Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

Dark-field X-ray microscopy with structured illumination for three-dimensional imaging

Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

47 OTHER INSTRUMENTATION↗

High resolution gamma ray tomography scanner for flow measurement and non-destructive testing applications

We report on the development of a high resolution gamma ray tomography scanner that is operated with a Cs-137 isotopic source at 662 keV gamma photon energy and achieves a spatial image resolution of 0.2 line pairs/mm at 10% modulation transfer function for noncollimated detectors. It is primarily intended for the scientific study of flow regimes and phase fraction distributions in fuel element assemblies, chemical reactors, pipelines, and hydrodynamic machines. Furthermore, it is applicable to nondestructive testing of larger radiologically dense objects. The radiation detector is based on advanced avalanche photodiode technology in conjunction with lutetium yttrium orthosilicate scintillation crystals. The detector arc comprises 320 single detector elements which are operated in pulse counting mode. For measurements at fixed vessels or plant components, we built a computed tomography scanner gantry that comprises rotational and translational stages, power supply via slip rings, and data communication to the measurement personal computer via wireless local area network.

36 MATERIALS SCIENCE↗

Progress in the development of an ultrafast pulsed ponderomotive phase plate for cryo-electron tomography

Cryo-electron tomography (cryo-ET) is a powerful modality for resolving cellular structures in their native state. While single-particle cryo-electron microscopy excels in determining protein structures purified from recombinant or endogenous sources due to an abundance of particles, weak contrast issues are accentuated in cryo-ET by low copy numbers in crowded cellular milieux. Continuous laser phase plates offer improved contrast in cryo-ET; however, their implementation demands exceptionally high-peak optical intensities. Instead, a novel experimental approach to enhance contrast in cryo-ET is to manipulate the phase of scattered pulsed electrons using ultrafast pulsed photons. Here, we outline the experimental design of a proof-of-concept electron microscope and demonstrate synchronization between electron packets and laser pulses. Furthermore, we show ultrabright photoemission of electrons from an alloy field emission tip using femtosecond ultraviolet pulses. These experiments pave the way toward exploring the utility of the ponderomotive effect using pulsed radiation to increase phase contrast in cryo-ET of subcellular protein complexes in situ, thus advancing the field of cell biology.

Du, Daniel X. [Columbia Univ., New York, NY (Unite↗

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

Improving Beamline X-ray Optics by Analyzing the Damage to Crystallographic Structure

The mission of the X-ray Characterization Laboratory in the X-ray Science Division (XSD) at the Advanced Photon Source (APS) is to support both the users and the Optics Fabrication Facility that produces high performance optics for synchrotron X-ray beamlines. The Topography Test Unit (TTU) in the X-ray Lab has been successfully used to characterize diffracting crystals and test monochromators by quantifying residual surface stresses. This topographic method has also been adapted for testing standard X-ray mirrors, characterizing concave crystal optics and in principle, can be used to visualize residual stresses on any optic made from single crystalline material. The TTU has been instrumental in quantitatively determining crystal mounting stresses which are mechanically induced by positioning, holding, and cooling fixtures. It is this quantitative aspect that makes topography so useful since the requirements and responses for crystal optics and X-ray mirrors are quite different. In the case of monochromator crystals, even small residual or induced stresses, on the order of tens of kPa, can cause detrimental distortions to the perfect crystal rocking curves. Mirrors, on the other hand, are much less sensitive to induced stresses where stresses that are an order of magnitude greater can be tolerated. This is due to the fact that the surface rather than the lattice-spacing determines a mirror’s performance. For the highly sensitive crystal optics, it is essential to measure the in-situ rocking curves using topographs as mounting fixtures are adjusted. In this way, high heat-load monochromator crystals can be successfully mounted with minimum stress. Topographical analysis has been shown to be a highly effective method to visualize and quantify the distribution of stresses, to help identify methods that mitigate stresses, and most notably to improve diffractive crystal optic rocking curves.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers

Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.

47 OTHER INSTRUMENTATION↗

Semiconductor Nanotechnology: Novel Materials and Devices for Electronics, Photonics, and Renewable Energy Applications

Electronic and photonic information technology and renewable energy alternatives, such as solar energy, fuel cells and batteries, have now reached an advanced stage in their development. Cost-effective improvements to current technological approaches have made great progress, but certain challenges remain. As feature sizes of the latest generations of electronic devices are approaching atomic dimensions, circuit speeds are now being limited by interconnect bottlenecks. This has prompted innovations such as the introduction of new materials into microelectronics manufacturing at an unprecedented rate and alternative technologies to silicon CMOS architectures. Despite the environmental impact of conventional fossil fuel consumption, the low cost of these energy sources has been a long-standing economic barrier to the development of alternative and more efficient renewable energy sources, fuel cells and batteries. In the face of mounting environmental concerns, interest in such alternative energy sources has grown. It is now widely accepted that nanotechnology offers potential solutions for securing future progress in information and energy technologies. The Canadian Semiconductor Technology Conference (CSTC) forum was established 25 years ago in Ottawa as an important symbol of the intrinsic strength of the Canadian semiconductor research and development community, and the Canadian semiconductor industry as a whole. In 2007, the 13th CSTC was held in Montreal, moving for the first time outside the national capital region. The first three meetings in the series of Nano and Giga Challenges in Electronics and Photonics NGCM2002 in Moscow, NGCM2004 in Krakow, and NGC2007 in Phoenix were focused on interdisciplinary research from the fundamentals of materials science to the development of new system architectures. In 2009 NGC2009 and the 14th Canadian Semiconductor Technology Conference (CSTC2009) were held as a joint event, hosted by McMaster University (10 14 August, Hamilton, Ontario, Canada) and the scope was expanded to include renewable energy research and development. This special issue of Nanotechnology is devoted to a better understanding of the function and design of semiconductor devices that are relevant to information technology (both electronics and photonics based) and renewable energy applications. The papers contained in this special issue are selected from the NGC/CSTC2009 symposium. Among them is a report by Ray LaPierre from McMaster University and colleagues at the University of Waterloo in Canada on the ability to manipulate single spins in nanowire quantum bits. The paper also reports the development of a testbed of a few qubits for general quantum information processing tasks [1]. Lower cost and greater energy conversion efficiency compared with thin film devices have led to a high level of activity in nanowire research related to photovoltaic applications. This special issue also contains results from an impedance spectroscopy study of core shell GaAs nanowires to throw light on the transport and recombination mechanisms relevant to solar cell research [2]. Information technology research and renewable energy sources are research areas of enormous public interest. This special issue addresses both theoretical and experimental achievements and provides a stimulating outlook for technological developments in these highly topical fields of research. References [1] Caram J, Sandoval C, Tirado M, Comedi D, Czaban J, Thompson D A and LaPierre R R 2010 Electrical characteristics of core shell p-n GaAs nanowire structures with Te as the n-dopant Nanotechnology 21 134007 [2] Baugh J, Fung J S and LaPierre R R 2010 Building a spin quantum bit register using semiconductor nanowires Nanotechnology 21 134018

14 SOLAR ENERGY↗

Decreasing the emittance using a multi-period Robinson wigglers in TPS

The Taiwan Photon Source (TPS) has been successfully commissioned. However, the minimum emittance in the TPS lattice is 1.6 nm rad. In the existing TPS storage ring lattice, it is imperative to reduce the emittance to below 1 nm rad. Therefore, a feasibility study for reducing the effective emittance of the TPS storage ring by using a Robinson wiggler was launched; the reduction is necessary to enhance the photon brilliance. In this study, a permanent-magnet multiperiod Robinson wiggler (MRW) was developed for use instead of the single-period Robinson wiggler. In general, the quadruple field of a combined function magnet in the storage ring is approximately few tesla per meter. According to beam dynamic analysis, we found that it is necessary to adopt a high gradient (40 T/m) combined-function MRW magnet to reduce the emittance effectively. Therefore, a high gradient field strength is required in the combined function MRW magnet. In this study, the quadrupole field strength of the MRW magnet was allowed to be approximately 40 T/m at a magnet gap of 20 mm. The period length of the MRW magnet was 300 mm and the period number was 16. The of MRWs is discussed in regard to the possibility of increasing the photon brilliance from IU22.

43 PARTICLE ACCELERATORS↗

Structural dynamics of laser-ionized cis-stilbene studied by ultrafast electron diffraction

Stilbene has been a model system for studying photoisomerization upon absorption of a UV photon. Although the dynamics of the first excited state have been investigated in great detail, the structural dynamics of cationic states remains largely experimentally unexplored. In this study, the dynamics following ionization via absorption of two UV photons was captured using ultrafast electron diffraction. cis-stilbene (CS) was optically pumped with 267 nm ultraviolet light with two different pump fluences and probed with 3.7 MeV electrons. We compare our experimental results to ab-initio multiple spawning simulations for single-photon excitation and molecular dynamics simulations for ionization in order to separate the contributions from the two channels. We found that with a fluence of 170 mJ cm −2 both the single and two-photon channels are present, while with higher fluence of 280 mJ cm −2 the two-photon channel dominates. We did not observe isomerization of the CS cation and found the main structural motion a to be a vibration of the phenyl rings about the central C–C bond.

74 ATOMIC AND MOLECULAR PHYSICS↗

Single-photon frequency down-conversion experiment

We report a single-photon frequency down-conversion experiment. Using the difference frequency generation process in a periodically poled lithium niobate waveguide, we successfully observed the phase-preserved frequency down-conversion of a coherent pulse train with an average photon number per pulse of <1, from the 0.7 {mu}m visible wavelength band to the 1.3 {mu}m telecom band. We expect this technology to become an important tool for flexible photonic quantum networking, including the realization of quantum repeater systems over optical fiber using atom-photon entanglement sources for the visible wavelength bands.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NuSTAR Observations of Abell 2163: Constraints on Non-thermal Emission

Since the first non-thermal reports of inverse Compton (IC) emission from the intracluster medium (ICM) of galaxy clusters at hard X-ray energies, we have yet to unambiguously confirm IC emission in observations with newer facilities. RXTE detected IC emission in one of the hottest known clusters, Abell 2163 (A2163), a massive merging cluster with a giant radio halo—the presumed source of relativistic electrons IC scattering CMB photons to X-ray energies. The cluster's redshift (z ~ 0.2) allows its thermal and non-thermal radio emission to fit the field of view of the Nuclear Spectroscopic Telescope Array (NuSTAR), permitting a deep observation capable of confirming or ruling out the RXTE report. The IC flux provides constraints on the average magnetic field strength in a cluster. To determine the global diffuse IC emission in A2163, we fit its global NuSTAR spectrum with four models: single- (1T) and two-temperature (2T), 1T+power-law component (T+IC), and multi-temperature+power law (9T+IC). Each represents different characterizations of the thermal ICM emission, with power-law components added to represent IC emission. We find that the 3–30 keV spectrum can be described by purely thermal emission, with a global average temperature of kT = (11.8 ± 0.2) keV. The IC flux is constrained to <4.0 × 10 –12 erg s –1 cm –2 using the 1T+IC model and <1.6 × 10 –12 erg s –1 cm –2 with the more physical 9T+IC model, both to 90% confidence levels. Here, combining these limits with 1.4 GHz diffuse radio data from the VLA, we find the average magnetic field strength to be >0.22 μG and >0.35 μG, respectively, providing the strongest constraints on these values in A2163 to date.

79 ASTRONOMY AND ASTROPHYSICS↗

Fluorescence from photoexcitation of C2H2 at 50-106 nm

The photoabsorption and fluorescence cross sections of C2H2 were measured in the 50-106 nm region using synchrotron radiation as a light source. Fluorescence observed at several excitation wavelengths was dispersed to identify the fluorescing species that are excited C2H, C2, CH, H, and possibly C2H2. The photodissociation process of C2H2 leading to the formation of fluorescing species is discussed. The C2 (C-A) emission observed at 92.3 and 95.5 nm is produced by the molecular elimination process associated with superexcited state(s). Fluorescence spectra from the two-photon excitation of C2H2 at 157.5 and 193 nm were also observed and compared with those of single-photon excitation at the equivalent excitation energies.

Han, J. C.↗

An XMM-Newton Study of 9SGR and the Lagoon Nebula

We report preliminary results of an XMM-Newton observation of the 04 V star 9 Sgr (= HD 164794). 9 Sgr is one of a few single OB stars that display a non-thermal radio emission attributed to synchrotron emission by relativistic electrons. Inverse Compton scattering of photospheric UV photons by these relativistic electrons is a priori expected to generate a non-thermal power-law tail in the X-ray spectrum. Our EPIC and RGS spectra of 9 Sgr suggest a more complex situation than expected from this 'simple' theoretical picture. Furthermore, soft-band EPIC images of the region around 9 Sgr reveal a number of point sources inside the Lagoon Nebula (M8). Most of these sources have optical counterparts inside the very young open cluster NGC 6530 and several X-ray sources are associated with low and intermediate mass pre-main sequence stars. Finally, we also detect (probably) diffuse X-ray emission from the Hourglass Region that might reveal a hot bubble blown by the stellar wind of Herschel 36, the ionizing star of the HG region.

Rauw, G.↗

Free electron lasers: Present status and future challenges

With the scientific successes of the soft X-ray FLASH facility in Germany and the recent spectacular commissioning of the Linac Coherent Light Source at SLAC, free electron lasers are poised to take center stage as the premier source of tunable, intense, coherent photons of either ultra-short time resolution or ultra-fine spectral resolution, from the far infrared to the hard X-ray regime. This paper examines the state of the art in FEL performance and the underlying enabling technologies. It evaluates the state of readiness of the three basic machine architectures—SASE FELs, seeded FELs, and FEL oscillators—for the major X-ray science user facilities on the 5–10 years time scale and examines the challenges that lie ahead for FELs to achieve their full potential throughout the entire spectral range. In soft and hard X-rays, high longitudinal coherence, in addition to full transverse coherence, will be the key performance upgrade; ideas using laser-based or self-seeding or oscillators can be expected to be qualitatively superior to today&#x27;s SASE sources. Short pulses, from femtoseconds to attoseconds, can be realistically envisioned. With high repetition rate electron sources coupled to superconducting radiofrequency linear accelerators, unprecedented average beam brightness will be possible and many users would be served simultaneously by a single accelerator complex.

43 PARTICLE ACCELERATORS↗

Two photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma

We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm{sup 2}), narrow bandwidth (0.1 cm{sup −1}) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements in a helicon plasma source that demonstrate the TALIF diagnostic is capable of measuring neutral densities spanning four orders of magnitude; comparable to the edge neutral gradients predicted in the DIII-D tokamak pedestal. The measurements are performed in hydrogen and deuterium plasmas and absolute calibration is accomplished through TALIF measurements in neutral krypton. The optical configuration employed is confocal, i.e., both light injection and collection are accomplished with a single lens through a single optical port in the vacuum vessel. The wavelength resolution of the diagnostic is sufficient to separate hydrogen and deuterium spectra and we present measurements from mixed hydrogen and deuterium plasmas that demonstrate isotopic abundance measurements are feasible. Time resolved measurements also allow us to explore the evolution of the neutral hydrogen density and temperature and effects of wall recycling. We find that the atomic neutral density grows rapidly at the initiation of the discharge, reaching the steady-state value within 1 ms. Additionally, we find that neutral hydrogen atoms are born with 0.08 eV temperatures, not 2 eV as is typically assumed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MIXED-MORPHOLOGY SUPERNOVA REMNANTS IN X-RAYS: ISOTHERMAL PLASMA IN HB21 AND PROBABLE OXYGEN-RICH EJECTA IN CTB 1

We present an analysis of X-ray observations of the Galactic supernova remnants (SNRs) HB21 (G89.0+4.7) and CTB 1 (G116.9+0.2), two well-known members of the class of mixed-morphology (MM) SNRs. Our analysis draws upon observations of both SNRs made with the Advanced Satellite for Cosmology and Astrophysics (ASCA): we have also used an archived Chandra observation of CTB 1 as part of this effort. We find a marked contrast between the X-ray properties of HB21 and CTB 1: in the case of HB21, the extracted spectra of the northwest and southeast regions of the X-ray-emitting plasma associated with the SNR can be fit with a single thermal model with marginally enhanced silicon and sulfur abundances. For both of these regions, the derived column density and temperature are N{sub H} {approx} 0.3 x 10{sup 22} cm{sup -2} and kT {approx} 0.7 keV, respectively. No significant spatial differences in temperature or elemental abundances between the two regions are detected and the X-ray-emitting plasma for both regions is close to ionization equilibrium. Our Chandra spectral analysis of CTB 1 reveals that this source is likely an oxygen-rich SNR with enhanced abundances of oxygen and neon: this result is quite surprising for an evolved SNR like CTB 1. The high angular resolution Chandra observation of CTB 1 reveals spectral variations across this SNR: in particular, we have detected localized hard emission with an angular extent of {approx}1'. The extracted ASCA spectra for both the southwest and northeastern regions of CTB 1 cannot be fit with a single thermal component and instead an additional component is required to account for the presence of excess emission seen at higher energies. Based on our fits to the extracted ASCA spectra, we derive a column density N{sub H} {approx} 0.6 x 10{sup 22} cm{sup -2} and a temperature for the soft thermal component of kT{sub soft} {approx} 0.28 keV for both regions. The hard emission from the southwest region may be modeled with either a thermal component with a temperature kT{sub hard} {approx} 3 keV or by a power-law component with a photon index {Gamma} {approx} 2-3; for the northeast region, the hard emission may be modeled with a power-law component with a photon index {Gamma} = 1.4. The detection of center-filled ejecta-dominated X-ray emission from HB21 and CTB 1 as well as other MM SNRs suggests a new scenario for the origin of the contrasting X-ray and radio morphologies of this class of sources. Lastly, we have analyzed the properties of the discrete hard X-ray source 1WGA J0001.4+6229 which is seen in projection just inside the northeastern shell of CTB 1. Our extracted ASCA GIS spectra of this source are best fit using a power-law model with a photon index {Gamma} = 2.2{sup +0.5}{sub -1.2}: this slope is typical for featureless power-law continua produced by rotation-powered pulsars. This source may be a neutron star associated with CTB 1. We find marginal evidence for X-ray pulsations from this source with a period of 47.6154 ms. A deep radio observation of this source failed to reveal any pulsations.

79 ASTRONOMY AND ASTROPHYSICS↗

Curvature of the spectral energy distributions of blazars

In this paper, spectral energy distributions (SED) of both synchrotron and inverse Compton (IC) components of a sample of Fermi bright blazars are fitted by a log-parabolic law. The second-degree term of the log parabola measures the curvature of an SED. We find a statistically significant correlation between the synchrotron peak frequency and its curvature. This result is in agreement with the theoretical prediction and confirms previous studies that dealt with a single source with observations at various epochs or a small sample. If a broken power law is employed to fit the SED, the difference between the two spectral indices (i.e., |α{sub 2} – α{sub 1}|) can be considered a 'surrogate' of the SED curvature. We collect data from the literature and find a correlation between the synchrotron peak frequency and the spectral difference. We do not find a significant correlation between the IC peak frequency and its curvature, which may be caused by a complicated seed photon field. It is also found that the synchrotron curvatures are on average larger than those of IC curvatures, and there is no correlation between these two parameters. As suggested by previous works, both the log-parabolic law of the SED and the above correlation can be explained by statistical and/or stochastic particle accelerations. Based on a comparison of the slops of the correlation, our result seems to favor stochastic acceleration mechanisms and emission processes. Additional evidence, including SED modeling, particle acceleration simulation, and comparisons between some predictions and empirical relations/correlations, also seems to support the idea that the electron energy distribution (and/or synchrotron SED) may be log-parabolic.

79 ASTRONOMY AND ASTROPHYSICS↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗