Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser interferometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Thermo-Mechanical Shock, X-Ray Transport and Radiation Response Analysis Experiments on NIF

The study of x-ray induced rapid heating and the resulting material responses - (thermomechanical shock (TMS) and thermo-structural response (TSR)) - is important to our understanding of material behavior in extreme environments. A series of high conversion efficiency (XRCE) x-ray sources have been developed for the NIF laser facility ranging in fluence and spectral content. In conjunction with source development, we have developed a new XTRRA (X-ray Transport and Radiation Response Analysis) test cassette to hold a set of samples, each at equal distance from target chamber center (TCC) where the x-ray source is placed. Design and performance details of the x-ray sources is discussed elsewhere. Here, we describe the development and use of this TMS XTRRA test cassette. The XTRRA test cassette is a snout mounted on a NIF Diagnostic Instrument Manipulator (DIM) designed to position six samples equidistant from the x-ray source to assure uniform irradiation of all samples. Photon Displacement interferometry (PDI) is used to measure the displacement of the rear surface of each sample resulting from x-ray exposure on the front of the sample. This will help determine the x-ray generated impulse on the sample. The samples are retrieved from the snout after the shot for inspection and post-shot analysis including the measurement of sample ablated mass and engineering tests examining changes in the material structure. The data from experiments are compared to predictions from LLNL’s ASC codes and used to inform models implemented in these codes. Thus, XRCE x-ray sources with the XTRRA snout at the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory provide the ability to expose a broad range of material samples directly to high x-ray fluence, measure shock transits, and recover the sample for further analysis post-shot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A combination interferometric and morphological image processing approach to rapid quality assessment of additively manufactured cellular truss core components

Advanced manufacturing (AM) processes such as laser powder bed fusion (LPBF) are increasingly capable of fabricating components with useful and unprecedented mechanical properties by incorporating complex internal bracing structures. From the standpoint of quality control and assessment, however, internally complex assemblies present significant build-verification challenges. Here we propose a hybrid approach to the inspection involving the application of computer-aided speckle interferometry (CASI) and morphological image processing as a rapid, inexpensive, and facile method for AM quality control. The described methodology has low capital equipment costs, is full-field and non-contact, can be used in an industrial setting, and has very low requirements in terms of operator training and expertise. Consisting primarily of the combination of image processing software with a simple optical system of variable sensitivity, the method is shown to be effective for inspection of a titanium honeycomb component subjected to differential pressure. Results are compared to those achieved with computed tomography (CT), immersion ultrasound testing (UT), and optical holographic interferometry. Here we propose several possible processing strategies for automated quality assessment based on this powerful hybrid approach.

36 MATERIALS SCIENCE↗

Collinear Three-Photon Excitation of a Strongly Forbidden Optical Clock Transition

The 1 𝑆 0 − 3 𝑃 0 clock transition in strontium serves as the foundation for the world’s best atomic clocks and for gravitational wave detector concepts in clock atom interferometry. This transition is weakly allowed in the fermionic isotope 87 Sr but strongly forbidden in bosonic isotopes. Here, we demonstrate coherent excitation of the clock transition in bosonic 88 Sr using a novel collinear three-photon process in a weak magnetic field. We observe Rabi oscillations with frequencies of up to 50 kHz using W/cm 2 laser intensities and Gauss-level magnetic field amplitudes. The absence of nuclear spin in bosonic isotopes offers decreased sensitivity to magnetic fields and optical lattice light shifts, enabling atomic clocks with reduced systematic errors. The collinear propagation of the laser fields permits the interrogation of spatially separated atomic ensembles with common laser pulses, a key requirement for dark matter searches and gravitational wave detection with next-generation quantum sensors.

74 ATOMIC AND MOLECULAR PHYSICS↗

Digitally Enhanced Heterodyne Interferometry

Spurious interference limits the performance of many interferometric measurements. Digitally enhanced interferometry (DEI) improves measurement sensitivity by augmenting conventional heterodyne interferometry with pseudo-random noise (PRN) code phase modulation. DEI effectively changes the measurement problem from one of hardware (optics, electronics), which may deteriorate over time, to one of software (modulation, digital signal processing), which does not. DEI isolates interferometric signals based on their delay. Interferometric signals are effectively time-tagged by phase-modulating the laser source with a PRN code. DEI improves measurement sensitivity by exploiting the autocorrelation properties of the PRN to isolate only the signal of interest and reject spurious interference. The properties of the PRN code determine the degree of isolation.

Shaddock, Daniel↗

Orbiting Stellar Interferometer: An Overview

The Orbiting Stellar Interferometer (OSI) is a concept for a first-generation space interferometer with astrometric and imaging capabilities and is responsive to the recommendations of the Astronomy and Astrophysics Survey Committee for an astrometric interferometry mission. OSI is a triple Michelson interferometer with articulating siderostats and optical delay lines. The design uses a 7m maximum baseline and aperture diameters of 33 cm; the targeted astrometric performance is a wide-field accuracy of 5µas for 20-mag objects. The instrument would also be capable of synthesis imaging with a resolution of 10mas. Laser metrology is used to relax structural requirements thereby reducing cost. The currently envisaged flight system fits into an Atlas II shroud, for insertion into a 900 km sun-synchronous orbit.

['OSI↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

A compact cold-atom interferometer with a high data-rate grating magneto-optical trap and a photonic-integrated-circuit-compatible laser system

Abstract The extreme miniaturization of a cold-atom interferometer accelerometer requires the development of novel technologies and architectures for the interferometer subsystems. Here, we describe several component technologies and a laser system architecture to enable a path to such miniaturization. We developed a custom, compact titanium vacuum package containing a microfabricated grating chip for a tetrahedral grating magneto-optical trap (GMOT) using a single cooling beam. In addition, we designed a multi-channel photonic-integrated-circuit-compatible laser system implemented with a single seed laser and single sideband modulators in a time-multiplexed manner, reducing the number of optical channels connected to the sensor head. In a compact sensor head containing the vacuum package, sub-Doppler cooling in the GMOT produces 15 μK temperatures, and the GMOT can operate at a 20 Hz data rate. We validated the atomic coherence with Ramsey interferometry using microwave spectroscopy, then demonstrated a light-pulse atom interferometer in a gravimeter configuration for a 10 Hz measurement data rate and T = 0–4.5 ms interrogation time, resulting in Δ g / g = 2.0 × 10 −6 . This work represents a significant step towards deployable cold-atom inertial sensors under large amplitude motional dynamics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Tectonic motion site survey of the National Radio Astronomy Observatory, Green Bank, West Virginia

A geological and geophysical site survey was made of the area around the National Radio Astronomy Observatory (NRAO) to determine whether there are at present local tectonic movements that could introduce significant errors to Very Long Baseline Interferometry (VLBI) geodetic measurements. The site survey consisted of a literature search, photogeologic mapping with Landsat and Skylab photographs, a field reconnaissance, and installation of a seismometer at the NRAO. It is concluded that local tectonic movement will not contribute significantly to VLBI errors. It is recommended that similar site surveys be made of all locations used for VLBI or laser ranging.

Webster, W. J., Jr.↗

Plate motions and deformations from geologic and geodetic data

Research effort on behalf of the Crustal Dynamics Project focused on the development of methodologies suitable for the analysis of space-geodetic data sets for the estimation of crustal motions, in conjunction with results derived from land-based geodetic data, neo-tectonic studies, and other geophysical data. These methodologies were used to provide estimates of both global plate motions and intraplate deformation in the western U.S. Results from the satellite ranging experiment for the rate of change of the baseline length between San Diego and Quincy, California indicated that relative motion between the North American and Pacific plates over the course of the observing period during 1972 to 1982 were consistent with estimates calculated from geologic data averaged over the past few million years. This result, when combined with other kinematic constraints on western U.S. deformation derived from land-based geodesy, neo-tectonic studies, and other geophysical data, places limits on the possible extension of the Basin and Range province, and implies significant deformation is occurring west of the San Andreas fault. A new methodology was developed to analyze vector-position space-geodetic data to provide estimates of relative vector motions of the observing sites. The algorithm is suitable for the reduction of large, inhomogeneous data sets, and takes into account the full position covariances, errors due to poorly resolved Earth orientation parameters and vertical positions, and reduces baises due to inhomogeneous sampling of the data. This methodology was applied to the problem of estimating the rate-scaling parameter of a global plate tectonic model using satellite laser ranging observations over a five-year interval. The results indicate that the mean rate of global plate motions for that interval are consistent with those averaged over several million years, and are not consistent with quiescent or greatly accelerated plate motions. This methodology was also used to provide constraints on deformation in the western U.S. using very long baseline interferometry observations over a two-year period.

Jordan, T. H.↗

Excitation of Earth Rotation Variations "Observed" by Time-Variable Gravity

Time variable gravity measurements have been made over the past two decades using the space geodetic technique of satellite laser ranging, and more recently by the GRACE satellite mission with improved spatial resolutions. The degree-2 harmonic components of the time-variable gravity contain important information about the Earth s length-of-day and polar motion excitation functions, in a way independent to the traditional "direct" Earth rotation measurements made by, for example, the very-long-baseline interferometry and GPS. In particular, the (degree=2, order= 1) components give the mass term of the polar motion excitation; the (2,O) component, under certain mass conservation conditions, gives the mass term of the length-of-day excitation. Combining these with yet another independent source of angular momentum estimation calculated from global geophysical fluid models (for example the atmospheric angular momentum, in both mass and motion terms), in principle can lead to new insights into the dynamics, particularly the role or the lack thereof of the cores, in the excitation processes of the Earth rotation variations.

Chao, Ben F.↗

Exploring cesium properties internal to the LANSCE H - ion source using resonant absorption spectroscopy

The Los Alamos Neutron Science Center (LANSCE) H - ion source has provided stable output for decades of LANL mission needs, but its maximum beam output has remained the same at ~15 mA. A roadblock to improving beam output has been a lack of thorough understanding of the internal mechanisms of LANSCE H - ion source. The LANSCE H - Ion Source Laser Diagnostic Stand (HLDS) was recently built and commissioned to explore these internal mechanisms using laser absorption techniques, to measure and diagnose dynamic H - and cesium densities. The cesium density probe is based on resonant absorption of a continuous wave diode laser tuned though the D 2 line of cesium (~852 nm). The diagnostic capabilities of HLDS will be reviewed, and measurements using the cesium laser diagnostic will be presented.

43 PARTICLE ACCELERATORS↗

High-Precision Mapping of Diamond Crystal Strain Using Quantum Interferometry

Crystal-strain variation imposes significant limitations on many quantum sensing and information applications for solid-state defect qubits in diamond. Thus, the precision measurement and control of diamond crystal strain is a key challenge. Here, we report diamond strain measurements with a unique set of capabilities, including micron-scale spatial resolution, a millimeter-scale field of view, and a 2-order-of-magnitude improvement in volume-normalized sensitivity over previous work, reaching 5(2)×10 -8 /√Hzμm -3 (with spin-strain coupling coefficients representing the dominant systematic uncertainty). We use strain-sensitive spin-state interferometry on ensembles of nitrogen-vacancy (N-V) color centers in single-crystal bulk diamond with low strain gradients. This quantum interferometry technique provides insensitivity to magnetic-field inhomogeneity from the electronic and nuclear spin bath, thereby enabling long N-V–ensemble electronic spin dephasing times and enhanced strain sensitivity, as well as broadening the potential applications of the technique beyond isotopically enriched or high-purity diamond. We demonstrate the strain-sensitive measurement protocol first on a confocal scanning laser microscope, providing quantitative measurement of sensitivity as well as three-dimensional strain mapping; and second on a wide-field-imaging quantum diamond microscope. Our strain-microscopy technique enables fast, sensitive characterization for diamond material engineering and nanofabrication; as well as diamond-based sensing of strains applied externally, as in diamond anvil cells or embedded diamond stress sensors, or internally, as by crystal damage due to particle-induced nuclear recoils.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Scaling diode-pumped, high energy picosecond lasers to kilowatt average powers

Recent results in the development of diode-driven high energy, high repetition rate, picosecond lasers, including the demonstration of a cryogenic Yb:YAG active mirror amplifier that produces 1.5 J pulses at 500 Hz repetition rate (0.75 kW average power) are reviewed. These pulses are compressed resulting in the generation of ${\sim}5~\text{ps}$ duration, 1 J pulses with 0.5 kW average power. A full characterization of this high power cryogenic amplifier, including at-wavelength interferometry of the active region under ${>}1~\text{kW}$ average power pump conditions, is presented. An initial demonstration of operation at 1 kW average power (1 J, 1 kHz) is reported.

47 OTHER INSTRUMENTATION↗

Recent Ice Loss from the Fleming and Other Glaciers, Wordie Bay, West Antarctic Peninsula

Satellite radar interferometry data from 1995 to 2004, and airborne ice thickness data from 2002, reveal that the glaciers flowing into former Wordie Ice Shelf, West Antarctic Peninsula, discharge 6.8 +/- 0.3 km(exp 3)/yr of ice, which is 84 +/- 30 percent larger than a snow accumulation of 3.7 +/- 0.8 km(exp 3)/yr over a 6,300 km(exp 2) drainage basin. Airborne and ICESat laser altimetry elevation data reveal glacier thinning at rates up to 2 m/yr. Fifty km from its ice front, Fleming Glacier flows 50 percent faster than it did in 1974 prior to the main collapse of Wordie Ice Shelf. We conclude that the glaciers accelerated following ice shelf removal, and have been thinning and losing mass to the ocean over the last decade. This and other observations suggest that the mass loss from the northern part of the Peninsula is not negligible at present.

Sea level change↗

NASA Tech Briefs, January 2012

Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34) Sonic Thermometer for High-Altitude Balloons (35) Near-Infrared Photon-Counting Camera for High-Sensitivity Observations (36) Integrated Optics Achromatic Nuller for Stellar Interferometry (37) High-Speed Digital Interferometry (38) Ultra-Miniature Lidar Scanner for Launch Range Data Collection (39) Shape and Color Features for Object Recognition Search (40) Explanation Capabilities for Behavior-Based Robot Control (41) A DNA-Inspired Encryption Methodology for Secure, Mobile Ad Hoc Networks (42) Quality Control Method for a Micro-Nano-Channel Microfabricated Device (43) Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging (44) Electrospray Collection of Lunar Dust (45) Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring Spacecraft Attitude Tracking and Maneuver Using Combined Magnetic Actuators (46) Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

Source record↗

System to Perform Radio Frequency Interferometry Using Optical Fiber Sensing Signal Processing Techniques

Aspects of the present disclosure involve a system and method for performing radio frequency interferometry using optical fiber sensing. Optical fiber sensing is performed as a reference signal is defined and compared, in the optical domain, to incoming signals to obtain interference fringe patterns that can be used to decode phase shift offsets with respect to the designated reference signal. The phase shift offsets can be determined by first optically modulating the reference and incoming signals using a laser source as the carrier. In the optical domain, the reference and incoming signals are combined using an optical coupler and then converted back to the electrical domain for processing.

Ott, Melanie N.↗

Silicon Detector Studies with an Interferometric Thickness Mapper

Cosmic ray isotopic composition studies aboard satellites are normally based on energy detection measurements which require a precise knowledge of matter thickness particle penetration. A laser- interferometer system has been developed to precisely map the thick- ness variations of large-area silicon detectors. Design, operation, and the data processing to derive thickness maps is described.

Cosmic Rays Silicon Detectors Interferometry Satel↗