Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

Orion Hardware In The Loop OIMU Stimulation Latency Effect on Navigation State Estimation

Because Hardware In The Loop (HITL) testing involves the integration of flight software and flight hardware on the ground, non-flight-like effects may arise. One of these non-flight-like effects includes Inertial Measurement Unit (IMU) stimulation latency that affects the time in which the measurement is received by the Extended Kalman Filter (EKF). This paper seeks to present the extent to which this stimulation latency affects the navigational state estimate from the Orion navigation system for all phases of flight for Artemis II.

Christopher A Ertl↗

Standalone Hazard Evaluation and Refinement From Instrument Findings (S.H.E.R.I.F.)

The Standalone Hazard Evaluation From Instrument Findings (SHERIF) system is a set of novel algorithms and associated framework designed to support the generation of Digital Elevation Maps (DEMs) from multiple LiDAR scans and perform Hazard Detection (HD) and Safe Site Identification (SSI) with no dependencies on other onboard systems. SHERIF can employ several techniques to perform robust 3D keypoint extraction and Point Cloud registration (PCR) on disparate LiDAR scans of a planetary surface to generate a DEM which evolves over the course of a trajectory. The framework also supports a variety of Hazard Detection and Safe Site Identification algorithms which can be applied to the evolving DEM being produced. SHERIF features a robust and modular construction, allowing the user a high degree of flexibility in selecting and implementing whichever keypoint identificaiton, PCR and HD/SSI algorithms they may prefer, while maintaining the data products and sensor independence of the core SHERIF framework. SHERIF was recently evaluated via simulation and hardware-in-the-loop experimental testing at NASA Johnson Space Center.

hazard detection↗

Chemistry control and corrosion mitigation of heat transfer salts for the fluoride salt reactor (FHR)

The Molten Salt Reactor Experiment (MSRE) was a prototype nuclear reactor which operated from 1965 to 1969 at Oak Ridge National Laboratory. The MSRE used liquid fluoride salts as a heat transfer fluid and solvent for fluoride based {sup 235}U and {sup 233}U fuel. Extensive research was performed in order to optimize the removal of oxide and metal impurities from the reactor's heat transfer salt, 2LiF-BeF{sub 2} (FLiBe). This was done by sparging a mixture of anhydrous hydrofluoric acid and hydrogen gas through the FLiBe at elevated temperatures. The hydrofluoric acid reacted with oxides and hydroxides, fluorinating them while simultaneously releasing water vapor. Metal impurities such as iron and chromium were reduced by hydrogen gas and filtered out of the salt. By removing these impurities, the corrosion of reactor components was minimized. The Univ. of Wisconsin - Madison is currently researching a new chemical purification process for fluoride salts that make use of a less dangerous cleaning gas, nitrogen trifluoride. Nitrogen trifluoride has been predicted as a superior fluorinating agent for fluoride salts. These purified salts will subsequently be used for static and loop corrosion tests on a variety of reactor materials to ensure materials compatibility for the new FHR designs. Demonstration of chemistry control methodologies along with potential reduction in corrosion is essential for the use of a fluoride salts in a next generator nuclear reactor system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Gas and liquid measurements in air-water bubbly flows

Local measurements of gas- and liquid-phase flow parameters are conducted in an air-water two-phase flow loop. The test section is a vertical pipe with an inner diameter of 50 mm and a height of 3.2 m. The measurements are performed at z/D = 10. The gas-phase measurements are performed using a four-sensor conductivity probe. The data taken from this probe are processed using a signal processing program to yield radial profiles of the void fraction, bubble velocity, and interfacial area concentration. The velocity measurements of the liquid-phase are performed using a state-of-the-art Particle Image Velocimetry (PIV) system. The raw PIV images are acquired using fluorescent particles and an optical filtration device. Image processing is used to remove noise in the raw PIV images. The statistical cross correlation is introduced to determine the axial velocity field and turbulence intensity of the liquid-phase. Measurements are currently being performed at z/D = 32 to provide a more complete data set. These data can be used for computational fluid dynamic model development and validation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydrogen Production, Grid Integration, and Scaling for the Future

The project will explore near and long-term visions towards the commercialization of grid integrated electrolysis systems to inform deployment across the planning, procurement, and operation stages of hydrogen production on the grid. It will leverage NREL's state-of-the-art 1.25 MW polymer electrolyte membrane (PEM) electrolyzer system to characterize system performance in relevant scenarios, also creating a digital twin for emulation in the Advanced Research on Integrated Energy Systems (ARIES) virtual environment and performing hardware-in-the-loop (HIL) testing of pilot scale, decentralized, and centralized hydrogen systems.

electrolysis systems↗

Recent Developments in Hardware-in-the-Loop Formation Navigation and Control

The Formation Flying Test-Bed (FFTB) at NASA Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility is evolving as a modular, hybrid, dynamic simulation facility for end-tc-end guidance, navigation, and control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, are reviewed with a focus on many recent improvements. Two significant upgrades to the FFTB are a message-oriented middleware (MOM) architecture, and a software crosslink for inter-spacecraft ranging. The MOM architecture provides a common messaging bus for software agents, easing integration, arid supporting the GSFC Mission Services Evolution Center (GMSEC) architecture via software bridge. Additionally, the FFTB s hardware capabilities are expanding. Recently, two Low-Power Transceivers (LPTs) with ranging capability have been introduced into the FFTB. The LPT crosslinks will be connected to a modified Crosslink Channel Simulator (CCS), which applies realistic space-environment effects to the Radio Frequency (RF) signals produced by the LPTs.

Mitchell, Jason W.↗

Application of higher harmonic blade feathering on the OH-6A helicopter for vibration reduction

The design, implementation, and flight test results of higher harmonic blade feathering for vibration reduction on the OH-6A helicopter are described. The higher harmonic control (HHC) system superimposes fourth harmonic inputs upon the stationary swashplate. These inputs are transformed into 3P, 4P and 5P blade feathering angles. This results in modified blade loads and reduced fuselage vibrations. The primary elements of this adaptive vibration suppression system are: (1) acceleration transducers sensing the vibratory response of the fuselage; (2) a higher harmonic blade pitch actuator system; (3) a flightworthy microcomputer, incorporating the algorithm for reducing vibrations, and (4) a signal conditioning system, interfacing between the sensors, the microcomputer and the HHC actuators. The program consisted of three distinct phases. First, the HHC system was designed and implemented on the MDHC OH-6A helicopter. Then, the open loop, or manual controlled, flight tests were performed, and finally, the closed loop adaptive control system was tested. In 1983, one portion of the closed loop testing was performed, and in 1984, additional closed loop tests were conducted with improved software. With the HHC system engaged, the 4P pilot seat vibration levels were significantly lower than the baseline ON-6A levels. Moreover, the system did not adversely affect blade loads or helicopter performance. In conclusion, this successful proof of concept project demonstrated HHC to be a viable vibration suppression mechanism.

Straub, F. K.↗

CPL Materials Life Cycle Test Facility

The Capillary Pumped Loop (CPL) Materials Life Cycle Test Facility at the Goddard Space Flight Center (GSFC) will identify the operational parameters controlling the performance of a CPL over an extended period of time. The primary purpose of the facility is to investigate the long-term chemical compatibility between the anhydrous ammonia working fluid and the CPL materials of construction. Chemical reactions occurring within the system may produce non-condensable gases or particulate debris that can lead to a degradation in system performance. Small liquid samples will be drawn from the system at specific time intervals and analyzed to check for the presence of non-condensable gases. Periodic maximum and minimum heat load tests will be performed on the CPL to monitor trends in the overall system performance.

Buchko, Matthew T.↗

Geoscience Laser Altimeter System (GLAS): Final Test Report of DM LHP TV Testing

The Demonstration Model (DM) Loop Heat Pipe (LHP) was tested at Goddard Space Flight Center (GSFC) during September and October, 1999. The LHP system was placed in the Dynavac 36 in. chamber in Building 4. The test lasted for about 6 weeks. The LHP was built, designed, and manufactured at Dynatherm Corporation, Inc. In Hunt Valley, MD according to GSFC specifications. The purpose of the test was to evaluate the performance of a propylene LHP for the Geoscience Laser Altimetry System (GLAS) instrument application.

Baker, Charles↗

Testing the performance of feedback concatenated decoder with a nonideal receiver

One of the inherent problems in testing the feedback concatenated decoder (FCD) at our operating symbol signal-to-noise ratio (SSNR) is that the bit-error rate is so low that we cannot measure it directly through simulations in a reasonable time period. This article proposes a test procedure that will give a reasonable estimate of the expected losses even though the number of frames tested is much smaller than needed for a direct measurement. This test procedure provides an organized robust methodology for extrapolating small amounts of test data to give reasonable estimates of FCD loss increments at unmeasurable miniscule error rates. Using this test procedure, we have run some preliminary tests on the FCD to quantify the losses due to the fact that the input signal contains multiplicative non-white non-Gaussian noises resulting from the buffered telemetry demodulator (BTD). Besides the losses in the BTD, we have observed additional loss increments of 0.3 to 0.4 dB at the output of the FCD for several test cases with loop signal-to-noise ratios (SNR's) lower than 20 dB. In contrast, these loss increments were less than 0.1 dB for a test case with the subcarrier loop SNR at about 28 dB. This test procedure can be applied to more extensive test data to determine thresholds on the loop SNRs above which the FCD will not suffer substantial loss increments.

Feria, Y.↗

Improving Coverage of Test Cases Generated by Symbolic PathFinder for Programs with Loops

Symbolic execution is a program analysis technique that is used for many purposes, one of which is test-case generation. For loop-free programs, this generates a test-set that achieves path coverage. Program loops, however, imply exponential growth of the number of paths in the best case and non-termination in the worst case. In practice, the number of loop unwindings needs to be bounded for analysis. We consider symbolic execution in the context of the tool Symbolic Pathfinder. This tool extends the model-checker Java Pathfinder and relies on its bounded state-space exploration for termination. We present an implementation of k-bounded loop unwinding, which increases the amount of user-control over the symbolic execution of loops. Bounded unwinding can be viewed as a naive way to prune paths through loops. When using symbolic execution for test-case generation, naively pruning paths is likely at the cost of coverage. In order to improve coverage of branches within a loop body, we present a technique that semi-automatically concretizes variables used in a loop. The basic technique is limited and we therefore present annotations to manually steer symbolic execution towards certain branches, as well as ideas on how the technique can be extended to be more widely applicable.

Programs With Loops↗

Evaluation of automated stability testing in machining through closed-loop control and Bayesian machine learning

Here, this paper describes a system for automated identification of the optimal stable cutting parameters in milling through Bayesian machine learning and closed-loop control. The closed-loop control system consists of a process monitoring architecture, an analysis framework, and a feedback mechanism. The analysis framework consists of a Bayesian machine learning algorithm that learns a stability map given test results. The learned stability map is used to select parameters for stability testing using an expected improvement in the material removal rate criterion. The test parameters are communicated to the machine controller to complete the test cut through a feedback mechanism. The test cuts were monitored using an audio signal; the stability of the test cut was determined by analyzing the frequency content of the audio signal. The test result was fed back to the Bayesian learning algorithm to complete the loop. Experimental results demonstrate that the system can identify the optimal stable parameters without information about the cutting force model or the structural dynamics. The system provides a low-cost method for optimal stable parameter identification in an industrial environment.

Chatter↗

Tritium Transport Phenomena in Molten-Salt Reactors: Molten Salt Tritium Transport Experiment Design

Tritium is produced from neutron interactions with both lithium and beryllium. Large quantities of tritium are generated in Molten Salt Reactors (MSRs) which use LiF/BeF2 (FLiBe) as the fuel salt. Tritium is unique among the radionuclide hazards as it readily permeates through metal structural materials at high temperatures. All metal surfaces are potential release paths for tritium. For adequate safety analysis and eventual licensing of new reactors, predictive models for tritium transport and release from MSRs must be developed. These models must account for the multiple transport phenomena involved with tritium: fuel salt phase mass transport, dissociation/recombination reactions on metal surfaces, interstitial diffusion through the metal structure, and salt or gas phase mass transport in the downstream fluid. These models also must also be validated with representative experiments. Our previous report outlined tritium transport phenomena involved in MSRs, made suggestions on gaps in the transport dataset, and proposed an experimental test stand to test combined transport effects – tritium transport through pipe walls in a convective salt flow. In this report, we summarize an updated analysis framework for tritium transport in MSRs, report our results on hydrogen and deuterium permeation through Hastelloy N, and describe the final design of the Molten Salt Tritium Transport Experiment (MSTTE, pronounced “misty”). The MSRE provides the only wholistic experimental data set for tritium transport in MSRs and understanding the transport phenomena involved in the MSRE is crucial for future model development. One set of parameters in our analysis framework was unknown for the MSRE—surface reaction rates for tritium on Hastelloy N. This warranted our hydrogen and deuterium permeation campaign to assess the permeability, diffusivity, and solubility of hydrogen isotopes in clean Hastelloy N. Surface reaction rate constants were probed by low pressure measurements, however, no surface effects were observed in the limits of our permeation apparatus. Permeation experiments on oxidized Hastelloy N were not performed for this report but are planned in future work. The experimental test stand, MSTTE, measures combined transport properties of the salt-metal system. MSTTE is a forced convection FLiBe loop with custom designed test section to measure tritium transport through candidate structural materials. We use MSRE relevant dimensionless numbers to design and scale the test section. Hastelloy N is a candidate loop and test section material due to the relevance for the MSRE and related designs, however, other metals are being considered (e.g. 316H SS) which may better align with current vendor concepts.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Variable Load LVDT-Based Creep Test Rig for Use in ATR Loop 2A

Understanding the creep behavior of materials in a radiation environment is essential in evaluating safety issues associated with nuclear power plant operation, especially for plants applying for life extension. In US materials testing reactors (MTRs), this understanding has been achieved through a “cook and look” approach (where specimens are irradiated under load for some period of time and then removed from an MTR for post-irradiation examination). A number of “cook and look” cycles can be required for each evaluated material, which makes this approach expensive. In addition, examinations are limited to end-state conditions, which may or may not be sufficient to reveal all phenomena of interest (because examinations are not performed at prototypic conditions relative to temperature, pressure, stress, etc.).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of misalignment on mechanical behavior of metals in creep

Creep tests were conducted by means of a closed loop servocontrolled materials test system. The strain history prior to creep is carefully monitored. Tests were performed for aluminum alloy 6061-O at 150 C and were monitored by a PDP 11/04 minicomputer at a preset constant plastic strain rate prehistory. The results show that the plastic strain rate prior to creep plays a significant role in creep behavior. The endochronic theory of viscoplasticity was applied to describe the observed creep curves. Intrinsic time and strain rate sensitivity function concepts are employed and modified according to the present observation.

Wu, H. C.↗