Search NASA⌕ Search

SEARCH · Search NASA

Results for “quality monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Annual Site Environmental Report: 2023 (ASER) for the SLAC National Accelerator Laboratory

This report, prepared by the SLAC National Accelerator Laboratory (SLAC) for the U.S. Department of Energy (DOE), SLAC Site Office (SSO), provides a comprehensive summary of the environmental program activities at SLAC for calendar year 2023. Annual Site Environmental Reports (ASERs) are prepared for all DOE sites with significant environmental activities and distributed to relevant external regulatory agencies and other interested organizations or individuals. To the best of my knowledge, this report accurately summarizes the results of the 2023 environmental monitoring, compliance, and restoration programs at SLAC. This assurance can be made based on SSO and SLAC review of the ASER, and quality assurance protocols applied to monitoring and data analyses at SLAC.

54 ENVIRONMENTAL SCIENCES↗

Annual Site Environmental Report: 2021 (ASER) for the SLAC National Accelerator Laboratory

This report, prepared by the SLAC National Accelerator Laboratory (SLAC) for the U.S. Department of Energy (DOE), SLAC Site Office (SSO), provides a comprehensive summary of the environmental program activities at SLAC for calendar year 2021. Annual Site Environmental Reports (ASERs) are prepared for all DOE sites with significant environmental activities and distributed to relevant external regulatory agencies and other interested organizations or individuals. To the best of my knowledge, this report accurately summarizes the results of the 2021 environmental monitoring, compliance, and restoration programs at SLAC. This assurance can be made based on SSO and SLAC review of the ASER, and quality assurance protocols applied to monitoring and data analyses at SLAC.

54 ENVIRONMENTAL SCIENCES↗

Applying Web-Based Tools for Research, Engineering, and Operations

Personnel in the NASA Glenn Research Center Network and Architectures branch have performed a variety of research related to space-based sensor webs, network centric operations, security and delay tolerant networking (DTN). Quality documentation and communications, real-time monitoring and information dissemination are critical in order to perform quality research while maintaining low cost and utilizing multiple remote systems. This has been accomplished using a variety of Internet technologies often operating simultaneously. This paper describes important features of various technologies and provides a number of real-world examples of how combining Internet technologies can enable a virtual team to act efficiently as one unit to perform advanced research in operational systems. Finally, real and potential abuses of power and manipulation of information and information access is addressed.

Ivancic, William D.↗

Rapid Analysis, Self-Calibrating Array for Air Monitoring

Human space missions have critical needs for monitoring and control for life support systems. These systems have monitoring needs that include feedback for closed loop processes and quality control for environmental factors. Sensors and monitoring technologies assure that the air environment and water supply for the astronaut crew habitat fall within acceptable limits, and that the life support system is functioning properly and efficiently. The longer the flight duration and the more distant the destination, the more critical it becomes to have carefully monitored and automated control systems for life support. Past experiments with the JPL ENose have demonstrated a lifetime of the sensor array, with the software, of around 18 months. The lifetime of the calibration, for some analytes, was as long as 24 months. We are working on a sensor array and new algorithms that will include sensor response time in the analysis. The preliminary array analysis for two analytes shows that the analysis time, of an event, can be dropped from 45 minutes to less than10 minutes and array training time can be cut substantially. We will describe the lifetime testing of an array and show lifetime data on individual sensors. This progress will lead to more rapid identification of analytes, and faster training time of the array.

Self Calibrating↗

Dry anaerobic digestion of cow manure and agricultural products in a full-scale plant: Efficiency and comparison with wet fermentation

Highlights: • The first full-scale, agricultural dry fermentation plant of Italy was monitored. • Recirculation rate, leachate, biogas and energy production were monitored. • Dry fermentation showed biogas yields similar to wet. • Retention time, recirculation of digestate and leachate are key factors. • Plant operation required significant man labor (loading and unloading of reactors). - Abstract: For years, anaerobic digestion processes have been implemented for the management of organic wastes, agricultural residues, and animal manure. Wet anaerobic digestion still represents the most common technology, while dry fermentation, dedicated to the treatment of solid inputs (TS > 20%) can be considered as an emerging technology, not in terms of technological maturity, but of diffusion. The first agricultural dry anaerobic digestion plant constructed in Italy was monitored from the start-up, for over a year. The plant was fed with manure and agricultural products, such as corn silage, triticale, ryegrass, alfalfa, and straw. Three Combined Heat and Power units, for a total installed power of 910 kW{sub e}, converted biogas into thermal and electric energy. The monitoring included the determination of quality and quantity of input feedstocks, of digestate (including recirculation rate), of leachate, biogas quality (CH{sub 4}, CO{sub 2}, H{sub 2}S), biogas yield, energy production, labor requirement for loading, and unloading operations. The results of the monitoring were compared to performance data obtained in several full scale wet digestion plants. The dry fermentation plant revealed a start-up phase that lasted several months, during which the average power resulted in 641 kW{sub e} (70.4% of nominal power), and the last period the power resulted in 788 kW{sub e} (86.6% of installed power). Improving the balance of the input, the dry fermentation process demonstrated biogas yields similar to wet anaerobic digestion, congruent to the energy potential of the biomasses used in the process. Furthermore, the operation of the plant required significant man labor, mainly related to loading and unloading of the anaerobic cells.

09 BIOMASS FUELS↗

Preliminary Evaluation of Thematic Mapper Image Data Quality

Improvements in the ability to monitor renewable resources/vegegation due to improvements in the spatial, spectral and radiometric resolution of TM data were evaluated. Results presented from the first 4 months of analysis presented include: (1) geometric performance; (2) band-to-band registration; (3) modulation transfer function; and (4) crop separabililty performance. Crop separability in Webster County, Iowa and in Mississippi County, Arkansas as determined by cluster and principal components analyses is assessed.

Macdonald, R. B.↗

Crack Detection for Aerospace Quality Spur Gears

Health and Usage Monitoring System research and development involves analysis of the vibration signals produced by a gearbox throughout its life. There are two major advantages of knowing the actual lifetime of a gearbox component: safety and cost. In this report, a technique is proposed to help extract the critical data and present it in a manner that can be easy to understand. The key feature of the technique is to make it independent of speed, torque and prior history for localized, single tooth damage such as gear cracks. This extraction technique is demonstrated on two sets of digitized vibration data from cracked spur gears. Standard vibration diagnostic parameters are calculated and presented for comparison. Several new detection algorithms are also presented. The results of this study indicate that crack detection methods examined are not robust or repeatable. The proposed techniques provide a limited improvement to existing diagnostic parameters. Current techniques show that the cracks progressed at a much faster rate than anticipated which reduced available time for detection.

Decker, Harry J.↗

The Continuous Monitoring of Desert Dust using an Infrared-based Dust Detection and Retrieval Method

Airborne dust and sand are significant aerosol sources that can impact the atmospheric and surface radiation budgets. Because airborne dust affects visibility and air quality, it is desirable to monitor the location and concentrations of this aerosol for transportation and public health. Although aerosol retrievals have been derived for many years using visible and near-infrared reflectance measurements from satellites, the detection and quantification of dust from these channels is problematic over bright surfaces, or when dust concentrations are large. In addition, aerosol retrievals from polar orbiting satellites lack the ability to monitor the progression and sources of dust storms. As a complement to current aerosol dust retrieval algorithms, multi-spectral thermal infrared (8-12 micron) data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Meteosat-8 Spinning Enhanced Visible and Infrared Imager (SEVIRI) are used in the development of a prototype dust detection method and dust property retrieval that can monitor the progress of Saharan dust fields continuously, both night and day. The dust detection method is incorporated into the processing of CERES (Clouds and the Earth s Radiant Energy System) aerosol retrievals to produce dust property retrievals. Both MODIS (from Terra and Aqua) and SEVERI data are used to develop the method.

Duda, David P.↗

DOE Basic Overview of Occupational Radiation Exposure 2011 (Pamphlet)

This pamphlet focusses on two HSS activities that help ensure radiation exposures are accurately assessed and recorded, namely: 1) the quality and accuracy of occupational radiation exposure monitoring, and 2) the recording, reporting, analysis, and dissemination of the monitoring results. It is intended to provide a short summary of two specific HSS programs that aid in the oversight of radiation protection activities at DOE. The Department of Energy Laboratory Accreditation Program (DOELAP) is in place to ensure that radiation exposure monitoring at all DOE sites is precise and accurate, and conforms to national and international performance and quality assurance standards. The DOE Radiation Exposure Monitoring Systems (REMS) program provides for the collection, analysis, and dissemination of occupational radiation exposure information. The annual REMS report is a valuable tool for managing radiological safety programs and for developing policies to protect individuals from occupational exposure to radiation. In tandem, these programs provide DOE management and workers an assurance that occupational radiation exposures are accurately measured, analyzed, and reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultrasonic Inspection During Autoclave Cure of Reflowable-Interface Composite Joints

In structural bonds, the interface between adherend and adhesive is nearly two-dimensional making the interface susceptible to minute quantities of contamination, which can cause weak bonds. Regulatory organizations such as the Federal Aviation Administration (FAA) often require redundant load paths in secondary-bonded primary-structures due to uncertainty in bond performance. To address this issue, the NASA Convergent Aeronautics Solutions (CAS): Adhesive Free Bonding of Composites (AERoBOND) project is investigating reformulated aerospace epoxy-matrix resins to enable reflow and diffusion of the resin at the joint interface during a secondary bonding and cure process that can eliminate the material discontinuity at the interface. Implementing in-situ process monitoring enables assessing the bond quality during processing rather than waiting for post-fabrication mechanical testing to be completed. In this paper, an in-situ ultrasonic inspection system is used to monitor the joining of three composite laminates assembled using the AERoBOND technique. For each panel, the amplitude of the wave reflection at the joint was measured throughout the cure cycle. The results indicate the timing and extent of reflow and cure of the epoxy resin at the joint. Factors indicating end of cure were ascertained and a metric was developed to qualitatively predict acceptable mode-II fracture toughness based on the ultrasonic amplitude at the joint line during cure. In addition, since the inspection system scans an area of the joint, high-resolution localized results can be obtained across the joint.

Tyler B Hudson↗

Using taxa-based approaches to delineate stream macroinvertebrate assemblage responses to stressor gradients in modified alluvial agroecosystems

Alluvial plain landscapes are some of the most agriculturally productive lands in the world but often have modified stream ecosystems due to cultivation history. This context requires consideration when establishing water quality management goals. We analyzed state water quality databases to demonstrate that Mississippi Alluvial Plain (MAP) ecoregion streams have elevated specific conductivity (SC) and nutrients and lower macroinvertebrate local and regional taxa pools compared to streams in other ecoregions, potentially reducing the efficacy of traditional biomonitoring approaches within the region. To overcome these challenges, we used threshold indicator taxa analysis (TITAN) to compare macroinvertebrate assemblage responses to water quality gradients among ecoregions in Mississippi. We identified individual taxa and assemblage-level responses to increasing water quality degradation in MAP streams. Observed responses occurred at higher concentrations for SC, total organic carbon (TOC) and total phosphorus (TP), but not total nitrogen (TN) relative to other ecoregions. These responses appeared to be driven by a large proportion of indicator taxa considered tolerant or unresponsive in other ecoregions, responding negatively to increasing water quality stressors in MAP streams. Our observed assemblage-level stressor responses to WQ gradients in MAP streams demonstrate shifting tolerance in highly altered ecosystems may require adjustments to recovery expectations but also provide useful measures for monitoring improvements in regional water quality. For example, our observed macroinvertebrate assemblage response to increasing TP identified a management goal similar to guidance based on distributional analysis of water quality data within the MAP ecoregion (0.11 vs 0.128 mg L –1 ) and thus provide some biological basis for previously identified nutrient goals for the region. Our approach can guide and monitor success of nutrient reduction efforts in MAP watersheds and other alluvial plain agroecosystems where reference conditions do not exist, and local and regional taxa pools are less diverse and may not support full recovery of ecological assemblages. While our results are promising, they should also be compared with more sensitive and less habitat-limited biological assemblages (e.g., algae or bacteria) to better understand complex ecological responses to best management practices designed to increase sustainability of high production agricultural regions.

59 BASIC BIOLOGICAL SCIENCES↗

SU-G-JeP4-13: Continuous Intra-Fractional Monitoring of the Prostate Using Dynamic KV Collimation and Tube Current Modulation

Purpose: The focus of this work is to improve the available kV image quality for continuous intra-fraction monitoring of the prostate. This is investigated using a novel blade collimation system enabling modulated volume-of-interest (VOI) imaging of prostate fiducial markers. Methods: A four-blade dynamic kV collimator was used to track a VOI during gantry rotation. Planar image quality was investigated as a function of collimator dimension, while maintaining the same dose to isocenter, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert. A sample prostate anatomy was defined in the planning system, including three fiducial markers within the CTV. The VOI margin around each marker was set to be 2σ of the population covariance matrix characterizing prostate motion. DRRs were used to calculate the kV attenuation for each VOI as a function of angle. The optimal marker and tube current were determined using kV attenuation. Monte Carlo simulations were used to calculate the imaging dose to the phantom and MV scatter dose to the imaging panel. Results: Preliminary measurements show an increase in CNR by a factor of 1.3 with the VOI method, when decreasing from an 6×6 to 2×2 cm{sup 2} field. Attenuation calculations show a change in kV fluence at the detector by a factor of 21.6 with fiducial optimization; resultant tube current modulation increases maximum dose by a factor of 1.4 compared to no modulation. MV scatter contribution to the kV detector changes by approximately a factor of two over a complete gantry rotation. Conclusion: The dynamic collimation system allows single fiducial marker tracking at a very low dose, with reduction of scatter and improvement of image quality, compared to imaging the entire prostate. The approach is compatible with tube current modulation, which enables consistent image quality throughout the range of gantry rotation. This project was funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Online and Offline Monitoring of the ICARUS Detector

In preparation for the launch of the ICARUS -T600 far detector in the Short Baseline Neutrino program, (SBN), it is important to monitor the performance of the detector and quality of the data in real-time. Particularly important to monitor are noise levels of the TPC readout electronics, and the purity of the liquid argon in the TPC, as these can affect the overall sensitivity of the detector to detecting and reconstructing neutrino interactions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of test for quality assurance in nuclear medicine gamma camera

In nuclear medicine (NM) over 90% of procedures are performed for diagnostic purposes. To ensure adequate diagnostic quality of images and the optimization of the doses received by patients originated from the radioactive material is essential for regular monitoring and equipment performance through a quality assurance program (QAP). The QAP consists of 15 proposed performance tomographic and not tomographic gamma camera (GC) tests, and is based on recommendations of international organizations. We describe some results of the performance parameters of QAP applied to a GC model e.cam Siemens, of the Department of NM of the National Cancer Institute of Mexico (INCan). The results were: (1) The average intrinsic spatial resolution (R{sub in}) was 4.67 {+-} 0.25 mm at the limit of acceptance criterion of 4.4 mm. (2) The sensitivity extrinsic (S{sub ext}), with maximum variations of 1.8% (less than 2% which is the criterion of acceptance). (3) Rotational Uniformity (U{sub rot}), with values of integral uniformity (IU) in the useful field of view detector (UFOV), with maximum percentage change of 0.97% and monthly variations equal angles, ranging from 0.13 to 0.99% less than 1%. (4) The displacement of the center of rotation (DCOR), indicated a maximum deviation of 0.155 {+-} 0.039 mm less than 4.795 mm, an absolute deviation of less than 0.5 where pixel 0.085 pixel is suggested, the criteria are assigned to low-energy collimator high resolution. (5) In tomographic uniformity (U{sub tomo}), UI values (%) and percentage noise level (rms%) were 7.54 {+-} 1.53 and 4.18 {+-} 1.69 which are consistent with the limits of acceptance of 7.0-12.0% and 3.0-6.0% respectively. The smallest cold sphere has a diameter of 11.4 mm. The implementation of a QAP allows for high quality diagnostic images, optimization of the doses given to patients, a reduction of exposure to occupationally exposed workers (POE, by its Spanish acronym), and generally improves the productivity of the service. This proposal can be used to develop a similar QAP in other facilities and may serve as a precedent for the proposed regulations for quality assurance (QA) teams in MN.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Emission Spectroscopy as an in Situ Diagnostic Tool for X-ray Crystallography of Metalloproteins Using an X-ray Free-Electron Laser

Serial femtosecond crystallography (SFX) using the ultrashort X-ray pulses from a X-ray free-electron laser (XFEL) provides a new way of collecting structural data at room temperature that allows for following the reaction in real time after initiation. XFEL experiments are conducted in a shot-by-shot mode as the sample is destroyed and replenished after each X-ray pulse, and therefore, monitoring and controlling the data quality by using in situ diagnostic tools is critical. To study metalloenzymes, we developed the use of simultaneous collection of X-ray diffraction of crystals along with X-ray emission spectroscopy (XES) data that is used as a diagnostic tool for crystallography, by monitoring the chemical state of the metal catalytic center. We have optimized data analysis methods and sample delivery techniques for fast and active feedback to ensure the quality of each batch of samples and the turnover of the catalytic reaction caused by reaction triggering methods. Here, we describe this active in situ feedback system using Photosystem II as an example that catalyzes the oxidation of H2O to O2at the Mn4CaO5active site. We used the first moments of the Mn Kβ1,3emission spectra, which are sensitive to the oxidation state of Mn, as the primary diagnostics. This approach is applicable to different metalloproteins to determine the integrity of samples and follow changes in the chemical states of the reaction that can be initiated by light or activated by substrates and offers a metric for determining the diffraction images that are used for the final data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Meandering Winding Magnetometer (MWM (Register Trademark)) Eddy Current Sensors for the Health Monitoring, Modeling and Damage Detection of High Temperature Composite Materials

The increased use of high-temperature composite materials in modern and next generation aircraft and spacecraft have led to the need for improved nondestructive evaluation and health monitoring techniques. Such technologies are desirable to improve quality control, damage detection, stress evaluation and temperature measurement capabilities. Novel eddy current sensors and sensor arrays, such as Meandering Winding Magnetometers (MWMs) have provided alternate or complimentary techniques to ultrasound and thermography for both nondestructive evaluation (NDE) and structural health monitoring (SHM). This includes imaging of composite material quality, damage detection and .the monitoring of fiber temperatures and multidirectional stresses. Historically, implementation of MWM technology for the inspection of the Space Shuttle Orbiter Reinforced Carbon-Carbon Composite (RCC) leading edge panels was developed by JENTEK Sensors and was subsequently transitioned by NASA as an operational pre and post flight in-situ inspection at the Kennedy Space Center. A manual scanner, which conformed'automatically to the curvature of the RCC panels was developed and used as a secondary technique if a defect was found during an infrared thermography screening, During a recent proof of concept study on composite overwrapped pressure vessels (COPV's), three different MWM sensors were tested at three orientations to demonstrate the ability of the technology to measure stresses at various fiber orientations and depths. These results showed excellent correlation with actual surface strain gage measurements. Recent advancements of this technology have been made applying MWM sensor technology for scanning COPVs for mechanical damage. This presentation will outline the recent advance~ in the MWM.technology and the development of MWM techniques for NDE and SHM of carbon wra~ped composite overwrapped pressure vessels (COPVs) including the measurement of internal stresses via a surface mounted sensor array. In addition, this paper will outline recent efforts to produce sensors capable of making real-time measurements at temperatures up to 850 C, and discuss previous results demonstrating capability to monitor carbon fiber temperature changes within a composite material.

Russell, Richard↗

GEOS-Carb III: Delivering Mature Carbon Flux and Concentration Datasets in Support of NASA's Carbon Monitoring System

The GEOS-Carb project seeks to make high quality, data-driven products that support NASA's Carbon Monitoring System Program. These include bottom-up land and ocean flux estimates along with fossil fuel emissions, all informed by satellite data and the MERRA-2 reanalysis. These flux data support atmospheric carbon products that include both simulations and data assimilation products. We show examples of this work and discuss applications to future mission planning.

Ott, L.↗