employed to numerically solve for it. We will show that our integration scheme is accurate in solving for the set of scalar potentials used to re-express the diffusion tensor in differential form, and in solving for the diffusion coefficients in the larger LSH code. By using this diffusion tensor rather than the existing Papp one, and numerically integrating it with a Romberg method, we produce much more accurate, self-consistent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Camera Imaging of Hall Thruster Ignition

Hall thrusters provide efficient space propulsion by electrostatic acceleration of ions. Rotating electron clouds in the thruster overcome the space charge limitations of other methods. Images of the thruster startup, taken with a fast camera, reveal a bright ionization period which settles into steady state operation over 50 μs. The cathode introduces azimuthal asymmetry, which persists for about 30 μs into the ignition. Plasma thrusters are used on satellites for repositioning, orbit correction and drag compensation. The advantage of plasma thrusters over conventional chemical thrusters is that the exhaust energies are not limited by chemical energy to about an electron volt. For xenon Hall thrusters, the ion exhaust velocity can be 15-20 km/s, compared to 5 km/s for a typical chemical thruster

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Charge collection efficiency degradation induced by MeV ions in semiconductor devices: Model and experiment

This study investigates both theoretically and experimentally the charge collection efficiency (CCE) degradation in silicon diodes induced by energetic ions. Ion Beam Induced Charge (IBIC) measurements carried out on n- and p-type silicon diodes which were previously irradiated with MeV He ions show evidence that the CCE degradation does not only depend on the mass, energy and fluence of the damaging ion, but also depends on the ion probe species and on the polarization state of the device. A general one-dimensional model is derived, which accounts for the ion-induced defect distribution, the ionization profile of the probing ion and the charge induction mechanism. Using the ionizing and non-ionizing energy loss profiles resulting from simulations based on the binary collision approximation and on the electrostatic/transport parameters of the diode under study as input, the model is able to accurately reproduce the experimental CCE degradation curves without introducing any phenomenological additional term or formula. Although limited to low level of damage, the model is quite general, including the displacement damage approach as a special case and can be applied to any semiconductor device. It provides a method to measure the capture coefficients of the radiation induced recombination centres. They can be considered indexes, which can contribute to assessing the relative radiation hardness of semiconductor materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EVOLUTION OF BLISTER-TYPE H II REGIONS IN A MAGNETIZED MEDIUM

We use the three-dimensional Athena ionizing radiation-magnetohydrodynamics code to simulate blister-type H II regions driven by stars on the edge of magnetized gas clouds. We compare these to simulations of spherical H II regions where the star is embedded deep within a cloud, and to non-magnetized simulations of both types, in order to compare their ability to drive turbulence and influence star formation. We find that magnetized blister H II regions can be very efficient at injecting energy into clouds. This is partly a magnetic effect: the magnetic energy added to a cloud by an H II region is comparable to or larger than the kinetic energy, and magnetic fields can also help collimate the ejected gas, increasing its energy yield. As a result of these effects, a blister H II region expanding into a cloud with a magnetic field perpendicular to its edge injects twice as much energy by 5 Myr as a non-magnetized blister H II region driven by a star of the same luminosity. Blister H II regions are also more efficient at injecting kinetic energy than spherical H II regions, due to the recoil provided by escaping gas, but not as much as predicted by some analytic approximations.

79 ASTRONOMY AND ASTROPHYSICS↗

CONFIRMATION OF AND VARIABLE ENERGY INJECTION BY A NEAR-RELATIVISTIC OUTFLOW IN APM 08279+5255

We present results from multi-epoch spectral analysis of XMM-Newton and Chandra observations of the broad absorption line (BAL) quasar APM 08279+5255. Our analysis shows significant X-ray BALs in all epochs with rest-frame energies lying in the range of approx6.7-18 keV. The X-ray BALs and 0.2-10 keV continuum show significant variability on timescales as short as 3.3 days (proper time) implying a source size-scale of approx10 r{sub g}, where r{sub g} is the gravitational radius. We find a large gradient in the outflow velocity of the X-ray absorbers with projected outflow velocities of up to 0.76c. The maximum outflow velocity constrains the angle between the wind velocity and our line of sight to be less than approx22 deg. Based on our spectral analysis, we identify the following components of the outflow: (1) highly ionized X-ray absorbing material with an ionization parameter in the range of 2.9 approx< log xi approx< 3.9 (the units of xi are erg cm s{sup -1}) and a column density of log N {sub H} approx 23 (the units of N {sub H} are cm{sup -2}) outflowing at velocities of up to 0.76c; and (2) low-ionization X-ray absorbing gas with log N{sub H} approx 22.8. We find a possible trend between the X-ray photon index and the maximum outflow velocity of the ionized absorber in the sense that flatter spectra appear to result in lower outflow velocities. Based on our spectral analysis of observations of APM 08279+5255 over a period of 1.2 yr (proper time), we estimate the mass-outflow rate and efficiency of the outflow to have varied between 16{sup +12}{sub -8} M{sub sun} yr{sup -1} to 64{sup +66}{sub -40} M{sub sun} yr{sup -1} and 0.18{sup +0.15}{sub -0.11} to 1.7{sup +1.9}{sub -1.2}, respectively. Assuming that the outflow properties of APM 08279+5255 are a common property of most quasars at similar redshifts, our results then imply that quasar winds are massive and energetic enough to significantly influence the formation of the host galaxy, provide significant metal enrichment to the interstellar medium and intergalactic medium, and are a viable mechanism for feedback at redshifts near the peak in the number density of galaxy mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionization and fragmentation of polycyclic aromatic hydrocarbon clusters in collisions with keV ions

We report on an experimental study of the ionization and fragmentation of clusters of k polycyclic aromatic hydrocarbon (PAH) molecules using anthracene, C{sub 14}H{sub 10}, or coronene, C{sub 24}H{sub 12}. These PAH clusters are moderately charged and strongly heated in small impact parameter collisions with 22.5-keV He{sup 2+} ions, after which they mostly decay in long monomer evaporation sequences with singly charged and comparatively cold monomers as dominating end products. We describe a simple cluster evaporation model and estimate the number of PAH molecules in the clusters that have to be hit by He{sup 2+} projectiles for such complete cluster evaporations to occur. Highly charged and initially cold clusters are efficiently formed in collisions with 360-keV Xe{sup 20+} ions, leading to cluster Coulomb explosions and several hot charged fragments, which again predominantly yield singly charged, but much hotter, monomer ions than the He{sup 2+} collisions. We present a simple formula, based on density-functional-theory calculations, for the ionization energy sequences as functions of coronene cluster size, rationalized in terms of the classic electrostatic expression for the ionization of a charged conducting object. Our analysis indicates that multiple electron removal by highly charged ions from a cluster of PAH molecules rapidly may become more important than single ionization as the cluster size k increases and that this is the main reason for the unexpectedly strong heating in these types of collisions.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic control of breakdown: Toward energy-efficient hollow-cathode magnetron discharges

Characteristics of electrical breakdown of a planar magnetron enhanced with an electromagnet and a hollow-cathode structure, are studied experimentally and numerically. At lower pressures the breakdown voltage shows a dependence on the applied magnetic field, and the voltage necessary to achieve the self-sustained discharge regime can be significantly reduced. At higher pressures, the dependence is less sensitive to the magnetic field magnitude and shows a tendency of increased breakdown voltage at the stronger magnetic fields. A model of the magnetron discharge breakdown is developed with the background gas pressure and the magnetic field used as parameters. The model describes the motion of electrons, which gain energy by passing the electric field across the magnetic field and undergo collisions with neutrals, thus generating new bulk electrons. The electrons are in turn accelerated in the electric field and effectively ionize a sufficient amount of neutrals to enable the discharge self-sustainment regime. The model is based on the assumption about the combined classical and near-wall mechanisms of electron conductivity across the magnetic field, and is consistent with the experimental results. The obtained results represent a significant advance toward energy-efficient multipurpose magnetron discharges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗