Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Development of an automated high-temperature valveless injection system for online gas chromatography

A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

Kreisberg, N. M.↗

Selection of Sampling and Surrogate Modeling Methods for State-Point Evaluations of an AGN-201M Reactor

Nuclear reactor digital twins (DTs) have been proposed for use as a safeguards technology to efficiently monitor new and novel reactors as they come online. A safeguards DT needs to be capable of detecting misuse and diversion as they occur, requiring physics models to be accurate and efficient. Mathematical surrogate models are capable of achieving the necessary efficiency and can largely maintain the accuracy of higher-order models given a quality training sample. The Multiphysics Object-Oriented Simulation Environment (MOOSE) code framework is specifically equipped to generate training samples and create surrogate models using full-order reactor physics models. Utilizing an operational AGN-201M reactor’s specifications, two surrogate types were trained on samples of variable size, and using Cartesian products, Latin hypercube sampling, and quadrature sampling, each was compared and evaluated on accuracy when compared to a full-order Monte Carlo model. Both surrogate types were able to capture reactivity changes within 0.05 $ of the Monte Carlo model while reducing the computation costs by eight orders of magnitude.

MOOSE↗

A spectral method for determining the percentage of green herbage material in clipped samples

A laboratory radiometric method for the rapid determination of green and brown vegetation percentages in clipped grass samples has been developed and tested. The method uses red and photographic infrared radiance or reflectance differences between green and brown vegetation. Mixtures of green and brown material were found to have radiances or reflectances proportional to the percentage of green material present. This method may permit the use of rapid green/brown radiometric determinations to replace the tedious hand sorting now generally used. It may also have application in remote sensing of vegetation ground-truth work where the determination of dry green biomass in clipped samples is necessary.

Tucker, C. J.↗

Computational methods for efficient structural reliability and reliability sensitivity analysis

This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.

Wu, Y.-T.↗

A spectral method for determining the percentage of live herbage material in clipped samples

A laboratory spectroradiometric method for the rapid determination of live/dead vegetation percentages from clipped grass samples has been developed and preliminarily tested. The method utilizes the red and photographic infrared reflectance or radiance differences between green vegetation and that of dead vegetation. Mixtures of green and dead material were found to have reflectances or radiances proportional to the percentage of green material present. This method offers the possibility that rapid live/dead spectroradiometric determinations may replace the tedious hand-sorting now generally in use for many situations.

Tucker, C. J.↗

Mars Sample Return orbital rendezvous detection methods

Navigation trades while in pursuit of a rendezvous with a sample capsule in orbit around Mars are described. The rendezvous operation is described in terms of far-field and near-field detection. Passive optical detection is compared with active capsule detection using a radio beacon. Passive methods are, to first order, unconstrained by time while a radio beacon link is time-limited. A possible activity to make use of orbiter plume interactions is explored.

Gustafson, Eric D.↗

Rapid determination of 226 Ra in emergency urine samples

A new method has been developed at the Savannah River National Laboratory (SRNL) that can be used for the rapid determination of 226 Ra in emergency urine samples following a radiological incident. If a radiological dispersive device event or a nuclear accident occurs, there will be an urgent need for rapid analyses of radionuclides in urine samples to ensure the safety of the public. Large numbers of urine samples will have to be analyzed very quickly. This new SRNL method was applied to 100 mL urine aliquots, however this method can be applied to smaller or larger sample aliquots as needed. The method was optimized for rapid turnaround times; urine samples may be prepared for counting in <3 h. A rapid calcium phosphate precipitation method was used to pre-concentrate 226 Ra from the urine sample matrix, followed by removal of calcium by cation exchange separation. A stacked elution method using DGA Resin was used to purify the 226 Ra during the cation exchange elution step. This approach combines the cation resin elution step with the simultaneous purification of 226 Ra with DGA Resin, saving time. 133 Ba was used instead of 225 Ra as tracer to allow immediate counting; however, 225 Ra can still be used as an option. The rapid purification of 226 Ra to remove interferences using DGA Resin was compared with a slightly longer Ln Resin approach. A final barium sulfate micro-precipitation step was used with isopropanol present to reduce solubility; producing alpha spectrometry sources with peaks typically <40 keV FWHM (full width half max). This new rapid method is fast, has very high tracer yield (>90 %), and removes interferences effectively. The sample preparation method can also be adapted to ICP-MS measurement of 226 Ra, with rapid removal of isobaric interferences.

61 RADIATION PROTECTION AND DOSIMETRY↗

Silicone wristbands compared with traditional polycyclic aromatic hydrocarbon exposure assessment methods

Currently there is a lack of inexpensive, easy-to-use technology to evaluate human exposure to environmental chemicals, including polycyclic aromatic hydrocarbons (PAHs). This is the first study in which silicone wristbands were deployed alongside other PAH exposure assessment methodologies. Wristbands were used within an established Columbia Center for Children’s Environmental Health birth cohort and compared to two traditional personal PAH exposure assessment methods: biological sampling with urine and active air monitoring with samplers (i.e. polyurethane foam (PUF) and filter) housed in backpacks. All samplers were deployed simultaneously on 22 pregnant women for 48-hours. Each woman provided one spot urine sample at the end of the 48-hour period. Sixty-two and 20 PAHs were quantified in the wristbands and PUF/filter, respectively; and eight hydroxy-PAH (OH-PAH) metabolites were quantified in the urine. PAHs in the PUF/filter and OH-PAHs correlate significantly for two of the eight comparisons (rs=0.53 and p=0.01; rs=0.44 and p=0.04). PAHs in the wristband and OH-PAHs correlate significantly for four of the eight comparisons; 1-OH-phenanthrene and 1-OH-pyrene strongly correlate with the parent PAHs in the wristband (rs=0.76 and p=<0.0001; rs=0.66 and p=0.0009). These results suggest wristbands are more closely associated with OH-PAHs in urine than active personal air monitoring methods.

Dixon, Holly M.↗

Methods for purifying carbon materials

Methods of purifying samples are provided that are capable of removing carbonaceous and noncarbonaceous impurities from a sample containing a carbon material having a selected structure. Purification methods are provided for removing residual metal catalyst particles enclosed in multilayer carbonaceous impurities in samples generate by catalytic synthesis methods. Purification methods are provided wherein carbonaceous impurities in a sample are at least partially exfoliated, thereby facilitating subsequent removal of carbonaceous and noncarbonaceous impurities from the sample. Methods of purifying carbon nanotube-containing samples are provided wherein an intercalant is added to the sample and subsequently reacted with an exfoliation initiator to achieve exfoliation of carbonaceous impurities.

36 MATERIALS SCIENCE↗

On-the-Fly Treatment of Temperature Dependent Cross Sections in the Unresolved Resonance Regions in RMC Code

Monte Carlo method can provide high fidelity neutronics analysis of different nuclear reactors, owing to its advantages of the flexible geometry modeling and the use of continuous-energy nuclear cross sections. It can also be coupled with thermal-hydraulics codes to consider the feedback. For thermal reactors such as PWR and HTGR, two main temperature effects should be considered. The first is the effect of thermal motion of target nuclei in resolved resonance energy regions, which is known as Doppler effect. The second is the thermal scattering and bound effect in thermal energy regions. The traditional approach of pre-generated cross sections has difficulty in memory footprint for detailed temperature modelling in multi-physics calculations. Recently, on-the-fly (OTF) technique has been proposed in order to reduce the memory consumption for both resolved resonance energy and thermal energy. For fast reactors calculations, the temperature dependence of cross sections in the unresolved resonance energy regions is also important. However, less attention was paid to the unresolved resonance regions compared with resolved resonance energy and thermal energy. In this paper, the on-the-fly temperature treatment of cross sections in unresolved resonance regions was proposed and developed in RMC codes. The results show that the on-the-fly treatment has high efficiency and satisfactory fidelity. The on-the-fly treatment of unresolved resonance region was also combined with the target motion sampling (TMS) method for resolved resonance energy. The formats of libraries were changed, in which the probability tables were separated from the cross sections. Then the interpolation of probability table was performed on-the-fly during the transport routine. The results show that the on-the-fly treatment has high efficiency and satisfactory fidelity. The on-the-fly treatment of unresolved resonance region was also combined with the target motion sampling (TMS) method for resolved resonance energy, showing that TMS method is effective and accurate for cross sections treatment in resolved resonance energy regions. The memory saving of the on-the-fly treatment is also considerable. For the high-fidelity 'transport-burnup-thermal-hydraulics' coupling calculation, the memory requirement is 60 Mb. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A simple and practical wax-encapsulation method for air-sensitive XAS samples

To facilitate X-ray absorption spectroscopy (XAS) measurements of air-sensitive samples, we present a simple method in which materials are encased in common paraffin wax to protect them from air and moisture. We demonstrate the efficacy of this approach using a highly reducing, air- and moisture-sensitive uranium(III) complex, the tris(amide) U[N(SiMe 3 ) 2 ] 3 (1). When finely dispersed in a boron nitride matrix and subsequently encased in inert paraffin wax, samples of 1 remain stable with no visible or spectroscopic degradation after several days under ambient conditions. The viability of this method for XAS measurements was further evaluated across a series of uranium compounds, ranging from uranyl species to highly air- and moisture-sensitive molecular complexes, at the uranium L 3 -edge. Edge energy determinations were highly reproducible (±0.1 eV between replicates) and, where available, showed excellent agreement with literature values. In conclusion, this low-cost, effective, and versatile method offers a viable solution for XAS studies of air-sensitive compounds and materials.

36 MATERIALS SCIENCE↗

A comparison of methods for representing sparsely sampled random quantities.

This report discusses the treatment of uncertainties stemming from relatively few samples of random quantities. The importance of this topic extends beyond experimental data uncertainty to situations involving uncertainty in model calibration, validation, and prediction. With very sparse data samples it is not practical to have a goal of accurately estimating the underlying probability density function (PDF). Rather, a pragmatic goal is that the uncertainty representation should be conservative so as to bound a specified percentile range of the actual PDF, say the range between 0.025 and .975 percentiles, with reasonable reliability. A second, opposing objective is that the representation not be overly conservative; that it minimally over-estimate the desired percentile range of the actual PDF. The presence of the two opposing objectives makes the sparse-data uncertainty representation problem interesting and difficult. In this report, five uncertainty representation techniques are characterized for their performance on twenty-one test problems (over thousands of trials for each problem) according to these two opposing objectives and other performance measures. Two of the methods, statistical Tolerance Intervals and a kernel density approach specifically developed for handling sparse data, exhibit significantly better overall performance than the others.

Romero, Vicente Jose↗

Characterization of CoMCM-41 mesoporous molecular sieves obtained by the microwave irradiation method

CoMCM-41 mesoporous molecular sieves with different amounts of cobalt were synthesized via the microwave irradiation method. The samples were characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), temperature programmed reduction (TPR), transmission electron microscopy (TEM) and N{sub 2} adsorption-desorption technique, and thermal and hydrothermal stabilities of synthesized CoMCM-41 samples were also investigated. Results show that these synthesized materials have typical mesoporous structure of MCM-41. Also, specific surface area and pore volume of synthesized CoMCM-41 decrease with increasing amount of cobalt added, and mesoporous ordering also decreases. When the molar ratio of SiO{sub 2}:CoO in the starting material is 1.0:0.05, mesoporous ordering of synthesized CoMCM-41 is the best among the four doping contents. On the other hand, results of thermal and hydrothermal tests show that CoMCM-41 after calcination at 750 deg. C for 3 h or hydrothermal treatment at 100 deg. C for 5 days still retains mesostructure. However, mesoporous framework is entirely damaged after calcination at 850 deg. C for 3 h. - Graphical abstract: CoMCM-41 mesoporous molecular sieves with different amounts of cobalt were synthesized via the microwave irradiation method. The samples were characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR), temperature programmed reduction (TPR), transmission electron microscopy (TEM) and N{sub 2} adsorption-desorption technique, and thermal and hydrothermal stabilities of synthesized CoMCM-41 samples were also investigated. The results show that these synthesized materials have typical MCM-41 structure and highly thermal and hydrothermal stabilities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Determination Of Radiostrontium In Large Soil Samples

A new method for the determination of radiostrontium in large soil samples has been developed at the Savannah River Environmental Laboratory (Aiken, SC, USA) that allows rapid preconcentration and separation of strontium in large soil samples for the measurement of strontium isotopes by gas flow proportional counting. The need for rapid analyses in the event of a Radiological Dispersive Device (RDD) or Improvised Nuclear Device (IND) event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. The method employs a novel pre-concentration step that utilizes an iron hydroxide precipitation (enhanced with calcium phosphate) followed by a final calcium fluoride precipitation to remove silicates and other matrix components. The pre-concentration steps, in combination with a rapid Sr Resin separation using vacuum box technology, allow very large soil samples to be analyzed for {sup 89,90}Sr using gas flow proportional counting with a lower method detection limit. The calcium fluoride precipitation eliminates column flow problems typically associated with large amounts of silicates in large soil samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Quantitative Tracking of Isotope Flows in Proteomes of Microbial Communities

Stable isotope probing (SIP) has been used to track nutrient flows in microbial communities, but existing protein-based SIP methods capable of quantifying the degree of label incorporation into peptides and proteins have been demonstrated only by targeting usually less than 100 proteins per sample. Our method automatically (i) identifies the sequence of and (ii) quantifies the degree of heavy atom enrichment for thousands of proteins from microbial community proteome samples. These features make our method suitable for comparing isotopic differences between closely related protein sequences, and for detecting labeling patterns in low-abundance proteins or proteins derived from rare community members. The proteomic SIP method was validated using proteome samples of known stable isotope incorporation levels at 0.4%, 50%, and 98%. The method was then used to monitor incorporation of 15N into established and regrowing microbial biofilms. The results indicate organism-specific migration patterns from established communities into regrowing communities and provide insights into metabolism during biofilm formation. The proteomic SIP method can be extended to many systems to track fluxes of 13C or 15N in microbial communities. Molecular & Cellular Proteomics 10: 10.1074/mcp.M110.006049, 1–11, 2011.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional nanoscale characterisation of materials by atom probe tomography

The development of three-dimensional (3D), characterization techniques with high spatial and mass resolution is crucial for understanding and developing advanced materials for many engineering applications as well as for understanding natural materials. In recent decades, atom probe tomography (APT) which combines a point projection microscope and time-of-flight mass spectrometer has evolved to be an excellent characterization technique capable of providing 3D nanoscale characterization of materials with sub-nanometer scale spatial resolution, with equal sensitivity for all elements. This review discusses the current state as of beginning of the year 2016 of APT instrumentation, new developments in sample preparation methods, experimental procedures for different material classes, reconstruction of APT results, the current status of correlative microscopy, and application of APT for microstructural characterization in established scientific areas like structural materials as well as new applications in semiconducting nanowires, semiconductor devices, battery materials, catalyst materials, geological materials and biological materials. Finally, a brief perspective is given regarding the future of APT.

Atom Probe Tomography, characterization, microstru↗

Three-Phase 3D Reconstruction of a LiCoO2 Cathode via FIB-SEM Tomography

Abstract Three-phase three-dimensional (3D) microstructural reconstructions of lithium-ion battery electrodes are critical input for 3D simulations of electrode lithiation/delithiation, which provide a detailed understanding of battery operation. In this report, 3D images of a LiCoO 2 electrode are achieved using focused ion beam-scanning electron microscopy (FIB-SEM), with clear contrast among the three phases: LiCoO 2 particles, carbonaceous phases (carbon and binder) and the electrolyte space. The good contrast was achieved by utilizing an improved FIB-SEM sample preparation method that combined infiltration of the electrolyte space with a low-viscosity silicone resin and triple ion-beam polishing. Morphological parameters quantified include phase volume fraction, surface area, feature size distribution, connectivity, and tortuosity. Electrolyte tortuosity was determined using two different geometric calculations that were in good agreement. The electrolyte tortuosity distribution versus position within the electrode was found to be highly inhomogeneous; this will lead to inhomogeneous electrode lithiation/delithiation at high C-rates that could potentially cause battery degradation.

Liu, Zhao (ORCID:0000000303702406)↗

Quantitative tracking of isotope flows in proteomes of microbial communities

Stable isotope probing (SIP) has been used to track nutrient flows in microbial communities, but existing protein-based SIP methods capable of quantifying the degree of label incorporation into peptides and proteins have been demonstrated only by targeting usually less than 100 proteins per sample. Our method automatically (i) identifies the sequence of and (ii) quantifies the degree of heavy atom enrichment for thousands of proteins from microbial community proteome samples. These features make our method suitable for comparing isotopic differences between closely related protein sequences, and for detecting labeling patterns in low-abundance proteins or proteins derived from rare community members. The proteomic stable isotope probing (SIP) method was validated using proteome samples of known stable isotope incorporation levels at 0.4%, {approx}50%, and {approx}98%. The method was then used to monitor incorporation of 15N into established and regrowing microbial biofilms. The results indicate organism-specific migration patterns from established into regrowing communities and provides insight into metabolism during biofilm formation. The SIP-proteomics method can be extended to many systems to track fluxes of 13C or 15N in microbial communities.

59 BASIC BIOLOGICAL SCIENCES↗