SEARCH · Search NASA
Results for “sample minimization”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Small Particle Glovebox Experiments - Preliminary Results
A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.
Spherical fused silica cells filled with pure helium for nuclear magnetic resonance-magnetometry
High magnetic fields (>1 T) are measured by NMR magnetometers with unrivaled precision if the precessing spin sample provides long coherence times. The longest coherence times are found in diluted {sup 3}He samples, which can be hyperpolarized for sufficient signal strength. In order to have minimal influence on the homogeneity and value of the measured magnetic field, the optimal container for the {sup 3}He should be a perfect sphere. A fused silica sphere with an inner diameter of 8 mm and an outer diameter of 12 mm was made from two hemispheres by diffusion bonding leaving only a small hole for cleaning and evacuation. This hole was closed in vacuum by a CO{sub 2} laser and the inner volume was filled with a few mbars of {sup 3}He via wall permeation. NMR-measurements on such a sample had coherence times of 5 min. While the hemispheres were produced with <1 μm deviation from sphericity, the bonding left a step of ca. 50 μm at maximum. The influence of such a mismatch, its orientation, and the immediate environment of the sample is analyzed by FEM-simulations and discussed in view of coherence times and absolute field measurements.
Paramagnetic shimming for high-field MRI
The diamagnetism of biological tissues reduces the homogeneity of the magnetic field and may limit the number of samples in multi-sample gradient-recalled echo (GRE) experiments. This study aims to (1) evaluate the magnetic field distortions and signal loss artifacts in GRE images of proximal water samples, and (2) develop a passive shimming device to overcome this limitation. The magnetic field distribution produced by a diamagnetic H{sub 2}O sphere and a paramagnetic CuSO{sub 4} disk in a secondary phantom were mapped using GRE experiments and the phase reference method, and compared to the corresponding magnetostatics models. The water sphere produced a pronounced signal loss artifact in amplitude images. This artifact was significantly reduced when the paramagnetic disk was placed symmetrically between the water sphere and the secondary spherical phantom. The present study suggests that the use of paramagnetic shimming devices can help to minimize susceptibility-related MRI signal losses and to increase the number of samples in multi-sample MRI experiments. The volume susceptibility and the shape of paramagnetic shimming devices could be optimized for particular setups and samples accordingly.
Initiation Thresholds and Dynamic Characteristics of an Explosion for Thin Samples of PETN-Al Composites under Laser Irradiation
In this paper, we measured thresholds H{sub cr} of explosive decomposition of thin (h = 1 mm) samples of PETN-Al composites with densities in the range of ρ = 0.9–1.7 g/cm{sup 3} and variations in the concentration of aluminum inclusions in the range of 0.025–1.0 wt % upon exposure to pulses of a neodymium laser (λ = 1064 nm, 14 ns). For each ρ, inclusion concentrations n{sub opt}, at which the threshold for explosive decomposition of H{sub cr} is minimal, are obtained. The velocities of air shock waves (ASWs) were determined depending on sample density ρ, and the times of the start of explosive decomposition were determined depending on the inclusion concentration. The amplitude (in relative units) and time shift of the maximal pressure of an ASW at the piezodetector are determined depending on sample density. It is concluded that the explosion is governed by the SW mechanism at high densities. As sample ρ decreases, the completeness of the explosion increases, with the most likely mechanism for small ρ being explosive burning. The efficiency of explosive decomposition is higher for samples with lower densities.
Novel High Temperature and Radiation Resistant Infrared Glasses and Optical Fibers for Sensing in Advanced Small Modular Reactors
One binary and three series of ternary non-oxide pure sulfide glasses compositions were investigated with the goal of synthesizing new glasses that exhibit high glass transition (Tg) and crystallization (Tc) temperatures, infrared transparency, and reliable glass formability. The binary glass series consisted of Ges 2 and La 2 S 3 and the three glass series in the x(nBaS + mLa2S3) + (1-2x)GeS2 ternary system have BaS:La2S3 modifier ratios of 1:1, 1:2, and 2:1 with . With these glasses, new insights were realized as to how ionic glasses form and how glass modifiers affect both structure and glass formability. All synthesized compositions were characterized by Infrared (IR) and Raman spectroscopies and differential thermal analysis (DTA) to better understand the fundamental structure, optical, and thermal characteristics of the glasses. After a range of these glasses were synthesized, optimal compositions were formed into glass disks and subjected to gamma irradiation. Glass disks were characterized both before and after irradiation by microscope imaging, measuring the refractive index, density, and UV-VIS-IR transmission spectra. The final total dose the samples were subjected to was ~2.5 MGy. Ternary samples showed a less than 0.4% change in density and refractive index and minimal change in transmission window. The glasses also resisted cracking as seen in microscope images. Overall, many glass compositions were developed that possess operating temperatures above 500 °C, where conventional chalcogenide glasses such as As2S3 and have T g s from ~200-300 °C, and these glasses have a greater than Tc – Tg values larger than 100 °C and this shows that these glasses have good thermal stability of Tg such that they can be fabricated into optical fibers and as such can be considered candidates for high temperature infrared fiber optics. Initial fiber fabrication efforts showed that selected glasses could be drawn but larger samples would be needed for further development and optimization
Robotic Mars Sample Return and Earth entry vehicle concept development
NASA has studied potential Mars Sample Return over many decades, and the most recent Planetary Science Decadal Survey recommended making significant progress on this topic one of its highest priority goals. Recent inter-agency discussions and scientific support are lending credence to current Mars Sample Return planning activities, which notionally target launch of Sample Retrieval Lander and Earth Return Orbiter flight elements in 2026, and return of Martian samples to Earth in 2031. As part of the Mars Sample Return architecture under consideration, an Earth Entry Vehicle would perform the final phase by protecting the samples through severe entry environments using a 60-deg. sphere-cone flying on a passive/ballistic trajectory. The Earth Entry Vehicle design activities in particular are considering a variety of potential challenges, including: minimizing vehicle mass due to the need to travel to Mars and back to Earth, vehicle robustness to Micrometeroid and Orbital Debris impacts, capability to withstand severe entry environments while minimizing landing ellipse size, and providing impact load attenuation during a high-speed landing to meet Martian sample tube load limits and ensure sample containment in off-nominal scenarios. The present work provides a snapshot of current study work in progress, and highlights paths being taken to address these various design challenges for the conceptual Earth Entry Vehicle.
Design of a Compact Fatigue Tester for Testing Irradiated Materials
A compact fatigue testing machine that can be easily inserted into a hot cell for characterization of irradiated materials is beneficial to help determine relative fatigue performance differences between new and irradiated material. Hot cell use has been carefully considered by limiting the size and weight of the machine, simplifying sample loading and test setup for operation via master-slave manipulator, and utilizing an efficient design to minimize maintenance. Funded from a US-Japan collaborative effort, the machine has been specifically designed to help characterize titanium material specimens. These specimens are flat cantilevered beams for initial studies, possibly utilizing samples irradiated at other sources of beam. The option to test spherically shaped samples cut from the T2K vacuum window is also available. The machine is able to test a sample to $10^7$ cycles in under a week, with options to count cycles and sense material failure. The design of this machine will be presented along with current status.
Physical Properties of the Stone Meteorites: Implications for the Properties of Their Parent Bodies
The physical properties of the stone meteorites provide important clues to understanding the formation and physical evolution of material in the Solar protoplanetary disk as well providing indications of the properties of their asteroidal parent bodies. Knowledge of these properties is essential for modeling a number of Solar System processes, such as bolides in planetary atmospheres, the thermal inertia of atmosphereless solid body surfaces, and the internal physical and thermal evolution of asteroids and rock-rich icy bodies. In addition, insight into the physical properties of the asteroids is important for the design of robotic and crewed reconnaissance, lander, and sample return spacecraft missions to the asteroids. One key property is meteorite porosity, which ranges from 0% to more than 40%, similar to the range of porosities seen in asteroids. Porosity affects many of the other physical properties including thermal conductivity, speed of sound, deformation under stress, strength, and response to impact. As a result of the porosity, the properties of most stone meteorites differ significantly from those of compact terrestrial rocks, whose physical properties have been used in many models of asteroid behavior. A few physical properties, such as grain density, magnetic susceptibility, and heat capacity are not functions of porosity. Taken together, the grain density and the magnetic susceptibility can be used to classify unweathered or minimally weathered ordinary chondrites. This provides a rapid screening technique to identify heterogeneous samples, classify new samples, and identify misclassified meteorites or interlopers in strewn fields.
Improvement in the Characterization of MODIS Subframe Difference
MODIS is a key instrument of NASA's Earth Observing System. It has successfully operated for 16+ years on the Terra satellite and 14+ years on the Aqua satellite, respectively. MODIS has 36 spectral bands at three different nadir spatial resolutions, 250m (bands 1-2), 500m (bands 3-7), and 1km (bands 8-36). MODIS subframe measurement is designed for bands 1-7 to match their spatial resolution in the scan direction to that of the track direction. Within each 1 km frame, the MODIS 250 m resolution bands sample four subframes and the 500 m resolution bands sample two subframes. The detector gains are calibrated at a subframe level. Due to calibration differences between subframes, noticeable subframe striping is observed in the Level 1B (L1B) products, which exhibit a predominant radiance-level dependence. This paper presents results of subframe differences from various onboard and earth-view data sources (e.g. solar diffuser, electronic calibration, spectro-radiometric calibration assembly, Earth view, etc.). A subframe bias correction algorithm is proposed to minimize the subframe striping in MODIS L1B image. The algorithm has been tested using sample L1B images and the vertical striping at lower radiance value is mitigated after applying the corrections. The subframe bias correction approach will be considered for implementation in future versions of the calibration algorithm.
Comet nucleus sample return
A comet nucleus sample return mission has been proposed for implementation near the end of this century. The objective of the mission is to collect a sample of undisturbed material from beneath the surface of an active comet and return it to earth in a minimally altered state. Potential targets include the short-period comets Encke, Tempel 2 and Wild 2. This article defines such a mission and describes its requirements with regard to science, sampling, thermal protection and performance. It has been determined that, with present launch capabilities, Solar Electric Propulsion (SEP) is an enabling technology for this mission.
A comet nucleus sample return mission
A comet nucleus sample return mission has been proposed for implementation near the end of this century. The objective of the mission is to collect a sample of undisturbed material from beneath the surface of an active comet and return it to earth in a minimally altered state. Potential targets include the short-period comets Encke, Tempel 2 and Wild 2. This paper defines such a mission and describes its requirements with regard to science, sampling, thermal protection and performance. It has been determined that with present launch capabilities, Solar Electric Propulsion (SEP) is an enabling technology for this mission and total program costs would be in the 700 million to 1 billion (FY '84) dollar range.
Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity
Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.
Pharmacokinetic Modeling of Intranasal Scopolamine in Plasma Saliva and Urine
An intranasal gel formulation of scopolamine (INSCOP) was developed for the treatment of Space Motion Sickness. The bioavailability and pharmacokinetics (PK) were evaluated under the Food and Drug Administration guidelines for clinical trials for an Investigative New Drug (IND). The aim of this project was to develop a PK model that can predict the relationship between plasma, saliva and urinary scopolamine concentrations using data collected from the IND clinical trial with INSCOP. METHODS: Twelve healthy human subjects were administered three dose levels (0.1, 0.2 and 0.4 mg) of INSCOP. Serial blood, saliva and urine samples were collected between 5 min to 24 h after dosing and scopolamine concentrations measured by using a validated LC-MS-MS assay. Pharmacokinetic Compartmental models, using actual dosing and sampling times, were built using Phoenix (version 1.2). Model discrimination was performed, by minimizing the Akaike Information Criteria (AIC), maximizing the coefficient of determination (r²) and by comparison of the quality of fit plots. RESULTS: The best structural model to describe scopolamine disposition after INSCOP administration (minimal AIC =907.2) consisted of one compartment for plasma, saliva and urine respectively that were inter-connected with different rate constants. The estimated values of PK parameters were compiled in Table 1. The model fitting exercises revealed a nonlinear PK for scopolamine between plasma and saliva compartments for K21, Vmax and Km. CONCLUSION: PK model for INSCOP was developed and for the first time it satisfactorily predicted the PK of scopolamine in plasma, saliva and urine after INSCOP administration. Using non-linear PK yielded the best structural model to describe scopolamine disposition between plasma and saliva compartments, and inclusion of non-linear PK resulted in a significant improved model fitting. The model can be utilized to predict scopolamine plasma concentration using saliva and/or urine data that allows non-invasive assessment of pharmacotherapeutics of scopolamine in space and other remote environments without requiring blood sampling.
Search for minimal supersymmetric standard model Higgs Bosons H / A and for a $Z^{\prime}$ boson in the $\tau\tau $ final state produced in pp collisions at $\sqrt{s}$= 13 TeV with the ATLAS detector
A search for neutral Higgs bosons of the minimal supersymmetric standard model (MSSM) and for a heavneutral Z ' boson is performed using a data sample corresponding to an integrated luminosity of 3.2 fb - 1 from proton–proton collisions at √s=13 TeV recorded by the ATLAS detector at the LHC. The heavy resonance is assumed to decay to a τ + τ - pair with at least one τ lepton decaying to final states with hadrons and a neutrino. The search is performed in the mass range of 0.2–1.2 TeV for the MSSM neutral Higgs bosons and 0.5–2.5 TeV for the heavy neutral Z ' boson. The data are in good agreement with the background predicted by the Standard Model. The results are interpreted in MSSM and Z ' benchmark scenarios. The most stringent constraints on the MSSM m A –tan β space exclude at 95 % confidence level (CL) tan β > 7.6 for m A = 200 GeV in the m$mod+\atop{h}$ MSSM scenario. For the Sequential Standard Model, a Z$'\atop{SSM}$ mass up to 1.90 TeV is excluded at 95 % CL and masses up to 1.82–2.17 TeV are excluded for a Z'$\atop{SFM}$ of the strong flavour model.
First measurement of the muon antineutrino double-differential charged-current quasielastic cross section
The largest sample ever recorded of v ¯ μ charged-current quasielastic (CCQE, ν ¯<!-- ¯ --> μ + p → μ + + n ) candidate events is used to produce the minimally model-dependent, flux-integrated double-differential cross section d 2 σ d T μ d c o s θ μ ν ¯<!-- ¯ --> μ for v ¯ μ CCQE for a mineral oil target. This measurement exploits the large statistics of the MiniBooNE antineutrino mode sample and provides the most complete information of this process to date. In order to facilitate historical comparisons, the flux-unfolded total cross section $σ(E_ν)$ and single-differential cross section d dσ Q 2 on both mineral oil and on carbon are also reported. The observed cross section is somewhat higher than the predicted cross section from a model assuming independently acting nucleons in carbon with canonical form factor values. The shape of the data are also discrepant with this model. Finally, these results have implications for intranuclear processes and can help constrain signal and background processes for future neutrino oscillation measurements.
Analysis of Fe Nanoparticles Using XPS Measurements Under D.C. or Pulsed-Voltage Bias
The impact of solution exposure on the charging properties of oxide coatings on Fe metal-core oxide-shells has been examined by sample biasing during XPS measurements. The Fe nanoparticles were suspended in relatively unreactive acetone and were analyzed after particle containing solutions were deposited on SiO2/Si substrates, and/or Au substrates. The particle and substrate combinations were subjected to ± 10V d.c. biasing in the form of square waves (SQW) pulses with 5V amplitude. The samples experienced variable degrees of charging for which low energy electrons at ~1 eV, 20μA and low energy Ar+ ions were used to minimize. Application of d.c. bias and/or square wave pulses drastically influences the extent of charging, which is utilized to gather additional analytical information about the sample under investigation. This approach allows separation of otherwise overlapping peaks. Accordingly, the O1s peaks of the silicon oxide substrate, the iron oxide nanoparticles, and that of the casting solvent can be separated from each other. Similarly the C1s peak belonging to the solvent can be separated from that of the adventitious carbon. The charging shifts of the iron nanoparticles are strongly influenced by the surrounding solvent. Hence, acetone exhibits the largest shift, water the smallest, and methanol in between. Dynamical measurements performed by application of the voltage stress in the form of SQW pulses gives information about the time constants of the processes involved, which led us postulate that these charging properties we probe in these systems, stem mainly from ionic movement(s).
Robust and effective methodologies for cryopreservation and DNA extraction from anaerobic gut fungi
Cell storage and DNA isolation are essential to developing an expanded suite of microorganisms for biotechnology. However, many features of non-model microbes, such as an anaerobic lifestyle and rigid cell wall, present formidable challenges to creating strain repositories and extracting high quality genomic DNA. We establish accessible, high efficiency, and robust techniques to store lignocellulolytic anaerobic gut fungi long term without specialized equipment. Using glycerol as a cryoprotectant, gut fungal isolates were preserved for a minimum of 23 months at -80 °C. Unlike previously reported approaches, this improved protocol is non-toxic and rapid, with samples surviving twice as long with negligible growth impact. Genomic DNA extraction for these isolates was optimized to yield samples compatible with next generation sequencing platforms (e.g. Illumina, PacBio). Popular DNA isolation kits and precipitation protocols yielded preps that were unsuitable for sequencing due to carbohydrate contaminants from the chitin-rich cell wall and extensive energy reserves of gut fungi. To address this, we identified a proprietary method optimized for hardy plant samples that rapidly yielded DNA fragments in excess of 10 kb with minimal RNA, protein or carbohydrate contamination. Collectively, these techniques serve as fundamental tools to manipulate powerful biomass-degrading gut fungi and improve their accessibility among researchers.