Fast Track Characterization of Highly Radioactive Waste Pits Combining Off-the-Shelf Robotics with Innovative Investigation Protocols

The investigation and characterization of radioactive waste pits and effluent storage tanks represents a substantial and challenging step in the overall decommissioning programme launched by AREVA NC in 1998 on the site of Marcoule on behalf of the French Atomic Energy commission. Physical ,radiological and regulatory constraints, combined with a tight schedule, have lead our teams to use proven conventional instrumentation and robotics in innovative configurations . One such investigation, conducted on a particularly challenging radioactive effluent storage pit, is described below. The 'H' pit is a stainless steel clad concrete cavity, located in the second basement of the de-cladding building of Marcoule site. It was used for forty years as buffer storage for high activity effluents and has a length of 5 meters, a width of 3 meters , a height of 2.5 meters, and is topped by lead plates over 5 cm thick and The bottom of the cavity is covered with a layer of mud containing mainly graphite, diatoms and resins. The mud level ranges from about 20 centimeters to over 50 centimeters. The overall mud volume is around 2.4 cubic meters. Ambient dose rates above the lead plates exceed 10 mSv/h. The main purpose of our investigation was to characterize the muds for future recovery and conditioning prior to decontaminating the pit. The history of the pit together with the varying mud altimetry lead us to believe that sedimentation had probably occurred throughout the years. We thus decided to combine dose rate measurements using IF104 probes, gamma spectroscopy with CdTe probes and sample collections at different depths to ensure the representativeness and full characterization of the muds. Poor access, ambient dose rates have lead us to conceive a robotic arm, mounted on an shaft which can be modified to fit a wide range of pits and tanks. Custom built robotic tools with maximum manoeuvrability generally involve costs and delays far exceeding our purposes. SIT, a French manufacturer of high precision handling equipment for the nuclear industry, supplied us with a user customized 'Python' Robotic arm and the associated computerized command and control equipment within 6 months of the order. The arm allowed the necessary free movement for a precise characterization of the entire pit while being flexible enough to carry varying measuring and sample collection tools. Investigations included video imaging, precise dimensional checks, collection of effluent samples, gamma spectroscopy and collimated dose rate measurements. Specific tooling and arm extensions were created by SIT for each measurement type. The investigations were conducted successfully, providing a detailed view of the pit condition, a complete mapping of collimated dose rates, a grid of gamma spectroscopy, as well as 8 samples of radioactive mud which were subsequently analyzed in our laboratory . A simple yet innovative technology allowed us to fully characterize this pit and its content within a time frame of less than Eight months We subsequently developed a mud recovery scenario, a process for the conditioning of radioactive muds by cementation, and a complete scenario for the pit decontamination and dismantling. The robotic arm is now being used for the characterization and decontamination of other similar environments on the site of Marcoule.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Degradation Model and Testing Protocol for Metallic Waste Forms

Metallic waste forms developed to immobilize high-level radioactive wastes generated in advanced (closed) fuel cycles are being evaluated as part of the US DOE Fuel Cycle Research and Development program. The electrometallurgical reprocessing of used metallic fuels to recover U and Pu generates two waste streams: salt waste comprised of electro-refiner salt contaminated with oxidized fission products and metallic waste comprised of activated cladding and metallic fission products that were not oxidized under the processing conditions. Metallic waste forms can be made by directly melting the cladding and fuel wastes with small amounts of trim metals to form a multiphase alloy material in which radionuclides and other waste constituents are immobilized within chemically durable intermetallic and iron-based solid solution phases. Some components of the waste streams serve as important constituents of phases comprising the waste form, such as Mo and Zr, which form Fe{sub 2}Mo and Fe{sub 2}Zr intermetallic phases. Other waste constituents are accommodated as substitutional contaminants, such as Tc within the Fe{sub 2}Mo intermetallic and U/TRU within the Fe{sub 2}Zr intermetallic. Sufficient amounts of these host phases must be available to accommodate all radionuclides in the waste stream. The compositional flexibility of the host phases to incorporate waste components is being utilized to formulate metal waste forms that will accommodate variations in waste streams compositions that will occur over long-term fuel reprocessing operations. Small amounts of trim metals can be added to tailor the phase assembly to match the waste stream composition and facilitate waste form processing. For example, additional Zr may be added during waste form production to ensure all U/TRU is sequestered in a durable Fe{sub 2}Zr host phase and trim Cr, Mo, and Ni can be added to supplement the amounts provided by the steel cladding to improve the durability of a metallic waste form. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring the Impact of Experimental Parameters upon the Estimated Thermal Conductivity of Closed-Cell Foam Insulation Subjected to an Accelerated Aging Protocol

The thermal conductivity of many closed-cell foam insulation products changes over time as production gases diffuse out of the cell matrix and atmospheric gases diffuse into the cells. Thin slicing has been shown to be an effective means of accelerating this process in such a way as to produce meaningful results. Recent efforts to produce a more prescriptive version of the ASTM standard test method have led to the initiation of a broad ruggedness test. This test includes the aging of full size insulation specimens for time periods up to five years for later comparison to the predicted results. Experimental parameters under investigation include: slice thickness, slice origin (at the surface or from the core of the slab), thin slice stack composition, product facings, original product thickness, product density, and product type. This paper will cover the structure of the ruggedness test and provide a glimpse of some early trends

42 ENGINEERING↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses on validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring the Impact of Experimental Parameters upon the Estimated Thermal Conductivity of Closed-Cell Foam Insulation Subjected to an Accelerated Aging Protocol ? Two Year Results

The thermal conductivity of many closed-cell foam insulation products changes over time as production gases diffuse out of the cell matrix and atmospheric gases diffuse into the cells. Thin slicing has been shown to be an effective means of accelerating this process in such a way as to produce meaningful results. Efforts to produce a more prescriptive version of the ASTM C 1303 standard test method have led to a broad ruggedness test. This test includes the aging of full size insulation specimens for time periods up to five years for later comparison to the predicted results. Experimental parameters under investigation include: slice thickness, slice origin (at the surface or from the core of the slab), thin slice stack composition, product facings, original product thickness, product density, and product type. This paper will compare the results after two years of full-thickness aging.

42 ENGINEERING↗

Inventing an Energy Internet: Concepts, Architectures and Protocols for Smart Energy Utilization

In recent years, the Internet is revolutionizing information availability much like the Power Grid revolutionized energy availability a century earlier. We will explore the differences and similarities of these two critical infrastructures and identify ways for convergence which may lead to an energy internet. Pricing signals, nodal forecasting, and short-term elasticities are key concepts in smart energy flows respecting the delicate equilibrium involved in generation-demand and aiming at higher efficiencies. We will discuss how intelligent forecasting approaches operating at multiple levels (including device or nodal levels) can ameliorate the challenges of power storage. In addition to higher efficiencies, an energy internet may achieve significant reliability and security improvements and offer greater flexibility and transparency in the overall energy-environmental relation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures: January 2012 - September 2016

This is the complete set of Uniform Methods Project protocols for determining energy efficiency savings for specific measures, all within one report. The report includes the following chapters: Chapter 1: Introduction. Chapter 2: Commercial and Industrial Lighting Evaluation Protocol. Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. Chapter 4: Small Commercial and Residential Unitary and Split System HVAC Cooling Equipment-Efficiency Upgrade Evaluation Protocol. Chapter 5: Residential Furnaces and Boilers Evaluation Protocol. Chapter 6: Residential Lighting Evaluation Protocol. Chapter 7: Refrigerator Recycling Evaluation Protocol. Chapter 8: Whole-Building Retrofit with Consumption Data Analysis Evaluation Protocol. Chapter 9: Metering Cross-Cutting Protocol. Chapter 10: Peak Demand and Time-Differentiated Energy Savings Cross-Cutting Protocol. Chapter 11: Sample Design Cross-Cutting Protocol. Chapter 12: Survey Design and Implementation for Estimating Gross Savings Cross-Cutting Protocol. Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. Chapter 14: Chiller Evaluation Protocol. Chapter 15: Commercial New Construction Evaluation Protocol. Chapter 16: Retrocommissioning Evaluation Protocol. Chapter 17: Residential Behavior Evaluation Protocol. Chapter 18: Variable Frequency Drive Evaluation Protocol. Chapter 19: HVAC Controls (DDC/EMS/BAS) Evaluation Protocol. Chapter 20: Data. Center IT Efficiency Measures Evaluation Protocol. Chapter 21: Estimating Net Savings - Common Practices. Chapter 22: Compressed Air Evaluation Protocol. Chapter 23: Combined Heat and Power Evaluation Protocol. Chapter 24: Strategic Energy Management (SEM) Evaluation Protocol

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Repopulation of interacting tumor cells during fractionated radiotherapy: Stochastic modeling of the tumor control probability

Purpose: Optimal treatment planning for fractionated external beam radiation therapy requires inputs from radiobiology based on recent thinking about the “five Rs” (repopulation, radiosensitivity, reoxygenation, redistribution, and repair). The need is especially acute for the newer, often individualized, protocols made feasible by progress in image guided radiation therapy and dose conformity. Current stochastic tumor control probability (TCP) models incorporating tumor repopulation effects consider “stem-like cancer cells” (SLCC) to be independent, but the authors here propose that SLCC-SLCC interactions may be significant. The authors present a new stochastic TCP model for repopulating SLCC interacting within microenvironmental niches. Our approach is meant mainly for comparing similar protocols. It aims at practical generalizations of previous mathematical models. Methods: The authors consider protocols with complete sublethal damage repair between fractions. The authors use customized open-source software and recent mathematical approaches from stochastic process theory for calculating the time-dependent SLCC number and thereby estimating SLCC eradication probabilities. As specific numerical examples, the authors consider predicted TCP results for a 2 Gy per fraction, 60 Gy protocol compared to 64 Gy protocols involving early or late boosts in a limited volume to some fractions. Results: In sample calculations with linear quadratic parameters α = 0.3 per Gy, α/β = 10 Gy, boosting is predicted to raise TCP from a dismal 14.5% observed in some older protocols for advanced NSCLC to above 70%. This prediction is robust as regards: (a) the assumed values of parameters other than α and (b) the choice of models for intraniche SLCC-SLCC interactions. However, α = 0.03 per Gy leads to a prediction of almost no improvement when boosting. Conclusions: The predicted efficacy of moderate boosts depends sensitively on α. Presumably, the larger values of α are the ones appropriate for individualized treatment protocols, with the smaller values relevant only to protocols for a heterogeneous patient population. On that assumption, boosting is predicted to be highly effective. Front boosting, apart from practical advantages and a possible advantage as regards iatrogenic second cancers, also probably gives a slightly higher TCP than back boosting. If the total number of SLCC at the start of treatment can be measured even roughly, it will provide a highly sensitive way of discriminating between various models and parameter choices. Updated mathematical methods for calculating repopulation allow credible generalizations of earlier results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Characterization Test of a Grid-Forming Inverter for Microgrid Applications

Standardized experimental testing protocols for grid forming (GFM) inverters to ensure expected operation under both normal and contingency conditions do not exist. Such protocols increase the confidence of system owner/operators that an inverter deployed in a proposed system will engage in typical behaviors to ensure interoperability with other units and ancillary equipment (e.g. protection equipment). This paper presents systematic and comprehensive test protocols to evaluate the performance of GFM inverters under the following operational configurations: islanded operation, heterogeneous islanded operation (parallel with a synchronous generator), grid-connected operation, and transition operation. A commercial GFM inverter is used to verify the test protocols and to understand the inverter's performance and functionalities. In particular, required configuration and tuning of the inverter will be explained in the full paper to enrich the testing protocol.

black start↗