Search NASA⌕ Search

SEARCH · Search NASA

Results for “slicing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 919 records · Page 51

SU-C-207B-04: Automated Segmentation of Pectoral Muscle in MR Images of Dense Breasts

Purpose: To develop and evaluate a fully automated method for segmentation of the pectoral muscle boundary in Magnetic Resonance Imaging (MRI) of dense breasts. Methods: Segmentation of the pectoral muscle is an important part of automatic breast image analysis methods. Current methods for segmenting the pectoral muscle in breast MRI have difficulties delineating the muscle border correctly in breasts with a large proportion of fibroglandular tissue (i.e., dense breasts). Hence, an automated method based on dynamic programming was developed, incorporating heuristics aimed at shape, location and gradient features.To assess the method, the pectoral muscle was segmented in 91 randomly selected participants (mean age 56.6 years, range 49.5–75.2 years) from a large MRI screening trial in women with dense breasts (ACR BI-RADS category 4). Each MR dataset consisted of 178 or 179 T1-weighted images with voxel size 0.64 × 0.64 × 1.00 mm3. All images (n=16,287) were reviewed and scored by a radiologist. In contrast to volume overlap coefficients, such as DICE, the radiologist detected deviations in the segmented muscle border and determined whether the result would impact the ability to accurately determine the volume of fibroglandular tissue and detection of breast lesions. Results: According to the radiologist’s scores, 95.5% of the slices did not mask breast tissue in such way that it could affect detection of breast lesions or volume measurements. In 13.1% of the slices a deviation in the segmented muscle border was present which would not impact breast lesion detection. In 70 datasets (78%) at least 95% of the slices were segmented in such a way it would not affect detection of breast lesions, and in 60 (66%) datasets this was 100%. Conclusion: Dynamic programming with dedicated heuristics shows promising potential to segment the pectoral muscle in women with dense breasts.

60 APPLIED LIFE SCIENCES↗

Point-spread Function Deconvolution of the IFU Data and Restoration of Galaxy Stellar Kinematics

We present a performance test of the point-spread function (PSF) deconvolution algorithm applied to astronomical integral field unit (IFU) spectroscopy data for restoration of galaxy kinematics. We deconvolve the IFU data by applying the Lucy–Richardson algorithm to the 2D image slice at each wavelength. We demonstrate that the algorithm can effectively recover the true stellar kinematics of the galaxy, by using mock IFU data with a diverse combination of surface brightness profile, signal-to-noise ratio, line-of-sight geometry, and line-of-sight velocity distribution (LOSVD). In addition, we show that the proxy of the spin parameter ${\lambda }_{{R}_{e}}$ can be accurately measured from the deconvolved IFU data. We apply the deconvolution algorithm to the actual SDSS-IV MaNGA IFU survey data. The 2D LOSVD, geometry, and ${\lambda }_{{R}_{e}}$ measured from the deconvolved MaNGA IFU data exhibit noticeable differences compared to the ones measured from the original IFU data. The method can be applied to any other regular-grid IFU data to extract the PSF-deconvolved spatial information.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-18C-05: Characterization of Cross-Vendor, Cross-Field Strength MR Image Intensity Variations

Purpose: Variations in MR image intensity and image intensity nonuniformity (IINU) can challenge the accuracy of intensity-based image segmentation and registration algorithms commonly applied in radiotherapy. The goal of this work was to characterize MR image intensity variations across scanner vendors and field strengths commonly used in radiotherapy. Methods: ACR-MRI phantom images were acquired at 1.5T and 3.0T on GE (450w and 750, 23.1), Siemens (Espree and Verio, VB17B), and Philips (Ingenia, 4.1.3) scanners using commercial spin-echo sequences with matched parameters (TE/TR: 20/500 ms, rBW: 62.5 kHz, TH/skip: 5/5mm). Two radiofrequency (RF) coil combinations were used for each scanner: body coil alone, and combined body and phased-array head coils. Vendorspecific B1- corrections (PURE/Pre-Scan Normalize/CLEAR) were applied in all head coil cases. Images were transferred offline, corrected for IINU using the MNI N3 algorithm, and normalized. Coefficients of variation (CV=σ/μ) and peak image uniformity (PIU = 1−(Smax−Smin)/(Smax+Smin)) estimates were calculated for one homogeneous phantom slice. Kruskal-Wallis and Wilcoxon matched-pairs tests compared mean MR signal intensities and differences between original and N3 image CV and PIU. Results: Wide variations in both MR image intensity and IINU were observed across scanner vendors, field strengths, and RF coil configurations. Applying the MNI N3 correction for IINU resulted in significant improvements in both CV and PIU (p=0.0115, p=0.0235). However, wide variations in overall image intensity persisted, requiring image normalization to improve consistency across vendors, field strengths, and RF coils. These results indicate that B1- correction routines alone may be insufficient in compensating for IINU and image scaling, warranting additional corrections prior to use of MR images in radiotherapy. Conclusions: MR image intensities and IINU vary as a function of scanner vendor, field strength, and RF coil configuration. A two-step strategy consisting of MNI N3 correction followed by normalization was required to improve MR image consistency. Funding provided by Advancing a Healthier Wisconsin.

60 APPLIED LIFE SCIENCES↗

SU-E-T-63: A Preliminary Study of Gold Nanoparticles Enhanced Cone Beam Computed Tomography

Purpose: Gold nanoparticles (GNPs) have potential of being used as a new-generation contrast agent to enhance CT imaging of cancer. This feasibility study is to determine the GNP concentration required to provide sufficient image contrast in small animal cone beam CT (CBCT) imaging. Methods: The GNPs used are nanorods with 10nm diameter and 44nm length. A 50µl GNP colloid with an original GNP concentration of 3.6mg/ml was diluted to five different concentrations at 2.4, 2.1, 2.0, 1.9 and 1.8mg/ml, respectively. The GNP colloid was enclosed in a 150µl vial, and the GNP colloid vial was submerged in a water bottle for CBCT. CBCTs were acquired with x-ray energy of 65kVp and tube current of 1.5mA. In addition, to evaluate the optimal x-ray energy for GNP detection in CBCT, the GNP colloid of 1.8mg/ml was also imaged at x-ray energy of 45kVp and 85kVp. Regions of interest were placed in axial CBCT slices contouring the GNP colloid volume and a same volume in the surrounding water to calculate the signal and contrast. Results: For the GNP colloid at concentrations of 3.6, 2.4, 2.1, 2.0, 1.9 and 1.8mg/ml, the image contrasts between GNP colloid and water were 68±4, 33±4, 23±3, 20±3, 13±4, and 10±3 HU, respectively. At 1.8mg/ml concentration level, the image contrasts were 16±3 and 7±4 HU, respectively, when the x-ray energy was set at 45kVp and 85kVp. Conclusion: The minimal GNP concentration required on our small animal CBCT was estimated to be around 1.8mg/ml due to the fact that the minimum image contrast for adequate differentiation in CT is about 8 HU. CBCT at lower x-ray energy, i.e. 45kVp, can provide better image contrast than at higher energies, i.e., 65kVp and 85kVp. A study of GNP enhanced CBCT for in vivo small animal imaging is ongoing efforts in our group.

60 APPLIED LIFE SCIENCES↗

SU-F-J-153: ACR MRI Phantom Test On a 1.5T MR-Simulator with Flexible Coils Setting and Performance Comparison to Volumetric Head Coil Setting

Purpose: To accommodate head-and-neck (HN) RT simulation scan with immobilization, sub-optimized flexible radiofrequency coils have to be used on an MR-sim rather than a volumetric head coil for diagnostic radiological (DR) applications. In this study, we present and compare ACR MRI phantom test with flexible coils setting (RT-setting) and volumetric head coil setting (DR-setting). Methods: Two 8-channel array coils were wrapped close to an ACR MRI phantom placed on a flat couch-top in RT-setting for acquisition. ACR MRI phantom tests were conducted 10 times for each setting on a 1.5T MR-sim. Sagittal localizer (TE/TR=20/200ms), axial T1 (TE/TR=20/500ms) and T2 scans (2TEs/TR=20,80/2000ms) were acquired (NEX=1). Acqusition and image analysis were conducted following ACR guidelines. Extra 10 RT-setting acquisitions were obtained by enabling prescan normalization. Results: For RT-setting without prescan normalization, all tests passed the ACR recommended criteria but image intensity uniformity. Geometric accuracy was 147.8±0.3mm and 191.0±0.4mm. Spatial resolution was 0.9mm. Slice thickness was 5.2mm±0.1mm (T1) and 5.1±0.1mm (T2). Slice position accuracy was 1.4±0.6mm, −2.2±0.3mm (T1), and 1.5±0.2mm, −2.2±0.2mm (T2). Image uniformity was 80.6%±2.6% (T1) and 80.2%±3.1% (T2) (criteria: ≥87.5% for 1.5T). Ghosting ratio was 0.0006±0.0004. Low contrast detectability was 30.7±1.7 (T1) and 22.6±3.0 (T2). Image uniformity (91.4%±4.2% and 91.8%±4.3%) and low contrast detectability (36.5±1.4 and 31.6±2.2) of DR-setting were better than RT-setting. Prescan normalization substantially improved image uniformity to 93.4%±0.2% and 93.4%±0.3%, but slightly compromised ghosting (0.0033±0.0004) and spatial resolution (0.9mm or 1.0mm) for RT-setting. Conclusion: Flexible coils setting for HN-RT simulation scan could successfully pass ACR criteria (prescan normalization enabled) and generally achieve comparable performance to volumetric coil setting, although compromise on low contrast detectability was observed probably due to the lower signal-to-noise ratio of the flexible coils. Our results could also serve as a reference baseline of high-field MR-sim QA performance under ACR guideline.

60 APPLIED LIFE SCIENCES↗

SU-F-J-159: Influence of the Elevated Posterior Position by Using the Customized Vacuum-Bag On the Abdominal MR Image Quality: A Quantitative Phantom Study

Purpose: Signal-to-noise ratio(SNR) of MR abdominal imaging in diagnostic radiology is maximized by minimizing the coil-to-patient distance. However, for radiotherapy applications, customized vacuum-bag is needed for abdominal immobilization at the cost of the increasing distance to the posterior spine coil. This sub-optimized coil setting for RT applications may compromise image quality, such as SNR and homogeneity, thus potentially affect tissue delineation. In this study, we quantitatively evaluate the effect of the vertical position change on SNR and image quality change using an ACR MR phantom. Methods: An ACR MR phantom was placed on the flat couch top. Images were acquired using an 18-channel body array coil and spine coil on a dedicated 1.5T MR-simulator. The scan was repeated three times with the ACR phantom elevated up to 7.5cm from the couch top, with a step size of 2.5cm. All images were acquired using standard ACR test sequence protocol of 2D spin-echo T1-weighted(TR/TE=500/200ms) and T2-weighted(TR/TE1/TE2=2000/20/80) sequences. For all scans, pre-scan normalization was turned on, and the distance between the phantom and the anterior 18-channel body array coil was kept constant. SNR was calculated using the slice with a large water-only region of the phantom. Percent intensity uniformity(PIU) and low contrast object detectability(LCD) were assessed by following ACR test guidelines. Results: The decrease in image SNR(from 335.8 to 169.3) and LCD(T1: from 31 to 19 spokes, T2: 26 to 16 spokes) were observed with increasing vertical distance. After elevating the phantom by 2.5cm(approximately the thickness of standard vacuum-bag), SNR change(from 335.8 to 275.5) and LCD(T1: 31 to 26 spokes, T2: 26 to 21 spokes) change were noted. However, similar PIU was obtained for all choices of vertical distance (T1: 94.5%–95.0%, T2: 94.4%–96.8%). Conclusion: After elevating the scan object, reduction in SNR level and contrast detectability but no change in image homogeneity was observed.

60 APPLIED LIFE SCIENCES↗

Ultrabright Electron Bunch Injection in a Plasma Wakefield Driven by a Superluminal Flying Focus Electron Beam

Here, we propose a new method for self-injection of high-quality electron bunches in the plasma wakefield structure in the blowout regime utilizing a “flying focus” produced by a drive beam with an energy chirp. In a flying focus the speed of the density centroid of the drive bunch can be superluminal or subluminal by utilizing the chromatic dependence of the focusing optics. We first derive the focal velocity and the characteristic length of the focal spot in terms of the focal length and an energy chirp. We then demonstrate using multidimensional particle-in-cell simulations that a wake driven by a superluminally propagating flying focus of an electron beam can generate GeV-level electron bunches with ultralow normalized slice emittance (~30 nm rad), high current (~17 kA), low slice energy spread (~0.1%), and therefore high normalized brightness (> 10 19 A/ m 2 /rad 2 ) in a plasma of density ~10 19 cm –3 . The injection process is highly controllable and tunable by changing the focal velocity and shaping the drive beam current. Nearterm experiments at FACET II where the capabilities to generate tens of kA, < 10 fs drivers are planned, could potentially produce beams with brightness near 10 20 A / m 2 / rad 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

PRELIMINARY ASSESSMENT OF NDE METHODS ON INSPECTION OF HDPE BUTT FUSION PIPING JOINTS FOR LACK OF FUSION

Studies at the Pacific Northwest National Laboratory in Richland, Washington, are being conducted to evaluate nondestructive examination approaches for inspecting butt fusion joints in high density polyethylene (HDPE) pipe for lack of fusion (LOF). The work provides information to the United States Nuclear Regulatory Commission on the effectiveness and need for volumetric inspection techniques of HDPE butt fusion joints in Section III, Division 1, Class 3, buried piping systems in nuclear power plants. This paper describes results from preliminary assessments using ultrasonic nondestructive techniques and high-speed tensile impact testing for determining joint integrity. A series of butt joints were fabricated in 3408, 12-inch IPS DR-11 material by varying the fusion parameters in attempts to provide good joints and joints containing LOF. These butt joints were visually examined and volumetrically examined with time-of-flight diffraction (TOFD) and phased-array (PA) ultrasound. A limited subset of pipe joint material was destructively analyzed by either slicing through the joint and visually examining the surface or by employing a standard high-speed tensile impact test. Initial correlation of the fusion parameters, nondestructive, and destructive evaluations have shown that areas with gross LOF were detected with both TOFD and PA ultrasound and that the tensile impact test showed a brittle failure at the joint. There is still some ambiguity in results from the less obvious LOF conditions. Current work is targeted on assessing the sensitivity of the ultrasonic volumetric examinations and validating the results with a destructive analysis. It is expected that on-going and future work will lead to quantifying the ultrasonic responses in terms of joint integrity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-269: Tracking of Tumor Regression for Stage III Lung Cancer Using CBCT

Purpose: This study is to evaluate the tumor regression over the course of EBRT treatment and to determine the difference of tumor reduction for stage III lung squamous cell cancer (SCC) and adenocarcinoma using CBCT. Methods: Twenty three stage III lung cancer patients treated in our clinic who had daily cone beam CT (CBCT) were selected for this study (16 adenocarcinoma and 7 SCC cases). Patients received prescription dose in the range of 50Gy–71.4Gy (mean =60.3Gy, median =50Gy) at 1.8Gy or 2Gy per fraction. Treatments spanned over a minimum of five weeks. Initial mean volume of the gross tumor volume (GTV) was 123cc (range = 14.7cc–353.3cc). For this study, we choose six sets of CBCTs at an interval of one week, starting from the first fraction of treatment. Daily CBCTs from treatment linac computer were transferred to MIM Software version 6.0. An experienced physician contoured the primary GTV on each slices of the CBCT for these patients. Results: A consistent regression of the GTVs was observed in all patients, except in one patient (adeno case) where GTV did not change. Weekly volumetric reduction was in the range of 11.2%–16.6%. Maximum reductions were noticed in the first two weeks of the treatment cycle; mean overall (for adeno+SCC) reductions were 16.6%, 14.2% in week-1 and week-2, respectively. Mean reduction over five weeks of treatment was 49.8% (range = 0.1%–75.5%). Higher reduction was observed in SCC patients as compare to adenocarcinoma cases (54.9% vs. 47.6%); however, the difference was not statistically significant (p-value > 0.05). Conclusion: Large regression of tumors over the course of EBRT for stage III lung cancer patients was observed. Both SCC and adenocarcinoma responded well; overall reduction for SCC cases was higher. A future study is warranted for determining the co-relation between tumor volume reduction and treatment outcome.

60 APPLIED LIFE SCIENCES↗

TU-AB-207A-03: Image Quality, Dose, and Clinical Applications

Practicing medical physicists are often time charged with the tasks of evaluating and troubleshooting complex image quality issues related to CT scanners. This course will equip them with a solid and practical understanding of common CT imaging chain and its major components with emphasis on acquisition physics and hardware, reconstruction, artifacts, image quality, dose, and advanced clinical applications. The core objective is to explain the effects of these major system components on the image quality. This course will not focus on the rapid-changing advanced technologies given the two-hour time limit, but the fundamental principles discussed in this course may facilitate better understanding of those more complicated technologies. The course will begin with an overview of CT acquisition physics and geometry. X-ray tube and CT detector are important acquisition hardware critical to the overall image quality. Each of these two subsystems consists of several major components. An in-depth description of the function and failure modes of these components will be provided. Examples of artifacts related to these failure modes will be presented: off-focal radiation, tube arcing, heel effect, oil bubble, offset drift effect, cross-talk effect, and bad pixels. The fundamentals of CT image reconstruction will first be discussed on an intuitive level. Approaches that do not require rigorous derivation of mathematical formulations will be presented. This is followed by a detailed derivation of the Fourier slice theorem: the foundation of the FBP algorithm. FBP for parallel-beam, fan-beam, and cone-beam geometries will be discussed. To address the issue of radiation dose related to x-ray CT, recent advances in iterative reconstruction, their advantages, and clinical applications will also be described. Because of the nature of fundamental physics and mathematics, limitations in data acquisition, and non-ideal conditions of major system components, image artifact often arise in the reconstructed images. Because of the limited scope of this course, only major imaging artifacts, their appearance, and possible mitigation and corrections will be discussed. Assessment of the performance of a CT scanner is a complicated subject. Procedures to measure common image quality metrics such as high contrast spatial resolution, low contrast detectability, and slice profile will be described. The reason why these metrics used for FBP may not be sufficient for statistical iterative reconstruction will be explained. Optimizing radiation dose requires comprehension of CT dose metrics. This course will briefly describe various dose metrics, and interaction with acquisition parameters and patient habitus. CT is among the most frequently used imaging tools due to its superior image quality, easy to operate, and a broad range of applications. This course will present several interesting CT applications such as a mobile CT unit on an ambulance for stroke patients, low dose lung cancer screening, and single heartbeat cardiac CT. Learning Objectives: Understand the function and impact of major components of X-ray tube on the image quality. Understand the function and impact of major components of CT detector on the image quality. Be familiar with the basic procedure of CT image reconstruction. Understand the effect of image reconstruction on CT image quality and artifacts. Understand the root causes of common CT image artifacts. Be familiar with image quality metrics especially high and low contrast resolution, noise power spectrum, slice sensitivity profile, etc. Understand why basic image quality metrics used for FBP may not be sufficient to characterize the performance of advanced iterative reconstruction. Be familiar with various CT dose metrics and their interaction with acquisition parameters. New development in advanced CT clinical applications. JH: Employee of GE Healthcare. FD: No disclosure.; J. Hsieh, Jiang Hsieh is an employee of GE Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-C-17A-02: Sirius MRI Markers for Prostate Post-Implant Assessment: MR Protocol Development

Purpose: Currently, CT is used to visualize prostate brachytherapy sources, at the expense of accurate structure contouring. MRI is superior to CT for anatomical delineation, but the sources appear as voids on MRI images. Previously we have developed Sirius MRI markers (C4 Imaging) to replace spacers to assist source localization on MRI images. Here we develop an MRI pulse sequence protocol that enhances the signal of these markers to enable MRI-only post-implant prostate dosimetric analysis. Methods: To simulate a clinical scenario, a CIRS multi-modality prostate phantom was implanted with 66 markers and 86 sources. The implanted phantom was imaged on both 1.5T and 3.0T GE scanners under various conditions, different pulse sequences (2D fast spin echo [FSE], 3D balanced steadystate free precession [bSSFP] and 3D fast spoiled gradient echo [FSPGR]), as well as varying amount of padding to simulate various patient sizes and associated signal fall-off from the surface coil elements. Standard FSE sequences from the current clinical protocols were also evaluated. Marker visibility, marker size, intra-marker distance, total scan time and artifacts were evaluated for various combinations of echo time, repetition time, flip angle, number of excitations, bandwidth, slice thickness and spacing, fieldof- view, frequency/phase encoding steps and frequency direction. Results: We have developed a 3D FSPGR pulse sequence that enhances marker signal and ensures the integrity of the marker shape while maintaining reasonable scan time. For patients contraindicated for 3.0T, we have also developed a similar sequence for 1.5T scanners. Signal fall-off with distance from prostate to coil can be compensated mainly by decreasing bandwidth. The markers are not visible using standard FSE sequences. FSPGR sequences are more robust for consistent marker visualization as compared to bSSFP sequences. Conclusion: The developed MRI pulse sequence protocol for Sirius MRI markers assists source localization to enable MRIonly post-implant prostate dosimetric analysis. S.J. Frank is a co-founder of C4 Imaging (manufactures the MRI markers)

60 APPLIED LIFE SCIENCES↗

Algorithms for thermal and mechanical contact in nuclear fuel performance analysis

The transfer of heat and force from UO{sub 2} pellets to the cladding is an essential element in typical nuclear fuel performance modeling. Traditionally, this has been accomplished in a one-dimensional fashion, with a slice of fuel interacting with a slice of cladding. In this manner, the location at which the transfer occurs is set a priori. While straightforward, this limits the applicability and accuracy of the model. We propose finite element algorithms for the transfer of heat and force where the location for the transfer is not predetermined. This enables analysis of individual fuel pellets with large sliding between the fuel and the cladding. The simplest of these approaches is a node on face constraint. Heat and force are transferred from a node on the fuel to the cladding face opposite. Another option is a transfer based on quadrature point locations, which is applied here to the transfer of heat. The final algorithm outlined here is the so-called mortar method, with applicability to heat and force transfer. The mortar method promises to be a highly accurate approach which may be used for a transfer of other quantities and in other contexts, such as heat from cladding to a CFD mesh of the coolant. This paper reviews these approaches, discusses their strengths and weaknesses, and presents results from each on simplified nuclear fuel performance models. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-G-JeP3-05: Geometry Based Transperineal Ultrasound Probe Positioning for Image Guided Radiotherapy

Purpose: The use of ultrasound (US) imaging in radiotherapy is not widespread, primarily due to the need for skilled operators performing the scans. Automation of probe positioning has the potential to remove this need and minimize operator dependence. We introduce an algorithm for obtaining a US probe position that allows good anatomical structure visualization based on clinical requirements. The first application is on 4D transperineal US images of prostate cancer patients. Methods: The algorithm calculates the probe position and orientation using anatomical information provided by a reference CT scan, always available in radiotherapy workflows. As initial test, we apply the algorithm on a CIRS pelvic US phantom to obtain a set of possible probe positions. Subsequently, five of these positions are randomly chosen and used to acquire actual US volumes of the phantom. Visual inspection of these volumes reveal if the whole prostate, and adjacent edges of bladder and rectum are fully visualized, as clinically required. In addition, structure positions on the acquired US volumes are compared to predictions of the algorithm. Results: All acquired volumes fulfill the clinical requirements as specified in the previous section. Preliminary quantitative evaluation was performed on thirty consecutive slices of two volumes, on which the structures are easily recognizable. The mean absolute distances (MAD) between actual anatomical structure positions and positions predicted by the algorithm were calculated. This resulted in MAD of 2.4±0.4 mm for prostate, 3.2±0.9 mm for bladder and 3.3±1.3 mm for rectum. Conclusion: Visual inspection and quantitative evaluation show that the algorithm is able to propose probe positions that fulfill all clinical requirements. The obtained MAD is on average 2.9 mm. However, during evaluation we assumed no errors in structure segmentation and probe positioning. In future steps, accurate estimation of these errors will allow for better evaluation of the achieved accuracy.

60 APPLIED LIFE SCIENCES↗

Visualization of Flowfield Modification by RCS Jets on a Capsule Entry Vehicle

Nitric oxide planar laser-induced fluorescence (NO PLIF) has been used to visualize the flow on the aft-body of an entry capsule having an activated RCS jet in NASA Langley Research Center's 31-Inch Mach 10 wind tunnel facility. A capsule shape representative of the Apollo command module was tested. These tests were performed to demonstrate the ability of the PLIF method to visualize RCS jet flow while providing some preliminary input to NASA's Orion Vehicle design team. Two different RCS nozzle designs - conical and contoured - were tested. The conical and contoured nozzles had area ratios of 13.4 and 22.5 respectively. The conical nozzle had a half-angle of 10 . Low- and high-Reynolds number cases were investigated by changing the tunnel stagnation pressure from 350 psi to 1300 psi, resulting in freestream Reynolds numbers of 0.56 and 1.8 million per foot respectively. For both of these cases, three different jet plenum pressures were tested (nominally 56, 250 and 500 psi). A single angle-of-attack was investigated (24 degrees). NO PLIF uses an ultraviolet laser sheet to interrogate a slice in the flow containing seeded NO; this UV light excites fluorescence from the NO molecules which is detected by a high-speed digital camera. The system has spatial resolution of about 200 microns (2 pixel blurring) and has flow-stopping time resolution (approximately 1 microsecond). NO was seeded into the flow two different ways. First, the RCS jet fluid was seeded with approximately 1-5% NO, with the balance N2. This allowed observation of the shape, structure and trajectory of the RCS jets. Visualizations of both laminar and turbulent flow jet features were obtained. Visualizations were obtained with the tunnel operating at Mach 10 and also with the test section held at a constant pressure similar to the aftbody static pressure (0.04 psi) obtained during tunnel runs. These two conditions are called "tunnel on" and "tunnel off" respectively. Second, the forebody flow was seeded with a very low flowrate (<100 standard cubic centimeters per minute) of pure NO. This trace gas was entrained into and allowed visualization of the shear layer forming between the expansion fan on the shoulder of the model and the recirculating separated flow in the wake of the model. This shear layer was observed to be laminar in the absence of the RCS jet operation and turbulent above a certain RCS jet flowrate. Furthermore, the operation of the RCS jet is seen to push the shear layer out away from the model, with a higher jet pressures resulting in larger deflections. Figures show some data from this test, partially processed. In the final paper, these images will be processed and rendered on a three dimensional visualization of the test hardware for clearer visualization and interpretation of the flowfields.

Danehy, P. M.↗

Radiochemical Method for Characterization of the Filter Cartridges from the IEA-R1 Reactor - 16324

The filter cartridges used in water purification system of the IEA-R1 research reactor become radioactive waste after the end of their useful life. The characterization of this waste is one step in their management, which aims at identifying and quantifying the radionuclides present, including those known as 'difficult to measure' (DTM) radionuclides. Wastes from nuclear reactors contain fission and activation products and transuranic elements, only few of them emitting gamma radiation measurable by simple gamma spectrometry methods. In routine waste management activities, the concentrations of the DTM can only be estimated by indirect methods such as scaling factors. The method of the scaling factors uses empirically determined proportions between the concentrations of DTM radionuclides and that of easily measurable gamma emitters called key nuclides (KN), to calculate DTM concentrations. Determining the scaling factors for the filter cartridges is a hard task when the number of samples is large, not only because the preparation of samples is difficult but also because the number of radionuclides to analyze is large. If it can be demonstrated that DTM and KN are both distributed evenly in the filters, less samples from each filter are necessary, reducing lab work. The aim of this paper is to present the results of the assessment of homogeneity along the filter cartridges by gamma spectrometry of chemically reduced samples. Five thin slices of five filters were burnt and the ashes quantitatively dissolved and the activity concentration of the solutions determined by gamma spectrometry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Contrast-to-noise ratio optimization for a prototype phase-contrast computed tomography scanner

In the field of biomedical X-ray imaging, novel techniques, such as phase-contrast and dark-field imaging, have the potential to enhance the contrast and provide complementary structural information about a specimen. In this paper, a first prototype of a preclinical X-ray phase-contrast CT scanner based on a Talbot-Lau interferometer is characterized. We present a study of the contrast-to-noise ratios for attenuation and phase-contrast images acquired with the prototype scanner. The shown results are based on a series of projection images and tomographic data sets of a plastic phantom in phase and attenuation-contrast recorded with varying acquisition settings. Subsequently, the signal and noise distribution of different regions in the phantom were determined. We present a novel method for estimation of contrast-to-noise ratios for projection images based on the cylindrical geometry of the phantom. Analytical functions, representing the expected signal in phase and attenuation-contrast for a circular object, are fitted to individual line profiles of the projection data. The free parameter of the fit function is used to estimate the contrast and the goodness of the fit is determined to assess the noise in the respective signal. The results depict the dependence of the contrast-to-noise ratios on the applied source voltages, the number of steps of the phase stepping routine, and the exposure times for an individual step. Moreover, the influence of the number of projection angles on the image quality of CT slices is investigated. Finally, the implications for future imaging purposes with the scanner are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fully plasma-based electron injector for a linear collider or XFEL

We demonstrate through high-fidelity particle-in-cell (PIC) simulations a simple approach for efficiently generating 20 + GeV electron beams with the necessary charge, energy spread, and emittance for use as an injector in a future linear collider or a next generation XFEL. A high quality injected bunch is generated by self-focusing an unmatched electron driver in a nonlinear plasma wakefield. Over pump depletion distances, the drive beam dynamics and self-loading effects lead to high energy, low-energy spread output beams. For plasma densities of 10 18 c⁢m −3 , PIC simulation results indicate that self-injected beams with 0.52 n⁢C charge can be accelerated to 20 GeV with projected core energy spreads of ≲ 1%, normalized slice emittances of 110n⁢m, peak normalized brightness of ≳ 10 19 A/m 2 /rad 2 , and transfer efficiencies of ≳ 44%.

Particle acceleration in plasmas↗