Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Recovery of Utility Fixed Costs: Utility, Consumer, Environmental and Economist Perspectives

Utilities recover costs for providing electric service to retail customers through a combination of rate components that together comprise customers’ monthly electric bills. Rates and rate designs are set by state regulators and vary by jurisdiction, utility and customer class. In addition to the fundamental tenet of setting fair and reasonable rates, rate design balances economic efficiency, equity and fairness, customer satisfaction, utility revenue stability, and customer price and bill stability. At the most basic level, retail electricity bills in the United States typically include a fixed monthly customer charge — a set dollar amount regardless of energy usage — and a volumetric energy charge for each kilowatt-hour consumed. The energy charge may be flat across all hours, vary by usage level (for example, higher rates at higher levels of usage), or vary based on time of consumption. While some utility costs, such as fuel costs, clearly vary according to electricity usage, other costs are “fixed” over the short run — generally, those that do not vary over the course of a year. Depending on your point of view, and whether the state’s electricity industry has been restructured or remains vertically integrated, the set of costs that are “fixed” may be quite limited. Or the set may extend to all capacity costs for generation, transmission and distribution. In the long run, all costs are variable. In the context of flat or declining loads in some regions, utilities are proposing a variety of changes to retail rate designs, particularly for residential customers, to recover fixed costs. In this report, authors representing utility (Chapter 1), consumer (Chapter 2), environmentalist (Chapter 3) and economist (Chapter 4) perspectives discuss fixed costs for electric utilities and set out their principles for recovering those costs. The table on the next page summarizes each author’s relative preferences for various options for fixed cost recovery, some of which may be used in combination. The specific design of any ratemaking option matters crucially, so a general preference for a given option does not indicate support for any particular application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In Situ High Energy X-ray Diffraction Characterization of Phase Transformations and Mechanical Behaviors in Rapidly Solidified Titanium and Stainless Steel Alloys [Thesis]

Advanced manufacturing techniques like additive manufacturing (AM) have poised themselves to revolutionize metal manufacturing. A wide range of AM techniques are capable of manufacturing metal components with unique, complex geometries and hastening the scientific-engineering-development cycle. Metal AM relies on a layer-by-layer rapid manufacturing process to build components from the substrate up. Rapid solidification is a large departure from traditional metal manufacturing due to its complex physics. Characterization of rapid solidification is difficult, stemming from the small volumes used in AM and the fast dynamics of the process. High energy X-ray diffraction (HEXRD) is a solution to the characterization problems of rapidly solidified alloys and AM. HEXRD can probe small volumes at fast rates and provides a wide range of thermomechanical and kinetic information. This thesis presents the application of HEXRD to rapidly solidified titanium and stainless steel alloys through a series of case studies. In the first two studies, HEXRD is applied to rapidly solidified titanium and stainless steel welds. The materials are characterized for their temperature history, phase changes, kinetics, and microstructural evolution. In the next case study, HEXRD is applied to characterize phase changes in elastocaloric NiTi shape memory alloys (SMAs) under thermomechanical load. HEXRD, in conjunction with other tools, is used to explain the superior performance of the additively manufactured SMAs. In the final two case studies, HEXRD is used to measure the mechanical response of AM parts with complex geometries; namely, the octet truss lattice. Diffraction reveals a wide range of materials information about the AM microstructure including unexpected phases, texture, and mechanical response to loading. The mechanical results from HEXRD and then compared with theoretical predictions about the performance of octet truss lattices. Summarily, HEXRD is a diverse tool that is poised to address the complex characterization problems of many aspects of the additive manufacturing process.

36 MATERIALS SCIENCE↗

Scalable, Infiltration-Free Ceramic Matrix Composite (SIF-CMC) manufacturing for Molten Salt Receiver: Investigation of particle-loaded preceramic resin

Due to their unique combination of high temperature, corrosion resistance, and toughness, Ceramic Matrix Composites (CMC) are the optimal materials to be used in the next generation of Concentrated Solar Power (CSP), which will operate at working temperatures up to 800 °C. However, today, CMC is too costly to be used in CSP applications due to its complex manufacturing process based on repeated infiltration-pyrolysis cycles. To solve this issue, PARC is developing a scalable, infiltration-free method (SIF) to manufacture CMC, which can reduce the production cost, increase batch consistency, and leverage all of the intrinsic advantages of current CMCs. The key to the SIF method is using a flowable preceramic resin with high loading of functional components. The formulation impregnates the fiber during curing and leads to high-density, low-shrinkage parts upon pyrolysis. In this paper, we demonstrate a proof-of-concept of the SIF process and report the relationships between key process parameters in the manufacturing process: functional material loading in the resin vs. resin’s flowability and morphology changes upon pyrolysis.

ceramic matrix composite, concentrated solar power↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Glauber’s Salt Composites for HVAC Applications: A Study on the Use of the T-History Method with a Modified Data Evaluation Methodology

Phase change materials (PCMs) can be utilized in buildings for peak load shifting in air conditioning systems, and the use of salt hydrate-based PCMs can reduce the cost of thermal energy storage devices. Glauber’s salt is an economical salt hydrate PCM with a melting point of around 32 °C. However, the desired melting range typically falls between 18 and 22 °C for building air conditioning applications. Although many researchers have characterized Glauber’s salt and its composites with modified melting points, enthalpy–temperature curves for composites of Glauber’s salt and NaCl are unavailable. In this study, we report the melting and solidification enthalpy–temperature curves for two different composites of Glauber’s salt and NaCl with a melting point of 21 °C obtained by the T-history method. Both composites contain NaCl to suppress the melting point, borax to reduce supercooling, and sodium polyacrylate as a thickener to enhance cyclic stability. The first composite with 12 wt.% NaCl demonstrated 139 kJ·kg−1 of latent heat of fusion, and the second composite with 9 wt.% NaCl demonstrated 171 kJ·kg−1. Both the composites have high volumetric energy densities compared to their organic counterparts with similar melting points.

Chemistry↗

Thermal Frequency Drift of 3D Printed Microwave Components

Fabrication of microwave slot array antennas and waveguide bandpass and notch filters using 3D printing has significant advantages in terms of speed and cost even for parts with high mechanical complexity. One disadvantage of Stereolithography (SLA) 3D printed, copper plated microwave components is that some SLA resins have a high Coefficient of Thermal Expansion (CTE), quoted in micrometers per meter per degree or 10 -6 per degree. Compared to typically used metals such as aluminum (CTE 24 × 10 -6 ·K -1 ) and copper (CTE 17 × 10 -6 ·K -1 ), SLA resin can have CTE above 100 × 10 -6 ·K -1 . Resonant structures experience significant frequency drift with temperature changes on the order of 10–50 °C. The issue of 3D printed microwave structures changing frequency characteristics significantly with temperature shift has not been addressed or reviewed in current literature. We measured and simulated the effect of temperature change on a slot array, cavity notch filters, and post loaded waveguide bandpass filters. We tested several types of SLA resin, different plating techniques, and also Direct Metal Laser Sintering (DMLS) and Binder Infusion metal 3D printing. Performance as a function of temperature is presented for these alternatives.

three-dimensional printing↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales in the seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are large enough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large ({approx}50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales inthe seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are largeenough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large (50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

MEASURED SPACE CONDITIONING PERFORMANCE OFA VERTICAL-BORE GROUND SOURCE HEAT PUMP (GSHP) OVER TWELVE MONTHS UNDER SIMULATED OCCUPANCY LOADS

This paper presents monthly performance metrics of a 7.56 kW (2.16 ton) GSHP serving the space conditioning loads of a 251m2 (2700ft2) residential home with a phase change material in its envelope, and a single vertical-bore 94.5m (310 ft) ground loop. The same ground loop also serviced a ground source heat pump water heater. Envelope characteristics are discussed briefly in the context of reducing thermal losses. Data on entering water temperatures, energy extracted from the ground, energy delivered/removed, compressor electricity use, COP, GSHP run times (low and high compressor stages), and the impact of fan and pump energy consumption on efficiency are presented for each month. Both practical as well as research and development issues are discussed. The findings suggest that GSHPs represent a practical technology option to reduce source energy reduction and greenhouse emissions under the IECC 2012 Standard, as well as the European Union (EU) 2020 target of generating over 25% of heat consumed in the EU from renewable energy.

Exergy↗

Switched-capacitor isolated LED driver

A switched-capacitor voltage converter which is particularly well-suited for receiving a line voltage from which to drive current through a series of light emitting diodes (LEDs). Input voltage is rectified in a multi-level rectifier network having switched capacitors in an ascending-bank configuration for passing voltages in uniform steps between zero volts up to full received voltage V.sub.DC. A regulator section, operating on V.sub.DC, comprises switched-capacitor stages of H-bridge switching and flying capacitors. A current controlled oscillator drives the states of the switched-capacitor stages and changes its frequency to maintain a constant current to the load. Embodiments are described for isolating the load from the mains, utilizing an LC tank circuit or a multi-primary-winding transformer.

30 DIRECT ENERGY CONVERSION↗

Long Term Damage Testing (NREL)

DOE's Regional Test Center program has fielded several strings of PV modules as part of their Long Term Testing program. Some of these modules have been installed since 2016 and have been exposed to severe weather events. A key to developing long lifespans for PV modules (in excess of 30 years) is understanding how damage and defects develop, propagate and progress. Researchers at the NREL Regional Test Center have started developing testing procedures and analysis tools in order to characterize modules in a controlled manner with the goal of understanding how damage spreads under normal operations. Characterization methods include EL and IR imaging, outdoor and indoor IV curves, and long term exposure monitoring. Modules to be evaluated will be chosen based on severity of defect, ability to track changes in defect and space requirements. The samples will be loaded at maximum power using grid-tied inverters or other means. Gathering and reporting on this data may help engineers and scientists design for damage and improve long-term performance.

crack damage↗

Simulation and control of a passively cooled small modular reactor Samet - 142

This work regulates a small modular reactor (SMR) with traditional control methodologies and analyzes its response to typical disturbances. An analytical model for the passively cooled NuScale SMR is developed to represent the essential dynamics. The MATLAB/Simulink based model consists of reactor core, steam generator, pressurizer, hot leg riser and downcomer, and turbine representations. The point kinetics equations with a single combined neutron precursor group and the lumped parameter representations with single-phase natural circulation account for the neutronics and thermohydraulics in the reactor core. A lumped parameter, moving-boundary approach forms the basis of the nonlinear model adopted for the once-through helical-coil heat exchangers in which boundaries between regions of different fluid states (i.e., subcooled, boiling, and superheated) vary over time. A proportional-integral-derivative controller employing a sliding-average temperature strategy commonly used for pressurized water reactors is implemented. The responses of the SMR to two different disturbances are analyzed and discussed in detail. For the first scenario, a 5% step increase in the load is applied to the system, which results in a change in the steam valve opening. For comparison, two different simulations under this same disturbance are run: one including and one excluding the control systems. The second scenario tests the effectiveness of the control system to increase (or decrease) the reactor thermal power to a certain level within a desired time period. The simulation results show that important system variables are kept at the desired values by the proposed control strategy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Stability margin analysis of the Holos-quad microreactor design

A simplified point model of the Holos-Quad microreactor is introduced. The model is based on the point kinetics equations coupled to three heat balance equations, representing the mean temperatures of the fuel particles, the graphite moderator and the helium coolant. The differential equations are converted to the frequency domain, enabling the construction of the closed-loop reactor transfer function. Using this function the stability margins of the core design is analyzed for various power levels. It is shown that the gain margins approaches infinity, demonstrating the stability of the reactor for all power levels. The phase margin at nominal power is about 60 degrees, however it shows a non-monotonous dependence on power, with minimal value obtained for about 10% of nominal power. As power level is further increased, the phase margin also increases, demonstrating the reactor becomes more stable. This behavior may be of high importance in load-follow scenarios, where the power level of the reactor changes with time. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fast Charging Infrastructure for Electrifying Road Trips to and from National Parks in the Western United States

This study investigated the fast-charging infrastructure needed by 2030 to enable seamless electrified road trips to and from national parks and monuments in seven western states: Washington, Oregon, Idaho, Wyoming, Utah, Nevada, and Arizona. It also estimated impacts to the electric grid. The research team investigated how on-route charging infrastructure projections change with different parameters or assumptions, as do related charging loads and grid impacts. NREL conducted the study in partnership with utility service provider PacifiCorp and Utah State University as part of the Western Smart Regional EV Adoption and Infrastructure at Scale project.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Experimental verification of a crystal plasticity-based simulation framework for predicting microstructure and geometric shape changes: Application to bending and Taylor impact testing of Zr

This paper is concerned with experimental verification of a recently developed multi-scale simulation framework for plastic deformation of metallic materials from quasi-static to impact deformation conditions. The framework is a visco-plastic self-consistent (VPSC) polycrystalline model embedded in an implicit finite element method (FE-VPSC) to provide a microstructure-sensitive constitutive response at each material point. Each material point of the FEM model is a polycrystalline aggregate with crystallographic deformation mechanisms operating at the single crystal scale with their evolving activity based on a dislocation density-based hardening law and texture. Four beams and three cylinders machined in different orientations from a textured plate of high-purity zirconium are tested quasi-statically in 4-point bending and at speeds of 100 m/s, 170 m/s and 243 m/s during Taylor impact tests, respectively. The variation in dimensional changes resulting from different sample orientations in the plate with respect to loading directions is measured for each sample. Moreover, texture and twinning characterization is performed using electron backscattered diffraction (EBSD). The deformation processes and underlying evolution of microstructure are successfully simulated using the FE-VPSC framework. In doing so, the model parameters are optimized and validated across a broad range of strain rates and temperatures. Simulation results in terms of geometrical changes and microstructural evolution are compared with the experimental measurements. The model predicts anisotropic material flow resulting from the hard-to-deform crystallographic directions, the development of gradients in texture and twinning through the geometries, tension–compression asymmetry, as well as the extent of plasticity under impact.

42 ENGINEERING↗

On the Use of Coupled Wind, Wave, and Current Fields in the Simulation of Loads on Bottom-Supported Offshore Wind Turbines during Hurricanes: March 2012 - September 2015

In the United States, potential offshore wind plant sites have been identified along the Atlantic seaboard and in the Gulf of Mexico. It is imperative that we define external conditions associated with hurricanes and severe winter storms and consider load cases for which wind turbines may need to be designed. We selected two hurricanes, Ike (2008) and Sandy (2012), and investigated the effect these tropical storms would have on bottom-supported offshore wind turbines that were hypothetically in or close to their path as they made landfall. For realistic turbine loads assessment, it is important that the coupled influences of the changing wind, wave, and current fields are simulated throughout the evolution of the hurricanes. We employed a coupled model--specifically, the University of Miami Coupled Model (UMCM)--that integrates atmospheric, wave, and ocean components to produce needed wind, wave, and current data. The wind data are used to generate appropriate vertical wind profiles and full wind velocity fields including turbulence; the current field over the water column is obtained by interpolated discrete output current data; and short-crested irregular second-order waves are simulated using output directional wave spectra from the coupled model. We studied two monopile-supported offshore wind turbines sited in 20 meters of water in the Gulf of Mexico to estimate loads during Hurricane Ike, and a jacket space-frame platform-supported offshore wind turbine sited in 50 meters of water in the mid-Atlantic region to estimate loads during Hurricane Sandy. In this report we discuss in detail how the simulated hurricane wind, wave, and current output data are used in turbine loads studies. In addition, important characteristics of the external conditions are studied, including the relative importance of swell versus wind seas, aerodynamic versus hydrodynamic forces, current velocity effects, yaw control options for the turbine, hydrodynamic drag versus inertia forces, and soil-structure interaction effects. A detailed framework is presented that explains how coupled inputs can be included in turbine loads studies during a hurricane. This framework can aid in future efforts aimed at developing offshore wind turbine design criteria and load cases related to hurricanes.

16 TIDAL AND WAVE POWER↗

Potential Energy Savings Due to Phase Change Material in a Building Wall Assembly: An Examination of Two Climates

Phase change material (PCM), placed in an exterior wall, alters the temperature profile within the wall and thus influences the heat transport through the wall. This may reduce the net energy transport through the wall via interactions with diurnal temperature swings in the external environment or reduce the electricity needed to meet the net load through the wall by shifting the time of the peak load to a time when the cooling system operates more efficiently. This study covers a broad range of parameters that can influence the effectiveness of such a merged thermal storage-thermal insulation system. These parameters included climate, PCM location within the wall, amount of PCM, midpoint of the PCM melting and freezing range relative to the indoor setpoint temperature, temperature range over which phase change occurs, and the wall orientation. Two climates are investigated using finite difference and optimization analyses: Phoenix and Baltimore, with two utility rate schedules. Although potential savings for a PCM with optimized properties were greater when the PCM was concentrated near the inside wall surface, other considerations described here lead to a recommendation for a full-thickness application. An examination of the temperature distribution within the walls also revealed the potential for this system to reduce the amount of energy transported through the wall framing. Finally, economic benefits can exceed energy savings when time-of-day utility rates are in effect, reflecting the value of peak load reductions for the utility grid.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Luminescent host–guest materials of electrostatically adsorbed Eu{sup 3+}(tta){sub 3}-tpyIL on zeolite L crystals

Graphical abstract: Luminescent host–guest materials exhibiting tunable emission colors by changing the excitation wavelength are obtained by surface modification of terbium(III) bipyridine-loaded zeolite L crystals with the ionic europium(III) complexes. - Highlights: • Luminescent ionic europium(III) complex was synthesized. • Outer surface of zeolite L was modified by electrostatic adsorption of the ionic complex. • Luminescent host–guest material with tunable emission color was obtained. - Abstract: The surface modification of zeolite L crystals with lanthanide complexes was achieved by electrostatic adsorption of ionic europium(III) complexes that are prepared by the reaction of tris(2-thenoyltrifluoroacetonate) europium(III) dehydrate with an organic salt containing terpyridine moieties on the negative charge-bearing surfaces of zeolite L crystals. Luminescent host–guest materials exhibiting tunable emission colors by changing the excitation wavelength are obtained by surface modification of terbium(III) bipyridine-loaded zeolite L crystals with the ionic europium(III) complexes.

36 MATERIALS SCIENCE↗