Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Carbon Capture, Utilization, & Storage (CCUS) in Achieving a Net Zero Emissions Future - System Cost of Replacement Energy (SCoRE): A Tool for Assessing Technology Substitution Pathways to Decarbonization

This presentation outlines the SCoRE tool, which can be used to identify the least-cost technology substitution pathway to meeting a decarbonization target within an operating region of the United States. The presentation showcases results from an application of the tool in the ERCOT operating region.

Harker-Steele, Amanda↗

Why Lady Godiva Should be Replaced as the Default Validation Experiment for U-235 Nuclear Data

For the past seven decades the Lady Godiva benchmark (HEU-MET-FAST-001) has been the primary experiment used for 235 U nuclear data validation. The papers associated with large nuclear data library releases such as ENDF/B-VII.1 and ENDF/B-VIII.0 refer to it frequently. The reasons why HEU-MET-FAST-001 has been used as the primary validation experiment for 235 U nuclear data validation will be discussed in the following section. However, as discussed among the benchmark community, the standards associated with International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations have changed throughout time; this is subject of the OECD/NEA WPEC (Working Party on Nuclear Criticality Safety) Subgroup 8. HEU-MET-FAST-001 is an older benchmark (issued during the inaugural year of ICSBEP in 1996 with only minor revisions occurring since then) and (along with many of the other benchmarks from this era) does not meet the standards for a modern benchmark. This work explores why HEU-MET-FAST-001 is useful for 235 U nuclear data validation and discusses other alternative validation experiments.

07 ISOTOPE AND RADIATION SOURCES↗

Bioderived monomers as replacements in petroleum based polymers and copolymers

The present disclosure relates to a composition that includes a first repeat unit that includes where x is between 1 and 1,000, inclusively, and R1 includes at least one of a first hydrocarbon chain and/or a first hydrocarbon ring. In some embodiments of the present disclosure, R1 may further include at least one of an oxygen atom, a nitrogen atom, a sulfur atom, and/or a phosphorus atom.

Hoyt, Caroline Bradshaw↗

Black Bear Prep plant replaces high-frequency screens with fine wire sieves

At the Black Bear prep plant (near Wharncliffe, WV, USA) the clean coal from the spirals traditionally reported to high-frequency screens, which removed high-ash clay fines. Screens have inherent inefficiencies that allow clean coal to report to the screen underflow. The goal of this project was to capture the maximum amount of spiral clean coal while still removing the high-ash clay material found in the spiral product. The reduction of the circulating load and plant downtime for unscheduled maintenance were projected as additional benefits. After the plant upgrade, the maintenance related to the high frequency screens was eliminated and an additional 2.27 tons per hour (tph) of fine coal was recovered, which resulted in a payback period of less than one year. The article was adapted from a paper presented at Coal Prep 2007 in April 2007, Lexington, KY, USA. 1 ref., 1 fig., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Bearing repair services offer a cost-effective alternative to expensive replacement

The article, based on a presentation during MINExpo 2008, explains how advancement is bearing design, material, maintenance and repair methods have greatly improved the potential for and popularity of bearing repair as an effective way to extend bearing life. The Trinken Co. offers a variety of service options including repair, recertification, reconditioning and remanufacturing. Benefits of a quality repair program are outlined. 2 photos.

01 COAL, LIGNITE, AND PEAT↗

300 GPM Solids Removal System A True Replacement for Back Flushable Powdered Filter Systems - 13607

The EnergySolutions Solids Removal System (SRS) utilizes stainless steel cross-flow ultra-filtration (XUF) technology which allows it to reliably remove suspended solids greater than one (1) micron from liquid radwaste streams. The SRS is designed as a pre-treatment step for solids separation prior to processing through other technologies such as Ion Exchange Resin (IER) and/or Reverse Osmosis (RO), etc. Utilizing this pre-treatment approach ensures successful production of reactor grade water while 1) decreasing the amount of radioactive water being discharged to the environment; and 2) decreasing the amount of radioactive waste that must ultimately be disposed of due to the elimination of spent powdered filter media. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reactive transport modeling and characterization of concrete materials with fly ash replacement under carbonation attack - 15477

There currently lacks sufficient knowledge to accurately characterize structural, hydraulic, and chemical performance of cementitious materials that are required to contain and shield nuclear waste for thousands of years. There are a number of degradation methods that can affect the integrity of these materials over this time frame including carbonation which lowers the alkalinity of the material and can induce cracking in materials with steel reinforcement. The rate and extent of carbonation in these materials is impacted by the addition of fly ash and its composition which can vary depending on the fly ash source. To characterize the carbonation reaction, the changes in the microstructure and elemental distribution as a function of extent of carbonation and fly ash type were evaluated using scanning electron microscopy (SEM) coupled with energy dispersive x-ray spectroscopy (EDS). Micro-concretes were prepared with no fly ash (control case) and with fly ash of various calcium compositions. The progression of the carbonation front was observed in the backscattered electron images by the formation of calcium carbonate and depth was confirmed with a phenolphthalein pH indicator test. The migration and deposition of chemical species were observed in carbonated regions from EDS data and were explained based on the changes in material alkalinity and solubility determined from EPA Method 1313 (Liquid-solid partitioning (LSP) as a function of eluate pH). The changes in mass transport properties from carbonation were observed using EPA Method 1315 (Mass transfer rates in monolithic and compacted granular materials using semi-dynamic tank leaching procedures). The carbonation reaction in each material was simulated using LeachXS/ORCHESTRA, a reactive transport modeling tool, which provided further evidence of localized deposition and migration of chemical species due to changes in speciation and solubility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

How to Replace Co-60 Tracer when Faced with Unknown Variability of Initial Cobalt Content - 18059

Electricite de France (EDF), radioactive waste producer, is responsible for managing waste from dismantling of its permanently shut-down nuclear power plants. The process has been opened for more than 10 years for some plants of the first generation and is under preparation for the first pressurized water reactor (PWR) plants to be dismantled. Nowadays it is generally admitted that waste disposal is the main constraint of dismantling. In France, waste producer is required by safety rules to obtain an agreement from French governmental agency (ANDRA) before any waste production and for each type of waste under project. Such an agreement which is a technical file, is the proof that the container, the way of waste conditioning, waste composition itself and especially the activity of each radionuclide (RN), comply with all the requirements of the disposal safety studies. We should also notice in French regulation that the declaration process of activities i.e. the way the radiological content of each container is computed and declared is a prerequisite to its disposal shipment. Taking into account that EDF has already prepared numerous files describing the means to fill the container itself, the main problem to cope with now is the declaration of each RN which is present in each container ready to be shipped to the disposal. The paper points out the general case of Difficult- To-Measure (DTM) radionuclide management and specially the high difference between waste from plants in operation and waste from dismantling plants. Starting from a '3D' neutron flux cartography computation at 100% power, a specific global strategy of DTM activation RN evaluation for each type of waste has been developed. As the only tracer is Co- 60, which is almost always the case in EDF dismantling, the way to compute the global scaling factors of mix of different waste initial composition is easy when the cobalt initial composition (before irradiation by neutrons) is known. But, in some cases, cobalt is not included in the steel composition required for conception purposes but only considered as an impurity which maximum quantity is known. The result is that, even for a given family of waste corresponding to the same object for dismantling, the tracer value variability is not any more correlated with the irradiation level of the activated waste, which is completely spoiling any of its tracer property. The more the cobalt level variability is high, the more the necessary conservative choice of minimum cobalt level to compute the activation scaling factor will lead to an important overestimation of DTM RN using these scaling factor with respect to Co-60. The paper describes a method using residual thermal power measurement and removing computed Co-60 residual thermal power with the help of gamma measurement to give a new tracer without any chaotic behavior. The possible application is studied on interim storage of irradiated graphite sleeves mixed with stainless steel wires. This method avoids overestimation of graphite inventories coming from activation by neutron flux and using scaling factors with respect to any failing gamma tracer. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Normetex Replacement Development

Outline • Background • Previous development efforts • Air Squared redesign • Non-scroll alternatives • Pump performance • Pump performance comparison • Test system overhaul • Conclusions

Angelette, Lucas M. [Savannah River National Labor↗