At least 919 records · Page 51

DuraLith Alkali-Aluminosilicate Geopolymer Waste Form Testing for Hanford Secondary Waste

The primary objective of the work reported here was to develop additional information regarding the DuraLith alkali aluminosilicate geopolymer as a waste form for liquid secondary waste to support selection of a final waste form for the Hanford Tank Waste Treatment and Immobilization Plant secondary liquid wastes to be disposed in the Integrated Disposal Facility on the Hanford Site. Testing focused on optimizing waste loading, improving waste form performance, and evaluating the robustness of the waste form with respect to waste variability.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly and Loading of LQS01, a Shell-Based 3.7 m Long Nb3Sn Quadrupole Magnet for LARP

The LHC Accelerator Research Program (LARP) has been engaged in the fabrication of the 3.7 m long quadrupole magnet LQS01 in order to demonstrate that Nb{sub 3}Sn magnets are a viable option for future LHC Luminosity upgrades. The LQS01 design, a scale-up of the 1 m long Technology Quadrupole TQS, includes four 3.4 m long cos(theta) coils contained in a support structure based on four 1 m long aluminum shells pre-tensioned with water-pressurized bladders (shell-type structure). In order to verify assembly procedures and loading operations, the structure was pre-stressed around solid aluminum 'dummy coils' and cooled-down to 77 K. Mechanical behavior and stress variations were monitored with strain gauges mounted on the structure and on the dummy coils. The dummy coils were then replaced with Nb{sub 3}Sn coils in a second assembly and loading procedure, in preparation for the cool-down and test. This paper reports on the cool-down test with dummy coils and on the assembly and loading of LQS01, with a comparison between 3D finite element model predictions and strain gauge data.

43 PARTICLE ACCELERATORS↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Feasibility study of offshore wind turbines with hybrid monopile foundation based on centrifuge modeling

The support structure of an offshore wind turbine (OWT) accounts for up to 25% of the capital cost; therefore, investigations into reliable and efficient foundations are critical for the offshore wind turbine industry. This paper describes an innovative hybrid monopile foundation for OWTs, which is an optimization of the original monopile foundation with broader applications. The behavior of OWTs with the hybrid monopile foundation in service conditions are investigated under lateral cyclic loadings, by considering the effects of wind, waves, and ice. A series of centrifuge tests are conducted in order to analyze these behaviors in detail, and OWT models with the original single-pile as well as wheel-only foundations are tested for comparison. Based on these tests, the accumulated lateral displacement and stiffness during cyclic loadings are presented, and the results indicate that the hybrid foundation exhibits a larger cyclic capacity than the other foundations. The influence of the cycle numbers, cyclic loading characteristics, and soil properties is examined during the tests; furthermore, the effects of these factors on the model deformation responses are illustrated. This study proposes the first analytical method for quantitatively estimating the cyclic lateral displacement of the new hybrid foundation in service conditions, and a degradation coefficient is recommended based on the test results. This method aims to provide a simple approach to predicting responses of OWTs with hybrid monopile foundations in service conditions.

17 WIND ENERGY↗

High Pressure Response of Siliceous Materials

Several siliceous (i.e., materials containing, resembling, relating to or consisting of silica or silicon dioxide) materials were examined in this study conducted by Oak Ridge National Laboratory and sponsored by the US Army TARDEC. Some were glasses (fused silica or fused quartz, Starphire soda lime silicate glass, hydrated Starphire, BOROFLOAT borosilicate glass, an iron-containing soda lime silicate glass, opal (a hydrated silicate glass), ROBAX glass ceramic, and others were single crystal (α-quartz) and polycrystalline (Coesite - a high pressure phase of crystalline quartz) ceramics. Some of these materials are presently used in transparent armor systems or are under consideration for such. The testing of these materials allowed for comparisons of glass types, glass versus glass ceramics, effect of water content, and comparison of amorphous versus crystalline materials of the same composition. The responses of these materials to high pressure loading were studied using spherical indentation testing, diamond anvil cell testing, and laser shock testing. So besides the focus of this study being on the siliceous materials, as much emphasis was placed on the efficacy of these three test methods to exploit high pressure responses. Each test is different and enables the study of different aspects of high pressure response as highlighted below. 1. Spherical indentation, when using small indenter diameters, produces both high pressure and shear, and the loading and unloading histories enabled quantification of apparent yield stress and semi-quantification of energy absorption capability (hysteresis) of the various siliceous materials. 2. Diamond anvil cell testing produces a hydrostatic stress, and when concurrently used with Raman Spectroscopy, enabled the potential identification of changes of state of material as a function of quantified pressure for the various siliceous materials. Permanent densification was also detectable. 3. Laser shock testing produces high pressures but under dynamic conditions (impact event less than 30 ns), so this enabled the study of the effect of rate on high pressure. A previously unobserved damage mechanism was revealed with this testing, and the ease or difficulty of laser-shock-induced damage initiation was deemed to be relatable to the native surface flaw population that exists on these materials.

Wereszczak, Andrew A.↗

Testing Results from the Low Activity Waste Pretreatment System (LAWPS) Full-Scale Ion Exchange Column Test and Engineering Scale Integrated System Test - 18634

The U.S. Department of Energy (DOE), Office of River Protection's (ORP) primary mission is to retrieve and treat Hanford's tank waste and close the Tank Farms to protect the Columbia River. Mixed radioactive waste is stored in 177 underground tanks at the Hanford Site as reported in DOE/ORP 2003- 02, Environmental Impact Statement for Retrieval, Treatment, and Disposal of Tank Waste and Closure of the Single Shell Tanks at the Hanford Site, Richland WA, Inventory and Source Term Data Package. The 177 underground tanks are estimated to contain about 56 million gallons of waste. The Low Activity Waste Pretreatment System (LAWPS) Project provides for the early production of immobilized low activity waste (ILAW) by feeding LAW directly from Tank Farms to the Hanford Waste Treatment Plant's (WTP's) LAW Facility, bypassing the Pretreatment Facility. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank supernatant waste will be pretreated in the LAWPS to meet the WTP LAW waste acceptance criteria. The LAWPS will also facilitate the return of secondary liquid wastes from the WTP LAW Vitrification Facility to the Tank Farms. In November of 2015 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to the AECOM team to design, fabricate and operate two test platforms to generate performance data at two different scales and demonstrate technology maturation. The first platform models the ion exchange (IX) columns at full scale, and the second platform models the integrated flowsheet (cross flow filter (CFF) and IX) at 1/9. scale. Overarching technical objectives of performing the full-scale ion exchange test and the engineering-scale integrated test are to: 1. Test interactions between unit process operations; 2. Test removal of non-radioactive cesium from process stream; 3. Test removal of undissolved solids from process stream; 4. Confirm operational flow rate range and stability; 5. Confirm volumetric throughput of waste stream over flow operating range; 6. Confirm range of process temperatures over planned operating range; 7. Establish system hydraulics and process criteria; 8. Coordinate key control and monitoring components; 9. Establish treated product chemistry meets requirements (cesium, solids, and pH); and 10. Test the hazard control strategy for a no flow condition through the IX column. Data collected during testing will be used by WRPS to validate the preliminary design, inform the final design of the permanent plant equipment, and demonstrate that the critical technology elements have advanced to a technology readiness level of 6 (prototypical system validation in a relevant environment). Testing on both platforms started in fall of 2016 generating NQA-1 data. This paper covers test results from the first five phases of testing on the 1/9. scale integrated test platform. A further three phases of testing are currently being executed, these including a 5.6 M sodium simulant containing foulant, a high viscosity simulant and finally a run performed with a lower Cs concentration (all earlier tests were spiked to 4 x Cs to reduce volume and cost). Results from these tests were not available at the time of writing available. Results are also presented from the full scale IX testing. Eight test were performed covering column loading, elution and regeneration; column loading, elution and regeneration with upflow displacement; IX column loading and gas migration; resin removal; solids accumulation; and IX column emergency recirculation and vent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel Radiometry for In-Pipe Robotic Inspection of Holdup Deposits in Gaseous Diffusion Piping - 19503

This paper details the first complete, DOE approved, deployed and operational radiometry for robotic nondestructive assay (NDA) of holdup deposits in gaseous diffusion piping. Some features, like peak-finding, Compton correction, detector efficiency, and material properties are characteristic of typical manual methods. Most features are specific to in-pipe robotic deployment. These include in-motion radiometry, self-determined location, geometric modeling of thick deposits, bounding of self-attenuation thickness and auto-checking of replicate measurements. Significant are the means for determining all the properties, equations, and constants for automatically computing and displaying all the quantities, uncertainties and information needed for NDA reporting, analysis, and review. Earlier work by this team demonstrated rudimentary but convincing robotic in-pipe NDA of holdup deposits in pipes. Cold testing with high-enrichment mat sources and hot tests with low U-235 loadings together succeeded to exhibit convincing proof-of-principle. This research-grade radiometry implementation lacked accurate odometry, efficiency calibration, high-fidelity detector modeling, attenuation modeling, forward geometric modeling, auto-segmenting, uncertainty modeling, replicate checking, deconvolution and much more. This work explains the technical basis behind robotic in-pipe NDA. It includes discussion of a new method for modeling of self-attenuation using in-pipe deposit geometry information, detail of the method's total measurement uncertainty, and explanation of calibration methods and results. Beyond development of automation-specific radiometric elements, the paper highlights analyses, testing, and technical bases specific to and supportive of the methodology. Examples include collimation characterization, detector efficiency determination, auto-calibration methodology, and odometric replicate-checking. Results of this methodology are formalized in a DOE EM Technical Basis Document, implemented in software, formally verified in review and acceptance testing and proceduralized as a means for D and D NDA at the Portsmouth enrichment facility. Measurement of U-235 quantity is a well-known cost and schedule driver in D and D of every defunct gaseous diffusion enrichment facility in the world. The radiometry methodologies and results detailed in this paper were the high hurdles. Having established the technical basis for this automated NDA, the opportunity is to apply this to many sizes and robot forms for addressing holdup deposit NDA throughout the D and D community. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Waste Loading Glass Formulation Development for High-Cr HLW, VSL-14R3060-1 (April 2014)

This report describes work performed to develop and test new glass and feed formulations with both high waste loadings and high melting rates for Hanford high level waste (HLW) with high concentrations of chromium. The testing was designed to identify glass and melter feed formulations that optimize waste loading and waste processing rate while meeting all processing and product quality requirements. The work included preparation and characterization of crucible melts to assess melt rate using a vertical gradient furnace system and testing with respect to properties that determine processability and product quality. The results from crucible-scale testing supported subsequent DM100 tests designed to further assess the enhanced glass and feed formulations with respect to processing rate and product quality. The DM100-BL, which is one of two DM100 melter systems installed at VSL, was selected as the platform for these tests due to its extensive previous use in processing rate determination for various HLW streams and glass compositions. This work builds on previous work performed at VSL for DOE to increase waste loadings in HLW glass formulations and processing rates. The testing was performed according to the Test Plan that was developed for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of wellbore casing corrosion product as a permeable porous medium

Leakage along wellbores is of concern for a variety of applications, including sub-surface fluid storage facilities, geothermal wells, and CO 2 storage wells. We have investigated whether corroded casing is permeable to gas and can serve as a leakage pathway along wellbores. Three specimens were prepared from laboratory steel plates corroded using different mechanisms to reflect different possible field conditions and produce a variety of corrosion rates. Single-phase gas flow measurements were made under a range of gas pressures to investigate flow in both the viscous and visco-inertial flow regimes. Tests were conducted at different confining stresses (range from 3.45 to 13.79 MPa) following both loading and unloading paths. The gas flow test results imply corroded casing can serve as a significant leakage path along the axis of a wellbore. Transmissivity was discovered to be sensitive to the variation in confining stress suggesting that the corrosion product is deformable. Gas slip factors and the coefficients of inertial resistance of the corrosion product were comparable to those available in the literature for other porous media. Post-test examination of the corrosion product revealed it to be a heterogeneous, mesoporous material with mostly non-uniform slit type porosity. There was no discernable difference in the composition of corrosion product from specimens corroded by different mechanisms.

02 PETROLEUM↗

Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE) through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.

17 WIND ENERGY↗

Multi-Cycle Cesium Ion Exchange Testing Using Spherical Resorcinol-Formaldehyde Resin with Diluted Hanford Tank Waste 241-AP-105

Washington River Protection Solutions requested that at least 4 L of Hanford tank waste collected from tank 241-AP-105 and diluted to approximately 5.6 M Na (AP-105DF) be prepared for use in vitrification studies. Cesium removal was required to meet this objective and the waste pretreatment platform, established at Pacific Northwest National Laboratory, was used to create the vitrification feed. The Test Platform mimicked the Low-Activity Waste Pretreatment System (LAWPS) facility planned to pretreat Hanford tank waste supernate by removing solids in a cross flow filter apparatus and processing the supernate through ion exchange columns to remove cesium. At the time of testing, the ion exchange media was targeted to be spherical resorcinol-formaldehyde (SRF) resin. The SRF resin has been tested with a wide array of simulants and process scales, but column performance testing with actual tank waste had been somewhat limited to two Hanford tank wastes (AP-101 and AN-102) in up to two process cycles. This report describes testing conducted in a total of six load elute cycles with the AP-105DF tank waste. The column system was first tested with simulant and was previously described; this report describes the six process cycle results with the AP-105DF tank waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Verification Testing of Body Forces due to a Prescribed Angular Velocity in DYNA3D/Paradyn

This report documents the verification testing and regression testing done on a new feature in DYNA3D/Paradyn, which allows users to prescribe body force loads based upon an angular velocity. This feature is unique in that the direction of the angular velocity vector follows the unit vector formed by two coordinate points associated with two nodes or the average coordinates of two separate small collection of nodes. The angular velocity direction will follow the directional vector defined by these nodes while the angular velocity magnitude is defined by a load curve. A simple single element verification test was performed to determine the correct implementation of this feature, and two separate regression tests were added to the DYNA3D Software Quality Assur ance test suite. The nodal positions, velocities, and accelerations from the solution of the single element verification test compare well to analytically derived values of those nodal quantities. The regression tests serve as good examples of this new feature’s use case and were consequently added to the SQA test suite to ensure that further modifications of the DYNA3D source code do not unintentionally change the generated baseline answers.

42 ENGINEERING↗

Experimental assessment of unvalidated assumptions in classical plasticity theory.

This report investigates the validity of several key assumptions in classical plasticity theory regarding material response to changes in the loading direction. Three metals, two rock types, and one ceramic were subjected to non-standard loading directions, and the resulting strain response increments were displayed in Gudehus diagrams to illustrate the approximation error of classical plasticity theories. A rigorous mathematical framework for fitting classical theories to the data, thus quantifying the error, is provided. Further data analysis techniques are presented that allow testing for the effect of changes in loading direction without having to use a new sample and for inferring the yield normal and flow directions without having to measure the yield surface. Though the data are inconclusive, there is indication that classical, incrementally linear, plasticity theory may be inadequate over a certain range of loading directions. This range of loading directions also coincides with loading directions that are known to produce a physically inadmissible instability for any nonassociative plasticity model.

36 MATERIALS SCIENCE↗

SOLIDIFICATION OF THE HANFORD LAW WASTE STREAM PRODUCED AS A RESULT OF NEAR-TANK CONTINUOUS SLUDGE LEACHING AND SODIUM HYDROXIDE RECOVERY

The U.S. Department of Energy (DOE), Office of River Protection (ORP), is responsible for the remediation and stabilization of the Hanford Site tank farms, including 53 million gallons of highly radioactive mixed wasted waste contained in 177 underground tanks. The plan calls for all waste retrieved from the tanks to be transferred to the Waste Treatment Plant (WTP). The WTP will consist of three primary facilities including pretreatment facilities for Low Activity Waste (LAW) to remove aluminum, chromium and other solids and radioisotopes that are undesirable in the High Level Waste (HLW) stream. Removal of aluminum from HLW sludge can be accomplished through continuous sludge leaching of the aluminum from the HLW sludge as sodium aluminate; however, this process will introduce a significant amount of sodium hydroxide into the waste stream and consequently will increase the volume of waste to be dispositioned. A sodium recovery process is needed to remove the sodium hydroxide and recycle it back to the aluminum dissolution process. The resulting LAW waste stream has a high concentration of aluminum and sodium and will require alternative immobilization methods. Five waste forms were evaluated for immobilization of LAW at Hanford after the sodium recovery process. The waste forms considered for these two waste streams include low temperature processes (Saltstone/Cast stone and geopolymers), intermediate temperature processes (steam reforming and phosphate glasses) and high temperature processes (vitrification). These immobilization methods and the waste forms produced were evaluated for (1) compliance with the Performance Assessment (PA) requirements for disposal at the IDF, (2) waste form volume (waste loading), and (3) compatibility with the tank farms and systems. The iron phosphate glasses tested using the product consistency test had normalized release rates lower than the waste form requirements although the CCC glasses had higher release rates than the quenched glasses. However, the waste form failed to meet the vapor hydration test criteria listed in the WTP contract. In addition, the waste loading in the phosphate glasses were not as high as other candidate waste forms. Vitrification of HLW waste as borosilicate glass is a proven process; however the HLW and LAW streams at Hanford can vary significantly from waste currently being immobilized. The ccc glasses show lower release rates for B and Na than the quenched glasses and all glasses meet the acceptance criterion of < 4 g/L. Glass samples spiked with Re{sub 2}O{sub 7} also passed the PCT test. However, further vapor hydration testing must be performed since all the samples cracked and the test could not be performed. The waste loading of the iron phosphate and borosilicate glasses are approximately 20 and 25% respectively. The steam reforming process produced the predicted waste form for both the high and low aluminate waste streams. The predicted waste loadings for the monolithic samples is approximately 39%, which is higher than the glass waste forms; however, at the time of this report, no monolithic samples were made and therefore compliance with the PA cannot be determined. The waste loading in the geopolymer is approximately 40% but can vary with the sodium hydroxide content in the waste stream. Initial geopolymer mixes revealed compressive strengths that are greater than 500 psi for the low aluminate mixes and less than 500 psi for the high aluminate mixes. Further work testing needs to be performed to formulate a geopolymer waste form made using a high aluminate salt solution. A cementitious waste form has the advantage that the process is performed at ambient conditions and is a proven process currently in use for LAW disposal. The Saltstone/Cast Stone formulated using low and high aluminate salt solutions retained at least 97% of the Re that was added to the mix as a dopant. While this data is promising, additional leaching testing must be performed to show compliance with the PA. Compressive strength tests must also be performed on the Cast Stone monoliths to verify PA compliance. Based on testing performed for this report, the borosilicate glass and Cast Stone are the recommended waste forms for further testing. Both are proven technologies for radioactive waste disposal and the initial testing using simulated Hanford LAW waste shows compliance with the PA. Both are resistant to leaching and have greater than 25% waste loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Panel resonant behavior of wind turbine blades.

The principal design drivers in the certification of wind turbine blades are ultimate strength, fatigue resistance, adequate tip-tower clearance, and buckling resistance. Buckling resistance is typically strongly correlated to both ultimate strength and fatigue resistance. A composite shell with spar caps forms the airfoil shape of a blade and reinforcing shear webs are placed inside the blade to stiffen the blade in the flap-wise direction. The spar caps are dimensioned and the shear webs are placed so as to add stiffness to unsupported panel regions and reduce their length. The panels are not the major flap-wise load carrying element of a blade; however, they must be designed carefully to avoid buckling while minimizing blade weight. Typically, buckling resistance is evaluated by consideration of the load-deflection behavior of a blade using finite element analysis (FEA) or full-scale static testing of blades under a simulated extreme loading condition. The focus of this paper is on the use of experimental modal analysis to measure localized resonances of the blade panels. It can be shown that the resonant behavior of these panels can also provide a means to evaluate buckling resistance by means of analytical or experimental modal analysis. Further, panel resonances have use in structural health monitoring by observing changes in modal parameters associated with panel resonances, and use in improving panel laminate model parameters by correlation with test data. In recent modal testing of wind turbine blades, a set of panel modes were measured. This paper will report on the findings of these tests and accompanying numerical and analytical modeling efforts aimed at investigating the potential uses of panel resonances for blade evaluation, health monitoring, and design.

17 WIND ENERGY↗

Failure Analysis of Three-Sheet Stackup Structure Made of Dissimilar High-Strength Steel

A three-sheet stackup structure consisting of B1500HS and B250P1 dissimilar high-strength steel was produced by resistance spot welding. The failure mode and energy absorption ability of two typical samples were investigated in typical loading state such as shear and cross-tension test. Moreover, the fracture characteristics were observed by scanning electron microscopy and the fracture process was analyzed based on the loading state. Results show two samples fracture in interfacial mode or pullout mode in shear test and fracture only in pullout mode in cross-tension test. Despite the different fracture modes, fractured sample shows ductile characteristics during mechanical tests. Compared with the sample fractured in interfacial mode, sample fractured in pullout mode has higher ultimate load and energy absorption ability in shear test. Moreover, sample absorbs more failure energy in cross-tension test than that in shear test because of the deformation of structure in cross-tension test. Both carbon equivalent and welding conditions affect the hardness of the fusion zone—a lower CE value leads to a softer HAZ which helps to promote pullout failure in the cross-tension test.

36 MATERIALS SCIENCE↗

Exploring the parameter space of MagLIF implosions using similarity scaling. I. Theoretical framework

Magneto-inertial fusion concepts, such as the magnetized liner inertial fusion (MagLIF) platform, constitute an alternative path for achieving ignition and significant fusion yields in the laboratory. The space of experimental input parameters defining a MagLIF load is highly multi-dimensional, and the implosion itself is a complex event involving many physical processes. In the first paper of this series, we develop a simplified analytical model that identifies the main physical processes at play during a MagLIF implosion. Using non-dimensional analysis, we determine the most important dimensionless parameters characterizing MagLIF implosions and provide estimates of such parameters using typical fielded or experimentally observed quantities for MagLIF. Here, we then show that MagLIF loads can be “incompletely” similarity scaled, meaning that the experimental input parameters of MagLIF can be varied such that many (but not all) of the dimensionless quantities are conserved. Based on similarity-scaling arguments, we can explore the parameter space of MagLIF loads and estimate the performance of the scaled loads. Then, in the follow-up papers of this series, we test the similarity-scaling theory for MagLIF loads against simulations for two different scaling “vectors,” which include current scaling and rise-time scaling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗