Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Constraints on rhobar, etabar from B to K*pi

A linear CKM relation, {bar {eta}} = tan {Phi}{sub 3/2}({bar p} - 0.24 {+-} 0.03), involving a 1{sigma} range for {Phi}{sub 3/2}, 20{sup o} < {Phi}{sub 3/2} < 115{sup o}, is obtained from B{sup 0} {yields} K*{pi} amplitudes measured recently in Dalitz plot analyses of B{sup 0} {yields} K{sup +}{pi}{sup -}{pi}{sup 0} and B{sup 0}(t) {yields} K{sub S}{pi}{sup +}{pi}{sup -}. This relation is consistent within the large error on {Phi}{sub 3/2} with other CKM constraints which are unaffected by new b {yields} s{bar q}q operators. Sensitivity of the method to a new physics contribution in the {Delta}S = {Delta}I = 1 amplitude is discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

Set Up and Test Results for a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of a quadrupole. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing it. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). The following break up of error was suggested for the fiducialization steps: 10{micro}m for step 1 (finding the center), 20{micro}m for step 2 (finding the wire), and 10{micro}m for step 3 (tooling ball measurements). The purpose of this study is to investigate whether the vibrating wire system meets the requirements for LCLS. In particular, if it can reliably fiducialize a quadrupole magnetic center to within 25{micro}m in both vertical and horizontal directions. The behavior of individual system components is compared to the expected performance. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note studies the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

The promise of optical NMR spectroscopy for experimental aqueous geochemistry

Here, we discuss new quantum technologies being adapted to detect extraordinarily small magnetic fields. The signals are derived from the stimulated emission of light from single-atom defects in diamonds. The intensity of light reports the spin state of the electrons in the color center. The physics is relevant to geochemists because it points to a means of conducting NMR experiments on solutions in diamond-anvil cells. Because the method is so sensitive, it can detect signals in subnanoliter volumes, making work at elevated temperatures and pressures possible, and also on solutions that are dangerous in larger volumes.

58 GEOSCIENCES↗

Ultrasonic Testing of Mechanical Changes in a Water-Filled Pipe with Multi-Mode and Broadband Signals and Two-Level Compensation

Ultrasonic testing (UT) has been widely used for the Nondestructive Evaluation (NDE) of pipes due to its many favorable characteristics. However, one of the main challenges in the general use of UT for real-world pipelines is the sensitivity of this method to environmental and operational condition changes. This paper proposes a new UT method with enhanced compensation for environmental effects and operational condition changes. In particular, the effectiveness of the new method is tested in the presence of temperature variations, and changes in water flow rate inside a stainless-steel pipe. The proposed UT method uses multi-mode and broadband guided ultrasonic waves in the pipe walls, excited and received by single-element ultrasonic sensors that are spatially separated, forming a measurement zone between any pair of such transmit and receive sensors. Amplitude changes, time shifts, and frequency content variations in the ultrasonic signal due to temperature changes and water flow are evaluated and compensated for reliable UT of mechanical changes in the pipe. It is observed that spurious effects of water flow on ultrasonic response, if not properly compensated, can dominate over effects due to actual mechanical changes, but such liquid-boundary effects can be compensated effectively by the proposed time- and frequency-filtering method.

47 OTHER INSTRUMENTATION↗

Profiling of Amatoxins and Phallotoxins in the Genus Lepiota by Liquid Chromatography Combined with UV Absorbance and Mass Spectrometry

Species in the mushroom genus Lepiota can cause fatal mushroom poisonings due to their content of amatoxins such as α-amanitin. Previous studies of the toxin composition of poisonous Lepiota species relied on analytical methods of low sensitivity or resolution. Using liquid chromatography coupled to UV absorbance and mass spectrometry, we analyzed the spectrum of peptide toxins present in six Italian species of Lepiota, including multiple samples of three of them collected in different locations. Field taxonomic identifications were confirmed by sequencing of the internal transcribed spacer (ITS) regions. For comparison, we also analyzed specimens of Amanita phalloides from Italy and California, a specimen of A. virosa from Italy, and a laboratory-grown sample of Galerina marginata. α-Amanitin, β-amanitin, amanin, and amaninamide were detected in all samples of L. brunneoincarnata, and α-amanitin and γ-amanitin were detected in all samples of L. josserandii. Phallotoxins were not detected in either species. No amatoxins or phallotoxins were detected in L. clypeolaria, L. cristata, L. echinacea, or L. magnispora. The Italian and California isolates of A. phalloides had similar profiles of amatoxins and phallotoxins, although the California isolate contained more β-amanitin relative to α-amanitin. Amaninamide was detected only in A. virosa.

59 BASIC BIOLOGICAL SCIENCES↗

H I and CO velocity dispersions in nearby galaxies

We analyze the velocity dispersions of individual H i and CO profiles in a number of nearby galaxies from the high-resolution HERACLES CO and THINGS H i surveys. Focusing on regions with bright CO emission, we find a CO dispersion value σ{sub CO} = 7.3 ± 1.7 km s{sup −1}. The corresponding H i dispersion σ{sub HI} = 11.7 ± 2.3 km s{sup −1}, yielding a mean dispersion ratio σ{sub HI}/σ{sub CO} = 1.4 ± 0.2, independent of radius. We find that the CO velocity dispersion increases toward lower peak fluxes. This is consistent with previous work where we showed that when using spectra averaged (“stacked”) over large areas, larger values for the CO dispersion are found, and a lower ratio σ{sub HI}/σ{sub CO} = 1.0 ± 0.2. The stacking method is more sensitive to low-level diffuse emission, whereas individual profiles trace narrow-line, GMC-dominated, bright emission. These results provide further evidence that disk galaxies contain not only a thin, low velocity dispersion, high density CO disk that is dominated by GMCs, but also a fainter, higher dispersion, diffuse disk component.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CLOSE COMPANION MASS-RATIO DISTRIBUTION OF INTERMEDIATE-MASS STARS

Binary stars and higher-order multiple systems are a ubiquitous outcome of star formation, especially as the system mass increases. The companion mass-ratio distribution is a unique probe into the conditions of the collapsing cloud core and circumstellar disk(s) of the binary fragments. Inside a∼1000 AU the disks from the two forming stars can interact, and additionally companions can form directly through disk fragmentation. We should, therefore, expect the mass-ratio distribution of close companions (a≲100 AU) to differ from that of wide companions. This prediction is difficult to test using traditional methods, in particular, with intermediate-mass primary stars, for a variety of observational reasons. We present the results of a survey searching for companions to A- and B-type stars using the direct spectral detection method, which is sensitive to late-type companions within ∼1{sup ′′} of the primary and which has no inner working angle. We estimate the temperatures and surface gravity of most of the 341 sample stars and derive their masses and ages. We additionally estimate the temperatures and masses of the 64 companions we find, 23 of which are new detections. We find that the mass-ratio distribution for our sample has a maximum near q∼0.3. Our mass-ratio distribution has a very different form than in previous works, where it is usually well-described by a power law, and indicates that close companions to intermediate-mass stars experience significantly different accretion histories or formation mechanisms than wide companions.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal Matched Filter in the Low-number Count Poisson Noise Regime and Implications for X-Ray Source Detection

Detection of templates (e.g., sources) embedded in low-number count Poisson noise is a common problem in astrophysics. Examples include source detection in X-ray images, γ-rays, UV, neutrinos, and search for clusters of galaxies and stellar streams. However, the solutions in the X-ray-related literature are sub-optimal in some cases by considerable factors. Using the lemma of Neyman–Pearson, we derive the optimal statistics for template detection in the presence of Poisson noise. We demonstrate that, for known template shape (e.g., point sources), this method provides higher completeness, for a fixed false-alarm probability value, compared with filtering the image with the point-spread function (PSF). In turn, we find that filtering by the PSF is better than filtering the image using the Mexican-hat wavelet (used by wavdetect). For some background levels, our method improves the sensitivity of source detection by more than a factor of two over the popular Mexican-hat wavelet filtering. This filtering technique can also be used for fast PSF photometry and flare detection; it is efficient and straightforward to implement. We provide an implementation in MATLAB. The development of a complete code that works on real data, including the complexities of background subtraction and PSF variations, is deferred for future publication.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting Atmospheric Molecules of Nontransiting Temperate Terrestrial Exoplanets Using High-resolution Spectroscopy in the Mid-infrared Domain

Motivated by the development of high-dispersion spectrographs in the mid-infrared (MIR) range, we study their application to the atmospheric characterization of nearby nontransiting temperate terrestrial planets around M-type stars. We examine the detectability of CO{sub 2}, H{sub 2}O, N{sub 2}O, and O{sub 3 }features in high-resolution planetary thermal emission spectra at 12–18 μm assuming an Earth-like profile and a simplified thermal structure. The molecular line width of such planets can be comparable to or broader than the Doppler shift due to the planetary orbital motion. Given the likely difficulty in knowing the high-resolution MIR spectrum of the host star with sufficient accuracy, we propose observing the target system at two quadrature phases and extracting the differential spectra as the planetary signal. In this case, the signals can be substantially suppressed compared with the case where the host star spectrum is perfectly known, as some parts of the spectral features do not remain in the differential spectra. Despite this self-subtraction, the CO{sub 2} and H{sub 2}O features of nearby (≲5 pc) systems with mid-/late-M host stars would be feasible with a 6.5 m class cryogenic space telescope, and orbital inclination could also be constrained for some of them. For CO{sub 2} and N{sub 2}O in a 1 bar Earth-like atmosphere, this method would be sensitive when the mixing ratio is 1–10{sup 3} ppm. The detectability of molecules except O{sub 3} is not significantly improved when the spectral resolution is higher than R≳10,000, although the constraint on the orbital inclination is improved. This study provides some benchmark cases useful for assessing the value of MIR high-resolution spectroscopy in terms of characterization of potentially habitable planets.

47 OTHER INSTRUMENTATION↗

Astromers: Nuclear Isomers in Astrophysics

In this work, we develop a method to compute thermally mediated transition rates between the ground state and long-lived isomers in nuclei. We also establish criteria delimiting a thermalization temperature above which a nucleus may be considered a single species and below which it must be treated as two separate species: a ground-state species and an astrophysical isomer ("astromer") species. Below the thermalization temperature, the destruction rates dominate the internal transition rates between the ground state and the isomer. If the destruction rates also differ greatly from one another, the nuclear levels fall out of or fail to reach thermal equilibrium. Without thermal equilibrium, there may not be a safe assumption about the distribution of occupation probability among the nuclear levels when computing nuclear reaction rates. In these conditions, the isomer has astrophysical consequences and should be treated as a separate astromer species which evolves separately from the ground state in a nucleosynthesis network. We apply our transition-rate methods and perform sensitivity studies on a few well-known astromers. We also study transitions in several other isomers of likely astrophysical interest.

79 ASTRONOMY AND ASTROPHYSICS↗

A new probe of μ Hz gravitational waves with FRB timing

We propose Fast Radio Burst (FRB) timing, which uses the precision measurements of the arrival time differences of repeated FRB signals along multiple sightlines, as a new probe of gravitational waves (GWs) around nHz to μ Hz frequencies, with the highest frequency limited by FRB repeating period. The anticipated experiment requires a sightline separation of tens of AU, achieved by sending radio telescopes to space. We find the signal of arrival time difference induced by GWs depends only on the local GWs in the solar system and we can correlate the measurements from different FRB sources or the same source with different repeaters, which leads to a better sensitivity with a larger number of FRB events detected. The projected sensitivity shows this method is a competitive probe in the nHz to μ Hz frequency range. It can fill the ‘ μ Hz gap’ between pulsar timing arrays and Laser Interferometer Space Antenna (LISA) and is complementary to other proposals of GW detection in this frequency band.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Time-Resolved Aerosol Collector: Proof of Concept

Atmospheric particles can be collected in the field on substrates for subsequent laboratory analysis via chemically sensitive single particle methods such as scanning electron microscopy with energy dispersed x-ray analysis. With moving substrates one can achieve time resolution of seconds to minutes. We demonstrate how to increase the time resolution to a few milliseconds to provide real-time information in this paper. Our fast time-resolved aerosol collector (“Fast-TRAC”) microscopically observes the particle collection on substrate and record an on-line video. Particle arrivals are resolved to within a single frame (17 to 4 ms in this setup), and the spatial locations are matched to the subsequent single particle analysis. This approach provides real-time information on particle size and number concentration. Applications are expected in airborne studies of cloud microstructure, pollution plumes, and long term site monitoring.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of obstacle modelling approaches for resource assessment and small wind turbine siting: case study in the northern Netherlands

Abstract. Growth in adoption of distributed wind turbines for energy generation is significantly impacted by challenges associated with siting and accurate estimation of the wind resource. Small turbines, at hub heights of 40 m or less, are greatly impacted by terrestrial obstacles such as built structures and vegetation that can cause complex wake effects. While some progress in high-fidelity complex fluid dynamics (CFD) models has increased the potential accuracy for modelling the impacts of obstacles on turbulent wind flow, these models are too computationally expensive for practical siting and resource assessment applications. To understand the efficacy of available models in situ, this study evaluates classic and commonly used methods alongside new state-of-the-art lower-order models derived from CFD simulations and machine learning approaches. This evaluation is conducted using a subset of an extensive original dataset of measurements from more than 300 operational wind turbines in the northern Netherlands. The results show that data-driven methods (e.g. machine learning and statistical modelling) are most effective at predicting production at real sites with an average error in annual energy production of 2.5 %. When sufficient data may not be available de novo to support these data-driven approaches, models derived from high-fidelity simulations show promise and reliably outperform classic methods. On average these models have 6.3 %–11.5 % error compared with 26 % for classic methods and 27 % baseline error for reanalysis data without obstacle correction. While more performant on average, these methods are also sensitive to the quality of obstacle descriptions and reanalysis inputs.

17 WIND ENERGY↗

Atomic force microscopy of biological samples

The ability to evaluate structural-functional relationships in real time has allowed scanning probe microscopy (SPM) to assume a prominent role in post genomic biological research. In this mini-review, we highlight the development of imaging and ancillary techniques that have allowed SPM to permeate many key areas of contemporary research. We begin by examining the invention of the scanning tunneling microscope (STM) by Binnig and Rohrer in 1982 and discuss how it served to team biologists with physicists to integrate high-resolution microscopy into biological science. We point to the problems of imaging nonconductive biological samples with the STM and relate how this led to the evolution of the atomic force microscope (AFM) developed by Binnig, Quate, and Gerber, in 1986. Commercialization in the late 1980s established SPM as a powerful research tool in the biological research community. Contact mode AFM imaging was soon complemented by the development of non-contact imaging modes. These non-contact modes eventually became the primary focus for further new applications including the development of fast scanning methods. The extreme sensitivity of the AFM cantilever was recognized and has been developed into applications for measuring forces required for indenting biological surfaces and breaking bonds between biomolecules. Further functional augmentation to the cantilever tip allowed development of new and emerging techniques including scanning ion-conductance microscopy (SICM), scanning electrochemical microscope (SECM), Kelvin force microscopy (KFM) and scanning near field ultrasonic holography (SNFUH).

59 BASIC BIOLOGICAL SCIENCES↗

Single Nanopores in Silicon Nitride Membranes with Applications to Viral Sensing

While current viral sensing methods are extremely sensitive, there is still a need for platforms capable of detecting engineered viruses and being integrated into device architectures for point-of-care assessments. Nanopores could provide a single pathway to achieve these goals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using eigenmodes to perform the inverse problem associated with resonant ultrasound spectroscopy

In principle, resonant ultrasonic spectroscopy (RUS) can be used to characterize any parameter that influences the mechanical resonant response of a sample. Examples include the elastic constants, sample dimensions, and crystal orientation. Extracting the parameter of interest involves performing the inverse problem, which typically entails an iterative routine that compares calculated and measured eigenfrequencies. Here, we propose an alternative method based on laser-based resonant ultrasound spectroscopy (LRUS) that uses the eigenmodes. LRUS uses a pulsed laser to thermoelastically excite ultrasound and an interferometer to detect out-of-plane displacement associated with ultrasonic resonances. By raster scanning the probe along the sample surface, an image of the out-ofplane displacement pattern (i.e., eigenmode) is obtained. As an example of this method, we describe a technique to calculate the crystallographic orientation of a single-crystal high-purity copper sample. The crystallographic orientation is computed by comparing theoretical and experimental eigenmodes. The computed angle is shown to be in very good agreement with the angle obtained using electron backscatter diffraction. In addition, a comparison is made using eigenfrequencies and eigenmodes to calculate the crystallographic orientation. It is found for this particular application, the eigenmode method has superior sensitivity to crystal orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗