Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Method for phase retrieval to reduce a sampling requirement when imaging a dynamic process

A method for retrieving phase information in a coherent diffraction imaging process includes acquiring a plurality of 3D data sets, each 3D data set corresponding to one of a plurality of time states, and reconstructing a 3D image of the object at a given time state using the 3D data set from all of the time states. Each 3D data set is acquired by: illuminating an object positioned in a first position with a coherent beam; measuring a first 2D diffraction pattern using an area detector; rotating the object around a tilt axis thereof to a second position that is different from the first position; re-illuminating the object positioned in the second position with the coherent beam; re-measuring a second 2D diffraction pattern using the area detector; and repeating the rotating, re-illuminating and re-measuring steps such that each 3D data set includes a predetermined number of diffraction patterns.

36 MATERIALS SCIENCE↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused on their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.

Valdez, Carlos A.↗

Optical Methods for Identifying Hard Clay Core Samples During Petrophysical Studies

X-ray phase analysis of the general mineralogical composition of core samples from one of the West Siberian fields was performed. Electronic absorption spectra of the clay core samples with an added indicator were studied. The speed and availability of applying the two methods in petrophysical laboratories during sample preparation for standard and special studies were estimated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: A pure-sampling quantum Monte Carlo algorithm with independent Metropolis

Recently, Ospadov and Rothstein published a pure-sampling quantum Monte Carlo algorithm (PSQMC) that features an auxiliary Path Z that connects the midpoints of the current and proposed Paths X and Y, respectively. When sufficiently long, Path Z provides statistical independence of Paths X and Y. Under those conditions, the Metropolis decision used in PSQMC is done without any approximation, i.e., not requiring microscopic reversibility and without having to introduce any G(x → x′; τ) factors into its decision function. This is a unique feature that contrasts with all competing reptation algorithms in the literature. An example illustrates that dependence of Paths X and Y has adverse consequences for pure sampling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Component separation of a isotropic Gravitational Wave Background

A Gravitational Wave Background (GWB) is expected in the universe from the superposition of a large number of unresolved astrophysical sources and phenomena in the early universe. Each component of the background (e.g., from primordial metric perturbations, binary neutron stars, milli-second pulsars etc.) has its own spectral shape. Many ongoing experiments aim to probe GWB at a variety of frequency bands. In the last two decades, using data from ground-based laser interferometric gravitational wave (GW) observatories, upper limits on GWB were placed in the frequency range of 0∼ 50−100 Hz, considering one spectral shape at a time. However, one strong component can significantly enhance the estimated strength of another component. Hence, estimation of the amplitudes of the components with different spectral shapes should be done jointly. Here we propose a method for 'component separation' of a statistically isotropic background, that can, for the first time, jointly estimate the amplitudes of many components and place upper limits. The method is rather straightforward and needs negligible amount of computation. It utilises the linear relationship between the measurements and the amplitudes of the actual components, alleviating the need for a sampling based method, e.g., Markov Chain Monte Carlo (MCMC) or matched filtering, which are computationally intensive and cumbersome in a multi-dimensional parameter space. Using this formalism we could also study how many independent components can be separated using a given dataset from a network of current and upcoming ground based interferometric detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Reducing statistical uncertainties in simulated organ doses of phantoms immersed in water

In this study, methods are addressed to reduce the computational time to compute organ-dose rate coefficients using Monte Carlo techniques. Several variance reduction techniques are compared including the reciprocity method, importance sampling, weight windows and the use of the ADVANTG software package. For low-energy photons, the runtime was reduced by a factor of 10 5 when using the reciprocity method for kerma computation for immersion of a phantom in contaminated water. This is particularly significant since impractically long simulation times are required to achieve reasonable statistical uncertainties in organ dose for low-energy photons in this source medium and geometry. Although the MCNP Monte Carlo code is used in this paper, the reciprocity technique can be used equally well with other Monte Carlo codes.

61 RADIATION PROTECTION AND DOSIMETRY↗

WHONDRS Surface Water Dissolved Organic Carbon and FTICR-MS across Stream Orders in Four United States Watersheds in 2019 and 2020 (v3)

This dataset supports the broader Watershed Rules of Life (WROL) study examining spatial and temporal biogeochemical and microbial relationships across the Connecticut River, Deschutes River, Gunnison River, and Willamette River watersheds. The dataset provides geochemistry and organic matter characterization data generated from surface water collected from August 2019 to September 2020 in Colorado, Connecticut, Oregon, and Vermont. Related data were collected and will be published separately in collaboration with P. A. Raymond and B. C. Crump as part of WROL. This dataset is comprised of one folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) dissolved organic carbon (DOC, measured as non-purgeable organic carbon, NPOC) data and averages; (6) surface water sampling protocol; (7) methods codes; (8) international generic sample number (IGSN) mapping file; and (9) a folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) generated through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). The FTICR folder contains two subfolders, one containing the .xml data files and the other containing instructions for using Formularity (https://omics.pnl.gov/software/formularity) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .R, .ref, or .xml. This data package was originally published in October 2022. It was updated in July 2023 (v2) and again in November 2023 (v3). See the change history section in the readme for more details.

54 ENVIRONMENTAL SCIENCES↗

PenDoc Assistant v2.00

The purpose of this software is: - control and acquire data files from an Advion CMS single-quad mass spectrometer - targeted compound analysis - sample classification List of features: - use of experimental profiles for easy data acquisition - external touchscreen for easy experiment control - simple Yes/No answer if the signal of a targeted analyte is above a predefined limit - build database and classify sample using multiple spectral comparison/similarity methods Specific application: sample classification using an Advion CMS single quadrupole mass spectrometer connected to an Open Port Sampling Interface (OPSI).

Kertesz, Vilmos↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Reexamination of Basal Plane Thermal Conductivity of Suspended Graphene Samples Measured by Electro-Thermal Micro-Bridge Methods

Thermal transport in suspended graphene samples has been measured in prior works and this work with the use of a suspended electro-thermal micro-bridge method. These measurement results are analyzed here to evaluate and eliminate the errors caused by the extrinsic thermal contact resistance. It is noted that the thermal resistance measured in a recent work increases linearly with the suspended length of the single-layer graphene samples synthesized by chemical vapor deposition (CVD), and that such a feature does not reveal the failure of Fourier s law despite the increase in the apparent thermal conductivity with length. The re-analyzed thermal conductivity of a single-layer CVD graphene sample reaches about ( 1680 180 )Wm-1K-1 at room temperature, which is close to the highest value reported for highly oriented pyrolytic graphite. In comparison, the thermal conductivity values measured for two suspended exfoliated bi-layer graphene samples are about ( 880 60 ) and ( 730 60 ) Wm-1K-1 at room temperature, and approach that of the natural graphite source above room temperature. However, the low-temperature thermal conductivities of these suspended graphene samples are still considerably lower than the graphite values, with the peak thermal conductivities shifted to much higher temperatures. Analysis of the thermal conductivity data reveals that the low temperature behavior is dominated by phonon scattering by polymer residue instead of by the lateral boundary.

36 MATERIALS SCIENCE↗

Measurements of Neutron Scattering from a Copper Sample Using a Quasi-Differential Method in the Region from 2 keV to 20 MeV

Neutron scattering from a copper sample was measured at Rensselaer Polytechnic Institute utilizing the quasi-differential method. The measurement spanned the energy range from 0.5 to 20 MeV using the high-energy scattering system and from 2 keV to 0.5 MeV using the new mid-energy scattering system. Copper was selected as a material of interest to measure due to large discrepancies between experiments and simulations of the Zeus benchmark. The Zeus benchmark consists of a copper reflected highly enriched uranium system, and the angular distribution of copper scattering was thought to potentially be the cause of the discrepancy. The copper measurements found differences in the scattering response particularly in the incident energy region from 1 to 2 MeV for the high-energy measurement and from 2 to 4 keV in the mid-energy system. These differences are particularly noticeable at angles near 90 deg in the high-energy system and back angles in the mid-energy system. Additionally, for ENDF/B-VIII.0 there is a large discrepancy at the forward angle in the energy range around 0.5 MeV. For these reasons, a new evaluation of copper scattering utilizing these results is recommended and perhaps could help to improve the agreement with the Zeus benchmarks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Less magnetic and larger Zr{sup 4+}–Zn{sup 2+} ions co-substituted structural and magnetic properties of ordered Li{sub 0.5}Fe{sub 2.5}O{sub 4} nanoparticles

Graphical abstract: - Highlights: • Zr{sup 4+} and Zn{sup 2+} co-substituted Li{sub 0.5}Fe{sub 2.5}O{sub 4}. • Crystallite size decreased with Zr{sup 4+} and Zn{sup 2+} co-substitution. • Magnetization results exhibit collinear ferrimagnetic structure for x = 0.2. • Yafet–Kittle angle exists between the observed and calculated magneton number. - Abstract: Samples of Zr{sup 4+} and Zn{sup 2+} co-substituted Li{sub 0.5}Fe{sub 2.5}O{sub 4} nanoparticles were prepared by the sol–gel auto-combustion method. The samples were obtained by annealing at relatively low temperature at 600 °C and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), vibrating sample magnetometry (VSM) and Fourier transform infrared (FT-IR) spectroscopy. Lattice parameter, X-ray density, specific surface area and porosity were found to increase, whereas bulk density and crystallite size showed the decreasing trend with the Zr{sup 4+} and Zn{sup 2+} substitution. Cation distribution estimated from XRD results suggests that Zn{sup 2+} and Li{sup +} occupy tetrahedral A- and octahedral B-site respectively, whereas Zr{sup 4+} and Fe{sup 3+} occupy both the available sites. The FT-IR spectra show two major absorption bands at 715–749 cm{sup −1} (ν{sub 1}) and 484–507 cm{sup −1} (ν{sub 2}) related to spinel structure of ferrite. Magnetization results exhibit collinear ferrimagnetic structure for x ≤ 0.2, and changed to the non-collinear for x > 0.2. Observed and calculated magneton number shows discrepancy in their values that gives rise to Yafet–Kittle angle for x > 0.2.

36 MATERIALS SCIENCE↗

Numerical Continuation Methods for Intrusive Uncertainty Quantification Studies

Rigorous modeling of engineering systems relies on efficient propagation of uncertainty from input parameters to model outputs. In recent years, there has been substantial development of probabilistic polynomial chaos (PC) Uncertainty Quantification (UQ) methods, enabling studies in expensive computational models. One approach, termed ”intrusive”, involving reformulation of the governing equations, has been found to have superior computational performance compared to non-intrusive sampling-based methods in relevant large-scale problems, particularly in the context of emerging architectures. However, the utility of intrusive methods has been severely limited due to detrimental numerical instabilities associated with strong nonlinear physics. Previous methods for stabilizing these constructions tend to add unacceptably high computational costs, particularly in problems with many uncertain parameters. In order to address these challenges, we propose to adapt and improve numerical continuation methods for the robust time integration of intrusive PC system dynamics. We propose adaptive methods, starting with a small uncertainty for which the model has stable behavior and gradually moving to larger uncertainty where the instabilities are rampant, in a manner that provides a suitable solution.

97 MATHEMATICS AND COMPUTING↗

Apparatus for point-of-care detection of nucleic acid in a sample

Provided herein are methods and apparatus for detecting a target nucleic acid in a sample and related methods and apparatus for diagnosing a condition in an individual. The condition is associated with presence of nucleic acid produced by certain pathogens in the individual.

59 BASIC BIOLOGICAL SCIENCES↗

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Harmonic analysis of discrete tracers of large-scale structure

It is commonplace in cosmology to analyze fields projected onto the celestial sphere, and in particular density fields that are defined by a set of points e.g. galaxies. When performing an harmonic-space analysis of such data (e.g. an angular power spectrum) using a pixelized map one has to deal with aliasing of small-scale power and pixel window functions. We compare and contrast the approaches to this problem taken in the cosmic microwave background and large-scale structure communities, and advocate for a direct approach that avoids pixelization. We describe a method for performing a pseudo-spectrum analysis of a galaxy data set and show that it can be implemented efficiently using well-known algorithms for special functions that are suited to acceleration by graphics processing units (GPUs). The method returns the same spectra as the more traditional map-based approach if in the latter the number of pixels is taken to be sufficiently large and the mask is well sampled. The method is readily generalizable to cross-spectra and higher-order functions. It also provides a convenient route for distributing the information in a galaxy catalog directly in harmonic space, as a complement to releasing the configuration-space positions and weights, and a route to spectral apodization. Finally, we make public a code enabling the application of our method to existing and upcoming datasets.

79 ASTRONOMY AND ASTROPHYSICS↗

Redshift inference from the combination of galaxy colours and clustering in a hierarchical Bayesian model – Application to realistic N -body simulations

ABSTRACT Photometric galaxy surveys constitute a powerful cosmological probe but rely on the accurate characterization of their redshift distributions using only broad-band imaging, and can be very sensitive to incomplete or biased priors used for redshift calibration. A hierarchical Bayesian model has recently been developed to estimate those from the robust combination of prior information, photometry of single galaxies, and the information contained in the galaxy clustering against a well-characterized tracer population. In this work, we extend the method so that it can be applied to real data, developing some necessary new extensions to it, especially in the treatment of galaxy clustering information, and we test it on realistic simulations. After marginalizing over the mapping between the clustering estimator and the actual density distribution of the sample galaxies, and using prior information from a small patch of the survey, we find the incorporation of clustering information with photo-z’s tightens the redshift posteriors and overcomes biases in the prior that mimic those happening in spectroscopic samples. The method presented here uses all the information at hand to reduce prior biases and incompleteness. Even in cases where we artificially bias the spectroscopic sample to induce a shift in mean redshift of $\Delta \bar{z} \approx 0.05,$ the final biases in the posterior are $\Delta \bar{z} \lesssim 0.003.$ This robustness to flaws in the redshift prior or training samples would constitute a milestone for the control of redshift systematic uncertainties in future weak lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗