Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Rate analysis for a hybrid quantum repeater

We present a detailed rate analysis for a hybrid quantum repeater assuming perfect memories and using optimal probabilistic entanglement generation and deterministic swapping routines. The hybrid quantum repeater protocol is based on atomic qubit-entanglement distribution through optical coherent-state communication. An exact, analytical formula for the rates of entanglement generation in quantum repeaters is derived, including a study on the impacts of entanglement purification and multiplexing strategies. More specifically, we consider scenarios with as little purification as possible and we show that for sufficiently low local losses, such purifications are still more powerful than multiplexing. In a possible experimental scenario, our hybrid system can create near-maximally entangled (F=0.98) pairs over a distance of 1280 km at rates of the order of 100 Hz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field test of continuous-variable quantum key distribution with a true local oscillator

A continuous-variable quantum key distribution (CV QKD) using a true local (located at the receiver) oscillator (LO) has been proposed to remove any possibility of side-channel attacks associated with transmission of the LO as well as reduce the cross-pulse contamination. Here we report an implementation of true LO-CV QKD using “off-the-shelf” components and conduct QKD experiments using the fiber optical network at Oak Ridge National Laboratory. A phase reference and quantum signal are time multiplexed and then wavelength division multiplexed with the classical communications that “coexist” with each other on a single optical network fiber. Importantly, this is the first demonstration of CV QKD with a receiver-based true LO over a deployed fiber network, a crucial step for its application in real-world situations.

97 MATHEMATICS AND COMPUTING↗

A Fiber Bragg Grating Temperature Sensor for 2-400 K

We demonstrate fiber optic, multiplexible temperature sensing using a fiber Bragg grating (FBG) with an operational range of 2-400 K, and a temperature resolution better than 10 mK for temperatures < 12 K. This represents a significant reduction in the lowest usable temperature as well as a significant increase in sensitivity at cryogenic temperatures compared with previously reported multiplexible solutions. This is accomplished by mounting the section of the fiber with a FBG on a polytetrafluoroethylene coupon, which has a non-negligible coefficient of thermal expansion down to < 4 K. The sensors exhibit a good stability over multiple temperature cycles and acceptable sensor-to-sensor repeatability. Possible applications for this sensor include distributed temperature sensing across superconducting elements and cryogenic temperature measurements in environments where electrical measurements are impractical or unsafe.

Zaynetdinov, Madrakhim↗

A Cryogenic readout integrated circuit with analog pile-up and in-Pixel ADC for high frame rate Skipper CCD-in-CMOS Sensors

The Skipper CCD-in-CMOS Parallel Read-Out Circuit V2 (SPROCKET2) is designed to enable high frame rate readout of Skipper CCD-in-CMOS image sensors. The SPROCKET2 pixel is fabricated in a 65 nm CMOS process and occupies a 60$\mu$m $\times$ 60$\mu$m footprint. SPROCKET2 is intended to be heterogeneously integrated with a pixelated Skipper CCD-in-CMOS sensor, such that one readout pixel is connected to a multiplexed array of 16 active image sensor pixels, to match their spatial geometry. Our design benefits from the Skipper CCD-in-CMOS sensor's non-destructive readout capability to achieve exceptionally low noise through multi-sampling and averaging while optimizing for total power consumption. The pixel readout utilizes correlated double sampling to minimize 1/f noise and includes "pile-up" of ten successive samples in the analog domain before digitizing at a rate of 66.7 ksps. Measurement results of in-pixel serial SAR ADC show DNL and INL of ~0. 44 LSB and 0.58 LBS respectively. A large area array of 20,000 SPROCKET2 ADC pixels (multiplexed 1:16 to 320,000 sensor pixels) is currently under test. By reading out data over a 10 Gbps optical link, this pixel design enables a frame rate of $\sim$ 4 kfps for large sensing areas with minimal sensing deadtime. In the highest gain mode, the pixelated ADC has an input-referred resolution of 10$\mu$V with a simulated power consumption of 50$\mu$W. The pixel operates with constant current draw to minimize power-rail crosstalk.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Externally-Modulated Electro-Optically Coupled Detector Architecture for Nuclear Physics Instrumentation

A new laser-based externally-modulated electro-optically coupled detector (EOCD) architecture is being developed to enable high-density readout for radiation detectors with accurate analog radiation pulse shape and timing preservation. Unlike digital conversion before electro-optical modulation, the EOCD implements complete analog optical signal modulation and multiplexing in its detector front-end. The result is a compact, high performance detector readout that can be both radiation tolerant and immune to magnetic fields. In this work, the feasibility of EOCD was explored by constructing a two-wavelength laser-based externally-modulated EOCD, and testing analog pulse shape preservation and wavelength-division multiplexing (WDM) crosstalk. Comparisons were first made between the corresponding initial pulses and the electro-optically coupled analog pulses. This confirmed an excellent analog pulse preservation over $ sim {hbox {29}}% $ of the modulator’s switching voltage range. Optical spectrum analysis revealed less than $-{hbox {14}}~hbox{dB}$ crosstalk with 1.2 nm WDM wavelength bandgap, and provided insight on experimental conditions that could lead to increased inter-wavelength crosstalk. Further discussions and previous research on the radiation tolerance and magnetic field immunity of the candidate materials were also given, and quantitative device testing is proposed in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Irradiation of a Multichannel JFET-Based Optical Encoder

Modern electrical components are susceptible to damage from high levels of radiation and extreme temperatures found near reactors in terrestrial nuclear power plants and in aerospace applications. Radiation-hardened electronics are being developed, largely for the aerospace industry, but they sometimes rely on application-specific, small-batch semiconductor fabrication processes. These processes tend to be prohibitively expensive to develop and maintain outside major industrial facilities or governmental agencies. Recently, commercially available, nonradiation-rated junction-gate field-effect transistors (JFETs) were shown to maintain their functionality at gamma doses exceeding 1 MGy, suggesting that nonrated, commercially available electrical components could be used to develop systems that are tolerant to ionizing radiation. However, gamma ray survival is not indicative of neutron dose survival, and few studies characterize JFETs under neutron irradiation. To address this knowledge gap, a JFET-based analog multiplexer and optical pulsewidth modulation (PWM) encoder was developed and irradiated using a 252 Cf source to 1.6×10 13 n/cm 2 . The multiplexed optical encoder (MOE) system maintained functionality throughout testing and showed little evidence of radiation effects. These results indicate that circuitry tolerant to fast neutron damage can be developed using low-cost, nonradiation-rated, commercially available JFETs, which could provide a lower production cost alternative to specialized semiconductor processes when designing and building electronics better able to survive neutron irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constitutive and inducible oleoresin defenses share genetic architectures and mechanisms in Pinus taeda

The oleoresin defense system of loblolly pine (Pinus taeda) protects trees from insects and pathogens and is an important source of renewable biofuels and chemicals, but the genetic basis of oleoresin production is poorly understood. We characterized the genetic architecture of oleoresin flow, resin canal number, stem wood terpene content, and monoterpene composition in two clonal populations of P. taeda. We used quantitative genetic analyses, genome-wide association studies (GWASs), multiplex network learning, and gene expression profiling to elucidate shared gene networks underlying defense traits and to identify high-quality candidates for breeding and engineering loblolly pine. Genetic analyses revealed polygenic inheritance and trait-to-trait correlations provide strong evidence for shared genes regulating constitutive and induced oleoresin flow. We identified 236 single nucleotide polymorphisms associated with oleoresin flow, resin canal number, and terpene composition and highlight candidate genes likely involved in terpene biosynthesis, cambial meristem reprogramming, and pathogen perception and immune signaling. Fourteen GWAS candidates were methyl jasmonate-responsive in tissues where resin canals initiate and terpene production occurs. Integrating quantitative genetics, GWAS, gene expression, and multiplex network analyses enabled the prioritization of high-quality candidate genes. This work advances the development of more resilient loblolly pine optimized for ecological performance, renewable chemical, and biofuel production.

genome-wide association study↗

Development of XFCT imaging strategy for monitoring the spatial distribution of platinum-based chemodrugs: Instrumentation and phantom validation

Purpose: Developing an imaging method to directly monitor the spatial distribution of platinum-based (Pt) drugs at the tumor region is of critical importance for early assessment of treatment efficacy and personalized treatment. In this study, the authors investigated the feasibility of imaging platinum (Pt)-based drug distribution using x-ray fluorescence (XRF, a.k.a. characteristic x ray) CT (XFCT). Methods: A 5-mm-diameter pencil beam produced by a polychromatic x-ray source equipped with a tungsten anode was used to stimulate emission of XRF photons from Pt drug embedded within a water phantom. The phantom was translated and rotated relative to the stationary pencil beam in a first-generation CT geometry. The x-ray energy spectrum was collected for 18 s at each position using a cadmium telluride detector. The spectra were then used for the K-shell XRF peak isolation and sinogram generation for Pt. The distribution and concentration of Pt were reconstructed with an iterative maximum likelihood expectation maximization algorithm. The capability of XFCT to multiplexed imaging of Pt, gadolinium (Gd), and iodine (I) within a water phantom was also investigated. Results: Measured XRF spectrum showed a sharp peak characteristic of Pt with a narrow full-width at half-maximum (FWHM) (FWHM{sub K{alpha}1}= 1.138 keV, FWHM{sub K{alpha}2}= 1.052 keV). The distribution of Pt drug in the water phantom was clearly identifiable on the reconstructed XRF images. Our results showed a linear relationship between the XRF intensity of Pt and its concentrations (R{sup 2}= 0.995), suggesting that XFCT is capable of quantitative imaging. A transmission CT image was also obtained to show the potential of the approach for providing attenuation correction and morphological information. Finally, the distribution of Pt, Gd, and I in the water phantom was clearly identifiable in the reconstructed images from XFCT multiplexed imaging. Conclusions: XFCT is a promising modality for monitoring the spatial distribution of Pt drugs. The technique may be useful in tailoring tumor treatment regimen in the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-J-03: Development of a Human Brain PET for On-Line Proton Beam-Range Verification

Purpose: To develop a prototype PET for verifying proton beam-range before each fractionated therapy that will enable on-line re-planning proton therapy. Methods: Latest “edge-less” silicon photomultiplier arrays and customized ASIC readout electronics were used to develop PET detectors with depth-of-interaction (DOI) measurement capability. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together to form a large detector panel. Detectors with 1.5×1.5 and 2.0×2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables or PCB board to dedicated ASIC front-end electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition of coincidence events and data transfer. The modular detector and scalable electronics/data acquisition will enable flexible PET system configuration for different imaging geometry. Results: Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ∼18% and 2.8 ns energy and timing resolutions, and around 2–3 mm DOI resolution. A small prototype PET scanner with one detector ring has been built and evaluated, validating the technology and design. A large size detector panel has been fabricated by scaling up from modular detectors. Different designs of resistor and capacitor based signal multiplexing boards were tested and selected based on optimal crystal identification and timing performance. Stackable readout electronics boards and FPGA-based data acquisition boards were developed and tested. A brain PET is under construction. Conclusion: Technology of large-size DOI detector based on SiPM array and advanced readout has been developed. PET imaging performance and initial phantom studies of on-line proton beam-range measurement will be conducted and reported. NIH grant R21CA187717; Cancer Prevention and Research Institute of Texas grant RP120326.

60 APPLIED LIFE SCIENCES↗

A Landing Pad System for Multicopy Gene Integration in Issatchenkia orientalis

The robust nature of the non-conventional yeast Issatchenkia orientalis allows it to grow under highly acidic conditions and therefore, has gained increasing interest in producing organic acids using a variety of carbon sources. Recently, the development of a genetic toolbox for I. orientalis, including an episomal plasmid, characterization of multiple promoters and terminators, and CRISPR-Cas9 tools, has eased the metabolic engineering efforts in I. orientalis. However, multiplex engineering is still hampered by the lack of efficient multicopy integration tools. To facilitate the construction of large, complex metabolic pathways by multiplex CRISPR-Cas9-mediated genome editing, we developed a bioinformatics pipeline to identify and prioritize genome-wide intergenic loci and characterized 47 gRNAs located in 21 intergenic regions. These loci are screened for guide RNA cutting efficiency, integration efficiency of a gene cassette, the resulting cellular fitness, and GFP expression level. We further developed a landing pad system using components from these well-characterized loci, which can aid in the integration of multiple genes using single guide RNA and multiple repair templates of the user’s choice. We have demonstrated the use of the landing pad for simultaneous integrations of 2, 3, 4, or 5 genes to the target loci with efficiencies greater than 80%. As a proof of concept, we showed how the production of 5-aminolevulinic acid can be improved by integrating five copies of genes at multiple sites in one step. We have further demonstrated the efficiency of this tool by constructing a metabolic pathway for succinic acid production by integrating five gene expression cassettes using a single guide RNA along with five different repair templates, leading to the production of 9 g/L of succinic acid in batch fermentations. This study demonstrates the effectiveness of a single gRNA-mediated CRISPR platform to build complex metabolic pathways in a non-conventional yeast. This landing pad system will be a valuable tool for the metabolic engineering of I. orientalis.

Fatma, Zia↗

Investigation of Plasmodium falciparum pfhrp2 and pfhrp3 gene deletions and performance of a rapid diagnostic test for identifying asymptomatic malaria infection in northern Ethiopia, 2015

Background: Rapid diagnostic tests (RDTs) are widely used for malaria diagnosis of both symptomatic and asymptomatic infections. Although RDTs are a reliable and practical diagnostic tool, the sensitivity of histidine-rich protein 2 (HRP2)-based RDTs can be reduced if pfhrp2 or pfhrp3 (pfhrp2/3) gene deletions exist in the Plasmodium falciparum parasite population. This study evaluated dried blood spot (DBS) samples collected from a national household survey to investigate the presence of pfhrp2/3 deletions and the performance of the RDT used in the cross-sectional survey in a low transmission setting. Methods: The 2015 Ethiopia Malaria Indicator Survey tested household members by RDT and collected DBS samples. DBS (n = 2648) from three regions in northern Ethiopia were tested by multiplex bead-based antigen detection assay after completion of the survey. The multiplex assay detected pan-Plasmodium lactate dehydrogenase (LDH), pAldolase, and HRP2 antigens in samples. Samples suspected for pfhrp2/3 gene deletions (pLDH and/or pAldolase positive but low or absent HRP2) were further investigated by molecular assays for gene deletions. Antigen results were also compared to each individual’s RDT results. Dose–response logistic regression models were fit to estimate RDT level of detection (LOD) antigen concentrations at which 50, 75, 90, and 95% of the RDTs returned a positive result during this survey. Results: Out of 2,648 samples assayed, 29 were positive for pLDH or pAldolase antigens but low or absent for HRP2 signal, and 15 of these samples (51.7%) were successfully genotyped for pfhrp2/3. Of these 15 P. falciparum infections, eight showed single deletions in pfhrp3, one showed a single pfhrp2 deletion, and six were pfhrp2/3 double-deletions. Six pfhrp2 deletions were observed in Tigray and one in Amhara. Twenty-five were positive for HRP2 by the survey RDT while the more sensitive bead assay detected 30 HRP2-positive samples. A lower concentration of HRP2 antigen generated a positive test result by RDT compared to pLDH (95% LOD: 16.9 ng/mL vs. 319.2 ng/mL, respectively). Conclusions: There is evidence of dual pfhrp2/3 gene deletions in the Tigray and Amhara regions of Ethiopia in 2015. As the prevalence of malaria was very low (< 2%), it is difficult to make strong conclusions on RDT performance, but these results challenge the utility of biomarkers in household surveys in very low transmission settings.

60 APPLIED LIFE SCIENCES↗

Quantification of mutant SPOP proteins in prostate cancer using mass spectrometry-based targeted proteomics

Speckle-type POZ protein (SPOP) is an E3 ubiquitin ligase adaptor protein that functions as a potential tumor suppressor, and SPOP mutations have been identified in ~10% of human prostate cancers. However, it remains unclear if mutant SPOP proteins can be utilized as biomarkers for early detection, diagnosis, prognosis or targeted therapy of prostate cancer. Moreover, the SPOP mutation sites are distributed in a relatively short region where multiple lysine residues, posing significant challenges for bottom-up proteomics analysis of the SPOP mutations. To address this issue, PRISM (high-pressure, high-resolution separations coupled with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry assays have been developed for quantifying wild-type SPOP protein and 11 prostate cancer-derived SPOP mutations. Despite inherent limitations due to amino acid sequence constraints, all the PRISM-SRM assays developed using Arg-C digestion showed a linear dynamic range of at least two orders of magnitude, with limits of quantification range from 0.1 to 1 fmol/μg of total protein in the cell lysate. Applying these SRM assays to analyze HEK293T cells with and without expression of the three most frequent SPOP mutations in prostate cancer (Y87N, F102C or F133V) led to confident detection of all three SPOP mutations in corresponding positive cell lines but not in the negative cell lines. Expression of the F133V mutation and wild-type SPOP was at much lower levels compared to that of F102C and Y87N mutations; however, at present it is unknown if this also affects the activity of the SPOP protein. In summary, PRISM-SRM enables multiplexed, isoform-specific detection of mutant SPOP proteins in cell lysates, which holds great potential in biomarker development for prostate cancer.

59 BASIC BIOLOGICAL SCIENCES↗

INTREPID program: technology and architecture for next-generation, energy-efficient, hyper-scale data centers [Invited]

The INTREPID program is developing power-efficient coherent optics for package-level integration with future switch integrated circuits as a path to realizing higher-radix switches for flatter networks. The link architecture is underpinned by coherent quadrature phase-shift keying (QPSK) polarization-multiplex transceivers at 200 Gb/s per λ <#comment/> , further enhanced with wavelength division multiplexing (WDM) to enable energy-efficient 800 or 1600 Gb/s inter-switch fiber connections. The technology is compatible with conventional three-level data center designs as well as a two-level data center design introduced here, which includes an added layer of passive, arrayed waveguide grating routers (AWGRs) or WDM circuit switches to further improve the cost, energy efficiency, and latency of the network.

Saleh, Adel A. M. (ORCID:0000000182451136)↗

Burst-mode dual-comb spectroscopy

We introduce a new modality of dual-comb spectroscopy that enables a simplified and powerful new approach for time-resolved measurements with increased acquisition rates. This "burst mode" form of dual-comb spectroscopy (BM-DCS) relies on the multiplexing of each probe pulse into a short train of pulses. With this approach we demonstrate a time-resolved series of absorption-based spectroscopic measurements of a laser-induced plasma using only a single laser ablation shot and identify 22 Nd lines not previously reported in the literature. The transmission spectra spanned 3.1 THz and were acquired at an effective acquisition rate of 25 kHz with 40 ms time-resolution. This simple modification to 100 MHz level dual-comb systems provides a flexible approach for studying transient and low duty-cycle events such as laser-induced plasmas, combustion, and explosive reactions.

(280.5395) Plasma Diagnostics, broadband laser spe↗

Highly cascaded first-order sapphire optical fiber Bragg gratings fabricated by a femtosecond laser

This Letter reports an innovative technique for fabricating large-scale, highly cascaded first-order sapphire optical fiber Bragg gratings (FBGs) using a femtosecond laser-assisted point-by-point inscription method. For the first time, to the best of our knowledge, this study successfully demonstrates a distributed array of 10 FBGs within highly multimode sapphire crystal fiber, made possible by employing a high-power laser technique to generate larger reflectors with a Gaussian intensity profile. These first-order FBGs offer advantages such as enhanced reflectivity, shorter fabrication time, and simplified spectral characteristics, making them easier to interpret compared with high-order FBGs. The FBGs’ resilience and effectiveness are analyzed by subjecting them to temperature tests, proving their capacity for accurate temperature monitoring up to 1500°C—a testament to their suitability for harsh environments. This novel approach broadens the scope for sensing and communication applications in sapphire fibers, particularly under challenging conditions. The novelty of our work lies in successfully overcoming the limitations of previous designs by integrating a cascade of 10 FBGs in sapphire fibers, thereby enhancing multiplexing capabilities, minimizing overlapping of FBG peaks, and ensuring reliable temperature monitoring in industries and applications with thermal gradients.

47 OTHER INSTRUMENTATION↗

Generation and characterization of ultrabroadband polarization–frequency hyperentangled photons

We generate ultrabroadband photon pairs entangled in both polarization and frequency bins through an all-waveguided Sagnac source covering the entire optical C- and L-bands (1530–1625 nm). We perform comprehensive characterization of high-fidelity states in multiple dense wavelength-division multiplexed channels, achieving full tomography of effective four-qubit systems. Additionally, leveraging the inherent high dimensionality of frequency encoding and our electro-optic measurement approach, we demonstrate the scalability of our system to higher dimensions, reconstructing states in a 36-dimensional Hilbert space consisting of two polarization qubits and two frequency-bin qutrits. Our findings hold potential significance for quantum networking, particularly dense coding and entanglement distillation in wavelength-multiplexed quantum networks.

42 ENGINEERING↗

Distributed fiber sensing systems for 3D combustion temperature field monitoring in coal-fired boilers using optically generated acoustic waves (Final Report)

In this project, we have developed and tested three kinds of fiber optic sensing systems for real time monitoring of temperature variations within an industrial scale boiler furnace. The fiber optic sensing systems target spatial and temporal distributions of high temperature profiles in a boiler furnace in fossil power plants. The reconstructed temperature profile will provide critical input for the control mechanisms to optimize the combustion process. This temperature profile will address the essential problem for fossil power plants in achieving higher efficiency and fewer pollutant emissions. Acoustic pyrometer systems have been used to reconstruct temperature field of power plant boilers based on measuring TOF (times-of-flight) of sound waves along some straight paths in a 2D cross-section of the boiler. In this project, optically generated acoustic signals from a fiber optic sensing system have replaced the acoustic signals generated from an electrical transducer. A 3D reconstruction algorithm replaced the previous 2D model. In this project, three kinds of fiber optic sensing systems have been developed and tested. They are fiber optic sensing system I, fiber optic sensing system II (Distributed Sensing System I) and fiber optic sensing system III (Distributed Sensing System II). For fiber optic sensing system I, the fiber optic ultrasound generator acts as a signal generator. A microphone, hydrophone or other electronic devices serve as a signal receiver. In this system, there are one generator and one receiver. Distance test, water temperature test, air temperature test, air temperature reconstruction, and GE ISBF pilot test were performed by Fiber optic sensing system I. The fiber optic sensing system I successfully detected temperature in all these tests. We got 2D temperature reconstruction results by using the fiber optic sensing system I and it matched the reference data. The fiber optic sensing system I successfully survived in GE ISBF boiler environment (480 °F). For fiber optic sensing system II (Distributed Sensing System I), it is an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Fiber Bragg Grating (FBG) and Fabry-Perot (FP) sensor act as a signal receiver. In this system, there is one generator and one receiver. Aluminum plate temperature test, furnace high temperature test, and GE ISBF pilot test were performed by the fiber optic sensing system II. Fiber optic sensing system II successfully detected the temperature in all these tests. The fiber optic sensing system II successfully survived at up to 700 °C furnace environment and 320 °C GE ISBF boiler environment. For fiber optic sensing system III (Distributed Sensing System II), it is also an all optical ultrasound system. The fiber optic ultrasound generator acts as a signal generator. Multiple FP fiber sensors act as signal receivers. In this system, there is one generator and three receivers. Three GE ISBF pilot tests were performed by fiber optic sensing system III. The fiber optic sensing system III survived in the cold flow tests in GE’s ISBF pilot test facility. However, we didn’t get high temperature data by using this system since the nanosecond laser issues. During the period of the project, test trials, data simulation and algorithm optimization was performed successfully. For real time temperature field construction, the sampling rate must be fast enough to capture the field variations. The technology of Code-division multiple access (CDMA) is well studied which could allow parallel multiplexing, even if signals overlap in time or frequencies. Moreover, it has been known that extending the length of signal significantly improves SNR. For acoustic signals, these multiplexing techniques have also been widely used, mainly for sonar and acoustic communications. The CDMA modulation technique has been proposed and studied to guarantee high network throughput, low channel access delay and low energy consumption. We have studied the temperature field reconstruction using Gaussian Radial Basis Functions (GRBF)-based approximation approach. Reconstruction of 3D temperature field using Neural Networks with measured TOF and known propagation paths is feasible. 2D and 3D temperature field reconstruction simulation results are achieved. The milestone status is shown in Table 1. We finished milestone 1-8 and milestone 10. For milestone 9, we did three pilot tests by using the fiber optic sensing system III (Distributed Sensing System II) at GE Power. However, due to the failure of the ns laser, we did not get the temperature results. We conducted some additional tasks that were not originally proposed: 1) We fabricated a fiber optic sensing system I and did a pilot test based on this system. 2) In the proposal, we proposed two pilot tests at GE Power. In reality, we finished at least seven pilot tests at GE Power. GE Power has made a lot of efforts for supporting the pilot tests. 3) We got a simulation results based on CDMA. In summary, most of the tasks have been accomplished. The outcome of this project removed a few barriers that hinder the achievement of the final product of the distributed sensing systems. With the successful accomplishment of this project, a prototype of the fiber optic sensing system can be fabricated to attract more interests from companies and other funding agencies.

47 OTHER INSTRUMENTATION↗

A Handheld Medical Diagnostic Device for Harsh Environments

Medical diagnostic capabilities for extreme environments, are currently limited in nature to single marker type assays. We propose to develop a handheld device for medical diagnostics in extreme environments that provide sensitive and specific detection of biomarkers with an emphasis initially on radiation exposure. Such a device will have multiple uses, and will be easily adaptable to many applications. For example, first responders, the battlefield, in low resource settings in developing countries facing emerging disease outbreaks, and during long-duration space flights. To this end, we will develop highly adaptable microfluidic devices (cards) for profiling different biomarkers with an emphasis on those related to radiation exposure. We will leverage the previous centrifugal separator work from LLNL and Sandia National Laboratory. The radiation exposure biomarker work at LLNL will provide a biological platform for demonstrating the utility of the device. We will develop a fluidic system using a pump-less mechanical method (centrifugal) to move, control, order and layer fluids in the platform. This decreases complexity, while enabling simultaneous cell separation and plasma generation for two uses: the first is differential blood cell counts and the second is biomarker assay panels. This work will be accomplished in three Aims: Aim 1) Test multiplex microfluidic cards and integrated reader. Aim 2) Demonstrate system capabilities to take and process blood samples for multi-endpoint analysis. Aim 3) Test multiplex detection based on measuring differential blood cell counts, while measuring plasma protein biomarkers. The proposed work addresses the mission research challenge of chemical and biological countermeasure in that our work aims to provide new research capabilities to respond to man-made or natural outbreaks of pandemic diseases in particular in low resource and triage environments.

60 APPLIED LIFE SCIENCES↗