Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Investigation of Scale Deposition and Wellbore Corrosion in Carbonated Brine Injection: A Simulation Study

Carbonated brine injection (CBI), which involves dissolving CO2 in produced water to be injected into deep geologic reservoirs, is a method to manage produced brine, carbon dioxide (CO2) sequestration, and reduce anthropogenic greenhouse gas emissions. This low-risk CO2 storage strategy can leverage the existing saltwater disposal infrastructure and well resources. However, the potential for corrosion and scale deposition are a major challenge for carbonated brine which may result in subsidence, wellbore failure, casing failure, and cement failure. The main objective of this research was to evaluate the wellbore materials compatibility with carbonated brine water during the injection process, for repurposing Class II saltwater disposal wells for CBI.

Belarbi, Zineb↗

Define Minimum Safe Operational Volume for Aerial Vehicles in Upper Class E Airspace

This work presents both analytical and simulation studies for defining the minimum safe operational volume needed for aerial vehicles operating in upper Class E airspace. The analytical study is conducted first to investigate factors that affect the minimum safe operational volume, such as position errors, wake/vortex, vehicle maneuverability, communication and surveillance, control/operator response time. A mathematical approach is developed to compute the boundary of the safe operational volume required by the limited aircraft maneuverability and an analytical sensitivity study is then performed with varying parameters. After the analytical study, simulations are then conducted to verify the results from the analytical study. Simulation results will be included in the final paper.

Separation standard, well-clear definition, upper ↗

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulator verification techniques study. Integrated simulator self test system concepts

Software and hardware requirements for implementing hardware self tests are presented in support of the development of training and procedures development simulators for the space shuttle program. Self test techniques for simulation hardware and the validation of simulation performance are stipulated. The requirements of an integrated simulator self system are analyzed. Readiness tests, fault isolation tests, and incipient fault detection tests are covered.

Montoya, G.↗

Simulation verification techniques study. Subsystem simulation validation techniques

Techniques for validation of software modules which simulate spacecraft onboard systems are discussed. An overview of the simulation software hierarchy for a shuttle mission simulator is provided. A set of guidelines for the identification of subsystem/module performance parameters and critical performance parameters are presented. Various sources of reference data to serve as standards of performance for simulation validation are identified. Environment, crew station, vehicle configuration, and vehicle dynamics simulation software are briefly discussed from the point of view of their interfaces with subsystem simulation modules. A detailed presentation of results in the area of vehicle subsystems simulation modules is included. A list of references, conclusions and recommendations are also given.

Duncan, L. M.↗