Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Equilibrium Climate Sensitivity Estimated by Equilibrating Climate Models

The methods to quantify equilibrium climate sensitivity are still debated. We collect millennial length simulations of coupled climate models and show that the global mean equilibrium warming is higher than those obtained using extrapolation methods from shorter simulations. Specifically, 27 simulations with 15 climate models forced with a range of CO2 concentrations show a median 17% larger equilibrium warming than estimated from the first 150 years of the simulations. The spatial patterns of radiative feedbacks change continuously, in most regions reducing their tendency to stabilizing the climate. In the equatorial Pacific, however, feedbacks become more stabilizing with time. The global feedback evolution is initially dominated by the tropics, with eventual substantial contributions from the midlatitudes. Time dependent feedbacks underscore the need of a measure of climate sensitivity that accounts for the degree of equilibration, so that models, observations, and paleo proxies can be adequately compared and aggregated to estimate future warming.

Maria Rugenstein↗

Investigation of interfacial rheology & foam stability.

The rheology at gas-liquid interfaces strongly influences the stability and dynamics of foams and emulsions. Several experimental techniques are employed to characterize the rheology at liquid-gas interfaces with an emphasis on the non-Newtonian behavior of surfactant-laden interfaces. The focus is to relate the interfacial rheology to the foamability and foam stability of various aqueous systems. An interfacial stress rheometer (ISR) is used to measure the steady and dynamic rheology by applying an external magnetic field to actuate a magnetic needle suspended at the interface. Results are compared with those from a double wall ring attachment to a rotational rheometer (TA Instruments AR-G2). Micro-interfacial rheology (MIR) is also performed using optical tweezers to manipulate suspended microparticle probes at the interface to investigate the steady and dynamic rheology. Additionally, a surface dilatational rheometer (SDR) is used to periodically oscillate the volume of a pendant drop or buoyant bubble. Applying the Young-Laplace equation to the drop shape, a time-dependent surface tension can be calculated and used to determine the effective dilatational viscosity of an interface. Using the ISR, double wall ring, SDR, and MIR, a wide range of sensitivity in surface forces (fN to nN) can be explored as each experimental method has different sensitivities. Measurements will be compared to foam stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Method Development and Validation of Naloxone and 6α‐naloxol from Male African Green Monkey Plasma.

Theopioid epidemic is a rapidly growing crisis around the world. Current models forpharmacokinetic assessment of countermeasures use African green monkeys (AGM). Arapid, sensitive and selective method was developed and validated usingLC‐MS/MS for the determination of naloxone and 6α‐naloxol in AGM plasma. Samplepreparation involved a simple solid phase extraction (SPE) using ahydrophilic‐lipophilic‐balanced reversed‐phase cartridge. Separation of naloxoneand 6α‐naloxol was achieved on a Halo C18, 2.1 × 50 mm, 2.7μ analytical columnusing an Agilent 1290 Infinity HPLC. A solvent system of methanol‐water‐formicacid was used for the elution of analytes. The analytes were detected and monitoredby a SCIEX QTRAP 6500 + triple quadrupole tandem mass spectrometer operatedin electrospray ionization (ESI) positive mode and multiple reaction monitoring(MRM). Molecular ion transitions for naloxone, 6α‐naloxol and naloxone‐D5 were 328.0/212.0,330.0/185.0, and 333.1/212.0 m/z, respectively. The method was validated usingcalibration and recovery assays with spiked samples. Linear calibration curveswere generated over the range of 1.5–100 ng/ml with values for the coefficientof determination (R 2 ) of >0.9950. The values for both inter‐dayand intra‐day precision and accuracy were well within the generally acceptedcriteria for analytical methods (≤15%). This method was subsequentlyused to measure plasma concentrations of naloxone and 6α‐naloxol in male AGMs administerednaloxone subcutaneously and intravenously. The developed method demonstratedexcellent recovery, repeatability, accuracy and sensitivity. Support or Funding Information DISCLAIMERS. The views expressed in this abstractare those of the authors (s) and do not reflect the official policy of theDepartment of Army, Department of Defense, or U. S. Government. This researchwas supported by the Defense Threat Reduction Agency – Joint Science andTechnology office, Medical S&T Division. Thisproject was supported in part by an appointment to the Research ParticipationProgram for the U.S. Army Medical Research and Materiel Command administratedby the Oak Ridge Institute for Science and Education through an agreementbetween the U.S. Army Medical Research and Materiel Command. This abstract is from the Experimental Biology 2018 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Bandaru, Veera Venkata Ratnam↗

SCALE 6.2 Continuous-Energy TSUNAMI-3D Capabilities

The TSUNAMI (Tools for Sensitivity and UNcertainty Analysis Methodology Implementation) capabilities within the SCALE code system make use of sensitivity coefficients for an extensive number of criticality safety applications, such as quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different systems, quantifying computational biases, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved ease of use and fidelity and the desire to extend TSUNAMI analysis to advanced applications have motivated the development of a SCALE 6.2 module for calculating sensitivity coefficients using three-dimensional (3D) continuous-energy (CE) Monte Carlo methods: CE TSUNAMI-3D. This paper provides an overview of the theory, implementation, and capabilities of the CE TSUNAMI-3D sensitivity analysis methods. CE TSUNAMI contains two methods for calculating sensitivity coefficients in eigenvalue sensitivity applications: (1) the Iterated Fission Probability (IFP) method and (2) the Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Track length importance CHaracterization (CLUTCH) method. This work also presents the GEneralized Adjoint Response in Monte Carlo method (GEAR-MC), a first-of-its-kind approach for calculating adjoint-weighted, generalized response sensitivity coefficients—such as flux responses or reaction rate ratios—in CE Monte Carlo applications. The accuracy and efficiency of the CE TSUNAMI-3D eigenvalue sensitivity methods are assessed from a user perspective in a companion publication, and the accuracy and features of the CE TSUNAMI-3D GEAR-MC methods are detailed in this paper.

42 ENGINEERING↗

Assessing sensitivities of climate model weighting to multiple methods, variables, and domains in the south-central United States

Given the increasing use of climate projections and multi-model ensemble weighting for a diverse array of applications, this project assesses the sensitivities of climate model weighting strategies and their resulting ensemble means to multiple components, such as the weighting schemes, climate variables, or spatial domains of interest. The purpose of this study is to assess the sensitivities associated with multi-model weighting strategies. The analysis makes use of global climate models from the Coupled Model Intercomparison Project Phase 5 (CMIP5) and their statistically downscaled counterparts created with the localized constructed analogs (LOCA) method. This work focuses on historical and projected future mean precipitation and daily high temperatures of the south-central United States. Results suggest that the model weights and the corresponding weighted model means can be sensitive to the weighting strategy that is applied. For instance, when estimating model weights based on Louisiana precipitation, the weighted projections show a wetter and cooler south-central domain in the future compared to other weighting strategies. Alternatively, for example, when estimating model weights based on New Mexico temperature, the weighted projections show a drier and warmer south-central domain in the future. However, when considering the entire south-central domain in estimating the model weights, the weighted future projections show a compromise in the precipitation and temperature estimates. As for uncertainty, our matrix of results provided a more certain picture of future climate compared to the spread in the original model ensemble. If future impact assessments utilize weighting strategies, then our findings suggest that how the specific weighting strategy is used with climate projections may depend on the needs of an impact assessment or adaptation plan.

54 ENVIRONMENTAL SCIENCES↗

A methodology for airplane parameter estimation and confidence interval determination in nonlinear estimation problems

An algorithm for maximum likelihood (ML) estimation is developed with an efficient method for approximating the sensitivities. The ML algorithm relies on a new optimization method referred to as a modified Newton-Raphson with estimated sensitivities (MNRES). MNRES determines sensitivities by using slope information from local surface approximations of each output variable in parameter space. With the fitted surface, sensitivity information can be updated at each iteration with less computational effort than that required by either a finite-difference method or integration of the analytically determined sensitivity equations. MNRES eliminates the need to derive sensitivity equations for each new model, and thus provides flexibility to use model equations in any convenient format. A random search technique for determining the confidence limits of ML parameter estimates is applied to nonlinear estimation problems for airplanes. The confidence intervals obtained by the search are compared with Cramer-Rao (CR) bounds at the same confidence level. The degree of nonlinearity in the estimation problem is an important factor in the relationship between CR bounds and the error bounds determined by the search technique. Beale's measure of nonlinearity is developed in this study for airplane identification problems; it is used to empirically correct confidence levels and to predict the degree of agreement between CR bounds and search estimates.

Murphy, P. C.↗

Patient-specific quantification of image quality: An automated method for measuring spatial resolution in clinical CT images

Purpose: To develop and validate an automated technique for evaluating the spatial resolution characteristics of clinical computed tomography (CT) images. Methods: Twenty one chest and abdominopelvic clinical CT datasets were examined in this study. An algorithm was developed to extract a CT resolution index (RI) analogous to the modulation transfer function from clinical CT images by measuring the edge-spread function (ESF) across the patient’s skin. A polygon mesh of the air-skin boundary was created. The faces of the mesh were then used to measure the ESF across the air-skin interface. The ESF was differentiated to obtain the line-spread function (LSF), and the LSF was Fourier transformed to obtain the RI. The algorithm’s ability to detect the radial dependence of the RI was investigated. RIs measured with the proposed method were compared with a conventional phantom-based method across two reconstruction algorithms (FBP and iterative) using the spatial frequency at 50% RI, f{sub 50}, as the metric for comparison. Three reconstruction kernels were investigated for each reconstruction algorithm. Finally, an observer study was conducted to determine if observers could visually perceive the differences in the measured blurriness of images reconstructed with a given reconstruction method. Results: RI measurements performed with the proposed technique exhibited the expected dependencies on the image reconstruction. The measured f{sub 50} values increased with harder kernels for both FBP and iterative reconstruction. Furthermore, the proposed algorithm was able to detect the radial dependence of the RI. Patient-specific measurements of the RI were comparable to the phantom-based technique, but the patient data exhibited a large spread in the measured f{sub 50}, indicating that some datasets were blurrier than others even when the projection data were reconstructed with the same reconstruction algorithm and kernel. Results from the observer study substantiated this finding. Conclusions: Clinically informed, patient-specific spatial resolution can be measured from clinical datasets. The method is sufficiently sensitive to reflect changes in spatial resolution due to different reconstruction parameters. The method can be applied to automatically assess the spatial resolution of patient images and quantify dependencies that may not be captured in phantom data.

60 APPLIED LIFE SCIENCES↗

A study of moving base simulation motion cues utilizing washout technique

The present study was conducted to derive data on non-visual motion thresholds utilizing washout technique, and to develop specific threshold values for use as washout parameters. It describes the results of acceleration detection studies carried out using the NASA MSFC General Purpose Simulator which provides six degree-of-freedom cab motion. A series of experiments was performed to test the hypothesis that constant velocity visual cues might suppress non-visual deceleration sensitivity. The psychophysical method employed was the forced-choice procedure which theoretically yields a pure sensitivity measure. The MSFC General Purpose Simulator was programmed to provide velocity ramps in three axes - pitch, fore-aft translation, and vertical translation. Data were collected with and without a constant velocity visual input. Comparison of the current results with classical data suggested significantly greater sensitivity of the human observer to fore-aft accelerations than has generally been reported, sensitivity tending to depend on motion direction and sign of velocity change.

Kirkpatrick, M., III↗

SU-E-J-245: Sensitivity of FDG PET Feature Analysis in Multi-Plane Vs. Single-Plane Extraction

Purpose: Sensitivity of PET-derived texture features to reconstruction methods has been reported for features extracted from axial planes; however, studies often utilize three dimensional techniques. This work aims to quantify the impact of multi-plane (3D) vs. single-plane (2D) feature extraction on radiomics-based analysis, including sensitivity to reconstruction parameters and potential loss of spatial information. Methods: Twenty-three patients with solid tumors underwent [{sup 18}F]FDG PET/CT scans under identical protocols. PET data were reconstructed using five sets of reconstruction parameters. Tumors were segmented using an automatic, in-house algorithm robust to reconstruction variations. 50 texture features were extracted using two Methods: 2D patches along axial planes and 3D patches. For each method, sensitivity of features to reconstruction parameters was calculated as percent difference relative to the average value across reconstructions. Correlations between feature values were compared when using 2D and 3D extraction. Results: 21/50 features showed significantly different sensitivity to reconstruction parameters when extracted in 2D vs 3D (wilcoxon α<0.05), assessed by overall range of variation, Rangevar(%). Eleven showed greater sensitivity to reconstruction in 2D extraction, primarily first-order and co-occurrence features (average Rangevar increase 83%). The remaining ten showed higher variation in 3D extraction (average Range{sub var}increase 27%), mainly co-occurence and greylevel run-length features. Correlation of feature value extracted in 2D and feature value extracted in 3D was poor (R<0.5) in 12/50 features, including eight co-occurrence features. Feature-to-feature correlations in 2D were marginally higher than 3D, ∣R∣>0.8 in 16% and 13% of all feature combinations, respectively. Larger sensitivity to reconstruction parameters were seen for inter-feature correlation in 2D(σ=6%) than 3D (σ<1%) extraction. Conclusion: Sensitivity and correlation of various texture features were shown to significantly differ between 2D and 3D extraction. Additionally, inter-feature correlations were more sensitive to reconstruction variation using single-plane extraction. This work highlights a need for standardized feature extraction/selection techniques in radiomics.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the pseudo-global warming method under flood conditions: a case study from the northeastern US

Abstract. Intensified extreme precipitation and corresponding floods are the most relevant consequences of climate change over the northeastern US (NEUS). To evaluate the impacts of climate change or certain climate perturbations on future extreme weather events which are dynamically similar to historic analogs, the pseudo-global warming (PGW) method has been frequently employed; however, this method lacks precise definition and guidelines, thus limiting its application. More specifically, three key questions related to the application of the PGW method remain unanswered: at what spatial scale should climate perturbations be applied? Among the different meteorological variables available, which ones should be perturbed? And will PGW projections vary significantly when different perturbations are applied? To address these questions, we examine the sensitivity and robustness of conclusions drawn from the PGW method over the NEUS by conducting multiple PGW experiments with varied perturbation spatial scales and choice of perturbed meteorological variables. The results show that the projections of precipitation and other essential variables at the regional mean scale are consistent across the PGW simulations, with a relative difference of much less than 10 %; however, different perturbation modifications can cause significant displacements of the storm events being simulated. Several previously assumed advantages of modifying only the temperature at regional mean scale, such as the preservation of geostrophic balance, do not appear to hold. Also, for these experiments, we find the regional mean perturbation produces a positive precipitation bias because it ignores the land–ocean warming contrast, which is a robust regional response to global warming. Overall, PGW experiments with perturbations from temperature or the combination of temperature and wind at the grid point scale are both recommended, depending on the research questions. The first approach can isolate the spatially dependent thermodynamic impact, and the latter incorporates both the thermodynamic and dynamic impacts.

54 ENVIRONMENTAL SCIENCES↗

Improving the sensitivity of a torsion pendulum by using an optical spring method

We present a scheme aiming at improving the sensitivity of a torsion pendulum by means of radiation-pressure-induced optical spring. Two partial-reflective mirrors are installed on the opposite sides of a torsion pendulum, and one high-reflective mirror is mounted at the end of the torsion beam so that two identical Fabry-Perot cavities can be formed and aligned in series. Due to the antisymmetric radiation pressures acting on the opposite sides of the torsion beam, a negative restoring coefficient can be generated within a certain dynamic range, such that both the resultant torsional rigidity and the resonant frequency of the torsion pendulum are reduced, and the minimum detectable response torque in high-frequency region can be reduced accordingly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental verification of the method for detection of water microleakages in plasma vacuum chambers by using the hydroxyl spectrum

Experimental determination of the sensitivity of the method for detection of water microleakages in the cooling systems of the plasma vacuum chambers of complex electrophysical devices (such as tokamaks, fuel elements of nuclear reactors, and plasmachemical reactors) is considered. It was shown that the spectroscopic method for detection of water microleakages by using the hydroxyl radiation spectrum makes it possible to detect leakages at a level of 10{sup -5} Pa m{sup 3} s{sup -1}. The spatial resolution of the method allows one to localize defects with an accuracy of several centimeters.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computer-aided detection of renal calculi from noncontrast CT images using TV-flow and MSER features

Purpose: Renal calculi are common extracolonic incidental findings on computed tomographic colonography (CTC). This work aims to develop a fully automated computer-aided diagnosis system to accurately detect renal calculi on CTC images. Methods: The authors developed a total variation (TV) flow method to reduce image noise within the kidneys while maintaining the characteristic appearance of renal calculi. Maximally stable extremal region (MSER) features were then calculated to robustly identify calculi candidates. Finally, the authors computed texture and shape features that were imported to support vector machines for calculus classification. The method was validated on a dataset of 192 patients and compared to a baseline approach that detects calculi by thresholding. The authors also compared their method with the detection approaches using anisotropic diffusion and nonsmoothing. Results: At a false positive rate of 8 per patient, the sensitivities of the new method and the baseline thresholding approach were 69% and 35% (p < 1e − 3) on all calculi from 1 to 433 mm{sup 3} in the testing dataset. The sensitivities of the detection methods using anisotropic diffusion and nonsmoothing were 36% and 0%, respectively. The sensitivity of the new method increased to 90% if only larger and more clinically relevant calculi were considered. Conclusions: Experimental results demonstrated that TV-flow and MSER features are efficient means to robustly and accurately detect renal calculi on low-dose, high noise CTC images. Thus, the proposed method can potentially improve diagnosis.

60 APPLIED LIFE SCIENCES↗

Monte Carlo estimates of sensitivities to geometric perturbations for shielding problems using kernel density estimators - 25605

A Monte Carlo method to estimate the sensitivity of reaction rates like dose and flux spectra to geometric perturbations using kernel density estimators is demonstrated for shielding problems. The method is used to estimate the sensitivity of the spectrum emitted from a Cf-252 source at the center of an iron sphere as well as the sensitivity of the dose due to Cf-252 neutrons shielded using various materials. Results are compared against reference solutions obtained using Monte Carlo direct perturbations with central differences, with agreement within 5% and 3σ for the majority of results. The results indicate that a bandwidth that is 10-20% of the shielding thickness produces accurate results with statistically insignificant bias for the chosen test problems. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Sensitivity Analysis for Coupled Aero-structural Systems

A novel method has been developed for calculating gradients of aerodynamic force and moment coefficients for an aeroelastic aircraft model. This method uses the Global Sensitivity Equations (GSE) to account for the aero-structural coupling, and a reduced-order modal analysis approach to condense the coupling bandwidth between the aerodynamic and structural models. Parallel computing is applied to reduce the computational expense of the numerous high fidelity aerodynamic analyses needed for the coupled aero-structural system. Good agreement is obtained between aerodynamic force and moment gradients computed with the GSE/modal analysis approach and the same quantities computed using brute-force, computationally expensive, finite difference approximations. A comparison between the computational expense of the GSE/modal analysis method and a pure finite difference approach is presented. These results show that the GSE/modal analysis approach is the more computationally efficient technique if sensitivity analysis is to be performed for two or more aircraft design parameters.

Giunta, Anthony A.↗

The Half Monte Carlo Method: Combining Total Monte Carlo with Nuclear Data Sensitivity Profiles

Both Total Monte Carlo (TMC) and Generalized Linear Least Squares (GLLS) algorithms have been used extensively to perform nuclear uncertainty propagation. Both methods have strengths and weaknesses, for example, the time required to perform TMC limits its attractiveness, while GLLS cannot generate higher order moments of output distributions and also has trouble dealing with nonlinear distributions. This work uses a new method that overcomes many of the aforementioned limitations of TMC and GLLS, while at the same time reasonably reproduces the TMC result. The concept is a simple combination of the two methods i.e., generate the random nuclear data files using the TMC approach, and then propagate the effect on the integral parameters like k{sub eff} using sensitivity coefficients, as opposed to cumbersome neutron transport calculations. Agreement is demonstrated for the Jezebel sphere ICSBEP benchmark. Since the method is part TMC part GLLS, the term Half Monte Method (HMM) will be used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing the potential of deep learning for protein–ligand docking

The effects of ligand binding on protein structures and their in vivo functions carry numerous implications for modern biomedical research and biotechnology development efforts such as drug discovery. Although several deep learning (DL) methods and benchmarks designed for protein–ligand docking have recently been introduced, so far no previous works have systematically studied the behaviour of the latest docking and structure prediction methods within the broadly applicable context of: (1) using predicted (apo) protein structures for docking (for example, for applicability to new proteins); (2) binding multiple (cofactor) ligands concurrently to a given target protein (for example, for enzyme design); and (3) having no previous knowledge of binding pockets (for example, for generalization to unknown pockets). To enable a deeper understanding of the real-world utility of docking methods, we introduce PoseBench, a comprehensive benchmark for broadly applicable protein–ligand docking. PoseBench enables researchers to rigorously and systematically evaluate DL methods for apo-to-holo protein–ligand docking and protein–ligand structure prediction using both primary ligand and multiligand benchmark datasets, the latter of which we introduce to the DL community. Empirically, using PoseBench, we find that: (1) DL cofolding methods generally outperform comparable conventional and DL docking baseline algorithms, but popular methods such as AlphaFold 3 are still challenged by prediction targets with new protein–ligand binding poses; (2) certain DL cofolding methods are highly sensitive to their input multiple sequence alignments, whereas others are not; and (3) DL methods struggle to strike a balance between structural accuracy and chemical specificity when predicting new or multiligand protein targets.

Morehead, Alex [Lawrence Berkeley National Laborat↗

Total scatter factors of small beams: A multidetector and Monte Carlo study

The scope of this study was to estimate total scatter factors (s{sub c,p}) of the three smallest collimators of the Cyberknife radiosurgery system (5-10 mm in diameter), combining experimental measurements and Monte Carlo simulation. Two microchambers, a diode, and a diamond detector were used to collect experimental data. The treatment head and the detectors were simulated by means of a Monte Carlo code in order to calculate correction factors for the detectors and to estimate total scatter factors by means of a consistency check between measurement and simulation. Results for the three collimators were: s{sub c,p}(5 mm)=0.677{+-}0.004, s{sub c,p}(7.5 mm)=0.820{+-}0.008, s{sub c,p}(10 mm)=0.871{+-}0.008, all relative to the 60 mm collimator at 80 cm source-to-detector distance. The method also allows the full width at half maximum of the electron beam to be estimated; estimations made with different collimators and different detectors were in excellent agreement and gave a value of 2.1 mm. Correction factors to be applied to the detectors for the measurement of s{sub c,p} were consistent with a prevalence of volume effect for the microchambers and the diamond and a prevalence of scattering from high-Z material for the diode detector. The proposed method is more sensitive to small variations of the electron beam diameter with respect to the conventional method used to commission Monte Carlo codes, i.e., by comparison with measured percentage depth doses (PDD) and beam profiles. This is especially important for small fields (less than 10 mm diameter), for which measurements of PDD and profiles are strongly affected by the type of detector used. Moreover, this method should allow s{sub c,p} of Cyberknife systems different from the unit under investigation to be estimated without the need for further Monte Carlo calculation, provided that one of the microchambers or the diode detector of the type used in this study are employed. The results for the diamond are applicable only to the specific detector that was investigated due to excessive variability in manufacturing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗