Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Performance and Health Test Procedure for Grid Energy Storage Systems: Preprint

A test procedure to evaluate the performance and health of field installations of grid-connected battery energy storage systems (BESS) is described. Performance and health metrics captured in the procedures are: Round-trip efficiency, Standby losses, Response time/accuracy, and Useable Energy/ State of Charge at different discharge/charge rates over the system's lifetime. The procedures are divided into Reference Performance Tests, which require the system to be put in a test mode and are to be conducted in intervals, and Real-time Monitoring tests, which collect data during normal operation without interruption. The procedures can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.can be applied on a wide array of BESS with little modifications and can thus support BESS operators in the management of BESS field installations with minimal interruption and expenditures.

25 ENERGY STORAGE↗

Single-Event Gate Rupture and Single-Event Burnout Test Results Performed on Hi-Rel Fuji Power MOSFETs: 2SK4217, 2SK4152, 2SK4155, and 2SK4158

Several newly available Hi-Rel total dose hardened power MOSFETs manufactured by Fuji Electric Device Technology Co. Ltd (FDT) in conjunction with the Japan Aerospace Exploration Agency (JAXA) were tested for single-event gate rupture (SEGR) and single-event burnout (SEB). The safe-operating area (SOA) of the 2SK4217 (a 100 V rated device), 2SK4152 (130 V), 2SK4155 (200 V), and the 2SK4158 (250 V) were tested with silver (Ag) and xenon (Xe) ions having incident LETs of 42.2 and 53.1 MeV cm2/mg, respectively. Test results show these devices are comparable to currently available total dose hardened technology.

Selva, Luis E.↗

Orbiter S-band direct link system verification test report

Space-to-ground S-band communications system compatibility and performance tests were performed for the various radio frequency links. These tests consisted of the various uplink and downlink signal combinations (data rates) for the phase modulation system and both realtime and playback data rates for the frequency modulated downlink systems. In addition, tests involving encryption/decryption, Doppler, and acquisition were performed. Results show that the S-band transponder for the space shuttle orbiter is compatible with the S-band equipment of the AFSCF/RTS (Air Force Satellite Control Facility/Remote Tracking Station). It is also concluded that the performance of the orbiter-AFSCF/RTS direct link exceeds the required performance and that this communications link will meet the system requirements of the Space Transportation System.

Vermillion, B. K.↗

Test beam performance measurements for the Phase I upgrade of the CMS pixel detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. Here in this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,\mu \mathrm{m}$ and $7.99\pm0.21\,\mu \mathrm{m}$ along the $100\,\mu \mathrm{m}$ and $150\,\mu \mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the IMP-16 microprocessor orbit determination system filter

The results of the numerical tests performed in evaluating the interplanetary monitoring platform-16 orbit determination system are presented. The system is capable of performing orbit determination from satellite to satellite tracking data in applications technology satellite range and range rate format. The estimation scheme used is a Kalman filter, sequential (recursive) estimator. Descriptions of the tests performed and tabulations of the numerical results are included.

Shenitz, C. M.↗

A laser-sheet flow visualization technique for the large wind tunnels of the National Full-Scale Aerodynamics Complex

A flow visualization technique for the large wind tunnels of the National Full Scale Aerodynamics Complex (NFAC) is described. The technique uses a laser sheet generated by the NFAC Long Range Laser Velocimeter (LRLV) to illuminate a smoke-like tracer in the flow. The LRLV optical system is modified slightly, and a scanned mirror is added to generate the sheet. These modifications are described, in addition to the results of an initial performance test conducted in the 80- by 120-Foot Wind Tunnel. During this test, flow visualization was performed in the wake region behind a truck as part of a vehicle drag reduction study. The problems encountered during the test are discussed, in addition to the recommended improvements needed to enhance the performance of the technique for future applications.

Reinath, M. S.↗

Ultra-High Operation Temperature SiC-matrix Solar Thermal Air Receiver (HOTSSTAR) enabled by additive manufacturing: Test Facility & Performance Evaluations

Solar Heat for Industrial Processes (SHIP) cavity receivers are capable of generating electricity or industrial process heat by absorbing thermal energy from solar radiation, focused on a small area. The concentration of solar radiation on the small area of the receiver enables the achievement of high temperatures (ranging from 400°C to 1,100°C) of a working fluid, thus making the SHIP technology thermodynamically comparable with conventional power plants. A volumetric receiver consists of a porous structure-generally made of silicon carbide or metal, which absorbs solar radiation and converts it into heat energy. Heat energy from the porous materials is then transferred to the fluid following through them. A volumetric receiver acts as a convective heat exchanger, transferring heat to the fluid through convection. Open-loop volumetric receivers work with air at atmospheric pressure and are suitable for single-cycle or multi-cycle energy plants. A Model Based Systems Engineering (MBSE) approach was used to develop a test bed at Sandia national Laboratories (SNL) capable of demonstrating an open-loop volumetric air receiver developed by General Electric Aerospace (GE Aerospace). This paper presents the development of the various MBSE methods, test bed, and testing operations for the GE air receiver, which was experimentally demonstrated to achieve 1,350°C for over 3 hours of operation and an approximate 70% receiver efficiency. By being able to achieve such high temperatures >1,000°C, this work provides the potential to support many SHIP industrial use cases.

14 SOLAR ENERGY↗

Quantitative Evaluation of 3 DBMS: ORACLE, SEED AND INGRES

Characteristics required for NASA scientific data base management application are listed as well as performance testing objectives. Results obtained for the ORACLE, SEED, and INGRES packages are presented in charts. It is concluded that vendor packages can manage 130 megabytes of data at acceptable load and query rates. Performance tests varying data base designs and various data base management system parameters are valuable to applications for choosing packages and critical to designing effective data bases. An applications productivity increases with the use of data base management system because of enhanced capabilities such as a screen formatter, a reporter writer, and a data dictionary.

Sylto, R.↗

Passive Noise Analysis for Advanced Tamper Indication. End of Year Report 2015

Idaho National Laboratory (INL) is part of a multi-lab project assessing front-end electronics for unattended measurement (FEUM) being developed for the International Atomic Energy Agency (IAEA) unattended systems. The FEUM development activity provides an opportunity to address tampering detection between FEUM and the detector, signal integrity from FEUM to the data acquisition systems, and data validity – long-standing challenges for the IAEA. This report summarizes the INL activities in Fiscal Year (FY) 2015 to characterize and test passive noise analysis as a potential tamper-indicating approach for implementation into FEUM or as a stand-alone method. The project’s primary objectives in FY-15 were to (1) determine detectable tamper scenarios using four pre-amplifier/detector systems, (2) perform tests of tampering scenarios with three common cable types used by the IAEA, (3) separate radio-frequency-induced events from inherent effect by means of an anechoic chamber, and (4) perform tests at an industrial facility. General conclusions were reached in several areas.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Dynamic Response of X-37 Hot Structure Control Surfaces Exposed to Controlled Reverberant Acoustic Excitation

This document represents a compilation of three informal reports from reverberant acoustic tests performed on X-37 hot structure control surfaces in the NASA Langley Research Center Structural Acoustics Loads and Transmission (SALT) facility. The first test was performed on a carbon-silicone carbide flaperon subcomponent on February 24, 2004. The second test was performed on a carbon-carbon ruddervator subcomponent on May 27, 2004. The third test was performed on a carbon-carbon flaperon subcomponent on June 30, 2004.

Grosveld, Ferdinand W.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Technical Requirements for Application of Operator Support Technology across Multiple Plant Systems

Argonne National Laboratory (ANL) and Idaho National Laboratory (INL) are jointly developing and evaluating operator aids to: (i) facilitate more timely response to plant faults and grid disturbances; (ii) achieve better management of plant upsets and improved operator performance; and (iii) ultimately improve nuclear plant safety, production, and cost management. The overall objective of the collaborative effort in this third and final year of the project was to conduct human performance tests using nuclear plant operators in the Human Systems Simulation Laboratory (HSSL) control room at INL to assess the value of a computerized operator support system (COSS) as an aid to the operator. This report describes the work performed by ANL. A companion report describes the work performed by INL and the results of the human performance tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Corrosion Behavior of Steels in Supercritical CO 2 for Power Cycle Applications

In order to understand issues with corrosion of heat exchanger materials in direct supercritical carbon dioxide (sCO 2 ) power cycles, a series of autoclave exposure experiments and electrochemical experiments have been conducted. Corrosion behaviors of 347H stainless steel and P91 martensitic-ferrtic steel in sCO 2 environment have been compared. In autoclave exposure tests performed at 50°C- 245°C and 80 bar. Mass change measurements, surface characterization, and corrosion product analysis have been conducted to understand the corrosion behavior of steels in sCO 2 containing H 2 O and O 2 . Electrochemical tests performed at room temperature and 50°C, a simulation environment of water condensation phase with dissolved CO 2 was prepared to evaluate the corrosion resistance of materials. From both types of experiments, generally 347H showed higher corrosion resistance than P91.

01 COAL, LIGNITE, AND PEAT↗

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Full-Scale Testing of the Ambient Pressure, Acid-Dissolution Front-End Process for the Current Mo-99 Recovery Processes

The Global Threat Reduction Initiative (GTRI) Conversion Program is actively developing technologies for the conversion of civilian facilities using high enriched uranium (HEU) to low enriched uranium (LEU) fuels and targets. The conversion of conventional HEU targets to LEU for 99 Mo production requires approximately five times the uranium in a target to maintain the 99 Mo yield on a per target basis. Under GTRI, Argonne is developing two front-end options for current 99 Mo production processes to allow the use of LEU-foil targets. In both processes, the aim is to produce a front-end product that is compatible with current 99 Mo purification operations and will provide the same or higher yield of 99 Mo for the same number of irradiated targets. The two front-end processes under development as part of this project are (1) the dissolution of irradiated LEU foil (up to 250 g in a single batch) and nickel fission recoil barrier in nitric acid at ambient pressure and (2) the electrochemical dissolution of LEU foil in a series of steps that produces an alkaline (basic) solution feed for 99 Mo purification. This report describes the results of performance tests and design optimization of the ambient pressure, nitric acid dissolver system. The design, fabrication, and performance test planning for this system are described in more detail in previous reports (Jerden et al. 2011a,b, 2012). Full-scale demonstrations of both of the front-end processes using irradiated uranium foils are planned to be performed at Oak Ridge National Laboratory this fiscal year.

Jerden, James↗

X-Ray-Diffraction Tests Of Irradiated Electronic Devices: I

X-ray-diffraction tests performed on aluminum conductors in commercial HI1-507A complementary metal oxide/semiconductor (CMOS) integrated-circuit analog multiplexers, both before and after circuits exposed to ionizing radiation from Co(60) source, and after postirradiation annealing at ambient and elevated temperatures. Tests in addition to electrical tests performed to determine effects of irradiation and of postirradiation annealing on electrical operating characteristics of circuits. Investigators sought to determine whether relationship between effects of irradiation on devices and physical stresses within devices. X-ray diffraction potentially useful for nondestructive measurement of stresses.

Shaw, David C.↗

Low background focal plane array testing in the far infrared

A new long-wavelength infrared test facility is being developed to conduct proof-of-performance tests of focal plane arrays for the Infrared Astronomical Satellite (IRAS) telescope. This facility is believed to be unique in that it will calibrate full-sized arrays designed for the 5-120-micron region of the IR spectrum under simulated spaceflight conditions and at background levels as low as 8 million photons/sq cm-sec. Most of the tests will be performed in a main test chamber which contains a liquid helium shroud, blackbody sources, an arrangement to simulate zodiacal background, and spot scanning optics. A noncontaminating high-vacuum pumping system will be used to evacuate the chamber prior to cool-down to prevent molecular deposition. All housekeeping and focal plane signal outputs are multiplexed, digitized, and transmitted on high-speed data lines to a PDP-11/70 computer. The computer provides real-time displays on a color CRT terminal and stores data for subsequent reduction and hard copy output. An overview of the conceptual design and performance specifications of the test facility are given.

Iufer, E. J.↗

Testing of a Spray-bar Thermodynamic Vent System in Liquid Nitrogen

To support development of a microgravity pressure control capability for liquid oxygen, thermodynamic vent system (TVS) testing was conducted at Marshall Space Flight Center (MSFC) using liquid nitrogen (LN2) as a LOX simulant. The spray bar TVS hardware used was originally designed by the Boeing Company for testing in liquid hydrogen (LH2). With this concept, a small portion of the tank fluid is passed through a Joule-Thomson (J-T) device, and then through a longitudinal spray bar mixed-heat exchanger in order to cool the bulk fluid. To accommodate the larger mass flow rates associated with LN2, the TVS hardware was modified by replacing the recirculation pump with an LN2 compatible pump and replacing the J-T valve. The primary advantage of the spray-bar configuration is that tank pressure control can be achieved independent of liquid and vapor location, enhancing the applicability of ground test data to microgravity conditions. Performance testing revealed that the spray-bar TVS was effective in controlling tank pressure within a 6.89 kPa band for fill levels of 90%, 50%, and 25%. Tests were also conducted with gaseous helium (GHe) in the ullage. The TVS operated nominally with GHe in the ullage, with performance similar to the tests with gaseous nitrogen (GN2). Testing demonstrated that the spray-bar TVS design was flexible enough for use in two different propellants with minimal hardware modifications.

Flachbart, R. H.↗